Amazone EasySet 2 User manual

Operating Manual
az
EasySet 2
Control computer
for
ZA-M ZA-V ZA-X
MG6764
BAG0217.9
06.22
Printed in Germany
Please read this operating
manual before initial operation.
Keep it in a safe place for future
use!
en

2
EasySet 2 BAG0217.9
06.22

Table of Contents
EasySet 2
BAG0217.9 06.22
3
1Product description .....................................................................................4
1.1 Overview ..................................................................................................................................4
1.2 Display .....................................................................................................................................4
1.3 Adjustment buttons ..................................................................................................................5
1.4 Buttons for operation................................................................................................................6
2Preparing the EasySet2...............................................................................7
2.1 Switching the EasySet2 on and off ..........................................................................................7
2.2 Enter spread rate .....................................................................................................................7
2.3 Entering working width.............................................................................................................8
2.4 Determining/entering the fertiliser calibration factor ................................................................8
2.5 Simulated speed / distance sensor ........................................................................................12
2.5.1 Calibrating the distance sensor (pulses per 100 m) ..............................................................14
2.5.2 Setting the simulated speed...................................................................................................15
3Using the EasySet2....................................................................................16
3.1 Spreading fertiliser .................................................................................................................16
3.2 Performing boundary spreading ............................................................................................18
3.3 Spreading slug pellets and fine seeds ...................................................................................20
3.4 Displaying the area efficiency ................................................................................................21
3.5 Performing residual emptying ................................................................................................21
4Connection .................................................................................................22
5EasySet 2 configuration ............................................................................23
5.1.1 Calibrating the shutters ..........................................................................................................24
5.2 Error messages......................................................................................................................28
6Overview..................................................................................................... 30

Product description
4
EasySet 2 BAG0217.9
06.22
1 Product description
1.1 Overview
(1) Switch On and Off button
After being switched on, the display shows
the set shutter position
(2) Adjustment buttons
Some with LED light for showing the acti-
vated function
(3) Buttons for control during operation
Some with LED light for showing the acti-
vated function
(4) Display with LED lights
1.2 Display
•Display for showing a maximum of 6 char-
acters
•LED lights above the display show the units
of the displayed value.

Product description
EasySet 2
BAG0217.9 06.22
5
1.3 Adjustment buttons
•Adjust the spread rate
•
Adjust the working width, according
to the setting chart and spreading disc
•Determine / set the calibration
factor
•Select the simulated speed. Cali-
brate the distance sensor, enter the pulses
per 100 m.
•Display of the daily output in ha
→Press and hold the button to reset the daily
output
•No function!
The LED lights show the selected setting.
Changing the setting values
In the active Setting menu, the setting values can
be changed using the marked +/- buttons.
By pressing and holding the +/- buttons, the val-
ue changes rapidly.
Set values are automatically saved.
Go back from the Setting
menu to the work display using the
100% button.

Product description
6
EasySet 2 BAG0217.9
06.22
1.4 Buttons for operation
Open/close both shutters
Open/close left shutter
Open/close right shutter
Higher rate
Higher rate on the left
Higher rate on the right
Reset rate to 100%
Lower rate on the left
Lower rate on the right
Lower rate
Raise limiter electrically
Activate limiter
Lower limiter electrically
•LEDs (if equipped) show the selected function.
•By pressing and holding the +/- buttons, the value changes rap-
idly.
•Set values are automatically saved.

Preparing the EasySet2
EasySet 2
BAG0217.9 06.22
7
2 Preparing the EasySet2
2.1 Switching the EasySet2 on and off
Switch on the EasySet2.
→The current software version is shown for 2
seconds.
→The set mode is shown for one second.
→The Work display appears.
Switch off the EasySet2.
→STOP is shown for 2 seconds.
→The total area efficiency is shown for 2 sec-
onds.
2.2 Enter spread rate
1. Select the spread rate setting.
→
The spread rate is shown in kg/ha.
2. , Enter the spread rate.
3. Save the value and go back to the
work display.

Preparing the EasySet2
8
EasySet 2 BAG0217.9
06.22
2.3 Entering working width
1. Select the working width setting.
→
The working width is shown in m.
2. , Enter the working width.
3. Save the value and go back to the
work display.
2.4 Determining/entering the fertiliser calibration factor
The fertiliser calibration factor determines the regulating behaviour of
the implement computer and depends on the flow characteristics of
the fertiliser to be spread.
In turn, the fertiliser flow characteristics depend on:
•fertiliser storage, storage time and climatic factors.
•working conditions.
•The fertiliser calibration factor can be found in the setting chart
for each fertiliser.
•Use the fertiliser calibration factor from the setting chart as a
base value before calibration.
•The value of the setting chart is optimised by calibrating the
fertiliser.
•The determined fertiliser calibration factor overwrites the value
from the setting chart.
Realistic calibration factors for fertiliser (0.7 to 1.4):
•0.7 for urea
•1.0 for calcium ammonium nitrate (CAN)
•1.4 for fine, heavy PK fertilisers

