Electric Shock Hazard
High voltage exists within this equipment.
There are no user serviceable parts in this
equipment. All installation and service to
this equipment should be performed by
qualified licensed personnel.
Do not exceed 30 minutes in a steam
bath. Excessive exposure can be harmful
to your health. Excessive exposure can
produce a rapid pulse, light-headedness,
weakness or fainting. If you become
uncomfortable or experience any of the
above conditions exit the steam bath
immediately.
Steam baths can put stress on the body.
Therefore a steam bath should be used
only under a doctor's direction if you:
Are pregnant
Have a heart condition
Have high blood pressure
Have circulatory problems
Are under the influence of alcohol
Are under the influence of drugs
Have diabetes
Are under the care of a physician
Are in generally poor health
Children should use the steam bath only
under close adult supervision.
Scald Hazard: Do Not Touch the steam
head or trim during operation as they are
HOT. Stay at least 12 inches (305 mm)
away from the hot steam escaping from
the steam head.
Be careful when entering a steam bath.
Escaping steam from an overheated
steam room may cause injury.
AMEREC STEAMBATH GENERATORS
(AK and 3K Series Warm Start Option)
TO BE USED WITH KT60, K60 OR K30 CONTROLS
FOR WARM START WITH K200i CONTROL SEE DOCUMENT #4209-51
CAUTION: THIS OPTION KEEPS WATER IN THE STEAM
TANK JUST BELOW THE BOILING POINT FOR AS LONG
AS THE CONTROL IS LEFT "ON". IF YOU ARE PLANNING
NOT TO USE YOUR STEAM GENERATOR OR TO LEAVE
YOUR HOME FOR AN EXTENDED PERIOD OF TIME IT IS
RECOMMENDED THAT THE WARM START CONTROL BE
TURNED OFF.
FOR THE SAFETY OF YOU AND YOUR FAMILY PLEASE
READ THE WARNINGS TO THE RIGHTAND ALL INSTRUC-
TIONS BEFORE USING YOUR STEAMBATH.
POST "STEAMBATH INSTRUCTIONS" LABEL OUTSIDE
STEAMBATH FOR SAFETY WARNINGS.
SAVE THIS MANUAL
Thank you for purchasing your new Amerec steam generator. If we can be of any
assistance do not hesitate to call Steam Technical Support at 1-800-363-0251.
WARNING
4209-36 08-03-12
AK Series Warm Start Option Installation & Owners Manual
WARM START
ON/OFF
4209-36 05/01/14
AK Series Warm Start Option Installation & Owners Manual
page 2
DIAGRAM 4
DIAGRAM 1 DIAGRAM 2
DIAGRAM 3
THIS LOW VOLTAGE CONTROL CAN BE LOCATED
INSIDE OR OUTSIDE THE STEAM ENCLOSURE
WARMSTART
ON/OFF
WARMSTART
ON/OFF
1-3/4" DIAMETER HOLE
IN FINISHED WALL
APPLYSEALANT
(100% SILICONE CAULK)
BUSHING B
HOLE A
18 TO 22 AWG WIRE (SOLID REQUIRED)
RATED 300V 75°C FROM GENERATOR TO
CONTROL. STRIP LENGTH = 1/4" (6mm)
PRESS ON
ORANGE TAB
INSERT WIRE
WARM START
CONTROL
123
LOW VOLTAGE CONTROL WIRE (25' (7,6M)) IS PROVIDED FOR 5 VOLT DC SWITCH CONNECTION
TO THE STEAM GENERATOR. NO ADDITIONAL ELECTRICAL SUPPLY OR WIRING REQUIRED.
1 WHITE
2 RED
3 BLACK
BLACK
RED
WHITE
(A) CIRCUIT BOARD WITH JACK J9 (B) CIRCUIT BOARD (WITHOUT JACK J9)
REAR VIEW
SW LOW HI TANK
JP3
WS
12 3
TB1
JP3
JP3
REAR VIEW
PLACE JUMPER ON LEFT TWO
PINS FOR USE AT ALTITUDES
ABOVE 2500 FEET (760m)
PLACE JUMPER ON RIGHT TWO
PINS FOR USE AT ALTITUDES
BELOW2500 FEET (760m)
PLACE JUMPER ON LEFT TWO
PINS FOR USE AT ALTITUDES
ABOVE 2500 FEET (760m)
PLACE JUMPER ON RIGHT TWO
PINS FOR USE AT ALTITUDES
BELOW2500 FEET (760m)
4209-36 05/01/14
AK Series Warm Start Option Installation & Owners Manual
page 3
SECTION 1: INSTALLATION
SECTION 2: OPERATION
SECTION 3: TEMPERATURE SETTING ADJUSTMENT
1.Assure that both the power circuit and water supply to the generator are on.
2.To activate"Warm Start"press theWarm Startcontrol "ON"andtheLEDshouldlightup.Aslongasthe ledis litthewaterinthesteamgenerator
tank will remain heated to just below the boiling point.
3. To turn the "Warm Start" off press the Warm Start control a second time and the LED on the control should now turn off.
1.Twotemperaturesettingsforthewatertemperatureare available,selectedusingajumper ona3pinheader (seediagram4).Inthelowposition,
the water is heatedtoabout 180°F (82°C), whichshouldprovidepreheat without boiling thewaterin installations up to2500feet(760 m) above
sealevel.Inthehighposition,thewaterisheldat about170°F(77°C)whichshouldperformwell5000feet(1500m).Thesetemperaturesshould
prevent the generator from creating steam while in Warm Start operation.The default factory setting is for low altitude.
2.As shown in diagram 4, there are two steamer control boards available.
(A) If there is a phone type jack next to the header, the jumper is placed on the center and right pins for low altitude operation.
(B) If there is no jack next to the header, the jumper is placed on the center and left pins. If higher altitude settings are required, the installer will
need to change the jumper position as needed.
SECTION 4: SERVICE
IftheLEDontheWarmStartControlorDigitalControlisflashingoran"E"errorcodemessageisdisplayedontheDigitalControl,contactTechnical
Support at 1-800-363-0251 or [email protected]. The symptoms described above indicate a fault condition has occurred.
P.O. Box 2258
Woodinville WA 98072
Phone: 425-951-1120 or 1-800-363-0251
Fax: 425-951-1130
email: support @ amerec .com
1. Control Cable Rough-In: The low voltage control can be mounted up to 75 feet (23 m) from the generator either inside or outside the steam
room. We recommendthe control be located outside thesteam room and in an outof the way location soit won't be confused with a steambath
control. Warm Start is generally turned on then left alone for days or months at a time. Run the 25 feet (7,6 m) control cable (provided) from the
control location through 1/2" (12 mm) holes in the wall studs or ceiling joists to the generator.
Note: 1) Do not staple through or damage wires.
2) Label or color code wires for proper circuit board to Control connection orientation. (See diagram 3)
2. Control Cable at the Generator: To prepare the steam generator
A. Make certain that power is disconnected.
B. Remove cover.
C. Feed wire through hole A and connect to the Warm Start terminal block on the circuit board (See diagram 3). The three wires must be
connected to corresponding terminals on the Warm Start and the steamer circuit board ( 1 to 1, 2 to 2 and 3 to 3).
D. Locate strain relief bushing approximately 9" (230 mm) from stripped end of cable jacket. Snap strain relief bushing into hole A. There
must be no strain on the control cable or its wires.
E. Replace cover.
3. Install Warm Start Control: The low voltage control can be installed using a single switch wiring box with the supplied rough-in adapter plate
or mounted directly to a finished wall
A. Using a 1-3/4" (44 mm) hole saw, drill a hole in the finished wall where the control is to be mounted (the control wires should already
be roughed-in to this location).
B. Locate the control wires, pull them out through the 1-3/4" (44 mm) hole and plug the 3 wires into the connector on the back of the control,
as shown in diagram 3.
C. Run a bead of 100% silicone caulk around the perimeter on the back of the control housing. (See diagram 2). Insert the control into the
wall cavity. Tape the control to the wall while the silicone dries.

