Altinex CNK200 Cable-Nook User manual

CNK200 Cable-Nook®Interconnect Box User’s Guide
400-0111-009
1
Welcome!
Everyone at Altinex greatly appreciates your CNK200 purchase.
We are confident you will find it to be reliable and easy to use. If
you need support, do not hesitate to call at 714-990-2300.
At Altinex, we are committed to developing unique and state of
the art Signal Management Solutions®for demanding audiovisual
installations. Welcome to the Altinex family of satisfied customers
around the world!
1. Precautions and Safety Warnings
Please read this manual carefully before using your CNK200
Cable-Nook Interconnect Box. Keep this manual handy for future
reference. These safety instructions are to ensure the long life of
your CNK200 and to prevent fire and shock hazards. Please read
them carefully and heed all warnings.
1.1 General
•Qualified Altinex service personnel or their authorized
representatives must perform all service.
1.2 Installation
•For best results, place the CNK200 Cable-Nook in a dry
area away from dust and moisture.
•To prevent fire or shock, do not expose unit to water or
moisture. Do not place the CNK200 in direct sunlight, near
heaters or heat-radiating appliances, or near any liquid.
Exposure to direct sunlight, smoke, or steam can harm
internal components.
•Handle carefully; dropping or jarring can damage the unit.
•Never place fingers inside the openings in the back of the
unit as there are sharp edges inside.
•Do not place heavy objects on top of the CNK200.
•Install all cables according to the instructions.
1.3 Cleaning
•Clean surfaces with a dry cloth. Never use strong
detergents or solvents such as alcohol or thinner. Do not
use a wet cloth or water to clean the unit.
1.4 FCC Notice
•This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this
device must accept any interference received, including
interference that may cause undesired operation.
•This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency
energy and if not installed and used in accordance with
instructions found herein, may cause harmful interference to
radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in
which case the user will be required to correct the
interference at his own expense.
•Any changes or modifications to the unit not expressly
approved by Altinex, Inc. could void the user’s authority to
operate the equipment.
2. Installation Procedures
Warning: Altinex recommends using an experienced professional to make the table cutout. Before starting, go to the Altinex website
www.altinex.com and download the latest cutout requirements, templates, and detailed installation instructions.
Step 1. Cut an opening into the table for the CNK200. Use the template and measurements provided on the Altinex website. The
CNK200 is designed to fit tabletops 0.5 - 3.5 in (13-89 mm) thick.
Step 2. Insert the CNK200 into the table cutout and secure it to the table using
the brackets and thumb screws provided.
Step 3. When using retaining brackets to hold cables, adjust the retaining
brackets close enough together to prevent the cables from falling, but
loose enough to be pulled up easily. The cables should be long enough
to be pulled up through the CNK and reach the equipment.
Preconfigured or customizable sectional plate cables need only be long
enough to mate with the cables/connectors on the plates.
Step 4. If desired, bundle like cables together using a protective sheath, meshed
sleeve, etc. Leave the free ends of the cables long enough for making
connections to the equipment on the table.
Step 5. Route cables through the bottom of the unit to the top. Use clamps provided to neatly route/secure cables to the bottom of the
table.
3. Limited Warranty/Return Policies
Please visit the Altinex website at www.altinex.com for details on warranty and return policies. In the case of a unit needing repair,
please complete a RMA (return material authorization) form located on the bottom left hand corner of the Altinex homepage. Once

CNK200 Interconnect Box User’s Guide
400-0111-009
2
4. Technical Specifications
Specifications are subject to change. See www.altinex.com for up-to-date information.
Features/Description
CNK200s
CNK200
Interior Brackets
4-40, 0.25” spacing (x23)
CNK210
Interior Brackets
4-40, 0.25” spacing (x23)
Network
RJ-45 F (2)
HDMI Video
Type-A F (x1)
RGBHV Video (VGA)
15-pin HD F (x1)
Analog Stereo
3.5 mm F (x2)
USB Charging
Type-A, F (2)
Pass-through AC
9-10 ft. (2.7-3.0 m)
NEMA F (2) to M (1)
CNK212
Interior Mounting Brackets
4-40, 0.25” spacing (x23)
HDMI Video
Type-A F (1)
Network
RJ-45 F (2)
USB Charging
Type-A, F (4)
Pass-through AC
9-10 ft. (2.7-3.0 m)
NEMA F (2) to M (1)
Pass-through AC
9-10 ft. (2.7-3.0 m)
NEMA F (2) to M (1)
CNK240
Interior Brackets
4-40, 0.25” spacing (x23)
Retaining Rails
4.5” x 0.4” (x5)
Pass-through AC
9-10 ft. (2.7-3.0 m)
NEMA F (2) to M (1)
CNK260
Interior Brackets
4-40, 0.25” spacing (x23)
Retaining Grommet
0 .45” I.D. (x6)
Pass-through AC
9-10 ft. (2.7-3.0 m)
NEMA F (2) to M (1)
Table 1. Cable-Nook General
Mechanical
CNK200s
All CNK200’s
Minimum Table Thickness
0.5 in (13 mm)
Maximum Table Thickness
3.5 in (89 mm)
Height (above surface)
4.0 in (102 mm)
Height (below surface)
4.8 in (122 mm)
Bezel Dimensions (surface)
Width
7.9 in (200 mm)
Depth
6.5 in (166 mm)
All CNK200’s
Standard Finish
Matte Black
Alternative Finish
Brushed Aluminum
TOperating
10C-35C
TMaximum
50C
Humidity
90% non-condensing
Table 2. Cable-Nook Mechanical
Electrical
CNK200s
CNK210 and CNK212
USB Charging
7.5W Each port
CNK210, CNK212, CNK240, CNK260
Power Rating
(pass=through AC power)
120VAC, 60Hz,
12A Total Current
(per dual outlet module)
Table 3. Cable-Nook Electrical