Preparing the EasySet2
EasySet 2
BAG0217.9 06.22
9
Entering the fertiliser calibration factor
If the fertiliser calibration factor is known, it can
be entered directly.
Select calibration.
→The calibration factor will be displayed.
4. , Set the calibration factor.
5. Save the value and go back to the
work display.
Determining the fertiliser calibration factor with the left shutter
1. Prepare for fertiliser calibration using the
left shutter,
refer to the implement operating
manual.
2. Arbeitsbreite und Ausbringmenge eingeben.
3. Select calibration.
4. Enter the calibration value as a base value.
5. Press and hold the button for 6
seconds.
→The calibration routine starts.
6. Open the left shutter.
→The calibration time is shown.
3. Close the left shutter as soon as
enough spreading material has been col-
lected.
οFertiliser: Fill the collection bucket
completely.
οSlug pellets and fine seeds: Collect
approx. 5 kg.
→The theoretically spread fertiliser quantity is
shown in kg.

Preparing the EasySet2
10
EasySet 2 BAG0217.9
06.22
8. Weigh the collected fertiliser quantity.
9. , Overwrite the theoretical
fertiliser quantity with the collected fertiliser
quantity.
10. Terminate the calibration.
→The new calibration factor will be displayed.
By switching off the device, the
calibration will be discarded.
11. Save the value and go back to the
work display.

Preparing the EasySet2
EasySet 2
BAG0217.9 06.22
11
Determining the fertiliser calibration factor with the lateral calibration device
See also operating manual for the implement.
1. Perform a spread rate check with the lateral
calibration device.
2. Enter the collected quantity of fertiliser and
the required time in the calculation formula
and calculate the calibration factor.
Enter the calibration factor:
3. Select calibration.
→The calibration factor will be displayed.
4. , Set the calibration factor.
5. Save the value and go back to the
work display.
Formula to calculate the calibration factor:
ZA-M:
Calibration factor =
2.2 x
Collected fertiliser quantity [kg]
Time [s]
ZA-V:
Calibration factor =
0.65 x
Collected fertiliser quantity [kg]
Time [s]
ZA-X:
Calibration factor =
1,89 x
Collected fertiliser quantity [kg]
Time [s]

Preparing the EasySet2
12
EasySet 2 BAG0217.9
06.22
2.5 Simulated speed / distance sensor
Select .
→Depending on the last entered setting, the
value for the pulses per 100 m or the value
for the simulated speed will be displayed.
Pulses per 100 m display:
→Possible values from 250 to 350.
Display of the simulated speed:
→Possible values from 2 to 30 km/h.
Switching from the distance sensor to the
speed simulator
Shutter must be closed.
1. Press until the distance sensor
display reaches 250 (pulses).
2. Press until the display changes
from 250 (pulses) to 12 (km/h).
→The desired speed can now be entered.
→Speed simulator active
→Speed-proportional metering not active

Preparing the EasySet2
EasySet 2
BAG0217.9 06.22
13
Switching from the speed simulator to the
distance sensor
Shutter must be closed.
1. Press until the speed
simulator display reaches 30 (km/h).
2. Press until the display changes
from 30 (km/h) to 250 (pulses).
→The pulses per 100 m can now be entered.
→Speed-proportional metering active
→Speed simulator not active

Preparing the EasySet2
14
EasySet 2 BAG0217.9
06.22
2.5.1 Calibrating the distance sensor (pulses per 100 m)
The on-board computer needs the "Pulses per 100 m" calibration
value to
•determine the actual forward speed [km/h].
•the worked area.
If the calibration value is not known, it must be determined by means
of a "Pulses per 100 m" calibration run.
You can enter the "Pulses per 100m" calibration value manually in the
if the precise calibration value is known.
Always determine the precise calibration value for "Pulses per 100 m"
by means of a calibration run:
•before initial operation.
•when using a different tractor or after changing the tractor tyre
size.
•if there are differences between the measured and actual for-
ward speed / distance travelled.
•if there are differences between the measured and actual
worked area.
•if there are different soil conditions.
The "Pulses per 100 m" calibration value must be determined under
the prevailing operating conditions. If operation is carried out with all-
wheel drive switched on, you must also switch on the all-wheel drive
when determining the calibration value.
Entering the pulses per 100 m
1. Select the distance sensor.
→The pulses per 100 m will be displayed.
2. , Enter the pulses per 100
m, if known.
3. Save the value and go back to the
work display.

Preparing the EasySet2
EasySet 2
BAG0217.9 06.22
15
Determining the pulses per 100 m
1. Measure a calibration distance of exactly
100 m.
2. Mark the start and end points.
3. Drive up to the starting point.
4. Press and hold the button for 6
seconds.
→The display flashes.
5. Drive the calibration distance of exactly 100
m.
→The pulses are being counted.
6. Stop.
→The determined value for the pulses per
100 m is displayed.
→The display flashes.
7. Confirm the value and go back to
the work display.
2.5.2 Setting the simulated speed.
Selecting a simulated speed enables working with the implement
without a speed signal (distance sensor / pulses per 100 m).
The forward speed must correspond to the simulated speed during
operation. Otherwise, the correct spread rate will not be achieved.
1. Select the simulated speed.
If the distance sensor display (values greater
than 250) first switches to simulated speed, see
page 12.
2. , Enter the value for the
simulated speed.

