Warranty Information
ATT100-T40 is designed and manufactured in England by Ampetronic Ltd.
DECLARATION OF CONFORMITY
Manufacturer: Ampetronic Ltd.
Address: Northern Road, Newark,
Nottinghamshire, NG24 2ET.
United Kingdom.
Declares that the product:
Description: Input Adapter
Type Name: ATT100-T40
December 2011
This product carries a five year parts and labour warranty from date of shipment
from Ampetronic. To qualify for the five year warranty, the product must be
registered at www.ampetronic.com (products/warranty), without which the
warranty will be valid for two years only.
The warranty could be invalidated if the instructions in this handbook are not
followed correctly, or if the unit is misused in any way.
Conforms to the following Directive(s) and Norm(s):
Directive 2004/108/EC
EMC: EN55103-1 : 2009 Emission
EN55103-2 : 2009 Immunity
Directive 2006/95/EC
Safety: EN60065 : 2002
Date:
J.R. Pieters
Managing Director
Ampetronic Ltd.
TheATT100-T40 is designed to interface a low power 4 to 16 ohm speaker system
or line level output to an electret microphone input such as those found on the
Ampetronic CLD1 and ILD100 induction loop amplifiers. The unit provides a
transformer isolated attenuation of 40dB.
Restrictions on usage
The ATT100-T40 is not suitable for use with balanced or line level inputs. It should
only be connected to inputs intended for unbalanced electret microphones.
1. Output connection.
The ATT100-T40 is terminated in a 3.5mm mono jack plug. This should be
plugged directly into the microphone input of the CLD1 or ILD100 It should only be
connected to inputs intended for unbalanced electret microphones.
Under no circumstances should the output cable be extended, not even using a
screened cable. The extended connection would be susceptible to interference.
ATT100-T40
Adapter
+
-
FROM SPEAKER / LINE
OUTPUT
SAFETY
EARTH
(IF FITTED)
INSIDE VIEW OF CONNECTOR
}
2. Speaker line connection
The low impedance speaker system should be connected to the 3-pin input plug
as shown below.
Plug intoATT100-T40 then adjust input gain on the amplifier as required.
Safety Notice
The ATT100-T40 contains connections to speaker systems which may carry
hazardous voltages. If any damage to the unit is visible do not use the ATT100-
T40, but switch off all attached systems and disconnect the unit from them
before switching on again. Never attempt to open or modify the unit.
UP13006-4
Ampetronic Ltd,
Northern Road, Newark,
Nottinghamshire, NG24 2ET
United Kingdom
Tel: +44 (0) 1636 610062 Fax: +44 (0) 1636 610063
www.ampetronic.com Email: [email protected]
Warranty Information
ATT100-T40 is designed and manufactured in England by Ampetronic Ltd.
DECLARATION OF CONFORMITY
Manufacturer: Ampetronic Ltd.
Address: Northern Road, Newark,
Nottinghamshire, NG24 2ET.
United Kingdom.
Declares that the product:
Description: Input Adapter
Type Name: ATT100-T40
December 2011
This product carries a five year parts and labour warranty from date of shipment
from Ampetronic. To qualify for the five year warranty, the product must be
registered at www.ampetronic.com (products/warranty), without which the
warranty will be valid for two years only.
The warranty could be invalidated if the instructions in this handbook are not
followed correctly, or if the unit is misused in any way.
Conforms to the following Directive(s) and Norm(s):
Directive 2004/108/EC
EMC: EN55103-1 : 2009 Emission
EN55103-2 : 2009 Immunity
Directive 2006/95/EC
Safety: EN60065 : 2002
Date:
J.R. Pieters
Managing Director
Ampetronic Ltd.
TheATT100-T40 is designed to interface a low power 4 to 16 ohm speaker system
or line level output to an electret microphone input such as those found on the
Ampetronic CLD1 and ILD100 induction loop amplifiers. The unit provides a
transformer isolated attenuation of 40dB.
Restrictions on usage
The ATT100-T40 is not suitable for use with balanced or line level inputs. It should
only be connected to inputs intended for unbalanced electret microphones.
1. Output connection.
The ATT100-T40 is terminated in a 3.5mm mono jack plug. This should be
plugged directly into the microphone input of the CLD1 or ILD100 It should only be
connected to inputs intended for unbalanced electret microphones.
Under no circumstances should the output cable be extended, not even using a
screened cable. The extended connection would be susceptible to interference.
ATT100-T40
Adapter
+
-
FROM SPEAKER / LINE
OUTPUT
SAFETY
EARTH
(IF FITTED)
INSIDE VIEW OF CONNECTOR
}
2. Speaker line connection
The low impedance speaker system should be connected to the 3-pin input plug
as shown below.
Plug intoATT100-T40 then adjust input gain on the amplifier as required.
Safety Notice
The ATT100-T40 contains connections to speaker systems which may carry
hazardous voltages. If any damage to the unit is visible do not use the ATT100-
T40, but switch off all attached systems and disconnect the unit from them
before switching on again. Never attempt to open or modify the unit.
UP13006-4
Ampetronic Ltd,
Northern Road, Newark,
Nottinghamshire, NG24 2ET
United Kingdom
Tel: +44 (0) 1636 610062 Fax: +44 (0) 1636 610063
www.ampetronic.com Email: [email protected]

