Component Testing Procedures
!WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless
testing requires power.
36-32089701-0 October 2001
2
Illustration Component Test Procedure Results
31823701
Oven light socket Remove one wire from receptacle
and test resistance of terminals.
Measure voltage at oven light.
Indicates continuity with bulb screwed in.
120 VAC, see wiring diagram for terminal
identification.
If no voltage is present at oven light, check
wiring or light switches.
31722801
Oven indicator light
and
Surface indicator light
Remove one lead from switch
terminal and measure resistance
across terminals.
Measure voltage at indicator light.
Switch closed: 0 Ω
Switch open: Infinite resistance
If voltage is present and light does not
operate. Replace light.
If no voltage is present at indicator light
check wiring.
31938901−1200 W
31939001−1500 W
31939101−2000 W
31939201−2500 W
Ribbon radiant
elements, limiters are
not replaceable.
Remove one wire lead from element
and measure resistance of the
element.
Verify supply voltage
Continuity, if not replace.
1200W: 44 to 49 ΩApproximately
1500W: 36 to 40 ΩApproximately
2000W: 26 to 30 ΩApproximately
2500W: 20 to 23 ΩApproximately
240 VAC
31926701
31926702
31926703
Infinite switch Remove wiring from terminals H1
and H2. Connect Volt ohms meter to
H1 and H2.
Measure the following for voltages at
LO, MED, HI:
H1 to H2
Time On Time Off
LO 5% 95%
MED (4-5) 50% 50%
HI 100% 0%
240 VAC, if not replace switch.
32078201
Control limit
Normally Closed
Verify proper operation.
Closed............ 215°F......................
Open .............. 245°F......................
If open at room temperature, replace.
Continuity
Infinite
31967101
Bake element Disconnect wire leads to element
and measure resistance of terminals.
Measure voltage at bake element.
Continuity, approximately 20 Ω,
if not replace.
240 VAC, see wiring diagram for terminal
identification.
If no voltage is present at bake element
check wiring.
31967302
Broil element Disconnect wire leads to element
and measure resistance of terminals.
Measure voltage at broil element.
Continuity, approximately 19 Ω,
if not replace.
240 VAC, see wiring diagram for terminal
identification.
If no voltage is present at broil element
check wiring.
31954301
Oven temperature
sensor
Measure resistance.
Approximately 1100 Ωat room
temperature 75°F.
31946302
Hinge
CAUTION
!
Do not place hands in hinge area when
oven door is removed. Hinge can snap
closed and pinch hands or fingers.
https://appliancetechmanuals.com