Ciena 3902 Installation and operation manual

3902 Service Delivery Switch Hardware Installation and Start-up Manual
009-3205-001 Standard Revision D
Copyright©2013-2015 Ciena®Corporation July 2015
LEGAL NOTICES
THIS DOCUMENT CONTAINS TRADE SECRET INFORMATION OF CIENA CORPORATION AND
ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE OR DISCLOSE ITS
CONTENTS, OR TO MANUFACTURE, USE, OR SELL ANYTHING THAT IT MAY DESCRIBE. REPRODUCTION,
DISCLOSURE, OR USE IN WHOLE OR IN PART WITHOUT THE SPECIFIC WRITTEN AUTHORIZATION
OF CIENA CORPORATION IS STRICTLY FORBIDDEN.
EVERY EFFORT HAS BEEN MADE TO ENSURE THAT THE INFORMATION IN THIS DOCUMENT IS
COMPLETE AND ACCURATE AT THE TIME OF PUBLISHING; HOWEVER, THE INFORMATION CONTAINED IN
THIS DOCUMENT IS SUBJECT TO CHANGE.
While the information in this document is believed to be accurate and reliable, except as otherwise expressly
agreed to in writing CIENA PROVIDES THIS DOCUMENT “AS IS” WITHOUT WARRANTY OR CONDITION OF
ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are
subject to change without notice.
Copyright©2013-2015 Ciena®Corporation. All Rights Reserved
The material contained in this document is also protected by copyright laws of the United States of America and
other countries. It may not be reproduced or distributed in any form by any means, altered in any fashion, or stored
in a data base or retrieval system, without express written permission of the Ciena Corporation.
Security
Ciena®cannot be responsible for unauthorized use of equipment and will not make allowance or credit for
unauthorized use or access.
Contacting Ciena
For additional office locations and phone numbers, please visit the Ciena web site at www.ciena.com.
Corporate Headquarters 410-694-5700 or 800-921-1144 www.ciena.com
Customer Technical Support/Warranty
In North America 1-800-CIENA24 (243-6224)
410-865-4961
In Europe, Middle East,
and Africa 800-CIENA-24-7 (800-2436-2247)
+44-207-012-5508
In Asia-Pacific 800-CIENA-24-7 (800-2436-2247)
+81-3-6367-3989
+91-124-4340-600
In Caribbean and Latin
America 800-CIENA-24-7 (800-2436-2247)
410-865-4944 (USA)
In India +91-124-434-0500 E-mail: sales@ciena.com
Training 877-CIENA-TD (243-6283)

