Amperes iPX5400 User manual

INSTRUCTION MANUAL
iPX5400
Ethernet Transceiver
Thank you for choosing another quality product from Amperes Electronics.
Introducing another product for the convenience of installation when it is required to send audio / data from a distance
away. iPX5400 is a transceiver unit, which is able to operate in duplex mode ( paging ), works in pair in LAN environment
or connected directly via UTP cable or Fiber through a converter. It is a simple device allowing peer to peer communication
without the need to employ full IP solutions in your system.
Among applications includes :
- Sending audio from Guard House's paging mic to main system at a distance away through fiber link thus reducing the
risks of lightning surge
- Rack to rack audio / data transmission through existing LAN, thus avoiding the need to lay new cables
- Apply it with wireless AP for areas where laying of new cables are not feasible.
R
Get more information and
latest updates
VER 2 / 2022

Parts Identification
2
PAGE 2 iPX5400 | ETHERNET TRANSCEIVER
3
6
7
1
1. INDICATOR LEDS
Front View Rear View
9 105
4
8
R
LEDs for Power : Blue ( DC power connected), Server (when network connection established) , Status (when transmitter
and receiver communicates ) and Streaming ( When transmitter is sending data / audio ).
2. POWER PORT
24V DC power supply input.
3. ETHERNET PORT
Ethernet Port for connection to network switch.
4. RESET BUTTON
Press to enable iPX5400 to enter bootloader mode or reset the unit to factory settings.
Bootloader mode : Press and hold until Power, Server and Status LEDs lit. This mode enables firmware updating if
normal updating not possible. All data saved previously will remain.
Reset mode : Press and hold until Power, Server, Status and Streaming to reset the unit. All data will be lost.
5. RELAY CONTACT
Activating transmitter remote trigger will activate receiver Relay Contact with NO. Can be used as E/M relay contact to
override signal or to trigger All Call
6. REMOTE TRIGGER PORT
This contact from transmitter when closed shall trigger Relay Contact at receiver
7. RS485 PORT
For RS485 data transmission from PD paging mic to activate zone decoder / selector connected with receiver.
8. SIGNAL INDICATOR
Signal indicator for audio signal which will blink according to the audio level.
9. AUDIO INPUT PORT
Connect audio input with balanced line level from paging mic or other BGM source.
10. AUDIO OUTPUT PORT
Output received shall be balanced line level, to connect to external mixer, amplifier, etc.

