.The ATT100-T50 is designed to interface a medium power low impedance
speaker system to an electret microphone input such as those found on the
Ampetronic CLD1 and ILD100 induction loop amplifiers. The unit provides a
transformer isolated attenuation of 50dB.
Restrictions on usage
The ATT100-T50 is not suitable for use with balanced or line level inputs. It should
only be connected to inputs intended for unbalanced electret microphones.
1. Output connection.
The ATT100-T50 should be plugged directly into the microphone input of an
Ampetronic loop driver such as the CLD1 or ILD100. Note the restrictions listed
above.
Under no circumstances should the output be extended, not even using a
screened cable. The extended connection would be susceptible to interference.
ATT100-T50
Adapter
+
-
FROM SPEAKER
OUTPUT
SAFETY
EARTH
(IF FITTED)
INSIDE VIEW OF CONNECTOR
}
2. Speaker line connection
The speaker line should be connected to the 3-pin input plug as shown below.
The safety ground connection is not essential and does not connect through the
ATT100-T50. Similarly, the polarity of the speaker line connections is not critical.
Plug intoATT100-T50.
Adjust input gain on amplifier as required.
Safety Notice
The ATT100-T50 contains connections to speaker systems which may carry
hazardous voltages. If any damage to the unit is visible do not use the ATT100-
T50, but switch off all attached systems and disconnect the unit from them
before switching on again. Never attempt to open or modify the unit.
UP13003-5
Ampetronic Ltd,
Northern Road, Newark,
Nottinghamshire, NG24 2ET
United Kingdom
Tel: +44 (0) 1636 610062 Fax: +44 (0) 1636 610063
www.ampetronic.com Email: [email protected]
Warranty Information
ATT100-T50 is designed and manufactured in England by Ampetronic Ltd.
DECLARATION OF CONFORMITY
Manufacturer: Ampetronic Ltd.
Address: Northern Road, Newark,
Nottinghamshire, NG24 2ET.
United Kingdom.
Declares that the product:
Description: Input Adapter
Type Name: ATT100-T50
December 2011
This product carries a five year parts and labour warranty from date of shipment
from Ampetronic. To qualify for the five year warranty, the product must be
registered at www.ampetronic.com (products/warranty), without which the
warranty will be valid for two years only.
The warranty could be invalidated if the instructions in this handbook are not
followed correctly, or if the unit is misused in any way.
Conforms to the following Directive(s) and Norm(s):
Directive 2004/108/EC
EMC: EN55103-1 : 2009 Emission
EN55103-2 : 2009 Immunity
Directive 2006/95/EC
Safety: EN60065 : 2002
Date:
J.R. Pieters
Managing Director
Ampetronic Ltd.
.The ATT100-T50 is designed to interface a medium power low impedance
speaker system to an electret microphone input such as those found on the
Ampetronic CLD1 and ILD100 induction loop amplifiers. The unit provides a
transformer isolated attenuation of 50dB.
Restrictions on usage
The ATT100-T50 is not suitable for use with balanced or line level inputs. It should
only be connected to inputs intended for unbalanced electret microphones.
1. Output connection.
The ATT100-T50 should be plugged directly into the microphone input of an
Ampetronic loop driver such as the CLD1 or ILD100. Note the restrictions listed
above.
Under no circumstances should the output be extended, not even using a
screened cable. The extended connection would be susceptible to interference.
ATT100-T50
Adapter
+
-
FROM SPEAKER
OUTPUT
SAFETY
EARTH
(IF FITTED)
INSIDE VIEW OF CONNECTOR
}
2. Speaker line connection
The speaker line should be connected to the 3-pin input plug as shown below.
The safety ground connection is not essential and does not connect through the
ATT100-T50. Similarly, the polarity of the speaker line connections is not critical.
Plug intoATT100-T50.
Adjust input gain on amplifier as required.
Safety Notice
The ATT100-T50 contains connections to speaker systems which may carry
hazardous voltages. If any damage to the unit is visible do not use the ATT100-
T50, but switch off all attached systems and disconnect the unit from them
before switching on again. Never attempt to open or modify the unit.
UP13003-5
Ampetronic Ltd,
Northern Road, Newark,
Nottinghamshire, NG24 2ET
United Kingdom
Tel: +44 (0) 1636 610062 Fax: +44 (0) 1636 610063
www.ampetronic.com Email: [email protected]
Warranty Information
ATT100-T50 is designed and manufactured in England by Ampetronic Ltd.
DECLARATION OF CONFORMITY
Manufacturer: Ampetronic Ltd.
Address: Northern Road, Newark,
Nottinghamshire, NG24 2ET.
United Kingdom.
Declares that the product:
Description: Input Adapter
Type Name: ATT100-T50
December 2011
This product carries a five year parts and labour warranty from date of shipment
from Ampetronic. To qualify for the five year warranty, the product must be
registered at www.ampetronic.com (products/warranty), without which the
warranty will be valid for two years only.
The warranty could be invalidated if the instructions in this handbook are not
followed correctly, or if the unit is misused in any way.
Conforms to the following Directive(s) and Norm(s):
Directive 2004/108/EC
EMC: EN55103-1 : 2009 Emission
EN55103-2 : 2009 Immunity
Directive 2006/95/EC
Safety: EN60065 : 2002
Date:
J.R. Pieters
Managing Director
Ampetronic Ltd.

