Altronics HubWayH16 User manual

Rev. 121710
Passive UTP Transceiver Hub
Installation Guide
Models Include:
HubWayH16
- Sixteen (16) Camera Channels
More than just power.TM
Video • Data

- 2 - HubWayH Passive Hub Unit
Overview:
Altronix HubWayH16 Passive UTP Transceiver Hub transmits UTP video, RS422/RS485 data over a single CAT-5 or higher
structured cable. Unit provides 16 camera channels in a space saving 1U EIA 19” rack mount chassis. Video transmission
range is up to 750 ft. max. per channel. Units are compatible with fixed cameras or PTZs.
Specifications:
Video:
• Sixteen(16)channelsofvideoovertwistedpairupto
a distance of 750 ft. per channel.
• Sixteen(16)75ohmvideooutputs.
Data:
• RS422/RS485datainputs.
Features:
• 1UrackmountchassisforuseinstandardEIA19”rack.
Accessories:
• HubWayAv2 - Interfaces with all HubWay and HubSat
UTP Transceiver Hubs for 24VAC/12VDC fixed
camerasorPTZs(basedonpowersupplyrating).
• HubWayAvP - Interfaces with HubWayH16 Passive
UTP Transceiver Hub for 24VAC/12VDC fixed
cameras(basedonpowersupplyrating).
Installation Instructions:
1. Secure the unit in a rack (Fig. 5, pg. 6) (unitshouldbespacedatleast3”fromanyvideomonitors).
2. Connect the BNC video outputs for HubWayH16 Channels 1-16 to the corresponding video inputs on the head end
equipment(DVR)(Fig. 1d, pg. 3).
3. Connectexternalpowersource(ACorDCpowersupply)totheindividualchannelterminalsmarked[Power]
(Fig. 1b, pg. 3).
Connecting Fixed Cameras (Fig. 3a, pg. 5):
1. SetswitchofthecorrespondingchannelontherearofHubWayH16to[PWR](Fig. 1e, pg. 3).
Warning:ToavoidequipmentdamagedonotconnectPTZstochannelsselectedforPOWER(PWR)only.
2. Connect HubWayAvP Video Balun/Combiner at camera to the HubWayH16 unit utilizing CAT-5 or higher structured
cable.PlugtheRJ45connectoratoneendofthestructuredcableintotheRJ45jackmarked[Channel1-16]ofthe
HubWayH16 (Fig. 1c, pg. 3). Plug the RJ45 connector at the opposite end of the structured cable into the RJ45 jack
of the Video Balun/Combiner located at the camera (Fig. 2a, pg. 4).
Note:Repeatsteps1-2foreachadditionalfixedcamera(Channels2-16).
Connecting PTZ Cameras (Fig. 3b, pg. 5):
1. ConnecttheRS422/RS485outputoftheheadendequipment(DVR)totheindividualterminalsmarked[+DATA---]
of the HubWayH16unit(polaritymustbeobserved)(Fig. 1a, pg. 3).
Note: The Data input terminals of the HubWayH16 must be wired in parallel for proper operation.
2. SetswitchofthecorrespondingchannelontherearofHubWayH16to[PWR/DATA](Fig. 1e, pg. 3).
3. ConnectHubWayAv2VideoBalun/CombineratcameratotheHubWayH16unitutilizingCAT-5orhigherstructured
cable.PlugtheRJ45connectoratoneendofthestructuredcableintotheRJ45jackmarked[Channel1-16]ofthe
HubWayH16 (Fig. 1c, pg. 3). Plug the RJ45 connector at the opposite end of the structured cable into the RJ45 jack
of the Video Balun/Combiner located at the camera (Fig. 2b, pg. 4).
Note:Repeatsteps1-3foreachadditionalPTZcamera(Channels2-16).
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture.
This installation should be made by qualified service personnel and should conform to all local codes.

