Amensolar AW5120 User manual

User Manual of Storage Lithium Battery
AW5120

Amensolar Lithium Battery AW5120 User Manual
Manual Instruction
The Energy Storage Batteries System provides the energy storage for PV users and backup
power support for the important electrical equipment. The battery system can store excessive
power generated by PV system at daytime, and can utilize the stored energy (if necessary) to
supply power for electrical equipment at night, thus improving the utilization efficiency of
photovoltaic power generation, shaving peaks and filling valleys, providing backup power for
emergency and important electrical equipment to avoid data and financial loss caused by sudden
power outage.
The user manual introduces battery details like the basic structure, parameters, procedures
and methods of installation, operation and maintenance.
This manual is only for the 51.2V 100Ah Wall Mounted Lithium Battery, but the inverter
and any other equipment is not included.
This PRODUCT can be installed in parallel mode, more attention should be paid for the DIP
and address selection.
CONTENTS
1. Security Disclaimer ........................................................................................................1
2. Precautions for Safe Use ................................................................................................1
3. Product Introduction ...................................................................................................... 4
4. Specification ...................................................................................................................6
5. Installation .................................................................................................................... 11
6. Abnormal Conditions and Fault Handling ..................................................................15
7. Operation ...................................................................................................................... 16
8. Maintenance and Recycling .........................................................................................17
9.Legal statement ............................................................................................................. 19

Amensolar Lithium Battery AW5120 User Manual
1
1. Security Disclaimer
Users must read this chapter carefully and operate it according to the safety precautions
required by this chapter before installing, using and repairing the battery. Our company will be
responsible for nothing if it happens to any injuries and loses caused by improper
operations.
Attention
It may cause moderate injury or minor injury to human beings, or even damages to product
because of the danger caused by failure to operate as requirements.
Danger
It may cause fire or serious personal injury, or even death because of the danger caused by
failure to operate as requirements.
2. Precautions for Safe Use
We feel quite thankful that you choose AMENSOLAR products. In order to enable you to
use and maintain it in a better way, please kind read this user manual carefully before use.
2.1 Unpacking Examination
Please don’t install the battery if it is found damage or lack of parts. Otherwise, it may be
malfunction.
Please don’t install battery and connect with supplier in time if the packing list doesn’t same
as that of the real one.
2.2 Installation
The battery is suggested installing by skilled worker or electrician. A skilled worker is
defined as a people who had been trained and qualified electrician or had all of the following
skills and experience:
Knowledge of the functional principles and operation of ongrid Energy Storage
systems.
Knowledge of the dangers and risks associated with installing and using electrical
devices and acceptable mitigation methods.
Knowledge of the installation of electrical devices
Knowledge of and adherence to this manual and all safety precautions and best
practices.
Please ensure that the power is cut off before wiring, otherwise, there will be a danger of
electric shock or catching fire.
The installed cables must be meet requirements, and the part of power distribution must
comply with safety regulations.
Please carry out the installation strictly in accordance with the installation steps in the
following chapters, otherwise it will cause the damage to product.

Amensolar Lithium Battery AW5120 User Manual
2
Please lift and put it down gently to avoid hurting feet or damage to product during
transportation and installation.
Please keep battery away from the flammable objects and heat sources.
Please don’t drop any sundries into battery during installation. Otherwise, it may cause
system error.
2.3 Working
Please don’t directly plug or unplug the DC input socket or other sockets like the terminal block
socket, input socket and output socket to avoid the danger of electric shock.
Please don’t directly open the battery shell to avoid the danger of electric shock.
Please ensure that the battery will be work within the allowable range before operating to avoid
damage to product.
Please ensure that the battery is fully charged and the power is cut off if it is not used for a long
time, avoid to the electricity power is empty due to longterm standing.
Please charge the battery regularly and disconnect the switch after the charging is completed if
the product is not used for a long time.
2.4 Maintenance and Overhaul
Please ensure to disconnect the DC input, DC output and switch before disassembling the
shell, to avoid the danger of electric shock.
Please don’t touch directly the exposed parts of circuit to avoid the danger of electric shock,
as there is still residual electricity inside the battery even after the shell is disassembled.
Please ask the professional personnel to perform the maintenance and overhaul.
Please don’t disassemble the battery by yourself. Otherwise, it may cause product damage
and personal injury.
2.5 Transportation
Please avoid strong vibration, falling and bumping during transportation. Don’t place the
package upside down. Don’t lose any accessories and user manual when unpacking package
or transporting battery.
Please be careful of your security and avoid hurting yourself in transportation.
2.6 Others
Please don’t modify the system by yourself to avoid happening serious accidents.
Please immediately cut off the switch and input/output cables if it happens to abnormal
conditions inside the system.
2.7 Response to Emergency Situations
The battery is designed with multiple safety strategies to prevent hazards resulting from
failures. However, we cannot guarantee their absolute safety for uncertain situations.
2.7.1 Leaking batteries

