Ampfibian MINI 15A User manual

USING THE AMPFIBIAN MINI
1. With nothing plugged in, connect the
MINI’s plug (1) directly into power supply
(wall) socket and switch power supply ON.
2. Switch MINI ON (2). If unit trips, unplug it
and contact place of purchase. DO NOT
USE or continue with next step.
3. Press test button labelled “T” (3). If
switch (2) trips OFF continue to step 4. If
switch (2) DOES NOT trip when test button
pressed, unplug the MINI and contact us.
DO NOT use MINI or continue to step 4.
4. Connect extension cord or operating
device to MINI’s socket (4). Avoid any strain
on the lead.
6. Switch MINI to ON position (2).
TEST MINI EVERY SIX MONTHS BY
PUSHING THE BUTTON MARKED “T”; RCD
SHOULD TRIP IMMEDIATELY, IF NOT, CALL
AN ELECTRICIAN OR CONTACT
AMPFIBIAN.
IF AMPFIBIAN MINI TRIPS IN SERVICE
First rule out that the MINI is at fault by
performing the above test procedure.
The MINI will trip due to overload or an
earth leakage fault. If you are unsure of the
cause, or you believe there is an earth
leakage fault, turn off all power and
contact a licensed electrician.
If you believe there is an overload, switch
off or unplug some of the appliances and
reset the MINI.
The Ampfibian MINI is rated 240 Volts with
a maximum current rating of 10A.
Do not try to open or repair the MINI
yourself. No user-serviceable parts are
inside. If the supply cord is damaged, it
shall be replaced by the manufacturer or
its service agent in order to avoid a hazard.
Test the MINI before use as described in
step 3. This device will only protect against
faults to earth through the body, but not
against active to neutral faults.
This device must be connected DIRECTLY
to an outlet socket. It must not be
connected via cord extension sets.
To achieve the Ampfibian MINI’s ingress
protection rating of IP33 (water spray up
to 60 degrees from vertical), it must sit on
a hard floor with the RCD/MCB facing
downwards and the markings “THIS WAY
UP” facing upwards. The MINI is intended
to be used indoors or undercover.
WARNING: ELECTRICITY CAN BE
DANGEROUS! RCDs (RESIDUAL CURRENT
DEVICES) ARE NOT A SUBSTITUTE FOR
BASIC ELECTRICAL SAFETY
PRECAUTIONS. RCDs ARE ADDITIONAL
PROTECTION AND WILL NOT PREVENT
SHOCK, BUT WILL MINIMISE THE EFFECT.
RCDs WILL TRIP FOR A FAULT BETWEEN
THE BODY TO EARTH, BUT NOT FOR
ACTIVE TO NEUTRAL FAULTS. DO NOT USE
THIS DEVICE IF IT FAILS TO OPERATE
CORRECTLY IN ACCORDANCE WITH
THESE INSTRUCTIONS.
Do not expose to petrol, oil, solvents, pool
chemicals, etc.
Do not use in hazardous locations!
Do not use if damaged!
Do not disassemble!
Ingress protected to IP33,
recommended for indoor use.
Do not submerge in water!
This product is not intended for
permanent installation.
Store in a dry place out of direct sunlight.
To be used with 10A (2400W) max. load.
No.
DESCRIPTION
1 POWER PLUG
2 RCBO ON/OFF TOGGLE SWITCH
3 RCBO TEST BUTTON
4 SOCKET FOR DEVICE
RCD = Residual Current Device
MCB = Miniature Circuit Breaker
RCBO = Combination RCD + MCB
1
2
3
4
OPERATING
POSITION
THIS WAY UP!
ampfibian.com.au
ampfibian.co.nz
Freecall Australia
1800 342-426
LIKE US ON FACEBOOK!
AMPFIBIAN MINI 15A to 10A Power Adaptor with RCD and MCB
Mfgr.# 02234
LIMITED WARRANTY
Every Ampfibian product is thoroughly inspected and tested before leaving
our factory. Ampfibian Pty. Ltd. limits this warranty against defective
workmanship and faulty materials under normal use for twentyfour (24)
months from date of purchase (proof of date of purchase must be
provided) and undertakes at its option to repair or replace each product or
part thereof on condition that:
• The product has not been subject to misuse, neglect, accidents or
alterations;
• The unit has been used and maintained as per the instructions.
Ampfibian Pty. Ltd. is not liable for any consequential damage to either
people, work or facilities from using the Ampfibian.
Please ensure Ampfibian is actually faulty before returning it, by testing it
on a different power circuit and with a different appliance. Please see the
“Return & Refund Policy” page on our website or contact us for details. All
shipping costs are the responsibility of the customer.
Please staple your purchase receipt (or a copy) to this document. You will
be asked to provide a filled-out copy of this form and proof-of-purchase in
the event of a warranty claim.
