Ampfibian MINI-PLUS User manual

AMPFIBIAN MAX Heavy-Duty Weatherproof 15A to 10A Power Adaptor with RCD and MCB
USING THE AMPFIBIAN MAX
1. With nothing plugged in, connect MAX
plug (11) directly into power supply (wall)
socket and switch power supply ON.
2. Switch MAX ON (15). If unit trips, unplug
it and contact us. DO NOT USE or continue
to next step.
3. Press test button labelled “T” (14). If
switch (15) trips OFF continue to step 4.
If switch (15) DOES NOT trip when test
button pressed, unplug the MAX and
contact place of purchase. DO NOT use
MAX or continue to step 4.
4. Connect extension cord (6) to the MAX
socket ensuring that the lead is captured
by the plug lid (7) and cleat (3). Avoid any
strain on the lead.
5. Connect device directly or via extension
cord/lead (6).
6. Switch MAX to ON position (15).
TEST MAX EVERY SIX MONTHS BY
PUSHING THE BUTTON MARKED “T”; RCD
SHOULD TRIP IMMEDIATELY, IF NOT, CALL
AN ELECTRICIAN OR CONTACT
AMPFIBIAN.
Both lids (7 & 8) must be latched closed
before use. Inspect seals for damage
and/or obstruction. Do not use if lids, seals
or latches are damaged or inoperable.
IF AMPFIBIAN MAX TRIPS IN SERVICE
First rule out that the MAX is at fault by
performing the above test procedure. The
MAX will trip due to overload or an earth
leakage fault. If you are unsure of the
cause, or you believe there is an earth
leakage fault, turn off all power and
contact a licensed electrician. If you
believe there is an overload, switch off or
unplug some of the appliances and reset
the MAX.
The Ampfibian MAX is rated 240 Volts with
a maximum current rating of 10A.
Do not try to open or repair the MAX
yourself. No user-serviceable parts are
inside. If the supply cord is damaged, it
shall be replaced by the manufacturer or
its service agent in order to avoid a hazard.
Test the MAX before each use as
described in step 3. This device will only
protect against faults to earth through the
body, but not against active to neutral
faults.
This device must be connected DIRECTLY
to an outlet socket. It must not be
connected via cord extension sets.
Wet seals will freeze and will not recover
their shape until thawed. Do not open
frozen unit until thawed. Opening frozen
unit may result in damage to seals.
WARNING: ELECTRICITY CAN BE
DANGEROUS! RCDs (RESIDUAL CURRENT
DEVICES) ARE NOT A SUBSTITUTE FOR
BASIC ELECTRICAL SAFETY
PRECAUTIONS. RCDs ARE ADDITIONAL
PROTECTION AND WILL NOT PREVENT
SHOCK, BUT WILL MINIMISE THE EFFECT.
RCDs WILL TRIP FOR A FAULT BETWEEN
THE BODY TO EARTH, BUT NOT FOR
ACTIVE TO NEUTRAL FAULTS. DO NOT USE
THIS DEVICE IF IT FAILS TO OPERATE
CORRECTLY IN ACCORDANCE WITH
THESE INSTRUCTIONS.
Do not expose to petrol, oil, solvents,
pool chemicals, etc.!
Do not use in hazardous locations!
Do not use if damaged!
Do not disassemble!
Ingress protected to IP55.
Do not submerge in water!
Remove condensation with a soft
absorbent cloth.
Turn off power supply before
handling connections in wet conditions!
Store in a dry place out of
direct sunlight.
Ensure there is no gap visible through
cord seals when closed! If required, leave
lid open until cord seals have fully
recovered.
This product is not intended for
permanent installation.
Do not bury.
Suitable for ordinary and heavy-duty
extension leads from 7mm to 12mm
diameter.
H-Class rated device for trade and
commercial use.
To be used with 10A (2400W)
maximum load.
Integrated flip-out
hook for hanging
ampfibian.com.au
ampfibian.co.nz
Freecall Australia
1800 342-426
Ensure cable is
positioned in
middle of cleat
No.
DESCRIPTION
1 CORD SEAL (LID)
2 PLUG LID GASKET
3 RETAINING CLEAT
4 CORD SEAL (BODY)
5 PLUG LID LATCH
6 15A LEAD (NOT SUPPLIED)
7 PLUG LID
8 RCBO LID
9 RCBO LID LATCH
10 LOCKOUT TAG
11 10A PLUG & FLY-LEAD
12 SECURITY BRACKET
13 RCBO
14 RCBO TEST BUTTON
15 RCBO TOGGLE SWITCH
16 RCBO LID GASKET
CLEAT (3)
LIKE US ON FACEBOOK!
RCBOs will vary from illustration & packaging.