Amensolar Lithium Battery AW5120 User Manual
3
If the battery pack leaks electrolyte, avoid contact with the leaking liquid or gas. Electrolyte
is corrosive and contact may cause skin irritation and chemical burns. If one is exposed to the
leaked substance, do these actions:
Inhalation: Evacuate the contaminated area, and seek medical attention immediately.
Eyes contact: Rinse eyes with flowing water for 15 minutes, and seek medical attention
immediately.
Skin contact: Wash the affected area thoroughly with soap and water, and seek medical
attention immediately.
Ingestion: Induce vomiting as soon as possible, and seek medical attention immediately.
2.7.2 Fire
In case of a fire, make sure that an ABC or carbon dioxide extinguisher is nearby and does
not use water to extinguish the fire.
WARNING
The battery pack may catch fire when heated above 130°C.
If a fire breaks out where the battery is installed, do these actions:
1. Extinguish the fire before the battery catches fire.
2 . If the battery has caught fire, do not try to extinguish the fire. Evacuate people
immediately.
WARNING
If the battery catches fire, it will produce poisonous gases. Do not approach.
2.7.3 Wet battery
If the battery is wet or submerged in water, do not try to access it. Contact your distributor
for technical assistance.
2.7.4 Damaged battery
If the battery damaged, please contact your distributor for help as soon as possible, because
damaged battery is dangerous and must be handled with extreme caution. Damaged battery is not
suit for use and may pose a danger to people or property. If the battery seems to be damaged,
return it to your distributor.
CAUTION
Damaged battery might export electrolyte or flammable gas, so contact for
advice and information immediately.
2.8 Scrap Battery
For scrap battery(ies), please treat with local laws or regulations to recycle or scrap.

Amensolar Lithium Battery AW5120 User Manual
4
3. Product Introduction
AMENSOLAR AW5120 battery is composed of lithium iron phosphate cells in series. The
builtin BMS battery management system can manage and monitor battery information, including
voltage, current and temperature. In addition, the BMS can also balance the charge and discharge
of the battery to extend the cycle life. The battery pack adopts the scientific internal structure
design, advanced battery production technology, with high specific energy and long life, safety
and reliability, wide temperature range and other characteristics, is the ideal green energy storage
power products.
3.1 Support Large-capacity Energy Storage
Multiple batteries can be connected in parallel to enlarge capacity.
3.2 High Reliability System
Adopting highperformance processor and configuring a customized BMS protection board
to guarantee the system can operate stably.
Monitoring battery conditions in realtime. Providing many functions like short circuit
protection, reverse polarity protection, high voltage protection, low voltage protection,
overcurrent protection in charge, overcurrent protection in discharge, overcharge protection,

