INST-EAI Rev 2
Conrm EverAlert Integrator Installation
a. Click on Displays in the menu bar below the DISPLAY LIST.
b. The list of Integrator(s) assigned to the site will display under Integrator menu bar. A green
status icon next to the Integrator title indicates the Integrator is communicating with the inCloud
Management Portal. A red status indicates a lack of communication between the Integrator and the
inCloud Management Portal. This means the Integrator may not be installed correctly or there is a
network ssue. Reference the Installation Manual for troubleshooting.
c. The icons under INPUT 1 and INPUT 2 should be green unless an Alarm is triggered. The icon for
the triggered input will be red until the Alarm is cleared.
EverAlert Integrator Status Indication
The status LED on the Integrator indicates the
connection status and veries the activation status of the
INPUT switches.
• RED: Power on, no connection
• ORANGE: IP received
• GREEN: Integrator connected to Portal
• FLASHING GREEN (1 sec interval): INPUT 1 ON
• FLASHING GREEN (3 sec interval): INPUT 2 ON
• FLASHING GREEN (5 sec interval): INPUT 1 ON
and INPUT 2 ON
Pre-Installation
1. Determine a mounting location that is near intended monitoring equipment.
2. An Ethernet connection with internet access is required to communicate with the EverAlert
Management Portal.
• Ethernet 10/100 Base-T
• DHCP enabled network is required
3. CAUTION: If the Integrator will be connected to Life Safety equipment such as a re alarm panel, it is
recommended that these connections be made by the licensed installer of the system.
Unpack the box
Remove the components from the box. Save the packing materials in case you need them later.
Check the contents
Your package contains:
• Quick Start Guide
• EverAlert Integrator
• Power Supply AC-9VDC Wall Plug
• 4 ea. Rubber Feet
9
10
EverAlert®Integrator Start Installation Guide
Please read this rst!
If this is your rst installation or you have questions at any time during this process, please call
American Time toll free at 800-328-8996.
phone: 800-328-8996 online: american-time.com fax: 800-789-1882
mail: 140 3rd St. So.; PO Box 707, Dassel, MN 55325-0707
1
2
3
Integrator Output Function
The Integrator Output can activate secondary low-powered devices, such as a
strobe or alarm (or a larger secondary relay for devices requiring more power),
when one of the Inputs or a specied Alarm/Weather Alert is activated. The Output
relay is capable of supporting voltage up to 60VDC or 125VAC, with a maximum
switched current and carrying current of 1A. DO NOT EXCEED THIS VOLTAGE
AND CURRENT. If greater voltage/current is required for the connected device, the
Output relay can be used to command a larger relay.
The wiring shown in Step 5 will keep the secondary device inactive until the
associated Input is activated. Switching the wiring from the Normally Closed
(1) contact to the Normally Open (3) contact will reverse the Output function,
meaning the secondary device will be active until the associated Input and/or
Alarm is activated.
11
1. Normally Closed
2. Common
3. Normally Open
INTEGRATOR QUICK START INSTALLATION GUIDE
Mounting
1. Wall Mount
a. Position EverAlert Integrator in the desired location.
b. Use at least one screw on each ange of EverAlert Integrator to
attach to wall.
2. Desktop, Shelf or Table Top
a. Place EverAlert Integrator upside down on a smooth, at
surface.
b. Peel off the rubber feet from the adhesive strip and place them
down onto each corner of the EverAlert Integrator.
c. Turn over the EverAlert Integrator so that it is resting on the
rubber feet.
Installation
1. Connect the supplied external power supply to the barrel jack
power connector and plug into AC wall receptacle.
2. Connect Ethernet cable to EverAlert Integrator and to a network
switch or router.
Alarm Denitions
EverAlert sites come with a number of precongured alarms. To add
a new alarm, follow the steps below.
a. Login to incloud.american-time.com.
b. Click on the Site where the EverAlert Integrator will be installed.
c. Select "Alarm Denitions" from the Admin drop down menu.
d. Click on "Alarms," then click "Add New" at the top of the page.
e. TITLE: Enter the Alarm Title (i.e. Fire, Tornado or Lockdown).
f. INSTRUCTIONS: Enter the information that will display on the
screen when the Alarm is triggered. This is most commonly
the instructions that provide direction to the recipients of the
message.
g. PRIORITY: Select the Alarm priority. The priority sets the
override sequence with 1 being the highest to 10 being the
lowest. The higher priority Alarm will override the lower priority
Alarm if both occur at the same time.
h. AUDIO: Select an audio le for the Alarm.
i. PANEL COLOR: Select the panel color for the display
background when the Alarm is triggered.
j. MOBILE BUTTON COLOR: This is the color of the button that
issues the Alarm from the mobile device.
k. MOBILE ENABLED: Enables or disables the ability to send the
Alarm from a mobile device.
l. ENABLED: Enables or disables the Alarm. If disabled, the Alarm
will not display as an option for the integrator.
m.Click on the green Save button to save the Alarm.
n. Repeat steps d – m for additional Alarms Denitions.
Congure the EverAlert Integrator on
inCloud
a. Click on "Alarm Integrators" from the Admin drop down menu.
b. Click "Add New" at the top of the page.
c. MAC: Enter the serial number from the bottom of the Integrator.
Carefully verify the serial number entered into the eld matches
the number on the device as this eld cannot be edited once
saved.
d. NAME: Enter the desired name of the integrator.
e. INPUT 1 ALARM: Select the desired Alarm from the drop down
list.
f. INPUT 2 ALARM: Select the desired Alarm from the drop down
list.
g. DESCRIPTION/NOTES: A brief description about the device
such as the location of the Integrator can be entered here.
h. Click the green Save button.
i. If the displays have been already installed and provisioned, the
screen will populate a list of all the displays for that site and all
the displays will automatically be assigned to the Integrator.
For each additional Integrator added, the displays will be
automatically assigned to the Integrator. If adding more than one
Integrator to the site, the displays will need to be assigned as
desired after the last Integrator has been added. Reference the
Installation Manual for assigning displays.
j. Repeat steps a – h for additional Integrator devices.
If using the Output function, the desired parameters for the Output
to be activated can be set on the Edit Integrator page, which can be
reached by clicking on the Integrator name while in the Device List.
The Output can be set to be triggered by All Alarms (meaning both
Inputs and all Weather Alerts), by following either one or both of the
Inputs (meaning the Output will be triggered any time the specied
Input is active), or by specic Weather Alerts. Note that only Alert-
level Weather Alarms will be available.
Wiring
The EverAlert Integrator (INPUT 1 or INPUT 2) can be connected to
any normally open contact closure type switch. The Integrator can
also be connected using the Output function as shown below to
activate a secondary device (such a strobe or siren) when an alarm
becomes active. See section 11 for details on the Output function.
All EverAlert Displays congured on the same Site as the EverAlert
Integrator will have their full screen alarms triggered when the Input
contact closure switch is closed. They will remain active until the
switch is opened again. See wiring diagram below for inactive state.
TITLE (See 7 e.)
PANEL COLOR (See 7 i.)
INSTRUCTIONS (See 7 F.)
Sample
4
5
6
7
8
Input1 Input2
NC NO
AUX RELAY
9V Power Supply
Alarm Panel Example
Switch Example
EverAlert Integrator
+9Vdc
Ethernet
Network In
Output
NO = Normally Open
C = Common
NC = Normally Closed
C
NC
NO
+ from device
power source
+ to device
function
EverAler t®
emergency communication platform