CNK200 Interconnect Box User’s Guide
400-0111-009
3
MOUNTING BRACKET
ACCESS DOOR
BEZEL
HOUSING
SUPPORTS ADJUSTABLE
SHELF HOLES
SAMPLE CONFIGURATION:
RETAINING BREACKETS
and CUSTOM PLATES
5. About Your CNK200
•Installs easily into tabletop
•Convenient access to cables
•Simple, cost-effective interconnect solution
•Fits table surfaces 0.5 - 3.5 in (13 - 89 mm) thick
The CNK200 is a simple, effective way of hiding/storing multimedia cables and connectors and is designed for boardrooms and
conference rooms. Cables remain connected to a presentation system enabling the user to access connections to AC power, video,
audio, and other media sources.
The CNK200 Cable-Nook is designed for use with tables ranging from half an inch to 3.5 in thick. The height of the interior shelf can
also be adjusted for different depths. The CNK200 comes in a standard matte black color; the CNK200S is brushed aluminum.
The CNK200 sectional plates allows for diverse connector configurations. Available plates include combinations of audio, video,
computer, and AC power connectors, providing extensive flexibility in a convenient package. The sectional plates connect permanently
to the presentation system.
CNK200 with CN5000 and CNK-IP-100 Series Plates
The cables connect to the presentation system underneath the surface and are accessed from the CNK200 by either pulling the cables
up and out of the top of the unit (using retaining brackets) or by plugging external cables into sectional plates installed in the CNK200.
Retaining brackets secure cable ends where the brackets can be adjusted to fit a wide variety of cable sizes. Cables are pulled out
from the top of the CNK200 when needed and then fed back down under the table when no longer required. The weight of the cables
helps to feed the slack through the unit and the cable ends are kept from falling by the retaining brackets.
CNK200 with 210 Series Plates
The 210 Series sectional plates allow for the same diverse connector configurations and are available in various combinations of audio,
video, computer, and AC power connectors, providing extensive flexibility in a convenient package. The sectional plates have bulkhead
style connectors and connect permanently to the presentation system. See Diagram 5 on page 8 for more details.
CNK200 Series Preconfigured Systems:
The CNK210, CNK212, CNK240, and CNK260 are preconfigured systems that cover most applications. See the diagrams in the
following pages for details and descriptions.
CNK210
CNK212
CNK240
CNK260

CNK200 Interconnect Box User’s Guide
400-0111-009
4
6. Application Diagrams
Diagram 1: Typical Setup

CNK200 Interconnect Box User’s Guide
400-0111-009
5
Diagram 2: Dimensions Top and Front
6.0"
[153 mm]
4.7"
[119 mm]
6.5"
[166 mm]
7.9"
[200 mm]

CNK200 Interconnect Box User’s Guide
400-0111-009
6
Diagram 3: Side View Dimensions
4.7"
[119 mm]
5.3"
[134 mm]
3.9"
[100 mm]
4.7"
[119 mm]
6.0"
[153 mm]

CNK200 Interconnect Box User’s Guide
400-0111-009
7
Diagram 4: Twenty-Three (23) Hole Sets
The CNK200 can be customized for virtually any configuration required. Inside, there are 23 hole sets available for installing
preconfigured plates, customizable plates, or retaining brackets for holding cables.
In some cases, it is desirable to have the cables reside in the Cable-Nook instead of requiring the user to provide their own cables. In
this case, retaining brackets can be positioned to keep cables installed under the table from falling below the Cable-Nook’s interior
shelf. The user simply pulls out the cable(s) needed and connects them to a laptop, iPod, etc.
Shown below are some typical plate options with retaining brackets. See our website at www.altinex.com for a complete list of available
plates and customizable snap-in connectors.
23 HOLE SETS
WITH LID OPEN
TOP INSIDE VIEW
RETAINING
BRACKETS
PLATES
POWER
CUSTOMIZABLE
SNAP-IN PLATES
TO HOLD CABLES
STANDARD
PLATES

CNK200 Interconnect Box User’s Guide
400-0111-009
8
Diagram 5: The 210 Series Option
The CNK-IP-210 Series plates do not use the hole sets that the CN5000 and CNK-IP-100 Series plates used. Instead, the hole set rails
are removed and the CNK-IP-210 is mounted directly to the CNK200 chassis. The CNK-IP-210 has three openings that can
accommodate different configurations of power, audio, video, and control interfaces.
The video, audio, and snap-in connectors are bulk-head style connectors. The bottom (or inside) connectors connect to off-the-shelf
cables which connect permanently to the presentation system.
Shown below is the blank CNK-IP-210 as well as a standard configuration plate. In the example below, the SP3504SC standard
configuration is shown. This plate provides AC power, dual AC charging ports, video and audio connectors for both VGA and DIGITAL
video. Additionally, this plate has 6 blank snap-in ports that can be populated using your own snap-ins or you can purchase custom
snap-ins from Altinex. See our website at www.altinex.com for a complete list of available plates and customizable snap-in connectors.