Amensolar Lithium Battery AW5120 User Manual
5
overdischarge protection, high temperature protection, low temperature protection, balance
cells, etc.
3.3 Strong Communication Function
Configuring multiple communication interfaces: RS485, CAN; Knowing battery working
status at any time through the master computer.
Multiple cascades: Obtaining address automatically; Nonhuman operation.
3.4 Leading Advantages in Product
Supporting charge and discharge by large current, charging and discharging modular design,
Small volume, Light weight, adopting multilevel energy consumption management, Operation
and wiring on front panel, Easy to installation and maintenance; Excellent compatibility;
Seamless connection between BMS and inverter; More convenient operation in one switch;
Suitable for longterm cycles of chargedischarge.
3.5 Product features
Lithium iron phosphate battery, the weight is reduced by 40% compared with the same
specifications of leadacid battery;
Wallhanging structure, the pack can be mounted on the wall with the characteristics of easy
maintenance, flexibility and versatility;
Battery pack shell with insulation coating metal sheet metal;
The power output and input terminal of the battery pack adopts a highpower quickplug
connector, which supports hot swap.
The battery pack can be used in parallel with a maximum of 16 pieces and cannot be used in
series.
Low selfdischarge, no memory effect, shallow charge and shallow discharge performance is
better;

Amensolar Lithium Battery AW5120 User Manual
6
4. Specification
4.1 Battery Specification
ITEM
AW5120
Battery Type
LiFePo4
Mount Type
Rack Mounted
Nominal Voltage (V)
51.2
Capacity (Ah)
100
Nominal Energy (KWh)
5.12
Operating Voltage (V)
44.8~57.6
Max Charge Current (A)
100
Charging Current (A)
50
Max Discharge Current (A)
100
Discharging Current (A)
50
Charging Temperature
0℃~+55℃
Discharging Temperature
20℃~+55℃
Relative Humidity
5% 95%
Dimension (L*W*H mm)
540*704*94mm
Weight (KG)
45±0.5
Communication
CAN, RS485
Enclosure Protection Rating
IP20
Cooling Type
Natural Cooling
Cycles Life
≥6000
Recommend DOD
90%
Design Life
20+ Years (25℃@77℉)
Safety Standard
UL1973/CE/IEC62619/UN38.3
Max Number of Parallel
16

Amensolar Lithium Battery AW5120 User Manual
7
4.2 Product Size
4.3 Product Panel Description

Amensolar Lithium Battery AW5120 User Manual
8
NO.
ITEM
FUNCTION
DESCRIPTION
1
Positive
terminal
Positive output/input
connecting
MAX.DC125A(red) 2 sets can be used in
parallel
2
Negative
terminal
Negative output/input
connecting
MAX. DC125 A(black) 2 sets can be used in
parallel
3
Power
indicator
SOC1: Green, remaining power indicator 1; 0~
16 .6%;
SOC2: green, remaining power indicator 2;
16.6~33.2%;
SOC3: green, remaining power indicator 3;
33.2~49.8%;
SOC4: green, remaining power indicator 4;
49.8~66.4%;
SOC5: green, remaining power indicator 5;
66.4~83.0%;
SOC6: green, remaining power indicator 6;
83.0~100%
ALM: red, alarm protection indicator;Blinking,
steady on protection;
RUN: Green, running indicator.
4
ALM/ RUN
indicator
5
Dip Switch
Address
The dip switch has a total of 4 bits, 1, 2, 3,
4 , each bit represents a value, all pushed to the
digit, digit is 0 , dialed to the ON bit represents 1,
2, 4, 8 in turn, dialed to the ON bit values added,
and then + 1 to get the address bit.
(1+2+4=11+1=12.The 16 th digit is:
1+2+3+4=15+1=16)
For details, please refer to the attachment
6
CAN/RS485
RS485 CAN
RJ45 socket, pin definition and wiring requirements
are as follows:
RS485 interface:
Pin1 & Pin8:485B
Pin2 & Pin7:485A
Pin3 & Pin6: GND
CAN interface:
Pin4: CAN_H [CAN Communication H]
Pin5: CAN_L [CAN Communication L]
Note: Wire specification 24AWG(0.2mm²), wire
length please choose according to the actual
installation situation.
7
RS485/RS485
Parallel communication
The two interfaces can be
connected in
parallel
RJ45 socket, pin definition and wiring requirements
are as follows:
Pin1 & Pin8: 485B
Pin2 & Pin7: 485A
Pin3 & Pin6: GND
Pin5 & Pin4: NC
Note: Wire specification 24AWG(0.2mm²), wire
length please choose according to the actual
installation situation.