Popular Modem manuals by other brands

Huawei SmartAX MT880a user guide

Huawei

Huawei SmartAX MT880a user guide

Huawei E181 HSPA quick start guide

Huawei

Huawei E181 HSPA quick start guide

Skypatrol ST8050 user guide

Skypatrol

Skypatrol ST8050 user guide

PLNetworks PLS100WF user guide

PLNetworks

PLNetworks PLS100WF user guide

Belt-Way Scales PCMVZW quick start guide

Belt-Way Scales

Belt-Way Scales PCMVZW quick start guide

Spectranet WiMAX USB Stick quick start guide

Spectranet

Spectranet WiMAX USB Stick quick start guide

Huawei E8231 Product description

Huawei

Huawei E8231 Product description

Atlantis Land I-STORM USB A01-AU1 user manual

Atlantis Land

Atlantis Land I-STORM USB A01-AU1 user manual

LevelOne ADSL2 FBR-1461 Quick installation guide

LevelOne

LevelOne ADSL2 FBR-1461 Quick installation guide

AirLink Communications Raven II user manual

AirLink Communications

AirLink Communications Raven II user manual

ZyXEL Communications OMNI 56K USB MODEM quick start guide

ZyXEL Communications

ZyXEL Communications OMNI 56K USB MODEM quick start guide

Zamel supla ROW-02 quick start guide

Zamel

Zamel supla ROW-02 quick start guide

Pentagram horNET Wi-Fi PCI Installation and operation manual

Pentagram

Pentagram horNET Wi-Fi PCI Installation and operation manual

Huawei EchoLife BM325 quick start guide

Huawei

Huawei EchoLife BM325 quick start guide

Hitron 4589 Setup manual

Hitron

Hitron 4589 Setup manual

Netopia 3342 Specification sheet

Netopia

Netopia 3342 Specification sheet

Huawei EC1260 manual

Huawei

Huawei EC1260 manual

Motorola SURFboard SBV5222 Guía del usuario

Motorola

Motorola SURFboard SBV5222 Guía del usuario

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.