Introduction
The EasiFoamer™is designed to be installed using twin distribution tubes of 4mm bore (1/4” outside
diameter) –the BLACK tube supplies compressed air; the BLUE tube supplies pressurised teat
disinfectant chemical –both at a low pressure 3 - 5 psi (0.2 - 0.4 Bar) –see Fig 1. Chemical and air are
supplied to the foaming applicators, which generate foam in the cup whilst the trigger is held depressed.
WARNING –Use only the BLUE tube for the CHEMICAL –the Black tube may be attacked by some
chemicals.
Safety
The EasiFoamer™Foam Teat Dipping System is designed exclusively for use in milking installations.
Any application outside the use described in this operating manual will be taken to be not in accordance
with the intended purpose. The manufacturer/supplier will not be held responsible for any losses arising
as a result of such use. The user will take full responsibility for use. USE IN ACCORDANCE WITH THE
INTENDED PURPOSE ALSO INCLUDES COMPLYING WITH THE OPERATING MANUAL AND THE
CONDITIONS FOR INSPECTION AND MAINTENANCE.
Specifications
Power Source –Liquid –Electric Pumping unit •220-240V AC 50Hz
•115V AC 60Hz
–Fuses • T1.0A
Power Source –Air –Compressed Air • 5 -10L/min at 3 - 7psi (0.2 - 0.5 Bar)
Maximum No. of Applicators per Pumping Unit •10
Maximum No. of Applicators operating simultaneously •2
Maximum Length of Distribution Tubing (Black or Blue) • 45 Metres (150 ft)
Typical Chemical Consumption per Applicator •1.5 –2.5 mL/second
Operating Temperature •5 –40 °C
Installation (refer to Fig. 1, 1B, 1C & 6)
Electrical Installation - should ideally be carried out by a Qualified Electrician –EXCEPT where a
suitable waterproof plug outlet is available. THIS ELECTRICAL SUPPLY SHOULD BE PROTECTED
BY AN APPROPRIATE EARTH LEAKAGE CIRCUIT BREAKER. IT IS RECOMMENDED THAT THE
ELECTRICAL SUPPLY SHOULD BE SWITCHED OFF AUTOMATICALLY WHEN THE VACUUM
PUMP IS NOT IN OPERATION. Please refer to Fig. 6 for connections.
Pressurised Chemical –is sucked up from a chemical container by peristaltic pump(s). The
enclosure housing the pump(s) of the EasiFoamer™is rated at IP44 (IEC 60529), the power unit (A)
must therefore be positioned outside of the milking parlour in a dry location and close to a 220 –240V
AC or 115V AC power socket. The 3-core power supply cord MUST remain accessible when the unit
has been installed and MUST be connected to Earth.
The large enclosure (A1) should be positioned no more than 2 metres vertically above the floor and no
more than 3 metres distant from the chemical container(s). For efficient and reliable operation the
maximum vertical distance from pump to distribution line should be less than 1 metre. Use the
DRILLING TEMPLATE to mark out screw positions and fix the enclosure to a suitable flat wall, using
the screws and plastic plugs supplied.
NOTE: Allow sufficient space to the Right of the enclosure for mounting the Pressure Reservoir Bottle
(W), which MUST be in an UPRIGHT position, using a single screw (see Fig. 1C).
The small enclosure (A2) housing the Pressure Switch (connected to the large enclosure by
10 metres of cable) should be screwed to a flat vertical surface (e.g. Wall) - PREFERABLY IN, or close
to, THE MILKING PARLOUR - but as close as possible to the highest point of the distribution tubing
(see Fig. 1C).
The cable may be temporarily disconnected from the PCB inside the large enclosure (A1). When
reconnecting the cable ensure that all 3 wires are correctly connected. Use Cable clips supplied to
secure cable. continued . . .