Amensolar Lithium Battery AW5120 User Manual
9
8
Reset
Integrated with 3 functions
of turn on, turn off and reset
When BMS is in hibernation state, press the key
(3~6S) and release, and BMS is activated.
When BMS is in the activated state, press the key
(3~6S) and release, and BMS is hibernated.
When BMS is activated, press the key (6~10S) and
release, and BMS is reset.
9
Handle
handle
10
RS232
PC side upper computer
communication
RJ11 socket, pin definition and wiring requirements
are as follows:
Pin3: TX
Pin4: RX
Pin5: GND
Note: Wire specification 24AWG(0.2mm²), wire
length please choose according to the actual
installation situation.
11
Dry contact
optional
12
POWER on/off
Battery start button
Selflocking switch, switch pressed to open, switch
flicked to close.
13
Screen
Battery pack power, battery
voltage and other
information display
4.4 Battery Management System (BMS protection board) Function
4.4.1 BMS Introduction
ARM low power processor;
Professional battery management chip;
Support currentlimiting charging mode (maximum 10A) ;
Support CAN/RS485 communication;
Builtin 4channel temperature acquisition;
Support high and low temperature overcharge and overdischarge protection;
Support battery balancing function;
Support SOC calculation and calibration;
Support twostage overcurrent protection;
Support output shortcircuit protection;
Support polarity reverse connection protection;
Support data storage;
Multiple automatic fault detection (sampling, MOS, battery failure).

Amensolar Lithium Battery AW5120 User Manual
10
4.4.2 Voltage Protection Function
Discharging low-voltage protection
Charging over-voltage protection
In discharging, the overdischarge protection
will start and battery stops to supply
electricity if the voltage of any single cell is
lower than the protection value. The
protection will be dismissed after the voltage
of all cells returns to the range of rated
hysteresis value.
In charging, the system will stop charging if
the voltage of battery module or any single
cell reaches to the protection value. The
protection will be dismissed after the battery
module voltage and cell voltage return to the
range of rated hysteresis value.
4.4.3 Current Protection Function
Charging over-current protection
Discharging over-current protection
System stops charging if charging current is
over the protection value. Protection is
dismissed after a period of time. Please pay
attention that the maximum charging current
shouldn’t exceed to the protection value
when using the battery.
System stops discharging if discharging
current is over the protection value.
Protection is dismissed after a period of time.
Please pay attention that the current required
by electrical equipment shouldn’t exceed to
the protection value when using the battery.
4.4.4 Temperature Protection Function
Charging low/over-temperature protection
Discharging low/over-temperature protection
In charging, system starts charging
temperature protection and stops charging if
the battery temperature is over protection
range, and dismisses protection after
temperature returns to rated hysteresis value.
In discharging, system starts discharging
temperature protection and stops supplying
electricity if the battery temperature is over the
protection range, and dismisses protection after
temperature returns to rated hysteresis value.
4.4.5 Other Protection Function
Short circuit protection
System starts short circuit protection if it occurs to short circuit when battery starts working
from a shutdown state.
4.5 Running Environment
Running Environment
Condition
Working temperature
0℃ 50 ℃
Relative humidity
5% 95%,no condensation
Altitude
2000m
On-site environment
Away from heat source, avoid direct sunlight, no corrosive gas, no
explosive gas, nondestructive insulation gas, nondestructive
insulation conductive dust.
4.6 Storage
Battery storage should comply with the following:
1) When the battery is stored, it should be stored in the charged state of 40%~60%.