3902 Service Delivery Switch Hardware Installation and Start-up Manual
009-3205-001 Standard Revision D
Copyright©2013-2015 Ciena®Corporation July 2015
IMPORTANT: PLEASE READ THIS LICENSE AGREEMENT (“AGREEMENT”) CAREFULLY BEFORE
INSTALLING OR USING CIENA CORPORATION (“Ciena”) SOFTWARE, HARDWARE OR DOCUMENTATION
(COLLECTIVELY, THE “EQUIPMENT”).
BY INSTALLING OR USING THE EQUIPMENT, YOU ACKNOWLEDGE THAT YOU HAVE READ THIS
AGREEMENT AND AGREE TO BE BOUND BY ITS TERMS AND CONDITIONS.
1. Right to Use License; Restrictions. Subject to these terms, and the payment of all applicable license fees,
Ciena grants to you, as end user, a non-exclusive license to use the Ciena software (the “Software”) in object code
form solely in connection with, and as embedded within, the Equipment,. You shall have the right to use the
Software solely for your own internal use and benefit. You may make one copy of the Software and documentation
solely for backup and archival purpose, however you must reproduce and affix all copyright and other proprietary
rights notices that appear in or on the original. You may not, without Ciena's prior written consent, (i) sublicense,
assign, sell, rent, lend, lease, transfer or otherwise distribute the Software; (ii) grant any rights in the Software or
documentation not expressly authorized herein; (iii) modify the Software nor provide any third person the means to
do the same; (iv) create derivative works, translate, disassemble, recompile, reverse engineer or attempt to obtain
the source code of the Software in any way; or (v) alter, destroy, or otherwise remove any proprietary notices or
labels on or embedded within the Software or documentation. You acknowledge that this license is subject to
Section 365 of the U.S. Bankruptcy Code and requires Ciena's consent to any assignment related to a bankruptcy
proceeding. Sole title to the Software and documentation, to any derivative works, and to any associated patents
and copyrights, remains with Ciena or its licensors. Ciena reserves to itself and its licensors all rights in the
Software and documentation not expressly granted to you. You shall preserve intact any notice of copyright,
trademark, logo, legend or other notice of ownership from any original or copies of the Software or documentation.
2. Audit: Upon Ciena's reasonable request, but not more frequently than annually without reasonable cause, you
shall permit Ciena to audit the use of the Software at such times as may be mutually agreed upon to ensure
compliance with this Agreement.
3.U.S. Government Use. The Software is provided to the Government only with restricted rights and limited rights.
Use, duplication, or disclosure by the Government is subject to restrictions set forth in FAR Sections 52-227-14 and
52-227-19 or DFARS Section 52.227-7013(C)(1)(ii), as applicable. The Equipment and any accompanying technical
data (collectively “Materials”) are commercial within the meaning of applicable Federal acquisition regulations.
These Materials were developed fully at private expense. U.S. Government use of the Materials is restricted by this
Agreement, and all other U.S. Government use is prohibited. In accordance with FAR 12.212 and DFAR
Supplement 227.7202, software delivered to you is commercial computer software and the use of that software is
further restricted by this Agreement.
4.Term of License. This license is effective until terminated. Customer may terminate this license at any time by
giving written notice to Ciena [or] and destroying or erasing all copies of Software including any documentation.
Ciena may terminate this Agreement and your license to the Software immediately by giving you written notice of
termination in the event that either (i) you breach any term or condition of this Agreement or (ii) you are wound up
other than voluntarily for the purposes of amalgamation or reorganization, have a receiver appointed or enter into
liquidation or bankruptcy or analogous process in your home country. Termination shall be without prejudice to any
other rights or remedies Ciena may have. In the event of any termination you will have no right to keep or use the
Software or any copy of the Software for any purpose and you shall destroy and erase all copies of such Software in
its possession or control, and forward written certification to Ciena that all such copies of Software have been
destroyed or erased.
5.Compliance with laws. You agree to comply with all applicable laws, including all import regulations, and to
obtain all required licenses and permits related to installation and use of Equipment. Software, including technical
data, is subject to U.S. export control laws, including the U.S. Export Administration Act and its associated
regulations, and may be subject to export or import regulations in other countries. Customer agrees to comply
strictly with all such regulations and acknowledges that it has the responsibility to obtain licenses to export, re-
export, or import Software.

3902 Service Delivery Switch Hardware Installation and Start-up Manual
009-3205-001 Standard Revision D
Copyright©2013-2015 Ciena®Corporation July 2015
6.Limitation of Liability. ANY LIABILITY OF Ciena SHALL BE LIMITED IN THE AGGREGATE TO THE
AMOUNTS PAID BY YOU FOR THE SOFTWARE. THIS LIMITATION APPLIES TO ALL CAUSES OF ACTION,
INCLUDING WITHOUT LIMITATION BREACH OF CONTRACT, BREACH OF WARRANTY, NEGLIGENCE,
STRICT LIABILITY, MISREPRESENTATION AND OTHER TORTS. THE LIMITATIONS OF LIABILITY
DESCRIBED IN THIS SECTION ALSO APPLY TO ANY THIRD-PARTY SUPPLIER OF Ciena. NEITHER Ciena
NOR ANY OF ITS THIRD-PARTY SUPPLIERS SHALL BE LIABLE FOR ANY INJURY, LOSS OR DAMAGE,
WHETHER INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL INCLUDING WITHOUT LIMITATION ANY
LOST PROFITS, CONTRACTS, DATA OR PROGRAMS, AND THE COST OF RECOVERING SUCH DATA OR
PROGRAMS, EVEN IF INFORMED OF THE POSSIBILITY OF SUCH DAMAGES IN ADVANCE
7.General. Ciena may assign this Agreement to any Ciena affiliate or to a purchaser of the intellectual property
rights in the Software, but otherwise neither this Agreement nor any rights hereunder may be assigned nor duties
delegated by either party, and any attempt to do so will be void. This Agreement shall be governed by the laws of
the State of Maryland (without regard to the conflict of laws provisions) and shall be enforceable in the courts of
Maryland. The U.N. Convention on Contracts for the International Sale of Goods shall not apply hereto. This
Agreement constitutes the complete and exclusive statement of agreement between the parties relating to the
license for the Software and supersedes all proposals, communications, purchase orders, and prior agreements,
verbal or written, between the parties. If any portion hereof is found to be void or unenforceable, the remaining
provisions shall remain in full force and effect.