Using the EasySet2
16
EasySet 2 BAG0217.9
06.22
3 Using the EasySet2
3.1 Spreading fertiliser
•
Enter the values for the spread rate in kg/ha and the working
width before operation.
•Determine the fertiliser calibration factor.
Work display at a standstill:
→The spread rate in kg/ha is shown separate-
ly for both shutters.
When the spreading discs are driven,
start driving and simultaneously open the
shutters.
For spreading on one
side, select the corresponding shutter.
The LED shows which shutter is open on one
side.
After pressing the button, you
must start driving within 6 seconds.
"SPEED" display
Then error message E50 appears.
→Press the button again.
The shutters are closed when the
speed is lower than 1.5 km/h.
→When the implement accelerates
within 6 seconds, the shutters
are opened again.
"SPEED" display
→
If the implement accelerates after
more than 6 seconds, the shut-
ters remain closed. Press the
button again if necessary.
Error message E50

Using the EasySet2
EasySet 2
BAG0217.9 06.22
17
Work display while driving:
→The spread rate on both sides and the for-
ward speed are shown.
kg/ha km/h
During operation, the spread rate can be
changed on both sides or on one side by 10%
each time the button is pressed.
Moreover, the originally set spread rate (100%)
can be restored.
(1) Rate on the left
(2) Rate on both sides
(3) Rate on the right
Work display while driving when the spread rate
is changed on one side or both sides:
→The spread rate in kg/ha is shown separate-
ly for both shutters.
If the deviation from the setpoint is
greater than 5%, the work display
alternately shows the current value
and error message E11.
Wedge-shaped field spreading
The multi-stage, one-sided rate change can also
be used as manual part-width section control
when driving into a wedge and when driving out
of a wedge.
This improves the overlap and therefore the ferti-
liser distribution between the area inside the field
and the headland area.

Using the EasySet2
18
EasySet 2 BAG0217.9
06.22
3.2 Performing boundary spreading
Electrically operated limiter
Read the value for adjusting the angle of
the limiter (0-100) from the setting chart.
Depending on the boundary spreading
method, the spread rate must be reduced on the
boundary side.
Read the value for the reduction of the
shutter position from the setting chart.
1. Before boundary spreading / ditch
spreading, reduce the rate on the boundary
side.
2. Activate the limiter for boundary
spreading.
The LED shows the activated limiter.
→
Brief display of the limiter position (1-100)
→
Display ON for 5 seconds after opening the
shutter. Then it switches back to the Work
display.
If the shutters are opened when the limiter
is activated, an signal tone is issued. This also
indicates boundary spreading.

Using the EasySet2
EasySet 2
BAG0217.9 06.22
19
The limiter position can be adjusted.
Lift the limiter higher.
→Smaller effect of the boundary spreading
deflector.
→Greater throw distance.
Displayed value becomes smaller.
Lower the limiter further down.
→Greater effect of the boundary spreading
deflector.
→Smaller throw distance.
Displayed value becomes larger.
After boundary spreading:
1. Deactivate the limiter.
→The LED is turned off.
2. If necessary, set the rate on the
boundary side back to 100%.
Hydraulically operated limiter with position sensor
Depending on the boundary spreading
method, the spread rate must be reduced on the
boundary side.
Read the value for the reduction of the
shutter position from the setting chart.
1. Before boundary spreading / ditch
spreading, reduce the rate on the boundary
side.
2. Actuate the tractor control unit.
→Activate the limiter for boundary spreading.
The LED shows the activated limiter.

Using the EasySet2
20
EasySet 2 BAG0217.9
06.22
Limiter activated
→Display ON for 5 seconds after opening the
shutter.
If the shutters are opened when the limiter
is activated, a signal tone is issued. This also
indicates boundary spreading.
After boundary spreading:
1. Actuate the tractor control unit.
→Deactivate the limiter for boundary
spreading.
The LED is turned off.
2. If necessary, set the rate on the
boundary side back to 100%.
3.3 Spreading slug pellets and fine seeds
•Enter the values for the spread rate in kg/ha and the working
width before operation.
•Determine the calibration factor for slug pellets or fine seeds,
see page 9.
•Set and maintain the simulated speed, see page 12
1. Switch on the implement and the
work display will be shown:
2. Set the simulated speed.
3. When the spreading discs are
driven, start driving and simultaneously
open the shutters.
For spreading on
one side, select the corresponding shutter.
The LED shows which shutter is open on
one side.
Reach the set simulated speed as quickly
as possible.
Maintain the simulated speed while spreading
slug pellets or fine seeds.