Other Ampetronic Adapter manuals

Ampetronic ATT100-T70 User manual

Ampetronic

Ampetronic ATT100-T70 User manual

Ampetronic ATT100-T42 User manual

Ampetronic

Ampetronic ATT100-T42 User manual

Ampetronic ATT100-T74 User manual

Ampetronic

Ampetronic ATT100-T74 User manual

Ampetronic ATT100-T60 User manual

Ampetronic

Ampetronic ATT100-T60 User manual

Ampetronic ATT30 User manual

Ampetronic

Ampetronic ATT30 User manual

Ampetronic ATT100 User manual

Ampetronic

Ampetronic ATT100 User manual

Ampetronic ATT100-T50 User manual

Ampetronic

Ampetronic ATT100-T50 User manual

Popular Adapter manuals by other brands

Edimax EW-7822ULC / UT user manual

Edimax

Edimax EW-7822ULC / UT user manual

ZyXEL Communications NWD6605 quick start guide

ZyXEL Communications

ZyXEL Communications NWD6605 quick start guide

Goobay 45354 manual

Goobay

Goobay 45354 manual

Fujitsu Stylistic LT 800P installation instructions

Fujitsu

Fujitsu Stylistic LT 800P installation instructions

Cisco ATA 191 Administration guide

Cisco

Cisco ATA 191 Administration guide

Edimax Adaptor user manual

Edimax

Edimax Adaptor user manual

VDO ADAPTOR KIT X39.106 manual

VDO

VDO ADAPTOR KIT X39.106 manual

3idee hp-pro Assembly instructions

3idee

3idee hp-pro Assembly instructions

iSystem MPC5 /SPC5 Series user manual

iSystem

iSystem MPC5 /SPC5 Series user manual

Airlink101 APL8512 user manual

Airlink101

Airlink101 APL8512 user manual

Edimax EW-7811UAC user manual

Edimax

Edimax EW-7811UAC user manual

GDC CLA-2000 user manual

GDC

GDC CLA-2000 user manual

Elnec 70-0071 manual

Elnec

Elnec 70-0071 manual

Jabra Link 380c MS quick start guide

Jabra

Jabra Link 380c MS quick start guide

Mercusys MP500 KIT Quick installation guide

Mercusys

Mercusys MP500 KIT Quick installation guide

Asoka PlugLink HD AV ECo PL9661-ETH user guide

Asoka

Asoka PlugLink HD AV ECo PL9661-ETH user guide

Xantech CSM1 installation instructions

Xantech

Xantech CSM1 installation instructions

Grandstream Networks HT802 user manual

Grandstream Networks

Grandstream Networks HT802 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.