iPX5400 | ETHERNET TRANSCEIVER PAGE 3
Connecting to iPX5400
2. Connecting PM1000 mic to iPX5400 with dry contact activation
Normal mic such as PM1000 can use to transmit with a dry contact as activation key. At the receiving end, there shall be audio
output for link to mixer, etc and another dry contact for other general purpose. An example is to use a handheld mic as emer-
gency mic at guard house to trigger an ALL CALL at system rack for emergency announcement.
Application Example : Peer to Peer Direct Connectivity
PD Series Mic
Main PA Rack
Cat5e / Cat 6 ( crossed ) or
Fiber optic cable via LAN - FO converter
or through existing
LAN
Music Player
24V DC Power
Speakers
iPX5400
24V OR Contact if applicable
D
AMPLIFIERMONITOR
AMPLIFIEROUTPUTLE VELMETER(dB )
AMPLIFIEROUTPUTS IG NAL
8 9
711 12
4
3
2
1
OFF MAX
MONITORVOLUME
7
56
3
4
8
AMPLIFIERSELECT
1
11
12
9
10
2
10
654321
-10 -5 0 3 6
AM4120 amperes
TEST MIC
EMERGENCYPAG ING PANEL
SIRENACTIVATE
POWER
FIRE
amperes
AM6000
PT1800 amperes
WEEKLYPROGR AM TIMER
CH5 CH6CH3 CH4 CH7 CH8 STATUSWEST
RELAYOUTPUTCON TA C T MELODY
CH1 CH2
ENTER DOWNUP
ACTIVEDATA
POWER
PRIORITY1
PRIORITY2
24CHDATADEC ODE R /RECEIVER
amperes
TD6240
VR7000
3
2
1
6
5
43
2
1
6
5
4
5
2
4
3
6
1
4
3
2
1 1
2
3
5
6
4
5
6amperes
ZS5602 amperes
BGM/PAGINGZO NE SELECTOR
21 3 54 6 1 2 3 4 65 ALLCALL
BACKGROUNDMUSIC PAGINGZONESELEC T ION
amperes
BP2000
BLANKPANEL
POWER
OFFSE LE C T
TUNER
CD
CASS
OFF
MASTER
MUSICSOURCE
SIGIN
BASS
MAXMIN
EXTINPUT
MAX MAXMIN
SOURCE
MIN
SIGIN
CHIME MIXER TREBLE
MAXMIN
TONECTRL
CH5 CH6CH4
SIGINSIGIN SIGIN
MAXMIN MAXMIN MIN
CH3CH1 CH2
SIGINSIGIN
MAXMIN MAXMIN MAXMIN MAX
AUX
SIGIN
PREAMPLIFIER MIXER
amperes
MX2222 O
I
CH1 CH2 CH4CH3 CH5 CH6
STATUS
MENU ENTER NEXTPRE
BUZZER
NORMAL
FAULT
SPEAKERLINE SURVEILLANCE
LS4600 amperes
BATTERY
9400
PS
REGULATEDDC P OW ER SUPPLY
DCOUT
MAINS
POWER
amperes
O
I
STANDBYAMPLIFIER CHANGEOVER
STANDBYTAKEOVER
NORMAL
AC3601 amperes
21 3 54 6
AUTOSTANDBYAMP CHANGEOVER
FAULT
STANDBY
5 64321
ON/OFF
BUZZER
AMP/LINE
ALERT
FAULT
AMP.FAULT/LINEG ND
AMP.NUMBER
AMP.OPERATIONAL
AX700
amperes
amperes
MxP2188
MONITORSPEAKER
LOCALPAGEZONE
t11.25;SPEAKERVOLUME
8
7
6
5
4
3
2
1
MONITORALL
EMER
DOWN
UP
PRE NEXT
PAGE
ZONE5
ZONE6
ZONE7
ZONE8ZONE4
ZONE3
ZONE2
ZONE1
MatrimixPaging
8x8MATRIXMIXER
VP1000 amperes
VENTPANEL
MENU
amperes
O
I
POWER
UP
DOWN
Q
uantum
2000SERIES
QP2500
500WPOWERAMPL IF IE R
ACTIVEDATA
POWER
PRIORITY1
PRIORITY2
8CHDATADEC ODE R/ZONESE L E C T OR
amperes
TD6080
OVERRIDE
21 3 54 6 7 8 ALLCALL
O
I
VOLUME
HEADPHONE
MONITORSPEAKER
MP3/CDPLAYE R /TUNER
POWER
CD1001
amperes
APS SCAN
MEMORY BAN
RESET
-
+
MUTESOURCE
SHUF RPT
AX3700
AMPLIFIERAUTO F AU LT CHANGEOVER
AMP.FAULT
AMP.CHANGEOVER
AMP.NORMAL
5 64321 6
PILOTTONE
STANDBYAMP.FAUL T
AMP.NUMBER
ON/OFF
BUZZER
AMP/LINE
ALERT
FAULT
PILOTTONE
STANDBYAMP.FAUL T
ON/OFF
BUZZER
AMP/LINE
ALERT
FAULT amperes
MENU
amperes
O
I
POWER
UP
DOWN
Q
uantum
2000SERIES
QP2500
500WPOWERAMPL IF IE R
MENU
amperes
O
I
POWER
UP
DOWN
Q
uantum
2000SERIES
QP2500
500WPOWERAMPL IF IE R
R
or
audio &
data
audio only
24V DC Power
R
Audio to
Mixer
RS485 for Zone
Controls
Remote Location such as Guard
House, Reception etc
iPX5400
1. Connecting PD series paging mic to iPX5400
This is usually applied when it is required to install a paging microphone a distance away from the rack such as guard house,
remote office or at different building.
Audio ( line level output ) and RS485 output shall be connected to iPX5400 as per diagram below, and at the receiving end,
audio shall be fed to mixer and the RS485 data shall go to TD decoder for zone activation. In this mode, duplex operation is
allowed.
3. Transmitting Music / Audio via iPX5400
iPX5400 allows high quality music audio to be transmitted via existing LAN or fiber optic. They works in pair at simplex mode.
Analogue input to iPX5400 shall be assigned as transmitter and the other end as receiver.
For voice audio, iPX5400 can work in full duplex mode
iPX5400
Amp / Mixer
Decoder
data
audio
Cat5e / Cat 6 ( crossed ) or
Fiber optic cable via LAN - FO
converter or through existing
LAN
PD Series Mic iPX5400
data AB
EX2800
audio
7 9
7
10
PM1000 Mic
iPX5400
PM1000
amperes
PAGINGMICROPHONE
CHIME&TALK
PUSHTOTALK
audio
remote trigger
iPX5400
Amp / Mixer
24V or contact if applicable
Cat5e / Cat 6 ( crossed ) or
Fiber optic cable via LAN - FO
converter or through existing
LAN
69510
Music Player
iPX5400
audio
iPX5400
Amp / Mixer
audio output
Cat5e / Cat 6 ( crossed ) or
Fiber optic cable via LAN - FO
converter or through existing
LAN 10
9