v
3902 Service Delivery Switch Hardware Installation and Start-up Manual
009-3205-001 Standard Revision D
Copyright©2013-2015 Ciena®Corporation July 2015
Publication History 0
October 2012
•Revision A, Standard:
— Document assigned a new document number. This document
replaces the document 009-2011-378.
— Overview material has been moved to 39XX/51XX Product
Fundamentals
— Optics information remains in Packet Networking Transceivers
Reference (009-2011-602)
— Orderable part number information removed. For ordering assistance
please contact your Ciena representative.
September 2013
•Revision B, Standard:
— Minor maintenance changes to reincorporate notes and cautions in
the installation chapter and to add a note to the procedure for creating
a remote management interface.
— Rebrand portfolio as Packet Networking (was Carrier Ethernet
Solutions).
— Update name for the transceiver reference to Packet Networking
Transceivers Reference (009-2011-602) and the glossary to Packet
Networking Glossary (009-3299-026)
— Add new appendix covering reset button information
April 2015
•Revision C, Standard:
— Minor update to procedure “Logging in through the Serial Console
Port” on page 3-6.
— Minor update to procedure “Creating a New User Account” on page
3-7.

vii
3902 Service Delivery Switch Hardware Installation and Start-up Manual
009-3205-001 Standard Revision D
Copyright©2013-2015 Ciena®Corporation July 2015
Contents 0
About this Document ix
Overview 1-1
Installation 2-1
Important Safety Information 2-1
Installation Overview 2-2
Mounting the 3902 2-3
Required Tools and Accessories 2-3
Installing the Power Supply 2-4
Installing the SFP 2-4
Installing the Interface Cabling 2-5
Fiber Optic Cable 2-5
Ethernet Cable 2-5
Initial configuration 2-6
2-1 Mounting the 3902 2-7
2-2 Installing Power to the 3902 2-8
2-3 Installing an SFP 2-9
2-4 Installing a Fiber Optic Cable 2-10
Turning Up the System 3-1
Logging in through the Serial Console Port 3-1
Creating a New User Account 3-1
Deleting a User Account 3-3
Managing Licenses 3-3
Configuring the Remote Management Interface 3-3
Accessing the CLI Using Telnet 3-4
Configuring an Interface using DHCP 3-4
Setting the System Host Name 3-4
Logging out of the system 3-5
List of procedures
3-1 Logging in through the Serial Console Port 3-6
3-2 Creating a New User Account 3-7
3-3 Deleting a User Account 3-8
3-4 Managing Licenses 3-9
3-5 Configuring the Remote Management Interface 3-10
3-6 Accessing the CLI Using Telnet 3-11

viii Contents
3902 Service Delivery Switch Hardware Installation and Start-up Manual
009-3205-001 Standard Revision D
Copyright©2013-2015 Ciena®Corporation July 2015
3-7 Configuring an Interface using DHCP 3-12
3-8 Setting the System Host Name 3-13
3-9 Logging Out of the System 3-14
LED Overview 4-1
Unit Status LEDs 4-2
Gigabit Ethernet Port LED 4-3
10/100/1000 Mbps Ethernet Port LEDs 4-4
Technical Specifications 5-1
Regulatory Compliance 6-1
Reset Button 7-1

ix
3902 Service Delivery Switch Hardware Installation and Start-up Manual
009-3205-001 Standard Revision D
Copyright©2013-2015 Ciena®Corporation July 2015
About this Document 0
This document outlines the methodologies to be followed during the
installation of a 3902 Service Delivery Switch from Ciena Corporation.
Disclaimer While every effort has been made to ensure that this document is complete
and accurate at the time of publishing, the information that it contains is
subjecttochange.Ciena®isnot responsibleforanyadditionstoor alterations
of the original document. Networks vary widely in their configurations,
topologies, and traffic conditions. This document is intended as a general
guide only. It has not been tested for all possible applications, and it may not
be complete or accurate for some situations.
Trademark Acknowledgements
Ciena® is a registered trademark of Ciena Corporation.
Intended Audience
This document is intended for certified system installation technicians and
system administrators responsible for the installation of a 3902 Service
Delivery Switch. All 3902 installation personnel are required to read,
understand, and observe the safety precautions described in the product
manual.

