AMPFIBIAN MAX Heavy-Duty Weatherproof 15A to 10A Power Adaptor with RCD and MCB
USING THE AMPFIBIAN MAX
1. With nothing plugged in, connect MAX
plug (11) directly into power supply (wall)
socket and switch power supply ON.
2. Switch MAX ON (15). If unit trips, unplug
it and contact us. DO NOT USE or continue
to next step.
3. Press test button labelled “T” (14). If
switch (15) trips OFF continue to step 4.
If switch (15) DOES NOT trip when test
button pressed, unplug the MAX and
contact place of purchase. DO NOT use
MAX or continue to step 4.
4. Connect extension cord (6) to the MAX
socket ensuring that the lead is captured
by the plug lid (7) and cleat (3). Avoid any
strain on the lead.
5. Connect device directly or via extension
cord/lead (6).
6. Switch MAX to ON position (15).
TEST MAX EVERY SIX MONTHS BY
PUSHING THE BUTTON MARKED “T”; RCD
SHOULD TRIP IMMEDIATELY, IF NOT, CALL
AN ELECTRICIAN OR CONTACT
AMPFIBIAN.
Both lids (7 & 8) must be latched closed
before use. Inspect seals for damage
and/or obstruction. Do not use if lids, seals
or latches are damaged or inoperable.
IF AMPFIBIAN MAX TRIPS IN SERVICE
First rule out that the MAX is at fault by
performing the above test procedure. The
MAX will trip due to overload or an earth
leakage fault. If you are unsure of the
cause, or you believe there is an earth
leakage fault, turn off all power and
contact a licensed electrician. If you
believe there is an overload, switch off or
unplug some of the appliances and reset
the MAX.
The Ampfibian MAX is rated 240 Volts with
a maximum current rating of 10A.
Do not try to open or repair the MAX
yourself. No user-serviceable parts are
inside. If the supply cord is damaged, it
shall be replaced by the manufacturer or
its service agent in order to avoid a hazard.
Test the MAX before each use as
described in step 3. This device will only
protect against faults to earth through the
body, but not against active to neutral
faults.
This device must be connected DIRECTLY
to an outlet socket. It must not be
connected via cord extension sets.
Wet seals will freeze and will not recover
their shape until thawed. Do not open
frozen unit until thawed. Opening frozen
unit may result in damage to seals.
WARNING: ELECTRICITY CAN BE
DANGEROUS! RCDs (RESIDUAL CURRENT
DEVICES) ARE NOT A SUBSTITUTE FOR
BASIC ELECTRICAL SAFETY
PRECAUTIONS. RCDs ARE ADDITIONAL
PROTECTION AND WILL NOT PREVENT
SHOCK, BUT WILL MINIMISE THE EFFECT.
RCDs WILL TRIP FOR A FAULT BETWEEN
THE BODY TO EARTH, BUT NOT FOR
ACTIVE TO NEUTRAL FAULTS. DO NOT USE
THIS DEVICE IF IT FAILS TO OPERATE
CORRECTLY IN ACCORDANCE WITH
THESE INSTRUCTIONS.
Do not expose to petrol, oil, solvents,
pool chemicals, etc.!
Do not use in hazardous locations!
Do not use if damaged!
Do not disassemble!
Ingress protected to IP55.
Do not submerge in water!
Remove condensation with a soft
absorbent cloth.
Turn off power supply before
handling connections in wet conditions!
Store in a dry place out of
direct sunlight.
Ensure there is no gap visible through
cord seals when closed! If required, leave
lid open until cord seals have fully
recovered.
This product is not intended for
permanent installation.
Do not bury.
Suitable for ordinary and heavy-duty
extension leads from 7mm to 12mm
diameter.
H-Class rated device for trade and
commercial use.
To be used with 10A (2400W)
maximum load.
Integrated flip-out
hook for hanging
ampfibian.com.au
ampfibian.co.nz
Freecall Australia
1800 342-426
Ensure cable is
positioned in
middle of cleat
No.
DESCRIPTION
1 CORD SEAL (LID)
2 PLUG LID GASKET
3 RETAINING CLEAT
4 CORD SEAL (BODY)
5 PLUG LID LATCH
6 15A LEAD (NOT SUPPLIED)
7 PLUG LID
8 RCBO LID
9 RCBO LID LATCH
10 LOCKOUT TAG
11 10A PLUG & FLY-LEAD
12 SECURITY BRACKET
13 RCBO
14 RCBO TEST BUTTON
15 RCBO TOGGLE SWITCH
16 RCBO LID GASKET
CLEAT (3)
LIKE US ON FACEBOOK!
RCBOs will vary from illustration & packaging.
All RCBOs have an up/down toggle switch where UP is ON;
and a test push-button marked “T”.
If there is a small window with a colour indicator, please ignore it.
RCD = Residual Current Device
MCB = Miniature Circuit Breaker
RCBO = Combination RCD + MCB
To open RCBO Lid (8), a use coin
or a screwdriver to push the lid
and latch (9) apart.
Raised lockout tag (10)
stops lid opening.
ON
OFF
87
11
12
15
14
13
16
3
4
5
6
2
1
ON
OFF
9 10
Mfgr.# 02897