Amensolar Lithium Battery AW5120 User Manual
11
2) The battery should be stored in a clean, dry and ventilated room, avoid contact with
corrosive substances, and stay away from fire and heat sources. In the storage process, it is
prohibited to turn the battery upside down, and avoid mechanical impact and weight.
3) When the battery is not used for a long time, it is recommended to supplement the
power every six months or so. It can be charged for 1 to 2 hours by using a DC voltage
regulator charger by 0.2C current.
4) During maintenance, do not load or unload the battery cells in the battery by yourself;
otherwise, the performance of the battery will be degraded.
5) Do not disassemble or change any battery cells in the battery without authorization, and
do not dissect the battery.
5. Installation
5.1 Installation Location
Make sure that the installation location meets the following conditions:
The building is designed to withstand earthquakes, and the floor is flat and level.
Far away from the sea to avoid salt water and humidity.
The installed location should not be access by pet and children.
No flammable or explosive materials nearby, at least 2.5m far away from combustible.
Minimal dust and dirt in the area.
No corrosive gases present, including ammonia and acid vapor.
The battery optimal operate temperature is 15°C to 30°C. Frequent exposure to severe
operating condition would exacerbate the performance and lifetime of the battery.
5.2 Installation Requirements
The installation shall be in a restricted access location/ room or in a cabinet where provides a
barriers for the battery terminal.
The maximum number of battery shall be not over 16 PCS.
5.3 Installation Materials
Following installation materials should be prepared by installers.
Power cable
Data cable
Earth cable
Ground wire
Bipolar external isolator, when two or more battery systems in parallel, each of them shall
have a bipolar isolator. Meanwhile, the isolator shall have ability to break the full load
current.
NOTICE
Make sure that the crosssectional area of charging cables is 25 to 35 mm2.

Amensolar Lithium Battery AW5120 User Manual
12
NOTICE
A breaker between battery and inverter was recommended to install, and the
breaker’s min. current should be over 150A or following with local regulations.
5.4 Tools
To install the battery pack, those following tools are probably required:
Phillips screwdriver Torque wrench Cable crimper Wire clamp
Voltmeter Tape measure Drill Flathead screwdriver
In order to protect operator and installer’s safety, please select and use suitable tools and
measuring instruments that are certified for precision and accuracy.
5.5 Safety Instruments
When dealing with the battery, following safety gears should be equipped. Installers must
meet the relevant requirements of IEC 60364 or the domestic legislation and other relevant
international standards.
Insulated glove Safety goggles Safety shoes
5.6 Technical Preparation
Electrical interface setting
Security examination
Please kind do the following examination if
the battery connects with the user’s device
directly:
Check whether the DC charging interface of
inverter meets requirements of specification,
voltage, current of battery pack.
Check whether power of electrical device
matches with the parameters of battery pack.
Firefighting equipment should be prepared
near the battery, like, the portable dry powder
fire extinguisher. It is strictly forbidden to
place flammable, explosive and other
dangerous items next to the battery.

Amensolar Lithium Battery AW5120 User Manual
13
5.7 Unpacking
Please unload the product as requirements and prevent it from sun and rain when the
device arrives at installing site. Before unpacking, please check the total number of materials
in Packing List attached on package, and check whether is package is well packed or not.
In the process of unpacking, please pay attention to lift and put it down gently and protect
its surface coating.
The installing person should read technical document, check the list, confirm whether
accessories are completed and intact according to Packing List at first after unpacking. If
internal packages are damaged, please check it carefully and take records.
5.8 Preparation
Please ensure the POWER buttons of all batteries are in cutoff status.
Please ensure the charging voltage of the device is within the product allowable range.
Please cut off power to all related devices.
5.9 Installation and wiring
5.9.1 Device installation
Please take reference of the way recommended by manual to place the product. All devices
must be firm during installation. Please arrange the stacked number of devices flexibly as actual
needs. Don’t install batteries on sloping and unstable ground.
5.9.2 Ground wire connection
Please unscrew the screw at the ground hole on front panel, install the ground terminal on
the screw and tighten it with a screwdriver. The other end of ground wire is connected to the
nearby bracket, and the whole is connected to a reliable ground point.
5.9.3 Power cable connection
Please check the continuity of the cable, distinguish the positive and negative terminals,
and label the cables before connecting power cable. Please also check whether there is short
circuit and reverse connection after the cable connection is finished. The checking method is as
follows:
Cable continuity: please adjust to the buzzer gear of multimeter and test two ends of the
cable by a probe. If the buzzer sounds, the cable is available.
Voltage diagnosis: please adjust to the DC voltage gear of multimeter and test the
positive and negative electrode of battery by a probe. If it indicates the voltage within the
normal range, the product can be used.
5.9.4 Cables connection
A single battery: please connect the positive electrode of battery with the DC positive
electrode of inverter by a red cable, and connect the negative electrode of battery with the DC
negative electrode of inverter with a black cable.