xAbout this Document
3902 Service Delivery Switch Hardware Installation and Start-up Manual
009-3205-001 Standard Revision D
Copyright©2013-2015 Ciena®Corporation July 2015
Related Documentation
Additionalsupportingdocumentationis availablethroughtheCienawebsiteat
http://www.ciena.com.
The following list contains the names of the related documents in the suite:
• 39XX/51XX Product Fundamentals
•39XX/51XX Software Management and Licensing
•39XX/51XX Administration and Security
•39XX/51XX Command Reference
•39XX/51XX Configuration
• 39XX/51XX Fault and Performance
• 39XX/51XX MIB Reference
•39XX/51XX System Event Reference
•Packet Networking Glossary (009-3299-026)
•Packet Networking Transceivers Reference (009-2011-602)
Document Comments
Ciena appreciates all comments that will help us improve our documentation
quality. The user can submit comments through the Ciena website
(http://www.ciena.com).
Additional Product Information
Additional product information can be obtained by contacting the local sales
representativeorCienathroughthecontactnumbers and/ore-mailaddresses
listed on the back of the front cover.

1-1
3902 Service Delivery Switch Hardware Installation and Start-up Manual
009-3205-001 Standard Revision D
Copyright©2013-2015 Ciena®Corporation July 2015
Overview 1-
The Ciena Service Delivery Switch (SDS) product family provides Ethernet
connectivity to buildings and residences to deliver high-speed voice, video,
and data connectivity. SDS devices are designed to lower the overall cost of
building out a fiber network. These edge devices are then connected to
Service Aggregation Switch (SAS) products which aggregate and distribute
traffic to and from various points of the network. The 3902 Service Delivery
Switch is an entry-level business demarcation device in the Ciena SDS
portfolio.The3902canprovidelow-costEthernetPrivateLine(EPL),Ethernet
Virtual Private Line (EVPL), and EthernetLAN services. It can be deployed in
office, Point of Presence (POP), and Central Office (CO) locations.
The 3902 is a small and quiet unit suitable for installation in indoor
applications. It can be installed on a desktop or wall mounted using Customer
supplied hardware. The 3902 is powered by an external AC adapter. All ports,
LEDs and power connections are accessible from the front of the 3902. A full
description of the various products in the portfolio, including a full hardware
overview of the 3902, is contained in 39XX/51XX Product Fundamentals.
See Figure 1-1.
Figure 1-1
3902 Top View

1-2 Overview
3902 Service Delivery Switch Hardware Installation and Start-up Manual
009-3205-001 Standard Revision D
Copyright©2013-2015 Ciena®Corporation July 2015
The SDS units are designed to work with other products in the Ciena family to
deliver complete, integrated service offerings from a single provider or
multiple providers. The SDS devices incorporate advanced QoS capabilities,
flexibility through pluggable optics, manageability, and a small form factor unit
to present the industry’s leading fiber-to-the building solution.
Table 1-1 provides a quick overview of the interfaces available on the 3902. In
addition, the 3902 has the following physical characteristics:
• AC brick power supply — Multiple external AC power supplies are
available to accommodate deployments in different countries.
• Small clamshell form factor — Thesmall unit is suitable for desktop or wall
mount installations.
Table 1-1
3902 interface summary
Port Type Number of Ports Description
NNI 1 1GbE port with SFP connector
Supported modules are:
• 1GbE fiber modules (1000Base-X)
• 100M fiber modules (100Base-FX)
• Multi-rate 1GbE/100M fiber module (1000Base-X/
100Base-FX)
• 10/100/1000 Mbps copper SFP modules
UNI 1 10/100/1000 Mbps port with RJ-45 connector.
Console 1 Serial EIA-561 (RJ-45) port.