CNK200 Interconnect Box User’s Guide
400-0111-009
9
Diagram 6: The 212 Series Option
The CNK-IP-210 Series plates do not use the hole sets that the CN5000 and CNK-IP-100 Series plates used. Instead, the hole set rails
are removed and the CNK-IP-210 is mounted directly to the CNK200 chassis. The CNK-IP-210 has three openings that can
accommodate different configurations of power, audio, video, and control interfaces.
The CNK212 is a complete preconfigured CABLE NOOK. It has a black brushed aluminum finish and includes the following:
1X CNK-IP-210 Face plate for CNK-IP-2xx
2X CNK-IP-200 Single Gang Dual Power, Dual USB
1X CNK-IP-217 Panel Mount HDMI + 4 Port Snap-In Plate
2X SN1318-RJ45-B RJ-45 F/F Snap-In Connector
Additionally, there are 2 extra snap-in locations available for further customization.
See our website at www.altinex.com for a complete list of available plates and customizable snap-in connectors.

CNK200 Interconnect Box User’s Guide
400-0111-009
10
Diagram 7: The 240 Series Option
The CNK240 is a complete preconfigured CABLE NOOK. It is a modular configuration with room for additional connectors. The
CNK240 is a simple and cost-effective solution for cable access. The CNK has a black brushed aluminum finish and includes the
following:
1X CN5008US US Power module
1X CN5010RB Retaining brackets (x5)
Shown below is the CNK240 as shipped. The power module is the CN5008US and is UL Listed. The retaining brackets may be
adjusted to accommodate any number of cable types. The brackets should be adjusted to prevent the cables from slipping under the
table, but loose enough to allow the user to easily pull up the cables.
See our website at www.altinex.com for a complete list of available plates and customizable snap-in connectors.

CNK200 Interconnect Box User’s Guide
400-0111-009
11
Diagram 8: The 260 Series Option
The CNK260 Cable Nook provides a simple yet effective way of hiding and storing multimedia cables and fixed connectors. The cables
remain connected to a presentation system, enabling the user easy access to them and for connection to video, audio, and other media
sources needed.
1X CN5008US US Power module
1X CN5020RG Retaining grommets (x6 access points)
Shown below is the CNK260 as shipped. The power module is the CN5008US and is UL Listed. The retaining brackets/grommets
accommodate various cables up to half an inch in diameter.
CNK260 is also ideal for use with Altinex retractable cables:
RT300-121 VGA M-M Retractable Cable
RT300-125 HDMI M-M Retractable Cable
RT300-134 3.5 mm M-M Retractable Cable
RT300-145 RJ-45 M-M Retractable Cable
See our website at www.altinex.com for a complete list of available plates and customizable snap-in connectors.

CNK200 Interconnect Box User’s Guide
400-0111-009
12
Diagram 9: Mounting

CNK200 Interconnect Box User’s Guide
400-0111-009
13
7. Operation
7.1 Accessing the CNK200
The CNK200 cover opens easily and remains open until all the
cables are connected. The cover should be closed with the
cables routed through the curved opening to prevent damage
to the unit and to prevent liquids from entering the opening.
Additionally, the cover should be closed when not in use to
prevent liquids or other debris from damaging the unit.
7.2 Power/Signal Connections
Connect external devices to the appropriate connector from the
CNK200. Remember, the devices plugged into the AC power
connectors should not draw more than the rated values of the
cables and/or circuit.
8. Troubleshooting Guide
The CNK200 supplied was carefully tested and no problems were detected. However, we would like to offer the following suggestions:
CNK200 Series
Symptom
Resolution
No Display
1. Check the source and make sure there is a signal present.
2. Make sure the monitor has power and is turned on.
Poor Output Image
1. The source resolution may not be compatible with the projector or other display device. Try
other resolutions from the source.
2. The source and display may not be compatible. Connect the source directly to the input of the
projector or other display device. If the image is poor the devices may be incompatible.
Don’t know the IP
address
1. Please make sure that the highest quality network cables are used.
2. Make sure that no cable or power cord is damaged or pinched. If there has been damage, do
not use the CNK200. Please call the Altinex Customer Service Department at (714) 990-2300 to
have the unit repaired.
System Failure
Please call the Altinex Customer Service Department at (714) 990-2300 to have the unit repaired.
Other manuals for CNK200 Cable-Nook
1
This manual suits for next models
4
Table of contents
Other Altinex Enclosure manuals