Other Ampetronic Adapter manuals

Ampetronic ATT100 User manual

Ampetronic

Ampetronic ATT100 User manual

Ampetronic ATT100-T74 User manual

Ampetronic

Ampetronic ATT100-T74 User manual

Ampetronic ATT100-T40 User manual

Ampetronic

Ampetronic ATT100-T40 User manual

Ampetronic ATT100-T70 User manual

Ampetronic

Ampetronic ATT100-T70 User manual

Ampetronic ATT100-T60 User manual

Ampetronic

Ampetronic ATT100-T60 User manual

Ampetronic ATT100-T42 User manual

Ampetronic

Ampetronic ATT100-T42 User manual

Ampetronic ATT30 User manual

Ampetronic

Ampetronic ATT30 User manual

Popular Adapter manuals by other brands

ST-Lab U-2080 user manual

ST-Lab

ST-Lab U-2080 user manual

Planet BT-510U user guide

Planet

Planet BT-510U user guide

Icom TV-1275 instruction manual

Icom

Icom TV-1275 instruction manual

Tripp Lite Keyspan USA-49WG Specification sheet

Tripp Lite

Tripp Lite Keyspan USA-49WG Specification sheet

CoolGear USB-8COM product manual

CoolGear

CoolGear USB-8COM product manual

Qlogic QLA234 Series quick start guide

Qlogic

Qlogic QLA234 Series quick start guide

Celabs C5-HDP2 instruction manual

Celabs

Celabs C5-HDP2 instruction manual

Itec C31GLAN user guide

Itec

Itec C31GLAN user guide

Qlogic QLE7280 Specifications

Qlogic

Qlogic QLE7280 Specifications

Planet WNL-U554M user manual

Planet

Planet WNL-U554M user manual

j5 create JLA160 Quick installation guide

j5 create

j5 create JLA160 Quick installation guide

Tripp Lite B015-000 Specification sheet

Tripp Lite

Tripp Lite B015-000 Specification sheet

j5 create JDA213 Quick installation guide

j5 create

j5 create JDA213 Quick installation guide

CIMmed AX500 Assembly instruction

CIMmed

CIMmed AX500 Assembly instruction

Wyrestorm WyreRing quick start guide

Wyrestorm

Wyrestorm WyreRing quick start guide

BLACKHAWK! ISO110 quick start guide

BLACKHAWK!

BLACKHAWK! ISO110 quick start guide

red lion PAPBH manual

red lion

red lion PAPBH manual

AirLive WT-2000USB user manual

AirLive

AirLive WT-2000USB user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.