2-1
3902 Service Delivery Switch Hardware Installation and Start-up Manual
009-3205-001 Standard Revision D
Copyright©2013-2015 Ciena®Corporation July 2015
Installation 2-
The 3902 is designed for deployment in indoor locations and controlled
environments. It can be mounted on a desktop or on a wall.
This chapter provides installation instructions. It discusses the following
topics:
•Important Safety Information
•Installation Overview
•Mounting the 3902
•Installing the Power Supply
•Installing the SFP
•Installing the Interface Cabling
•Initial configuration
Important Safety Information
Please review the safety information before beginning the installation.
WARNING
The chassis of the 3902 should never be opened under any
circumstances. Opening the chassis will void the warranty.
The system chassis must be returned to Ciena for service or
replacement.
Power supply modules and transceivers are field-replaceable,
however, the modules or transceivers must be returned to
Ciena for service or replacement.

2-2 Installation
3902 Service Delivery Switch Hardware Installation and Start-up Manual
009-3205-001 Standard Revision D
Copyright©2013-2015 Ciena®Corporation July 2015
Installation Overview
Installation of the 3902 involves the following high level steps:
1 Mount the 3902 on the installation surface. See “Mounting the 3902” on
page 2-3 for more information.
2 Installthe power supply. See “Installing the Power Supply” on page 2-4 for
more information.
3 Install an SFP in the NNI port. See “Installing the SFP” on page 2-4 for
more information.
4 Install cabling to the ports on the faceplate. See “Installing the Interface
Cabling” on page 2-5 for more information.
You have installed the 3902.
WARNING
Do not work on the system or connect or disconnect cables
during periods of lightning activity.
WARNING
Do not stack anything on top of this unit.
WARNING
The 3902 relies on the AC power cord for the Safety Ground.
The outlet providing power to the 3902 must meet the Local
and National Safety codes.

Installation 2-3
3902 Service Delivery Switch Hardware Installation and Start-up Manual
009-3205-001 Standard Revision D
Copyright©2013-2015 Ciena®Corporation July 2015
Mounting the 3902
The 3902 can be mounted on a wall or desk top. Desktop installation simply
involves removing the unit from the packaging and placing it on the desk.
Wall mount installation is slightly more involved.The back of the 3902 unit has
keyhole slots that are used to mount the system. See Figure 2-1. When
correctly wall mounted, the faceplate of the unit will be oriented so that it is
facing downward.
Figure 2-1
3902 Bottom View
Required Tools and Accessories
To wall mount the 3902 you will need the following:
• Power drill
• Two #6 or #8 self tapping screws for drywall
• Screwdriver
For a procedure see “Mounting the 3902” on page 2-7.

2-4 Installation
3902 Service Delivery Switch Hardware Installation and Start-up Manual
009-3205-001 Standard Revision D
Copyright©2013-2015 Ciena®Corporation July 2015
Installing the Power Supply
The 3902 uses a single external brick AC power supply. The power supply is
connected using a modular jack on the right side of the faceplate labeled
5V DC. See Figure 2-2.
Note: An external surge protection device is not required.
Figure 2-2
Front view of the 3902
For a procedure see “Installing Power to the 3902” on page 2-8.
Installing the SFP
The faceplate of the 3902has a single connector which usesa pluggable SFP
optic. The SFP module provides the media-specific portion of an interface,
allowing it to support Ethernet using different media types. The SFP optic is
hot swappable. A reboot is not required after the optic is installed, the 3902
will discover the optic automatically.
Figure 2-3 shows a typical pluggable optic module and its parts. The list of
supported optics is provided in Packet Networking Transceivers Reference
(009-2011-602). Unsupported optics may not function. See “Gigabit Ethernet
Port LED” on page 4-3 for LED information.

