4
Mounting Sensor/Door Magnet Installation
for DD01E and DD01F Kits
DD01E and DD01F must be mounted on the top door frame
as close to the door as possible in the horizontal position.
ADT01*mustbeinstalledinthePTACunitfortheDD01Eor
DD01Fto be operable.
Skip these steps if not installing.
1. Remove motion sensor from mounting plate by pulling
apart.
2. Mount the back plate on the door trim directly above
the door using the enclosed screws. (Position so the UP
arrow is pointing up.) Mount the DD01E as low as pos-
sible on the door frame to be as close to the moving
part of the door as possible without interfering with
thedoor opening orclosing. Choosealocation formount-
ing the back plate that will provide good coverage of
the PIR for motion into the room. Make sure that the
DD01E will not interfere with the normal opening and
closing of the door.
DO NOT SNAP MOTION SENSOR IN PLACE UNTIL AFTER
BINDING PROCESS.
See Binding Instructions, page 10.
DOOR
DOOR TRIM
(CENTER MAGNET WITH 01*)DD
DD01*
DD01E and DD01F Mounting
3. Install two (2)AAbatteries (included) into the back of
the sensor.Terminals are marked “+” and “-” for polar-
ity. Do NOT put batteries into the device untilAFTER
the magnet location is selected to test.
WIRED MAGNET AND POWERED DOOR
SENSOR OPTION
In cases where there is no top door frame, the sensor will
needtobemounted on the wall next to the door. In these
cases a wired magnet (a field supplied single pole single
throwwired magnet) canberecessed or surfacemounted
andwiredtothedoorsensor.Themagnetwillbearecessed
style magnet with wired switch. The wires for the sensor
(20gaugefieldsupplied)inthemagnetwillneedtoberun
during construction. Two wires will be run from the door
sensorlocationto the PTAC unit; theremainingtwowires
willberunfromthemagnetlocationtothesensorlocation.
The door sensor has four (4) terminal locations for wired
powerand/orwiredmagnets.Thetwo(2)terminalsclosest
tothebindingbuttonareforwiredmagnetandthetoptwo
(2) terminals are for wired power.
Runthemagnetwiresthroughtheopeninginthecenterof
thedoor sensor wall plate.
CONNECTING MAGNET
Usinga pocket size straight blade screw driverpushdown
ontheterminalbuttontoopenthesocket,insertwireinto
socketandreleasetheterminalbutton.Insertonewireinto
eachofthetwo(2)terminals.Seefollowingimageforwire
locations.
POWER CONNECTION
Ifusingthewiredpoweredoptionforthedoorsensor,using
apocketsizestraightbladescrewdriver,pushdownonthe
terminalbuttontoopenthesocket.Insertwireintosocket
andreleasetheterminalbutton.Insertonewireintoeach
ofthe two (2) terminals. See followingforwire locations.
ConnectthepowerwiresfromthedoorsensortothePTAC
on terminals C & R. The wire harness kit PWHK01C is
requiredforthis connection.