Ampac 4310-0087 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

MAN3035-1
Zone Disable and Indicator Module Item Number: 4310-0087
Installation guide
1
Description
Monitors and Disables Zones
Eight push on / push off switches per card
Two Zone status indicators per switch (Alarm & Fault /
Isolate)
The Zone Disable and Indicator Card Kit consists of;
•1 x Zone Disable Module
•1 x 220mm RJ45 Comms cable.
•1 x 350mm RJ45 Comms cable
Installation
Observe anti-static precautions at all times
1. Unclip the PCB Assembly from the plastic housing
2. Slide in Zone Labels. Use LAB3100 label template.
3. Mount the plastic housing in the next free ancillary
cutout in the Fire Alarm Control Panel.
4. Clip the PCB assembly back into the plastic
housing
Figure 1: Zone Disable and Indicator Card (See
LAB3100.doc for Slip In Label)
Termination Link
In Out
Address
Switch
Set to 1
1 2 3 4
ON
C
N
1
C
N
2
CN1: Communications & 27V IN
from CN2 off the previous Front
Panel Card or CN9 on the Main Card
CN2: Communications & 27V OUT to Next Front Panel Card.
If Unsed the Termination Link Must be Inserted.
Top Card &
PCB Securing Clips
Bottom Card &
PCB Securing Clips
Figure 2: Zone Disable and Indicator Card PCB Layout
Connecting to the FACP
1. Power down the FACP
2. Set the required Address using the 4 way dip
switch (Figure 2)
3. If fitted as the last module the EOL link needs to be
fitted (Figure 2)
4. Using the supplied RJ45 cable connect the module
to the applicable Fire Alarm Control Panel (FACP)
(see Figure 3 & 4)
5. Power up the FACP
6. Using the applicable Configuration tool
ConfigManager (FireFinder/Plus) or LoopMaster
(LoopSense) configure the Zone Disable and
Indicator Module as follows:
LoopMaster
Add the module in the panel add-ons section
Then configure the applicable zones (Defaults Zones 1–
8)
Configmanager
On the Controller Configuration panel select the Zone
Cont
Then configure the applicable zones on the Zone
Controller viewing pane
NOTE: A Maximum of 15 Cards can be fitted to the
LoopSense Plus and FireFinder Plus panel range
MAN3035-1
Zone Disable and Indicator Module Item Number: 4310-0087
Installation guide
2
OUT
BUZZER
INHIBIT
BUZZER
RS485 EOL
+5V
0V
PRINTER 27V
TERMINATION BOARD
1
NODE ADDRESS NETWORK LOOP
COMMS
PSU MONITOR
PRINTER
RESET
27V IN
COMMS1
RS232/MODEM
(BOTTOM) EXPANSION PANEL EXPANSION LEDS FRONT PANEL
BRIGADE I/F
23
4
BACKLIGHT
EXPANSION
EXTRA CONTROLS
KEY SWITCH
EXPANSION
SLAVE 2
SLAVE 3
SLAVE 4
MODULE
MODULE
COMMS2 RS232 (TOP)
RS232
COMMS 2
CN26
CN8
CN27
CN11
CN23
CN17
CN13 CN15
CN10
CN4
87654321
SW2
CN18
CN14
CN9
CN16
CN7
CN2 CN5
+
BZ1
SW1
CN3 CN1
LK3
CN20
LK2
CN6
CN100
DEBUG
CN2
LK1
TP1
DEBUG
CN2
LK1
TP1
DEBUG
CN2
LK1
TP1
MAIN BOARD
MAIN CPU
SLAVE CPU 4 SLAVE CPU 3 SLAVE CPU 2
CN21
USB
CN25
Fit EOL Termination Link
if Last Module
on Comms Bus
In Out
Address Switch
Set to Appropriate
Address
(Add 1 Shown)
1 2 3 4
ON
C
N
1
C
N
2
RS485 Control
/ 27VDC
Comms In
RS485 Control
/ 27VDC
Comms Out
C
N
21
Fit EOL Termination Link
if Last Module
on Comms Bus
In Out
Address Switch
Set to Appropriate
Address
(Add 1 Shown)
1 2 3 4
ON
C
N
1
C
N
2
RS485 Control
/ 27VDC
Comms In
RS485 Control
/ 27VDC
Comms Out
CAB1905
CAB1905
Figure 3: General Wiring Zone Disable and Indicator Card (FireFinder / Plus)
USB
N1236
MON. OU T1
0V
AUX OUT1
3
2
1
OUT2
OUT1
+VE
EARTH MON.
COMMS
SGD
BRD82MBA6-
+VE +VEA+
0V+27V
INPUTS SUPERVISED O/PS
LOOP 1 LOOP 2
B-RS485+ RS485- SHD 2+ 3+ 4+COM 1+ 2+ AUX OUT2
2- 3- 4-3+1+ 4+1-
ETH
+27V 0V
PWR OUT
PSU CONTROL
DIAGNOSTICS
RS485
TERM
LOAD
RESET
HLI PORT
FRONT
CONTROLS
PWR IN
N/O CN/C N/O CN/C N/O CN/C
RELAY 1 RELAY 2 RELAY 3
COMMS A- B+ B+A- B-A+
DONGLE
31/07/2009
1
2
3
DIAGNOSTICS
RS232
40V
12V5V
3V3
0V
0V
CN11
TB1 TB6
K1
CN6
CN1
CN7
CN4
CN5
CN10
CN2
CN8
TB4TB2 TB5TB3
SW1
CN9
K3
U24
CN3
MON. OU T4MON. OU T3MON. OU T2
D12
D11D10
D9
TB1 TB2 TB3 TB4 TB5
CN2
CN4
CN11
CN6 CN7 CN8 CN9
CN5
TB6
Fit EOL Termination Link
if Last Module
on Comms Bus
In Out
Address Switch
Set to Appropriate
Address
(Add 1 Shown)
1 2 3 4
ON
C
N
1
C
N
2
RS485 Control
/ 27VDC
Comms In
RS485 Control
/ 27VDC
Comms Out
Fit EOL Termination Link
if Last Module
on Comms Bus
In Out
Address Switch
Set to Appropriate
Address
(Add 1 Shown)
1 2 3 4
ON
C
N
1
C
N
2
RS485 Control
/ 27VDC
Comms In
RS485 Control
/ 27VDC
Comms Out
CAB1905
C
N
10
CAB1905
Figure 4 General Wiring Zone Disable and Indicator Card (LoopSense)