Installation 2-5
3902 Service Delivery Switch Hardware Installation and Start-up Manual
009-3205-001 Standard Revision D
Copyright©2013-2015 Ciena®Corporation July 2015
Figure 2-3
Pluggable Optic modules
For a procedure see “Installing an SFP” on page 2-9.
Installing the Interface Cabling
The 3902 uses two different types of interface cables:
• Fiber Optic Cable — used in an optical SFP on the Gigabit Ethernet port.
• Ethernet Cable — used in a copper SFP on the Gigabit Ethernet port, in
the 10/100/1000 Mbps Ethernet port and in the Console port.
Fiber Optic Cable
The 1G SFP port on the 3902 uses a pluggable optic. Using a pluggable for
this port allows you to select the port speed, wavelength, etc. to match the
device at the terminating end. See “Installing the SFP” on page 2-4 for more
information about the transceivers, and their installation.
Most SFP ports will require optical cables. You will need to know the
specification of the optic to select the appropriate cable.
Note: Donotremove thedust coversfromthe SFPoptic andopticalcable
until immediately prior to mating the connectors.
See “Gigabit Ethernet Port LED” on page 4-3 for LED information.
For a procedure see “Installing a Fiber Optic Cable” on page 2-10.
Ethernet Cable
The following ports on the 3902 have RJ-45 jacks:
• Console Port
WARNING
All electrical connections are intended for indoor use only.
20-pin connector
Bottom of module

2-6 Installation
3902 Service Delivery Switch Hardware Installation and Start-up Manual
009-3205-001 Standard Revision D
Copyright©2013-2015 Ciena®Corporation July 2015
• 10/100/1000 Mbps Port
• 1G Port when a copper SFP is installed
To install an Ethernet cable, insert the connector into the port on the device
until you hear a clicking sound. Insert the tail end of the cable into the port on
the terminating device.
Initial configuration
Two different methods can be used to assign an IP address to the device:
• using a DHCP server to automatically assign an IP address
(recommended)
• configuring an IP address manually.
Both methods are accomplished through the CLI and are not described inthis
document. For detailed instructions, see 39XX/51XX Configuration.
Note: If the device has not been assigned an IP address (either manually
or through a DHCP server) other than the default IP address,
communication can only take place through the console port. Initial IP
configuration must be done using the console port.
CAUTION
Use caution when setting the IP address or subnet mask, the
new value takes effect immediately. If information is set that is
inconsistent with network settings, communication to the
device may no longer be possible. If all other troubleshooting
methods have been exhausted, recovery may be possible
using the Reset button.

Installation 2-7
3902 Service Delivery Switch Hardware Installation and Start-up Manual
009-3205-001 Standard Revision D
Copyright©2013-2015 Ciena®Corporation July 2015
Procedure 2-1
Mounting the 3902
Use the following procedure to mount the 3902.
Step Action
1Remove the 3902 from the packaging and inspect the unit for damage.
Note: If damage is apparent, contact Ciena Customer Support to obtain an
RMA number, and ship the damaged unit back to Ciena for repair.
2Do one of the following:
• If this is a desktop installation, place the unit on the installation surface.
The mounting portion of the installation is now complete.
• If this is a wall mount installation, proceed to step 3.
3Using customer supplied mounting screws, drill holes and install the two
screws in the mounting surface so that they are 6.9 cm (2.7 inches) center to
center. The screws should be installed so that they protrude from the
mounting surface. The distance from the mounting surface to the top of the
screw head should be 0.6 cm (0.25 inches).
4Orient the 3902 so that the faceplate is facing downward and then use the
keyhole slots on the bottom of the unit to hang the unit on the mounting
hardware.
You have mounted the 3902.

2-8 Installation
3902 Service Delivery Switch Hardware Installation and Start-up Manual
009-3205-001 Standard Revision D
Copyright©2013-2015 Ciena®Corporation July 2015
Procedure 2-2
Installing Power to the 3902
Use the following procedure to connect power to the 3902.
Step Action
1Remove the power supply from the packaging and inspect the unit for
damage.
Note: If damage is apparent, contact Ciena Customer Support to obtain an
RMA number, and ship the damaged unit back to Ciena for repair.
2Take the modular jack end of the power cable and snap the cable into the
retention clip to the right of the power jack. Approximately 1.9 cm (0.75
inches) of cable should extend from the clip.
3Plug the modular jack into the plug on the right side of the faceplate of the
3902 labeled 5V DC. See Figure 2-4.
Figure 2-4
Installing the Power Cord
4Dress the power cable as appropriate for your site.
Note: In wall mount installations it may be useful to secure the power cable
and or the power supply to the mounting surface.
5Plug the power supply into a power source.
You have installed power to the 3902. The 3902 will now turn on.
WARNING: The AC socket outlet shall be installed near the equipment and
shall be easily accessible.
Table of contents