Amensolar Lithium Battery AW5120 User Manual
14
Multiple batteries: please adopt the parallel connection method between battery and
battery or battery and inverter. At first, please connect the positive terminals of the adjacent 2
batteries respectively by a red cable, and connect the negative terminals of the adjacent 2
batteries respectively by a black cable. Second, please connect the positive electrode of
battery with the DC positive electrode of inverter by a red cable, and connect the negative
electrode of battery with the DC negative electrode of inverter by a black cable.
5.9.5 Communication wire connection
A single battery: just select the corresponding interface according to the communication
protocol of inverter, or please connect the CAN interface of battery with the communication
interface of inverter. The RS485 interface of battery is used for the communication connection
of two batteries.
Multiple batteries: the host and the slave batteries communicate in cascade mode, one of
them is the host, and the rest are slave batteries. Then, the corresponding port can be connected
to the host battery according to the communication protocol of inverter.
5.9.6 Start-up
Please confirm again whether all cables are correctly connected, firmly connected, and not
short circuit or reverse connection before starting up.
Please turn all battery switch buttons to “ON” .
A single battery: If the battery SOC indicator is always on and the alarm indicator is off, it
means that the battery has been started.
Multiple batteries: If all battery SOC indicators are always on and the alarm indicator is off,
it means that all batteries have been started.
Attention: please connect the inverter immediately to charge if battery power is too low and
cannot be started.
5.9.7 Power-on test
Please connect battery and inverter or DC switching power supply.

Amensolar Lithium Battery AW5120 User Manual
15
Please check whether battery state is normal according to the indicator table:
battery will be in charging mode if battery power is not full and inverter has successfully
charged to battery.
battery will be in standby mode if battery power is full and is not supply power to loads.
battery will be in discharging mode if battery is supply power to loads.
6. Abnormal Conditions and Fault Handling
6.1 Fault and abnormal phenomenon handling
Fault Phenomenon
Fault Causes
Handling Method
DC input fault
No DC input voltage
Please check whether DC input
switch is closed, check whether
circuit is open
Battery fault
No battery DC output
Please check whether switch is
closed, check whether circuit is
open
Overload
Too large power or short
circuit
Please confirm whether load is
less than the rated power, check
whether load is short circuit
STATUS
Normal
Alarm
Protection
ON/
OFF
RUN
ALM
POWER INDICATOR LED
DESCRIPTION
●
●
●
●
●
●
●
●
●
TU RN
OF F
Sle ep
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ALL OFF
ST AND B Y
Normal
ON
FLASH1
OFF
Ac cor d ing to pow e r ind ic ato r
STAN DYBY
Alarm
ON
FLASH1
FLASH3
Low vo ltage
CH ARG E
Normal
ON
ON
OFF
Ac cor d ing to pow e r ind ic ato r
(Maximum power LED of power indicator flash
twice)
Maxi mum power LED flashing (flash
twice ). Wh en overc harg ing al arm, ALM
does not flash
Alarm
ON
ON
FLASH3
Overcharge
protection
ON
ON
OFF
ON
ON
ON
ON
ON
ON
If no grid power, indicator switch to standby
Protection for temperature
overcurrent and failure
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
No Charg ing
DISCHARG E
Normal
ON
FLASH3
OFF
Ac cor d ing to pow e r ind ic ato r
Alarm
ON
FLASH3
FLASH3
Low volta ge prote ctio n
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Stop Di scharging
Temperature, overcurrent, short
circuit,reverse connection,
failure protection
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
Stop Di scharging
FA I LU R E
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
Stop Ch arging/D ischarging

