Summary of Features
amperes
amperes electronics
PAGE 2
Thank you for choosing another quality product from Amperes Electronics.
EP1200 is used for emergency paging, required as a highest priority source of announcement when the
situation warrants. Whenever it is activated, it shall override the incoming signal from mixer, thus allows only
emergency announcement to be made, either from the paging microphone or auto announcement voice
player or siren.
Extra feature available from EP1200 is the availability of a dry contact, which is activated whenever the unit
is triggered. This allows connected to volume controller for overriding purpose.
We believe that this product shall be able to meet your demanding requirement with affordable pricing and
uncompromised features and quality. Though it is rather simple in the installation works, a brief read through
the manual is recommended and we are confident that you are getting a product of excellence.
1. Built In Siren Tone Generator
The built in siren tone generator can be activated via the front panel test switch as well as remote triggering
switch. Its continuous 8 KHz tone shall be active for approximately 10 seconds when the switched is
pressed and shall cut off thereafter.
2. Visual FIRE Indicator
The front FIRE indicator shall lit when the siren is activated, or when the emergency paging microphone is
switched on. The bright flashing alert shall also lit when the remote siren port is triggered.
3. External Voice Message Activation
External voice recorder can be connected to EP1200, instead to preamplifier mixer to allow prioritized
message broadcast over the BGM or normal paging sources. The activation of this playback shall require a
voltage free triggering which is available at the rear of the unit.
4. Priority Front Panel Microphone Paging
The front panel microphone is accorded the highest priority in paging, thus bypassing any available input
sources. This is important that emergency broadcast is not interfered when this announcement is made.
5. Aux Dry Contact for ALL CALL / E/M 24V Overriding Signal
When paging microphone or the siren is activated, it shall trigger an internal relay which provide a dry
contact. This can be used to switch on ALL CALL feature of the speaker zone selector as well as sending a
24V emergency overriding signal to bypass volume controllers' attenuation. Proper configuration is required
to utilize this feature.

TEST MIC
amperes
1200
EP
SIREN ACTIVATE
POWER FIRE
EP1200
MIN MAX MAXMIN
Another Quality Product From
S/N :
INPUT LEVEL
SIRENMESSAGE
MESSAGE SIREN
MESSAGE IN PRE IN PRE OUT
REMOTE TRIGGER
FRONT VIEW
REAR VIEW
12
3
4
5
678910 11 12 13 14
1. TEST / SIREN SWITCH
Press the front switch shall activate the siren which is momentary. FIRE indicator shall lit and the MIC switch
relay (item 7) shall close. Release of the switch shall deactivate the siren, Pressing it continuously shall activate
the unit for about 10 seconds, after which the unit shall reset.
PAGE 3
amperes electronics
Parts Identifications
2. POWER / STANDBY LED
This LED indicates the presence of operating 24V supply and the unit is in Standby mode.
3. SIREN LED
Activation of Siren shall lit the LED.
4. FIRE INDICATOR
Whenever siren or external activation device is triggered, the FIRE indicator shall flash alongside with siren
audio broadcast.
5. HANDHELD PAGING MICROPHONE
Pressing the microphone switch shall have priority over other inputs such as Siren, External Message input as
well as normal paging or BGM feeds. This shall also activate a dry contact, which can be used to activate ALL
CALL at speaker zone selector and 24V DC E/M overriding signal.