DATE OF PURCHASE:
If you want an extra year’s cover free (three in total),
register your warranty online at ampfibian.com.au
Please keep these instructions with you. Only send this form to Ampfibian in
case of a warranty claim!
PURCHASED FROM:
PURCHASER’S NAME:
CONTACT INFORMATION:
RCBOs will vary from illustration & packaging.
All RCBOs have an up/down toggle switch where UP is ON;
and a test push-button marked “T”.
If there is a small window with a colour indicator, please ignore it.
ON
OFF
2
3
ON
OFF

1789-INSTRUCT-MINI-Q
ampfibian.com.au
ampfibian.co.nz
Freecall Australia
1800 342-426
LIKE US ON FACEBOOK!
ADAPTOR RANGE
PRODUCT
COUNTRY
STANDARDS
COMPLIANCE
DEVICE CLASS
IMPACT RATING
LOAD SOCKET
WEATHERPROOFING
MAX. LOAD
MAX SUPPLY
SUPPLY LEAD PLUG
MINI-PLUS
NZ
AS/NZS3820
H-CLASS
IK08
16A CEE
IP44
2400W
10A
MINI
ANZ
AS/NZS3001
L-CLASS
IK08
15A
IP33
2400W
10A
MICRO
ANZ
AS/NZS3001
L-CLASS
-NA-
15A
Indoor use ONLY
2400W
10A
RV-PLUS
AUSTRALIA
AS/NZS3001
AS/NZS3190
L-CLASS
IK08
15A
IP55
2400W
10A
MAX
ANZ
AS/NZS3001
AS/NZS3190
H-CLASS
IK08
15A
IP55
2400W
10A
PC/POM/
PVC parts
Protection of the back
of the hand against
accidental access to
hazardous parts and
objects larger than
50mm
IP1_
Protection against
vertically falling water
drops
IP_1
SOLID
Ingress Rating
LIQUID
Protection of fingers
against access to
hazardous parts and
objects larger than
12.5mm
IP2_
Protection against
vertically falling water
drops up to 15° from
vertical
IP_2
Protection of persons
holding tools or wires
larger than 2.5mm
diameter
IP3_
Protection against
spraying water (rain)
at an angle up to 60°
from vertical
IP_3
Protection of persons
holding tools or wires
larger than 1mm
diameter
IP4_
Protection against
splashing water from
any direction (360°)
IP_4
Protection against
entry of dust in
sufficient quantity to
interfere with
equipment
IP5_
Protection against
water jets from any
direction (360°)
IP_5
0.5 Joules
Impact Energy
Drop of 200g object
from a height of
250mm
IK04
0.7 Joules
Impact Energy
Drop of 200g object
from a height of
350mm
IK05
1.0 Joules
Impact Energy
Drop of 500g object
from a height of
200mm
IK06
2.0 Joules
Impact Energy
Drop of 500g object
from a height of
400mm
IK07
5.0 Joules
Impact Energy
Drop of 1700g object
from a height of
295mm
IK08
Impact
Rating
A single phase portable RCD
primarily intended for household
use
L-Class
Operating Environment
A portable RCD intended for
general industrial use
H-Class
Residual Current Device:
Immediately cuts the power if a
difference between incoming and
outgoing voltage is detected.
Protects people against the
effects of electrocution
RCD
Electrical Protection
Miniature Circuit Breaker:
Cuts the power in case of
overload. Protects circuits from
overheating and catching fire
MCB
RATING KEY
Specifications subject to chang without notice!
Caused by: Caused by: Caused by:
Protection: Protection: Protection:
15A
PLUG
15A
SOCKET
All caravan electrical supply equipment must be weatherproof to at least IP44
CARAVAN
SURGE
PROTECTOR
Breaker
Fuse or M.C.B.
Miniature Circuit Breaker
Overload
DEATH-LEAD Short Circuit
Bad/old/damaged wiring Spike
Generators, lightning
FIRE SHOCK LOSS
R.C.D.
Residual Current Device Surge
Protector
Higher “Joule” rating
gives better protection
Combined into a single “R.C.B.O.”
(Residual-Current-Breaker-Overload)
15A to 10A Power Adaptors with RCD and MCB
Only available in Australia
15A Caravan
Surge Protectors
(work with Adaptors)
10A
PLUG
15A
SOCKET
RV-PLUS
MINI-PLUS is New Zealand
equivalent (MCB only)
10A
PLUG
15A
SOCKET
MAX
10A
PLUG
15A
SOCKET
10A
PLUG
15A
SOCKET
MINIMICRO
HOW AMPFIBIANS PROTECT YOU
PLEASE NOTE:
Products must be used in their
country of purchase:
- AU has an A-type RCBO
- NZ has an FS A-type RCBO
This manual suits for next models
2
Other Ampfibian Receiver manuals