ALTA LABS S8-POE User manual

QUICK START GUIDE
MODEL: S8-POE
1
2
3
4
5678
RESET
PoE+, 54VDC, 0.6A Max

1
Before You Begin
Download the Alta app on your mobile device,
and create your free Alta account.
You may also visit manage.alta.inc to manage
your Alta devices.
manage.alta.inc

2
Package Contents
12 3 4 5 6 7 8
RESET
PoE+, 54VDC, 0.6A Max
S8-POE
Mounting Bracket Mounting Screws
(M3x20mm, Qty. 2)
Anchors
(Qty. 2)
Power Supply
Note: We recommend using the
included mounting hardware for
product installation.
Installation Requirements
•Ethernet cabling (CAT 5 or above)
•Phillips screwdriver (for mounting)
•Pencil (for marking mounting template)
•Drill and drill bit (for mounting)

3
Hardware Overview
Top
The Alta Labs LED on top of the switch flashes
as the unit is powered up. Once fully booted,
the LED will remain lit unless turned off in the
UI. The LED color can also be changed in the
management interface.
Bottom
SN: S8POEAXXWWXXXXXXXXXXXX
Alta Labs - www.alta.inc
192 N Old Highway 91
Hurricane, UT 84737 USA
Model: S8-POE
AC Input: X~XV, X-X Hz, XXA
NCA APPROVED XXXXXXXX
CAN ICES-3(A)/NMB-3(A)
TAXXXX-YYYY
APPROVED
FCC ID: XXXXX-XXXXXX
IC: XXXXX-XXXXXX
Wim Duisenbergplantsoen 31
6221 SE Maastricht, Netherlands
Made in China
SoundVision Technologies, dba Alta Labs
IFETEL: XXXXXXXX
The bottom of the switch has padding for
desktop placement and notches for mounting.

4
Back
Input :
54V 1.3A
Input :
54V 1.3A
Be sure to use the included power cord to
connect power.
Front
12 3 4 5 6 7 8
RESET
PoE+, 54VDC, 0.6A Max
12 3 4 5 6 7 8
RESET
PoE+, 54VDC, 0.6A Max
Reset Button Press down for 10 seconds until
the LED begins flashing to reset the switch to
factory defaults.

5
Ports and LEDs
12 3 4 5 6 7 8
RESET
PoE+, 54VDC, 0.6A Max
12 3 4 5 6 7 8
RESET
PoE+, 54VDC, 0.6A Max
Ports 1-4 support 802.3at PoE+
with up to 30W per port and a
PoE budget of 60 Watts. These
ports are standard Gigabit
Ethernet ports that support
10/100/1000 Mbps connections.
The Link LED on the left indicates
a 10/100 Mbps connection when
amber, blue indicates a 1 Gbps
connection, and if not illuminated,
the connection is down.
The PoE LED on the right will
illuminate amber when a device
connected to the port is being
powered via Ethernet.
Ports 5-8 are standard Gigabit
Ethernet ports that support
10/100/1000 Mbps connections.
The Link LED indicates a
10/100 Mbps connection when
amber, blue indicates a 1 Gbps
connection, and if not illuminated,
the connection is down.

6
Hardware Installation
Mounting On A Wall
1. Locate the template included with the Quick
Start Guide and Safety document.
60 mm
S8-PoE Wall-MountTemplate
Community Forum
forum.
alta.inc
Technical Support
Template

7
2. Position the template in the desired location
and use a pencil to mark the holes.
60 mm
S8-PoEWall-Mount Template
60 mm
S8-PoEWall-Mount Template
Vertical Mount or Horizontal Mount
3. Secure the Mounting Bracket to the wall
using the Mounting Screws and a Phillips
screwdriver. Be sure to use the screws
included with the product.
If mounting on drywall, use the anchors to
ensure secure mounting. Use a 6 mm drill
bit to drill the holes for the anchors and
insert them in the wall.