Device Setup Via Browser
PAGE 4 iPX5400 | ETHERNET TRANSCEIVER
iPX5400 shall require some simple setups, kindly follow the step by step instructions as listed below. The unit shall be
connected to LAN network to form a complete system. The default IP address is 192.168.0.100. Login page shall appear
and the default User ID and Password are both “admin”.
Device Info
The first page that appears is the Device Information
screen which indicates the firmware versions and
network information.
No configuration is required in this page.
Network Configuration
Change the IP address from the default , subnet and
gateway addresses to suit your networking environment.
It is recommended to leave the Data Port unchanged.
Click “Save” button to store changes.

iPX5400 | ETHERNET TRANSCEIVER PAGE 5
Device Setup Via Browser
System Configurations
DEVICE NAME :
We can enter a more meaningful device name for the unit for easier
recognition.
AUTHENTICATION :
User name and password can be stored to avoid unnecessary
access to the system.
BACK UP AND RESTORE :
We can back up or restore system settings such as IP address, IP
bridge and audio configurations.
Device Configurations
IPX BRIDGE CONFIGURATION :
iPX5400 works in pair. Enter the other unit’s IP address for pairing.
AUDIO TRANSMISSION :
Several modes of audio transmission is available such as -
Always On - allows the transmitter to send audio continuously .
Remote Trigger - audio will only streamed to receiver when remote
trigger is activated. The streaming shall be continous until the
trigger is removed.
AUDIO CONFIGURATION :
We can adjust the volume being transmitted with simple 5 band EQ.

PAGE 6 iPX5400 | ETHERNET TRANSCEIVER
Firmware Update
Click the Upload Firmware button to find the
updated firmware file. Find the updated firmware file.
Ready to upload, click Upload
button to upload the firmware.
Updating progress
After finish updating firmware, the browser automati-
cally restart.
IPX5400.acfr
IPX5400.acfr
IPX5400.acfr
IPX5400.acfr
System firmware shall be updated once in a while when new features are available or to fix bugs. There are 2 methods of
doing;
1. Open a browser and type in the iPX5400 IP Address.
2. Under “System ” page look for “Firmware Update” section as shown in below.
Update firmware in Normal Operation Mode:
Click “Choose File” and choose a binary file with “acfr” extension. Click
“Update”.
Once the update is completed, the browser should enter the login page.
1. Press & hold the reset button until “ STREAMING ” LED is turned ON. This will set the IP address to default address
192.168.0.100.
2. Open a browser and enter the IP address 192.168.0.100. A web page as shown below shall appear.
3. Select “ Upload Firmware ”, choose a binary file with “ .acfr ” extension and click “UPLOAD”
4. Once the uploading is completed, the browser shall enter the login page.
Update firmware in Bootloader Mode:
If the iPX5400 “hanged”, it is required to perform system reset by :