Other manuals for AK Series

5

Other Amerec Controllers manuals

Amerec Elite User manual

Amerec

Amerec Elite User manual

Amerec K3 User manual

Amerec

Amerec K3 User manual

Amerec K4 User manual

Amerec

Amerec K4 User manual

Amerec K60 User manual

Amerec

Amerec K60 User manual

Popular Controllers manuals by other brands

Carel ir33+wide quick start guide

Carel

Carel ir33+wide quick start guide

Intel 848P Thermal Design Guide

Intel

Intel 848P Thermal Design Guide

Omron NX-SID Series user manual

Omron

Omron NX-SID Series user manual

Topcon OPUS A3 Eco Get started

Topcon

Topcon OPUS A3 Eco Get started

EuroLite Pro-Controller user manual

EuroLite

EuroLite Pro-Controller user manual

Hanna Instruments HI 7871 instruction manual

Hanna Instruments

Hanna Instruments HI 7871 instruction manual

Emerson Fisher Accu-Pressure Y693 instruction manual

Emerson

Emerson Fisher Accu-Pressure Y693 instruction manual

Universal MSC-400 Reference manual

Universal

Universal MSC-400 Reference manual

TP-Link TL-PA4022P KIT user guide

TP-Link

TP-Link TL-PA4022P KIT user guide

Sinclair SWC-04 user manual

Sinclair

Sinclair SWC-04 user manual

NAiS FP Series Hardware manual

NAiS

NAiS FP Series Hardware manual

WEG SSW-08 user manual

WEG

WEG SSW-08 user manual

Martin DMX 8 Zone product manual

Martin

Martin DMX 8 Zone product manual

EMRI 3TX20 instruction manual

EMRI

EMRI 3TX20 instruction manual

PowerTech MP3764 user manual

PowerTech

PowerTech MP3764 user manual

Nordberg A2020 instruction manual

Nordberg

Nordberg A2020 instruction manual

NXP Semiconductors MPC5644A Reference manual

NXP Semiconductors

NXP Semiconductors MPC5644A Reference manual

Atlas Systems ECHC-08-04 Operation manual

Atlas Systems

Atlas Systems ECHC-08-04 Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.