Parts Identifications
amperes electronics
PAGE 4
www.ampereselectronics.com
6. 24V INPUT
The unit operates on 24V DC. It is preferred that the unit to be supplied directly from the uninterrupted
power source. ie. Back up batteries. Alternatively, connect it to a regulated power supply unit which is
in turned has back up supply.
7. MIC SWITCH TRIGGER CONTACT
Triggering the front panel mic switch shall activate an internal relay. This ports provide a dry contact
which can be used to connect E/M overriding signal or to activate ALL CALL at speaker zone selector.
The recommended rating for the contact is 3A. In case higher rating is required, please use external
relay or contactoer to accomodate the high current requirement.
8. REMOTE TRIGGER PORT FOR SIREN
External sensor device such as heat detector or fire alarm interface device can be connected to this
unit to activate the siren. The external device or switch must be voltage free to avoid damage to the
unit. Siren activation shall be approximately 10 seconds, afterwhich another contact is required to
broadcast the siren.
9. EXTERNAL MESSAGE TRIGGER PORT
External message player can be linked to it and can be broadcasted to the speakers when this port is
triggered. A voltage free contact is recommended to trigger the message playback.
10. MESSAGE INPUT LEVEL CONTROL
This is to adjust the incoming level of the message playback signal. It is recommended that the setting
is made during testing and commissioning works.
11. SIREN OUTPUT LEVEL
Adjust the siren output to an optimum level during testing and commissiong works.
12. EXTERNAL MESSAGE AUDIO INPUT
The external message playback signal shall be balanced line level.
13. PRE-AMPLIFIER INPUT JACK
Output from pre-amplifier mixer (balanced line level ) is connected to the unit which is normally closed
when the unit is not activated. Triggering the panel shall bypass the signal to allow higher priority
audio to the PA system.
14. AUDIO OUTPUT JACK
Connect the balanced output signal from EP1200 to power amplifier signal input.

www.ampereselectronics.com
PAGE 5
amperes electronics
Schematic Diagram
TEST MIC
amperes
1200
EP
SIREN ACTIVATE
POWER FIRE
amperes
POWER
OFF SELECT
TUNER
CD
CASS
OFF
MASTER
MUSIC SOURCE
SIG IN
BASS MAXMIN
EXT INPUT
MAX MAXMIN
SOURCE
MIN
SIG IN
CHIME MIXER TREBLE
MAXMIN
TONE CTRL
CH5 CH6CH4
SIG INSIGIN SIG IN
MAXMIN MAXMIN MIN
CH3CH1 CH2
SIG INSIG IN
MAXMIN MAXMIN MAXMIN MAX
AUX
2122
MX
SIG IN
amperes 120 Watts
PA 2120
CLIP
PROTECT
POWER
SIGNAL -10 dB
SIGNAL -40 dB
POWER
amperes
ALL
CALL
11 12109876
SPEAKER ZONE SELECT
4 531 2
OVERRIDE
ZS 5121
INPUT SOURCES (PAGING MICS, BGM PLAYERS ETC)
24V DC SUPPLY
24V DC BACK UP
24V DC SUPPLY
24V DC SUPPLY
MX2122 PRE-AMP
MIXER
EP1200 EMERGENCY
PANEL
POWER AMPLIFIERS
ZS SPEAKER
ZONE SELECTOR
SPK VOLUME
CONTROLLERS
SPEAKERS
audio out - balanced
audio out - balanced
100V line audio output
100V line output
24V E/M
override
24V E/M
override
100V line output
dry contact to
activate ALL
CALL and 24V
E/M override
signal

Connecting The Unit
amperes electronics
PAGE 6
EP1200
MIN MAX MAXMIN
Another Quality Product From
S/N :
INPUT LEVEL
SIRENMESSAGE
MESSAGE SIREN
MESSAGE IN PRE IN PRE OUT
REMOTE TRIGGER
24V DC POWER
SUPPLY / BACK
UP SUPPLY
TRIGGERING PORT TO
ACTIVATE EXTERNAL
PLAYBACK DEVICE
EXTERNAL AUDIO INPUT
(BALANCED LINE SIGNAL) FROM
MESSAGE PLAYBACK DEVICE
OUTPUT FROM PRE-
AMPLIFIER MIXER
(BALANCED LINE LEVEL)
TO POWER
AMPLIFIER INPUT
(BALANCED LINE)
EXTERNAL SIREN
ACTIVATION CONTACT
(VOLTAGE FREE) ie.
FIRE CONTROL CENTER
/ SMOKE DETECTORS,
ETC
DRY CONTACT
(NORMALLY OPEN)
CONNECT TO ZONE
SELECTORS FOR E/M
OVERRIDING SIGNAL
ACTIVATION

