manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Altec Lansing
  6. •
  7. Transformer
  8. •
  9. Altec Lansing T5100 TRANSFORMER User manual

Altec Lansing T5100 TRANSFORMER User manual

This manual suits for next models

3

Other Altec Lansing Transformer manuals

Altec Lansing 15000 TRANSFORMERS User manual

Altec Lansing

Altec Lansing 15000 TRANSFORMERS User manual

Altec Lansing 15550A TRANSFORMERS User manual

Altec Lansing

Altec Lansing 15550A TRANSFORMERS User manual

Altec Lansing 15515A TRANSFOMER User manual

Altec Lansing

Altec Lansing 15515A TRANSFOMER User manual

Altec Lansing 15335A User manual

Altec Lansing

Altec Lansing 15335A User manual

Altec Lansing 15567A TRANSFORMER User manual

Altec Lansing

Altec Lansing 15567A TRANSFORMER User manual

Altec Lansing 15095A TRANSFORMER User manual

Altec Lansing

Altec Lansing 15095A TRANSFORMER User manual

Popular Transformer manuals by other brands

AL’S GARDEN ART AG-83 quick start guide

AL’S GARDEN ART

AL’S GARDEN ART AG-83 quick start guide

janitza KUW 1/30 installation guide

janitza

janitza KUW 1/30 installation guide

Delta Electronics Planar DC/DC Transformer RM8 specification

Delta Electronics

Delta Electronics Planar DC/DC Transformer RM8 specification

RAM TUS404 user manual

RAM

RAM TUS404 user manual

Ortofon ST-80 SE instruction manual

Ortofon

Ortofon ST-80 SE instruction manual

Siemens GEAFOL Neo operating manual

Siemens

Siemens GEAFOL Neo operating manual

Uhlenbrock Elektronik 28000 manual

Uhlenbrock Elektronik

Uhlenbrock Elektronik 28000 manual

FONESTAR CV-1720 quick start guide

FONESTAR

FONESTAR CV-1720 quick start guide

Delta Electronics Current Sense Transformers TCE1906H specification

Delta Electronics

Delta Electronics Current Sense Transformers TCE1906H specification

Hobart 6T28-600CL Operation and maintenance manual

Hobart

Hobart 6T28-600CL Operation and maintenance manual

Shinkawa LS Series instruction manual

Shinkawa

Shinkawa LS Series instruction manual

Huawei JUPITER-3000K-H1 user manual

Huawei

Huawei JUPITER-3000K-H1 user manual

Monacor IMG STAGELINE LTR-102 manual

Monacor

Monacor IMG STAGELINE LTR-102 manual

Monacor PATL-100/XC instructions

Monacor

Monacor PATL-100/XC instructions

Lionel ZW instructions

Lionel

Lionel ZW instructions

Beckhoff SCT3 Series manual

Beckhoff

Beckhoff SCT3 Series manual

BRIDGEWERKS Mini Mag 3 user manual

BRIDGEWERKS

BRIDGEWERKS Mini Mag 3 user manual

Intermatic PX600S Installation, operation & service manual

Intermatic

Intermatic PX600S Installation, operation & service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

70.7 / 100V
Transformers
Power Rating:
60 Watts (T560-71);
100 Watts (T5100-71)
Frequency Response:
35 Hz to 15 kHz, ±0.5 dB
Total Harmonic Distortion:
< 0.5% at Rated Power, from
35 Hz to 15 kHz
Phase Response:
-15º to +35º
Insertion loss:
< 1 dB from 35 Hz to 15 kHz
(typically < 0.5 dB from 35 Hz
to 10 kHz)
Primary Taps:
4 Ωand 8 Ω
Secondary Taps:
70.7V and 100V
Hi-Pot: 500 VAC
T560-71/T5100-71
GENERAL PRODUCT DESCRIPTION
Altec Lansing is renowned for its high quality transformers.
The new Altec Lansing Professional transformers, T560-71
and T5100-71, are perfect complements to our premium
Duplex® Speakers when the prerequisite is high fidelity.
These transformers are designed for 70.7V or 100V distribution
of amplifier power, with minimal loss, to multiple loudspeakers.
True electrical isolation is provided to the source and the load
by the primary and secondary windings respectively. Installation
is simple with 0.25-inch blade type wire terminals, allowing
either solder connections or crimp type quick-connect wire
terminals.
FEATURES – THE ALTEC LANSING DIFFERENCE
• High Fidelity Transmission
• True Electrical Isolation
• Superior Efficiency
• Easily Installed
• Adaptable for use as either step-up
or step down line transformers
• Excellent choice for distributed systems featuring
Altec Lansing’s Premium Duplex® Speakers
PROFESSIONAl
1000 W. Wilshire Blvd., Suite 362 • Oklahoma City, Oklahoma 73116 • Phone: 1-405-848-3108 • Fax: 1-405-848-3217 • www.altecpro.com
T560-71
T5100-71
Length Width
3.75”
Height
3.50”
Hole
Center on
Length
3.39”
Hole
Center on
Width
3.00”
Hole
Dimension
0.25” x 0.35”
Winding
Thickness
4.06”
Core
Thickness
2.00”
Bracket
Thickness
0.063”
Weight
8 lbs.
Weights & measures
specifications
ARCHITECTS & ENGINEERS SPECIFICATION
The transformers shall be Altec Lansing Professional model numbers T560-71 and T5100-71, rated at 60 Watts and 100 Watts, respectively.
Their frequency response shall be 35 Hz to 15,000 Hz, ±0.5 dB. Throughout their 35 Hz to 15,000 Hz bandwidth, at rated power, they shall
produce no more than 0.5% T.H.D., and their insertion loss shall not exceed 1 dB. These transformers shall require no more than 10%
above their rated input power to deliver rated power to the load at 35 Hz. The T560-71 and T5100-71 shall provide true electrical
isolation to the source and to the load. Connection to these transformers shall be through 0.25-inch blade type wire terminals. The
nominal primary taps shall be 4 ohm and 8 ohm, and the nominal secondary taps shall be 70.7V and 100V.round white metal grille.E
E5475 REV01
© 2002 Altec Lansing Professional
1000 W. Wilshire Blvd., Suite 362
Oklahoma City, Oklahoma 73116
Phone: 1-405-848-3108 • Fax: 1-405-848-3217
Web: www.altecpro.com • Email: [email protected]
PROFESSIONAl
T560-71
T5100-71
4 Ohm
to 70 V
1:4.5
1:3.5
4 Ohm
to 100 V
1:6.4
1:5.0
8 Ohm
to 70 V
1:3.2
1:2.5
8 Ohm
to 100 V
1:4.6
1:3.5
4/8 term
to 70 V
1:10.9
1:8.5
4/8 term
to 100 V
1:15.4
1:12.0
voltage ratio
T560-71
T5100-71
4 Ohm
to 70 V
1:20.8
1:12.5
4 Ohm
to 100 V
1:41.7
1:25.0
8 Ohm
to 70 V
1:10.4
1:6.3
8 Ohm
to 100 V
1:20.8
1:12.5
4/8 term
to 70 V
1:21.9
1:13.1
4/8 term
to 100 V
1:44.0
1:27.0
impedance ratio
wiring diagram
COMMONCOMMON
4 Ω
70.7 V
100 V 8 Ω