Amensolar Lithium Battery AW5120 User Manual
16
Abnormal temperature
inside system
Over temperature inside
box
Please turn off the load and restart
it after temperature drops, check
whether ambient temperature
exceeds the standards
Low battery
SOC too low
Please charge the battery
System fault
System operation error
Please cut off load, shutdown
switch, and restart battery
The battery is designed with indicators on the upper panel, and has perfect protection
function. Battery system will stop to output power and indicators will indicate the abnormal
condition once the abnormality or failure occurs.
7. Operation
7.1 Charging precautions
1) Charging current
The charging current must not exceed the maximum allowable charging current specified
in this specification. Charging with abnormal current will cause the system protection to start,
which may affect normal use.
2) Charging voltage
The charging voltage shall not exceed the maximum charging voltage specified in this
specification. When the battery voltage is higher than the maximum charging voltage, it will
cause the system protect ion to start, which may affect the normal use.
3) Charging temperature
The battery must be charged in the range of 0°C to 55°C.
4) Reverse charging is prohibited
The battery must be connected according to the installation instructions. Reverse charging
is prohibited and short circuit is prohibited in the positive and negative electrodes of the battery
to avoid the battery pack failure and damage.
7.2 Discharging precautions
1) Discharge current
The load and discharge current of the battery pack should be controlled reasonably.
Excessive use will cause irreversible damage to the battery and affect the normal use.
2) Discharge voltage
Overdischarging of the battery pack will cause adverse internal chemical reactions, so as
to affect the normal use, should try to avoid this situation. After the occurrence of
overdischarge, the battery should be evaluated before continuing to use.
3) Discharge temperature

Amensolar Lithium Battery AW5120 User Manual
17
The product must be discharged in the range of 20℃~55℃, abnormal discharge
temperature may affect the life of the product or make the system protection start, affecting the
normal operation.
7.3 Others
In order to prevent leakage, heating and explosion of the battery, the following operations
should be avoided:
1) Do not put the battery into the fire or heat it;
2) Do not break down or disassemble the battery;
3) It is strictly prohibited to immerse the battery in seawater or water. When not in use, it
should be placed in a cool and dry environment;
4) Do not place the battery near high temperature sources, such as fire, heater, etc.;
5) It is strictly prohibited to connect AC directly, and the DC charger must be used to
charge in accordance with the regulations;
6) It is strictly prohibited to use the battery by reversing the positive and negative
electrodes;
7) Do not use metal to directly short circuit the positive and negative electrodes of the
battery;
8) It is forbidden to store the battery together with metal, and insulation protection
measures should be taken;
9) It is forbidden to use or place the battery at high temperature, otherwise it may cause
overheating, function failure or life reduction of the battery;
10) Do not use the battery in places with strong static electricity and magnetic field,
otherwise it will easily damage the battery safety protection device and bring safety risks.
8. Maintenance and Recycling
Frequent maintenance is required in order to ensure the continuous and normal operation
of battery, and recycling of old equipment is also required in order to settle the environmental
protection issues.
8.1 Operation environment
The installation and storage of battery should avoid the environment of high corrosiveness,
high dust, high temperature and high humidity, especially avoid metal substances falling into
the box.
8.2 Security examination
Please check regularly whether connecting line is aging, and whether connection point of
cable is tight and safe.
8.3 Maintenance requirement

Amensolar Lithium Battery AW5120 User Manual
18
Please cut off power supply completely before opening the box for maintenance. Please
don’t damage parts and components when disassembling, and pay attention to the sequence of
wiring. Please also perform maintenance by wearing insulting gloves and using insulting tools.
8.4 Specific requirements of maintenance
Please clean the dust and debris in box, and check whether the terminals and screws in box
are fastened, whether traces left and damaged components by overheating in the box. Please
refer to user manual to deal with problems when the battery is in fault and cannot work
normally. If the problem still cannot be solved, please contact with the dealer or the
manufacturer as soon as possible. Don’t disassemble parts by yourself.
8.5 Battery Recycling
About the information on proper disposal of old battery, please contact with your local
recycling center or hazardous waste disposal center. Please don’t discard battery into fire as it
may lead to the danger of explosion. Please take reference for your local regulations about
battery disposal requirements and dispose the wasted battery properly. Don’t disassemble
battery randomly as the released electrolyte is harmful to your skins and eyes, and it even has
toxic. Please don’t discard battery into trash. For more detailed information, please contact with
your local recycling/reuse center or hazardous waste disposal center. Don’t discard the wasted
electrical or electronic devices into trash. Please contact your local recycling/reuse center for
proper disposal;
Other manuals for AW5120
1
Table of contents
Other Amensolar Storage manuals