PAGE 7
Technical Specifications
Power source
Consumption
Microphone
Sensitivity
Impedance
Frequency Response
Siren
Siren duration
Siren frequency
Activation
Inputs
Output level
Priority sequence
Dimensions
Weight
24V DC : 0.3 A
3.5W
-72 dB Omni directional
600 Ohm
300 ~ 8 kHz
10 seconds
8 kHz continuous
Front test switch,
remote contact
Message, pre-amp input
Balanced line out, 1.25V
Paging mic - siren - message - preamplifier output
482 (W) x 88 (H) x 80 (D) mm
2.5 kgs
Configuring ALL CALL and E/M Overriding
EP1200
SIRENMESSAGE
REMOTE TRIGGER
CONT
RELAYDC 24V
ZS 5121
+RELAY
TRIG 5
REMOTE SELECT
4321 A6
EP1200
PS9400 PSU
PM Series
Paging MIc
ZS5121 Zone Selector
Volume Controller
To Speakers
Fr. Zone Selector 100V
Line Output
24V E/M
Overriding
Signal
Connect this to allow
EP1200 to trigger
internal relay of Zone
Selector

Only Amperes Electronics Service Centres are allowed to make warranty repairs : a list of Amperes
Electronics Service Centres may be asked for by the purchaser or send directly to Amperes Electronics Sdn
Bhd at 70 Jalan Industri PBP 3, Tmn Perindustrian Pusat Bandar Puchong, 47100, Puchong, Selangor,
Malaysia or its authorized master distributor, Amperes Global Marketing. This warranty is not valid if repairs
are performed by unauthorized personnel or service centres.
This warranty covers only repairs and replacement of defective parts ; cost and risks of transportation as
well as removal and installation of the product from the main system are for the account of the purchaser.
This warranty shall not extend to the replacement of the unit.
This warranty does not cover damages caused by misuse, neglect, accident of the product as well as using
the product with power supply voltage other than shown on the product, or any other power supply source /
adaptor not recommended by the manufacturer.
This warranty does not cover damages caused by fire, earthquakes, floods. lightning and every cause not
directly related to the unit.
This warranty does not include any indemnity in favor of the purchaser or the dealer for the period out of
use of the unit; moreover the warranty does not cover any damages which may be caused to people and
things when using the product.
This warranty certificate is valid only for the described product, and is not valid if modifications are made on
this certificate or on the identification label applied on the product.
This warranty covers all the material and manufacturing defects and is valid for a period of 12 months from
the date of purchase or for a longer period in countries where this is stated by a national law. In this case,
the extension is valid only in the country where the product is purchased.
Amperes Electronics Sdn Bhd is not obliged to modify previously manufactured products under warranty if
the design changes or improvements are made.
WARRANTY CONDITIONS
Information contained in this manual is subject to change without prior notice and does not represent a
commitment on the part of the vendor. AMPERES ELECTRONICS SDN BHD shall not be liable for any
loss or damages whatsoever arising from the use of information or any error contained in this manual.
It is recommended that all services and repairs on this product be carried out by AMPERES
ELECTRONICS SDN BHD or its authorized service agents.
AMPERES series must only be used for the purpose they were intended by the manufacturer and in
conjunction with this operating manual.
AMPERES ELECTRONICS SDN BHD cannot accept any liability whatsoever for any loss or damages
caused by service, maintenance or repair by unauthorized personnel, or by use other than that intended by
the manufacturer.
amperes
DISCLAIMER
By :
AMPERES ELECTRONICS
www.ampereselectronics.com
Made In Malaysia
PAGE 8
Table of contents
Popular Security System manuals by other brands

2gig Technologies
2gig Technologies Go Control install guide

Epicalert
Epicalert Apex EPIC-AP130 Installer manual

Honeywell Home
Honeywell Home PROA7PLUS Series Installation and setup guide

Parker
Parker 88-021610-01G user guide

Cobalt Digital Inc
Cobalt Digital Inc +EAS Manual supplement

ritm
ritm Contact GSM-9N quick start guide