USING THE AMPFIBIAN MINI
1. With nothing plugged in, connect the
MINI’s plug (1) directly into power supply
(wall) socket and switch power supply ON.
2. Switch MINI ON (2). If unit trips, unplug it
and contact place of purchase. DO NOT
USE or continue with next step.
3. Press test button labelled “T” (3). If
switch (2) trips OFF continue to step 4. If
switch (2) DOES NOT trip when test button
pressed, unplug the MINI and contact us.
DO NOT use MINI or continue to step 4.
4. Connect extension cord or operating
device to MINI’s socket (4). Avoid any strain
on the lead.
6. Switch MINI to ON position (2).
TEST MINI EVERY SIX MONTHS BY
PUSHING THE BUTTON MARKED “T”; RCD
SHOULD TRIP IMMEDIATELY, IF NOT, CALL
AN ELECTRICIAN OR CONTACT
AMPFIBIAN.
IF AMPFIBIAN MINI TRIPS IN SERVICE
First rule out that the MINI is at fault by
performing the above test procedure.
The MINI will trip due to overload or an
earth leakage fault. If you are unsure of the
cause, or you believe there is an earth
leakage fault, turn off all power and
contact a licensed electrician.
If you believe there is an overload, switch
off or unplug some of the appliances and
reset the MINI.
The Ampfibian MINI is rated 240 Volts with
a maximum current rating of 10A.
Do not try to open or repair the MINI
yourself. No user-serviceable parts are
inside. If the supply cord is damaged, it
shall be replaced by the manufacturer or
its service agent in order to avoid a hazard.
Test the MINI before use as described in
step 3. This device will only protect against
faults to earth through the body, but not
against active to neutral faults.
This device must be connected DIRECTLY
to an outlet socket. It must not be
connected via cord extension sets.
To achieve the Ampfibian MINI’s ingress
protection rating of IP33 (water spray up
to 60 degrees from vertical), it must sit on
a hard floor with the RCD/MCB facing
downwards and the markings “THIS WAY
UP” facing upwards. The MINI is intended
to be used indoors or undercover.
WARNING: ELECTRICITY CAN BE
DANGEROUS! RCDs (RESIDUAL CURRENT
DEVICES) ARE NOT A SUBSTITUTE FOR
BASIC ELECTRICAL SAFETY
PRECAUTIONS. RCDs ARE ADDITIONAL
PROTECTION AND WILL NOT PREVENT
SHOCK, BUT WILL MINIMISE THE EFFECT.
RCDs WILL TRIP FOR A FAULT BETWEEN
THE BODY TO EARTH, BUT NOT FOR
ACTIVE TO NEUTRAL FAULTS. DO NOT USE
THIS DEVICE IF IT FAILS TO OPERATE
CORRECTLY IN ACCORDANCE WITH
THESE INSTRUCTIONS.
Do not expose to petrol, oil, solvents, pool
chemicals, etc.
Do not use in hazardous locations!
Do not use if damaged!
Do not disassemble!
Ingress protected to IP33,
recommended for indoor use.
Do not submerge in water!
This product is not intended for
permanent installation.
Store in a dry place out of direct sunlight.
To be used with 10A (2400W) max. load.
No.
DESCRIPTION
1 POWER PLUG
2 RCBO ON/OFF TOGGLE SWITCH
3 RCBO TEST BUTTON
4 SOCKET FOR DEVICE
RCD = Residual Current Device
MCB = Miniature Circuit Breaker
RCBO = Combination RCD + MCB
1
2
3
4
OPERATING
POSITION
THIS WAY UP!
ampfibian.com.au
ampfibian.co.nz
Freecall Australia
1800 342-426
LIKE US ON FACEBOOK!
AMPFIBIAN MINI 15A to 10A Power Adaptor with RCD and MCB
Mfgr.# 02234
LIMITED WARRANTY
Every Ampfibian product is thoroughly inspected and tested before leaving
our factory. Ampfibian Pty. Ltd. limits this warranty against defective
workmanship and faulty materials under normal use for twentyfour (24)
months from date of purchase (proof of date of purchase must be
provided) and undertakes at its option to repair or replace each product or
part thereof on condition that:
• The product has not been subject to misuse, neglect, accidents or
alterations;
• The unit has been used and maintained as per the instructions.
Ampfibian Pty. Ltd. is not liable for any consequential damage to either
people, work or facilities from using the Ampfibian.
Please ensure Ampfibian is actually faulty before returning it, by testing it
on a different power circuit and with a different appliance. Please see the
“Return & Refund Policy” page on our website or contact us for details. All
shipping costs are the responsibility of the customer.
Please staple your purchase receipt (or a copy) to this document. You will
be asked to provide a filled-out copy of this form and proof-of-purchase in
the event of a warranty claim.
DATE OF PURCHASE:
If you want an extra year’s cover free (three in total),
register your warranty online at ampfibian.com.au
Please keep these instructions with you. Only send this form to Ampfibian in
case of a warranty claim!
PURCHASED FROM:
PURCHASER’S NAME:
CONTACT INFORMATION:
RCBOs will vary from illustration & packaging.
All RCBOs have an up/down toggle switch where UP is ON;
and a test push-button marked “T”.
If there is a small window with a colour indicator, please ignore it.
ON
OFF
2
3
ON