Altec Lansing T5100 TRANSFORMER User manual

70.7 / 100V
Transformers
Power Rating:
60 Watts (T560-71);
100 Watts (T5100-71)
Frequency Response:
35 Hz to 15 kHz, ±0.5 dB
Total Harmonic Distortion:
< 0.5% at Rated Power, from
35 Hz to 15 kHz
Phase Response:
-15º to +35º
Insertion loss:
< 1 dB from 35 Hz to 15 kHz
(typically < 0.5 dB from 35 Hz
to 10 kHz)
Primary Taps:
4 Ωand 8 Ω
Secondary Taps:
70.7V and 100V
Hi-Pot: 500 VAC
T560-71/T5100-71
GENERAL PRODUCT DESCRIPTION
Altec Lansing is renowned for its high quality transformers.
The new Altec Lansing Professional transformers, T560-71
and T5100-71, are perfect complements to our premium
Duplex® Speakers when the prerequisite is high fidelity.
These transformers are designed for 70.7V or 100V distribution
of amplifier power, with minimal loss, to multiple loudspeakers.
True electrical isolation is provided to the source and the load
by the primary and secondary windings respectively. Installation
is simple with 0.25-inch blade type wire terminals, allowing
either solder connections or crimp type quick-connect wire
terminals.
FEATURES – THE ALTEC LANSING DIFFERENCE
• High Fidelity Transmission
• True Electrical Isolation
• Superior Efficiency
• Easily Installed
• Adaptable for use as either step-up
or step down line transformers
• Excellent choice for distributed systems featuring
Altec Lansing’s Premium Duplex® Speakers
PROFESSIONAl
1000 W. Wilshire Blvd., Suite 362 • Oklahoma City, Oklahoma 73116 • Phone: 1-405-848-3108 • Fax: 1-405-848-3217 • www.altecpro.com
T560-71
T5100-71
Length Width
3.75”
Height
3.50”
Hole
Center on
Length
3.39”
Hole
Center on
Width
3.00”
Hole
Dimension
0.25” x 0.35”
Winding
Thickness
4.06”
Core
Thickness
2.00”
Bracket
Thickness
0.063”
Weight
8 lbs.
Weights & measures
specifications
ARCHITECTS & ENGINEERS SPECIFICATION
The transformers shall be Altec Lansing Professional model numbers T560-71 and T5100-71, rated at 60 Watts and 100 Watts, respectively.
Their frequency response shall be 35 Hz to 15,000 Hz, ±0.5 dB. Throughout their 35 Hz to 15,000 Hz bandwidth, at rated power, they shall
produce no more than 0.5% T.H.D., and their insertion loss shall not exceed 1 dB. These transformers shall require no more than 10%
above their rated input power to deliver rated power to the load at 35 Hz. The T560-71 and T5100-71 shall provide true electrical
isolation to the source and to the load. Connection to these transformers shall be through 0.25-inch blade type wire terminals. The
nominal primary taps shall be 4 ohm and 8 ohm, and the nominal secondary taps shall be 70.7V and 100V.round white metal grille.E
E5475 REV01
© 2002 Altec Lansing Professional
1000 W. Wilshire Blvd., Suite 362
Oklahoma City, Oklahoma 73116
Phone: 1-405-848-3108 • Fax: 1-405-848-3217
Web: www.altecpro.com • Email: [email protected]
PROFESSIONAl
T560-71
T5100-71
4 Ohm
to 70 V
1:4.5
1:3.5
4 Ohm
to 100 V
1:6.4
1:5.0
8 Ohm
to 70 V
1:3.2
1:2.5
8 Ohm
to 100 V
1:4.6
1:3.5
4/8 term
to 70 V
1:10.9
1:8.5
4/8 term
to 100 V
1:15.4
1:12.0
voltage ratio
T560-71
T5100-71
4 Ohm
to 70 V
1:20.8
1:12.5
4 Ohm
to 100 V
1:41.7
1:25.0
8 Ohm
to 70 V
1:10.4
1:6.3
8 Ohm
to 100 V
1:20.8
1:12.5
4/8 term
to 70 V
1:21.9
1:13.1
4/8 term
to 100 V
1:44.0
1:27.0
impedance ratio
wiring diagram
COMMONCOMMON
4 Ω
70.7 V
100 V 8 Ω

This manual suits for next models

3

Other Altec Lansing Transformer manuals

Altec Lansing 15567A TRANSFORMER User manual

Altec Lansing

Altec Lansing 15567A TRANSFORMER User manual

Altec Lansing 15515A TRANSFOMER User manual

Altec Lansing

Altec Lansing 15515A TRANSFOMER User manual

Altec Lansing 15095A TRANSFORMER User manual

Altec Lansing

Altec Lansing 15095A TRANSFORMER User manual

Altec Lansing 15000 TRANSFORMERS User manual

Altec Lansing

Altec Lansing 15000 TRANSFORMERS User manual

Altec Lansing 15550A TRANSFORMERS User manual

Altec Lansing

Altec Lansing 15550A TRANSFORMERS User manual

Altec Lansing 15335A User manual

Altec Lansing

Altec Lansing 15335A User manual

Popular Transformer manuals by other brands

Tektronix CT-4 instruction manual

Tektronix

Tektronix CT-4 instruction manual

American Rotary AMP 208-240V user manual

American Rotary

American Rotary AMP 208-240V user manual

Justin MTP Series Installation and operator's guide

Justin

Justin MTP Series Installation and operator's guide

Paradise Datacom GL33050 manual

Paradise Datacom

Paradise Datacom GL33050 manual

DiodeDrive LVT-W-12VAC Series user manual

DiodeDrive

DiodeDrive LVT-W-12VAC Series user manual

ELEQ GSKF 1 Series Assembling Instruction

ELEQ

ELEQ GSKF 1 Series Assembling Instruction

QSC IT-8400 installation guide

QSC

QSC IT-8400 installation guide

Monacor TR-510 manual

Monacor

Monacor TR-510 manual

AB Quality Allen-Bradley 1609-5000CCT user manual

AB Quality

AB Quality Allen-Bradley 1609-5000CCT user manual

Amada ITB-780C6 Operation manual

Amada

Amada ITB-780C6 Operation manual

Tube Works 4001 owner's manual

Tube Works

Tube Works 4001 owner's manual

Heitronic 20155 Installation and operating instructions

Heitronic

Heitronic 20155 Installation and operating instructions

Titanium TT-DR-CVR-040 manual

Titanium

Titanium TT-DR-CVR-040 manual

Roland VT-1 owner's manual

Roland

Roland VT-1 owner's manual

Jobsite BT-SVSA Installation and user guide

Jobsite

Jobsite BT-SVSA Installation and user guide

EINHELL BT-VT 600 Original operating instructions

EINHELL

EINHELL BT-VT 600 Original operating instructions

Devine DI-P user manual

Devine

Devine DI-P user manual

Mi-Heat Heizsysteme EP-1000-36-2.FC manual

Mi-Heat Heizsysteme

Mi-Heat Heizsysteme EP-1000-36-2.FC manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.