8
4.Align the switch with the Mounting Bracket.
Note: the Alta Labs A logo should be facing
the same position on the mount and the
switch. Slide the notches over the tabs to
lock the switch into place.
Input :
54V 1.3A
5. Connect the Power Supply to the switch and
the other end to a power outlet.
Input:
54V 1.3A

9
Connecting Devices
Connect devices that need Power over
Ethernet to any of the first four ports. The
ports are autosensing. Devices that do not
require power can be connected to any port.
1
2
3
4
5678
RESET
PoE+, 54VDC, 0.6A Max
Set Up Your Device
Follow the instructions in the Alta app or
management interface to set up your switch.
1.0
bcb923123426
New Switch
Home Base
Set Up

10
S8-POE Specifications
Mechanical
Dimensions 25.7 x 91 x 180 mm (1 x 3.6 x 7.1")
Weight .38 kg (.83 lbs)
Material Type Injection Molded Plastic
Material Finish Matte
Color White
Ports
Interface ports (8) 10/100/1000 Mbps
SFP/SFP+ None
Switching Capacity 16 Gbps
Non-blocking Throughput 8 Gbps
Forwarding Rate 11.9 Gbps
PoE Budget/Max 60 Watts
PoE Supply 30 Watts per port
Per Port PoE (4) 802.3at PoE+
Non-PoE Ports (4)
LEDs
PoE Orange
Network Orange: 10/100 Mbps,
Blue: 1000Mbps
SFP/SFP+ None
Hardware
Packet Buffer 4.1 Mbit
Mac Table Size 8 K

11
Hardware
Energy Efficient Ethernet Yes
Management Factory reset button
Bluetooth Yes, Setup
Power
Max Power Consumption
w/o PoE 8 Watts
Max Power Consumption
Full PoE 68 Watts
Power Supply Universal AC, 100 - 240VAC
50/60Hz External
RJ45 Port Surge
Protection
12kV for ESD - contact, 25kV
for ESD - Air
Environmental
Mounting Locking Wallmount
Operating Temperature -5 to 50° C (23 to 122° F)
Operating Humidity 10 to 90% Noncondensing
IP Rating None
EMI Rating EMI Class-B with 3dB margin
Cooling Fan No (Fanless cooling)
Certifications CE, FCC, IC

12
Compliance
Federal Communication Commission
Interference Statement
This product has been tested and found to comply with the
limits for a Class B digital device pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the
equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference
to radio communications. Operations of this equipment
in a residential area is likely to cause harmful interference
in which case the user will be required to correct the
interference at his own expense.
However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference
by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and
receiver.
• Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician
for help.
FCC Caution
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received,
including interference that may cause undesired
operation.
This device is restricted to indoor use.
Non-Modification Statement
Changes or modifications not expressly approved by the
party responsible for compliance could void the user’s
authority to operate the equipment.

13
FCC Radiation Statement
This equipment complies with FCC radiation exposure limits
set forth for an uncontrolled environment. This equipment
should be installed and operated with minimum distance
20cm between the radiator and your body.
CAN ICES-003(B) / NMB-003(B)
This device contains licence-exempt transmitter(s)/
receiver(s) that comply with Innovation, Science and
Economic Development Canada’s licence-exempt RSS(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including
interference that may cause undesired operation of the
device.
L’émetteur/récepteur exempt de licence contenu dans
le présent appareil est conforme aux CNR d’Innovation,
Sciences et Développement économique Canada
applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes :
(1) L’appareil ne doit pas produire de brouillage;
(2) L’appareil doit accepter tout brouillage radioélectrique
subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
ISED Radiation Exposure Statement:
This equipment complies with IC RSS-102 radiation
exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body.
Cet équipement est conforme aux limites d’exposition
aux rayonnements IC établies pour un environnement
non contrôlé. Cet équipement doit être installé et utilisé
avec un minimum de 20cm de distance entre la source de
rayonnement et votre corps.
The transmitter module may not be co-located with any
other transmitter or antenna.
Le module émetteur peut ne pas être coïmplanté avec un
autre émetteur ou antenne.
Table of contents
Other ALTA LABS Switch manuals