iPX5400 | ETHERNET TRANSCEIVER PAGE 7
Summary of Features
Note:
The above specifications are correct at time of printing but subjected to changes without prior notice due to product
improvements.
Technical Specification
Low latency audio and data transceiver
RS485 and voice at full duplex ; music audio at simplex
IP Paging server / network switch not required
Supports automatic link crossover
Setup via browser, controlable via PMX software
Supports 2 modes ;
- Always On
- On on remote trigger or through API
•
•
•
•
•
•
Power requirement :
Voltage
Current
Power consumption
Connectivity
- LAN interface
- Protocols
Audio
- Analogue input ( max )
- Analogue output (max)
- Input impedance
- Input capacitance
- Total harmonic distortion (THD)
- S/N ratio (full scale signal)
User interface
Firmware upgrade
Operating conditions
- Temperature
- Humidity
Case :
Dimension (WxHxD)
Weight
18 - 24V DC (Normal DC 24V)
60 mA
1.5W
RJ-45, 10/100T Base
TCP/IP, UDP, IGMP, HTTP, UDMP, ADP
3.2V rms (line)
2.8V rms ( with max input 3.2V )
10K Ohm
100 pF
0.1 %
83 dB
Google Chrome, MS Edge
via Web Browser
-20 - 80 C
0 - 70%
100 x 147 x 40 mm
320 g

Warranty Conditions
Disclaimer
AMPERES ELECTRONICS SDN BHD
MADE IN MALAYSIA
Updated : APRIL 2022
ISO 9001: 2008
Design & Manufacture of Public Address Equipment and Systems
Certicate No. 16895 / A / 0001 / UK / En
Only Amperes Electronics Service Centres are allowed to make warranty repairs : a list of Amperes
Electronics Service Centres may be asked for by the purchaser or send directly to Amperes Electronics Sdn
Bhd at 70 Jalan Industri PBP 3, Tmn Perindustrian Pusat Bandar Puchong, 47100, Puchong, Selangor,
Malaysia or its authorized dealers. This warranty is not valid if repairs are performed by unauthorized
personnel or service centres.
This warranty covers only repairs and replacement of defective parts ; cost and risks of transportation as
well as removal and installation of the product from the main system are for the account of the purchaser.
This warranty shall not extend to the replacement of the unit.
This warranty does not cover damages caused by misuse, neglect, accident of the product as well as using
the product with power supply voltage other than shown on the product, or any other power supply source /
adaptor not recommended by the manufacturer.
This warranty does not cover damages caused by fire, earthquakes, floods, lightning and every cause not
directly related to the unit.
This warranty does not include any indemnity in favor of the purchaser or the dealer for the period out of use
of the unit; moreover the warranty does not cover any damages which may be caused to people and things
when using the product.
This warranty certificate is valid only for the described product, and is not valid if modifications are made on
this certificate or on the identification label applied on the product.
This warranty covers all the material and manufacturing defects and is valid for a period of 36 months from
the date of purchase or for a specified period in countries where this is stated by a national law. In this case,
the extension is valid only in the country where the product is purchased.
Amperes Electronics Sdn Bhd is not obliged to modify previously manufactured products under warranty if
the design changes or improvements are made.
Information contained in this manual is subject to change without prior notice and does not represent a
commitment on the part of the vendor. AMPERES ELECTRONICS SDN BHD shall not be liable for any loss
or damages whatsoever arising from the use of information or any error contained in this manual.
It is recommended that all services and repairs on this product be carried out by AMPERES ELECTRONICS
SDN BHD or its authorized service agents.
AMPERES series must only be used for the purpose they were intended by the manufacturer and in
conjunction with this operating manual.
AMPERES ELECTRONICS SDN BHD cannot accept any liability whatsoever for any loss or damages
caused by service, maintenance or repair by unauthorized personnel, or by use other than that intended by
the manufacturer.
Table of contents
Other Amperes Transceiver manuals
Popular Transceiver manuals by other brands

Kenwood
Kenwood ProTalk TK-3201 instruction manual

City Theatrical
City Theatrical SHoW DMX SHoW Baby user manual

Standart Horizont
Standart Horizont HX407 owner's manual

B&G
B&G V90S quick start guide

VictelGlobal
VictelGlobal ALK300 series Operation manual

Cactus
Cactus Wireless Flash Transceiver V6 user manual