The transformer delivers dual output 110V and 220V simultaneously!
Do not plug the appliance into the wrong outlet of the transformer!
Otherwise the appliances might be damaged.
5. OPERATION OF THE TRANSFORMER
a. Connect the electrical appliances to the transformer
(1) Check the specifications of the appliance(s), make sure the total starting power does not
exceed the maximum capacity of the transformer.
(2) Make sure all appliance(s) are turned “OFF” before connection.
(3) Connect the appliance(s) to the transformer.
If the input voltage of appliance(s) is 110-120V, connect it (them) to the 110V outlet of the
transformer. If it is 220-240V, then connect it (them) to the 220V outlet.
b. Connect transformer to mains supply
Plug the input plug of transformer into the wall socket.
c. Switch on the transformer
(1) Press the power switch to “ON” position and GREEN LED will light up.
(2) Switch “ON” the appliance(s).
d. When circuit breaker trips off
(1) If circuit breakers trips off, it means the transformer is over-loaded, or a short circuit happens
inside the transformer or inside the appliance(s).
(2) Switch off the transformer, unplug it from the wall socket, unplug the appliance(s)
from the transformer.
(3) Reset the circuit breaker, plug it again into the wall socket, then switch it on to check if the
transformer is ok or not.
4. SPECIFICATION
Operating Temperature: -10ºC ~ 40 ºC
Storage Temperature: -15ºC ~ 45 ºC
Operating Humidity: <90%, non-condensing
Model Number AT-502-500VA AT-502-1000VA
Maximum Capacity
@ Input 220-240V
Maximum Capacity
@ Input 110-120V
500 Watts
500 Watts
1000 Watts
1000 Watts
Input Voltage
Output Voltage
Protection Class
IP Level
Enviromental
Machine Size
Efficiency
LED Indicator
Protection
110Vac or 220Vac
220Vac or 110Vac
I
>96%
Green LED: Power On
Red LED: Protection (Output is cut off)
Short Circuit Protection: Circuit Breaker Trip Off
High Voltage Cutoff: Output is Cut Off
Low Voltage Protection: Output is Cut Off
Coil Overheating Protection: Output is Cut Off
235x146.2x115mm
3. PRODUCT VIEW
2. FEATURES
● Automatic step up & step down voltage converting, no need manual selecting input voltage.
Dual output 110V and 220V simultaneously. The converted voltage is from the transformer, ●
the same voltage is directly connected to mains supply.
Low voltage protection and automatic resume.●
● High voltage protection and automatic resume.
Transformer coil overheat protection and automatic resume.●
Short circuit protection.●
1.PACKING CONTENT
Voltage Transformer...........1pc
User’s Manual....................1pc
a. Front view of the transformer
AT-502-500VA~1000VA
Red LED: “Protecting” Indicator
Green LED: “Power On” Indicator
230V Outlet
b. Rear view of the transformer
Rear of AT-502-500VA~1000VA
Surge protection.●
AC Input
235x146.2x115mm
110V Outlet