AMTI AccuPower-Optimized Quick Start Guide
ACP-O
Quick Start Guide
Step 1: Locate the AMTI USB drive. It contains manuals and software for your force transducer.
Step 2: Locate the USB cable and connect it from the force plate to your computer’s USB port.
(page 2 of this guide)
Step 3: Install the OPTIMA drivers found in the folder ‘Optima-Gen5 Drivers’ using the instructions
on page 2 of this guide.
Step 4: Install Netforce by opening the NetForce folder and double clicking setup.exe.
Step 5: Open Netforce and run through the setup helper to configure the force plate - instructions
on Page 4 of this guide.
Step 6: View the real-time stream in NetForce to ensure you are properly connected. Instructions
can be found on page 6 of this document. If you are unable to connect consult the product
manuals. Congratulations your Force Plate is now installed!
You can now collect data through AMTINetForce.
A number of third party applications, including those used in 3D motion capture
systems, support digital integration of AMTI products. Contact us for the AMTI
USB SDK and examples written for LabVIEW, Python, C#, and more.
For more detailed information consult our full-length manuals or AMTI support
Advanced Mechanical Technology, Inc.
176 Waltham St. Watertown, MA 02478 USA
Tel: +1-617-926-6700.
Fax: +1-617-927-5045.
Phone: (617)926-6700
Website: www.amti.biz
Email: [email protected]
This guide contains abstracted information from the User Manual; please refer
to the latest manuals for complete information.

20201022
Page 2 of 4
Rev A
AMTI AccuPower-Optimized Quick Start Guide
1. USB Flash Drive - Confirm you got everything you need
This drive contains all necessary manuals, along with required software (Netforce, drivers, and other purchased
software). Also contained is a backup of the force plate’s calibration information which will automatically load
from the force plate during the installation process.
To get your force plate system running, make sure you have the following parts included in the box:
1. USB Flash Drive –Contains all software, calibration files, and manuals related to your product.
2. AccuPower-Optimized –6-DOF force platform.
3. USB Cable –USB type A to USB type B cables.
2. Force Plate Setup
a. Connect the USB cable from the force plate to a USB port on your computer.
b. For more than one plate, please consult AMTI support at helpd[email protected].
3. Driver Installation
These are instructions for driver installation on a Windows 7 computer.
a. Make sure the ACP-O is connected to the computer.
b. In Control Panel, search for the ‘Device Manager’ and click on it.
c. Locate the ACG-O /ACS-O /ACP-O device. It will likely be listed under ‘Other devices’ and
have a yellow warning on its logo.
d. Right click the ACG-O /ACS-O /ACP-O device and select ‘Update Driver Software …’(see image
below).
e. Select ‘Browse my computer for driver software’.
f. Click ‘Browse’ and navigate to the folder containing the driver files. Make sure to select the
appropriate 32-bit or 64-bit version for your operating system and then click‘OK’.
i. To determine which operating system you have click ‘Computer’ under the Windows
‘Start’ menu, then right click and select ‘Properties’.
g. Click ‘OK’ and then click ‘Next’
h. You should receive a message indicating that the drivers have been successfullyinstalled.
ACCUPOWER-Optimized
Force plate
USB cable

20201022
Page 3 of 4
Rev A
AMTI AccuPower-Optimized Quick Start Guide
4. NetForce Installation
Even if you plan to integrate your force transducer with a third party system such as a motion capture
system you must install AMTINetForce. AMTINetForce will allow you to perform the initial
configuration of your ACG-O /ACS-O /ACP-O amplifier so that it will be recognized by other systems.
Double click the Setup.exe to install the software. Click through the installation wizard. If you receive a
warning regarding a newer version of C++ simply close this window and continue on to opening
AMTINetForce. If AMTINetForce will not open you may need to install an older version of C++.
5. NetForce Setup
a. The first time you open AMTINetForce it will automatically take you through an initial setup.
If this does not open automatically access it by clicking ‘Setup’, then ‘Setup Helper’, and
‘Yes’.
b. The first window will ask if you wish to continue with the setup, click ‘Yes’
c. Next select the configuration that matches your hardware, in this case highlight ‘ACG-O /ACS-O
/ACP-O’ and click ‘OK‘
d. The ‘AMTI System Configuration’ window will open. It should auto-populate the list of ‘Installed
Amplifier’ and ‘Associated Platform’ with your amplifier model and serial number as well as the
force plate’s serial number (see figure below).
If the lists do not automatically populate check your connections and click ‘Find
Amplifiers’. The drivers need to be installed for this to work (see Step 3).

20201022
Page 4 of 4
Rev A
AMTI AccuPower-Optimized Quick Start Guide
e. In the future you can access the ‘AMTI System Configuration’ window by clicking ‘Setup’, then
‘Hardware Installation’, then ‘Modify’
f. Once the force plate is listed on this page click ‘Apply’ and then be sure to click ‘Save’. Then click
‘Done’
g. In the next window select the location where data collected through AMTINetForce should be
saved. Navigate to an appropriate folder or select the folder ‘Data’ under ‘AMTINetForce’ and
click ‘Open’, then ‘Open’.
h. Click ‘OK’ for the location of the default directory.
i. Click ‘OK’ to complete the setup and close the program.
6. View the real-time data stream
a. Open AMTINetForce (your force plate should already be installed from Step 5)
b. At the bottom left of each graph set the ‘Amp ID’ to the force plate number for which you wish
to view the data (This should be 1 or greater; no data will appear if it is set to 0).
c. Under the ‘Startup’ menu select ‘Hardware Zero’.
d. Under the ‘Settings’ menu select ‘Acquisition Settings’ and ensure that the ‘Mode’ at the
bottom right of the window is set to ‘Recurring’
e. At the bottom right of the graph window the ‘Units’ or ‘Setup’ button will allow you to set the
units, line color and scaling on the graph.
f. You can adjust which channels are displayed by toggling the channel buttons to the left of the
graph window on or off.
g. Adjust the channel’s zero position by dragging the triangle to the left of the y-axis up anddown.
h. Click the ‘Center’ then ‘Space’ button in the bottom right of each graph window to ensure all
displayed channels are visible in the window.
i. Click ‘Start’ at the bottom right of the graph window and the data will begin to stream.
j. For more information on AMTINetForce refer to the AMTINetForce UserManual.
Table of contents
Popular Network Hardware manuals by other brands

Extron electronics
Extron electronics IP Link IR Learner IPL T IRL Specification sheet

Nautilus
Nautilus QU-BIT manual

ESD electronic
ESD electronic CAN-PCI/266 Hardware installation and technical data

Ebyte
Ebyte E83-2G4M03S user manual

8e6 Technologies
8e6 Technologies Enterprise Filter Authentication R3000 quick start guide

UTC Fire and Security
UTC Fire and Security Edwards MN-COM1S Installation sheet

ETAS
ETAS ES1337.2 user guide

Vivotek
Vivotek ND8321 user manual

Cisco
Cisco Secure Firewall Management Center 1700 Getting started guide

Roving Networks
Roving Networks RN-171 User manual and command reference

ZyXEL Communications
ZyXEL Communications NSA-220 Plus user guide

Danfoss
Danfoss TFX Installation and operation manual