All RCBOs have an up/down toggle switch where UP is ON;
and a test push-button marked “T”.
If there is a small window with a colour indicator, please ignore it.
RCD = Residual Current Device
MCB = Miniature Circuit Breaker
RCBO = Combination RCD + MCB
To open RCBO Lid (8), a use coin
or a screwdriver to push the lid
and latch (9) apart.
Raised lockout tag (10)
stops lid opening.
ON
OFF
87
11
12
15
14
13
16
3
4
5
6
2
1
ON
OFF
9 10
Mfgr.# 02897

1782-INSTRUCT-MAX-O
Protection of the back
of the hand against
accidental access to
hazardous parts and
objects larger than
50mm
IP1_
Protection against
vertically falling water
drops
IP_1
SOLID
Ingress Rating
LIQUID
Protection of fingers
against access to
hazardous parts and
objects larger than
12.5mm
IP2_
Protection against
vertically falling water
drops up to 15° from
vertical
IP_2
Protection of persons
holding tools or wires
larger than 2.5mm
diameter
IP3_
Protection against
spraying water (rain)
at an angle up to 60°
from vertical
IP_3
Protection of persons
holding tools or wires
larger than 1mm
diameter
IP4_
Protection against
splashing water from
any direction (360°)
IP_4
Protection against
entry of dust in
sufficient quantity to
interfere with
equipment
IP5_
Protection against
water jets from any
direction (360°)
IP_5
0.5 Joules
Impact Energy
Drop of 200g object
from a height of
250mm
IK04
0.7 Joules
Impact Energy
Drop of 200g object
from a height of
350mm
IK05
1.0 Joules
Impact Energy
Drop of 500g object
from a height of
200mm
IK06
2.0 Joules
Impact Energy
Drop of 500g object
from a height of
400mm
IK07
5.0 Joules
Impact Energy
Drop of 1700g object
from a height of
295mm
IK08
Impact
Rating
A single phase portable RCD
primarily intended for household
use
L-Class
Operating Environment
A portable RCD intended for
general industrial use
H-Class
Residual Current Device:
Immediately cuts the power if a
difference between incoming and
outgoing voltage is detected.
Protects people against the
effects of electrocution
RCD
Electrical Protection
Miniature Circuit Breaker:
Cuts the power in case of
overload. Protects circuits from
overheating and catching fire
MCB
RATING KEY LIMITED WARRANTY
Every Ampfibian product is thoroughly inspected and tested before leaving our
factory. Ampfibian Pty. Ltd. limits this warranty against defective workmanship
and faulty materials under normal use for twentyfour (24) months from date of
purchase (proof of date of purchase must be provided) and undertakes at its
option to repair or replace each product or part thereof on condition that:
• The product has not been subject to misuse, neglect, accidents or alterations;
• The unit has been used and maintained as per the instructions.
Ampfibian Pty. Ltd. is not liable for any consequential damage to either people,
work or facilities from using the Ampfibian.
Please ensure Ampfibian is actually faulty before returning it, by testing it on a
different power circuit and with a different appliance. Please see the “Return &
Refund Policy” page on our website or contact us for details. All shipping costs
are the responsibility of the customer.
Please staple your purchase receipt (or a copy) to this document. You will be
asked to provide a filled-out copy of this form and proof-of-purchase in the
event of a warranty claim.
DATE OF PURCHASE:
If you want an extra year’s cover free (three in total),
register your warranty online at ampfibian.com.au
SERIAL #*:
*) Located below compliance label. Please keep these instructions with you.
Only send this form to Ampfibian in case of a warranty claim!
PURCHASED FROM:
PURCHASER’S NAME:
CONTACT INFORMATION:
ampfibian.com.au
ampfibian.co.nz
Freecall Australia
1800 342-426
LIKE US ON FACEBOOK!
ADAPTOR RANGE
PRODUCT
COUNTRY
STANDARDS
COMPLIANCE
DEVICE CLASS
IMPACT RATING
LOAD SOCKET
WEATHERPROOFING
MAX. LOAD
MAX SUPPLY
SUPPLY LEAD PLUG
MINI-PLUS
NZ
AS/NZS3820
H-CLASS
IK08
16A CEE
IP44
2400W
10A
MINI
ANZ
AS/NZS3001
L-CLASS
IK08
15A
IP33
2400W
10A
MICRO
ANZ
AS/NZS3001
L-CLASS
-NA-
15A
Indoor use ONLY
2400W
10A
RV-PLUS
AUSTRALIA
AS/NZS3001
AS/NZS3190
L-CLASS
IK08
15A
IP55
2400W
10A
MAX
ANZ
AS/NZS3001
AS/NZS3190
H-CLASS
IK08
15A
IP55
2400W
10A
PC/POM/
PVC parts
Specifications subject to chang without notice!