HubWayH Passive Hub Unit - 3 -
CHANNEL
DATA
+ ---
DATA
+ ---
DATA
+ ---
DATA
+ ---
POWER CHANNEL POWER POWER POWER DATA
+ ---
POWER DATA
+ ---
POWER DATA
+ ---
POWER DATA
+ ---
POWER
1 4
9 12
5 8
13 16
CHANNEL CHANNEL CHANNEL CHANNEL CHANNEL CHANNEL
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
8765 4 3 2 1
16 15 14 13 12 11 10 9
1a - Data Input: RS422/
RS485 input from head
endequipment(DVR)
for PTZ control.
1d - BNC
Connector: Video
outputs to head end
equipment(DVR).
1e - Individual Power
& Data or Power
Switches: Video
outputs to head end
equipment(DVR).
1b - Individual Power
Input: External AC or
DC power input. 1c - Channels 1-16: CAT-5
or higher structured cable to
Video/Balun Combiners at
cameras 1-16.
Fig. 1
Front
Rear

- 4 - HubWayH Passive Hub Unit
Fig. 2
Video Balun/Combiners:
Video from Camera
Data to Camera
Power to Camera
Cat5
back to
HubWay or
HubSat
Video from Camera
Power to Camera
Power to Camera
Cat5
back to
HubWayH16
Red
Power
LED
Data to
Camera
--
+
12VDC Power
to Camera
+
--
To BNC
Connector
of Camera
Structured
Cable from
HubWayH16
RJ45 Jack Wire
Connectors
Refer to the HubWay Video Balun/Combiner
Installation Guide Rev. 123008
12VDC
-- +RJ45 DATA
+ --
VIDEO Commercial
CCTV Accessory
3C03
HubWayDv VIDEO BALUN/COMBINER
Fig. 2a
Fig. 2b
Fig. 2c

HubWayH Passive Hub Unit - 5 -
HubWayH16
Front Panel
Connections
HubWayH16
Rear Panel
Connections
Video/
Power
Video Balun
Combiner
CAT-5
12VDC or
24VAC Fixed
Camera
External Rack Mount
12VDC or 24VAC
Power Supply
Head end
Equipment (DVR)
DATA
+ ---
POWER CHANNEL
1 4
PWR
DATA PWR
1
HubWayH16
Front Panel
Connections
HubWayH16
Rear Panel
Connections
Video/
Data/
Power
Video Balun
Combiner
CAT-5
External Rack Mount
12VDC or 24VAC
Power Supply
Head end
Equipment (DVR)
Head end
Equipment (DVR)
DATA
+ ---
POWER CHANNEL
1 4
PWR
DATA PWR
1
12VDC or
24VAC
PTZ
Camera
Fig. 3
Fig. 3a
Fig. 3b
Typical Application:

- 6 - HubWayH Passive Hub Unit
CHANNEL
DATA
+ ---
DATA
+ ---
DATA
+ ---
DATA
+ ---
POWER CHANNEL POWER POWER POWER DATA
+ ---
POWER DATA
+ ---
POWER DATA
+ ---
POWER DATA
+ ---
POWER
1 4
9 12
5 8
13 16
CHANNEL CHANNEL CHANNEL CHANNEL CHANNEL CHANNEL
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
PWR
DATA PWR
8765 4 3 2 1
16 15 14 13 12 11 10 9
17.10”
(434.34mm)
19.0”
(482.6mm)
1.696”
(43.08mm)
1.696”
(43.08mm)
2.498”
(63.45mm)
3.0225”
(76.77mm)
Rack Mount Chassis Mechanical Drawing & Dimensions (H x W x D approximate):
1.625” x 19.125” x 2.498”(41.3mmx486mmx63.5mm)
TOP & BOTTOM
REAR
FRONT
The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the
presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient
magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important
operatingandmaintenance(servicing)instructionsintheliteratureaccompanyingtheappliance.
CAUTION: To reduce the risk of electric shock do not open enclosure. There
are no user serviceable parts inside. Refer servicing to qualified service personnel.
Rack Mount Installation:
1- Place unit into desired EIA 19” rack position and secure with mounting screws (not included) (Fig. 5).
Fig. 5
Fig. 4

HubWayH Passive Hub Unit - 7 -
Notes:

Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
IIHubWayH16 E20N
- 8 - HubWayH Passive Hub Unit
MEMBER
Notes:
Table of contents
Popular Security System manuals by other brands

Siemens
Siemens IGS6-10 user manual

FBII
FBII OMNI-848EU user guide

iSmartAlarm
iSmartAlarm Home Security System owner's manual

Brink's Home Security
Brink's Home Security BHS-2000B owner's manual

Digital Alert Systems
Digital Alert Systems DASDEC-III Hardware installation guide

Velleman
Velleman DWH Series Installation and operation instruction manual

SEON
SEON Trooper Basic TR1-10 Quick reference guide

Radionics
Radionics D7212 owner's manual

AEI Security & Communications
AEI Security & Communications CTVM300AWK user guide

AVS Electronics
AVS Electronics VECTOR Plus installation manual

KALEAS
KALEAS KlimaDetector operating instructions

Magos
Magos SR-500 user manual