Overview
The MET-ECOM Metreau Entry Communicator (FG2180-01-cc) can be placed at entry
points of homes, condos and hotels to provide audio communications with anyone at a
door or gate - all over IP. Any AMX Modero intercom-enabled touch panel can
interface with the Entry Communicator and allow residents to open doors, gates and
more.
Refer to the Metreau Entry Communicators Operation/Reference Guide (available
online at www.amx.com) for additional installation details and instructions on using the
Configuration Manager, using the full-duplex intercom, and NetLinx Programming
information.
Note: The MET-ECOM is suitable for installation in exterior environments.
Product Specifications
Rear Panel Components
FIG. 2 shows the location of the rear panel components for the MET-ECOM.
Wiring and Connections
Note: To avoid any damage to the electronic component, installation must be
performed in an ESD safe environment.
Note: Do not connect power to the MET-ECOM until the wiring is complete.After you
have completed the installation, consult the Using the Configuration Manager section
of the Metreau Entry Communicators Operation/Reference Guide.
FIG. 1 MET-ECOM Metreau Entry Communicator
MET-ECOM Specifications
Power: • PoE powered – no local Power Supply needed
• IEEE 802.3af Compliant
Front Panel Components: • Integrated Color Video Camera
• Speaker
• Dual Color LED Status Bar: (Yellow/ Red) can be used to
provide feedback, to attract attention for action, or as
general indicator.
• Pushbutton (Doorbell)
• Microphone
Integrated Color Video
Camera:
• QVGA 320 x 240
• Supports Motion JPEG (MJPEG) and H.263 codecs.
• Viewing Angle: 42°
Speaker: • 8 Ohm, 2W
• 80dB SPL (sound pressure level at 1 meter)
• Meets G.711 sound standard
Microphone: • -40 dB sensitivity, built-in echo cancellation
(telephone quality)
• Full duplex communication
• VoIP Telephony
Rear Panel Components: • Camera Viewing Angle Adjustment
• Ethernet Port - 10/100 Ethernet with PoE. LEDs show
communication activity, connection status, speeds, and
mode information:
SPD (speed) - Green LED lights On when the connection
speed is 100 Mbps and turns Off when the speed is 10
Mbps.
L/A (link/activity) - Orange LED lights On when the
Ethernet cables are connected and terminated correctly,
and blinks when receiving Ethernet data packets.
• ID/Reset pushbutton: Push to set the NetLinx ID (Device
only) assignment for the device. Push and hold for at least
10 seconds to reset to factory default settings.
• Status LED: Green LED provides an indication of both the
system status and communication status with the target
Master. 1 blink every 5 seconds indicates there is
currently active communication between the Metreau unit
and a target Master.
• 2 Multi-Purpose I/Os (5V): 2-channel binary I/O ports for
contact closure with each input being capable of voltage
sensing. Input format is software selectable with
interactive power sensing for IR ports.
Pushbutton (Doorbell)
Speaker
Video Camera
Microphone
Dual Color LED Status Bar (Yellow / Red)
MET-ECOM Specifications (Cont.)
Rear Panel Components
(Cont.):
• 2 Low Voltage Relays (1A contact): 2-channel single-pole
single throw relay ports with each relay being
independently controlled and supporting up to 2
independent external relay devices.
Dimensions (HWD): • 5.364” x 3.594” x 1.559”
(13.62 cm x 9.13 cm x 3.96 cm)
Weight: 0.90 lbs (0.408 kg)
Operating Environment: -22° to 140° F (-30° to 60° C)
Mounting: • The MET-ECOM is installed in several ways:
• 4 screws for hard surface mounting
• 2 expansion clips for pressure mounting
• Using the optional Surface Mount Box
Colors Available: • Black MET-ECOM-BK (FG2180-01-BK)
• White MET-ECOM-WH (FG2180-01-WH)
• Polished Brass MET-ECOM-PB (FG2180-01-PB)
• Antique Brass MET-ECOM-AB (FG2180-01-AB)
• Stainless Steel MET-ECOM-SS (FG2180-01-SS)
• Brushed Pewter MET-ECOM-BP (FG2180-01-BP)
Included Accessories: • Installation Kit (FG039-12) - includes front mount flange, 4
installation screws (#4-40 x 3.12), 2 Phoenix connectors
(female, 3.5mm) and a Ferrite clip.
Other AMX Equipment: • PS-POE-AF Power-over-Ethernet (PoE) power supply
(FG423-80)
• NXA-ENET24 Managed Ethernet Switch
(FG2178-60)
• NXA-ENET24PoE Managed Ethernet Switch, Power Over
Ethernet (FG2178-61)
• Conduit Box Assembly (FG039-12)
• CB-MET-ECOMS Surface Mount Box (FG039-14-S/B)
Certifications: • FCC Class B
•CE
• IEC60950
•RoHS
FIG. 2 Metreau Entry Communicator (rear panel)
Camera Viewing
Ethernet Connection
2 Multi-Purpose I/Os (5V)
2 Low Voltage Relays (1A Contact)
Mounting Slots
(2 on each side)
Mounting Clip
ID/Reset pushbutton
STATUS (green LED)
Angle Adjustment

For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).
8/08
©2008 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.
AMX reserves the right to alter specifications without notice at any time.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com
93-2180-01 REV: D
Ethernet 10/100 Base-T RJ-45 Wiring Configuration
The table below describes the pinouts, signals, and pairing for the Ethernet 10/100
Base-T connector and cable.
The MET-ECOM uses CAT5/CAT6 wire via the Ethernet port for PoE power.
PoE (Power Over Ethernet)
Use the PS-POE-AF Power over Ethernet Injector (FG423-80) to simplify wiring and
installation by eliminating the need for an AC outlet at each point of installation.
Note: Each MET-ECOM can be placed up to approximately 330’ (100 meters) from
PoE Injector.
• If used with a non PoE-capable Ethernet switch (such as the NXA-ENET24),
then an optional PS-POE-AF Power-over-Ethernet (PoE) power supply is
required to provide power to the MET-ECOM.
• If the MET-ECOM is used with a PoE-capable Ethernet switch (such as the
NXA-ENET24PoE), then no PoE Injectors are required.
Refer to the PS-POE-AF Installation Guide for additional details.
Input/Output (I/O) Port: Connections and Wiring
The I/O port responds to either switch closures, voltage level (high/low) changes, or
it can be used for logic-level outputs.
A contact closure between the GND and an I/O port is detected as a Push.
• When used for voltage inputs, the I/O port detects a low signal (0 - 1.5 VDC) as
a Push, and a high signal (3.5 - 5 VDC) as a Release (this IO port uses 5V logic
but can handle up to 12V without harm).
• When used for outputs, the I/O port acts as a switch to GND and is rated for
200 mA @ 5 VDC. This device can use up to 2 I/O ports (see table below).
• The PWR pin provides +5 VDC @ 200 mA.
• The GND connector is a common ground and is shared by all I/O ports (see
table below).
Connecting The Device via I/O
When connecting the I/O port, the GND on the MET-ECOM must be connected to
the ground of the I/O device, e.g., a master or any third party I/O device.
Relay Port: Connections and Wiring
You can connect up to 2 independent external relay devices to the Relay connectors
on the MET-ECOM.
• Connectors labeled A are for common; B are for output.
• Each relay is isolated and normally open.
Relay Connections
FIG. 3 shows the pin configuration on the I/O and Relay ports.
Note: Do not use the relays on this unit for "secure" applications such as door and
gate releases. For security reasons, an external relay box put in a secure location
will work better for these devices.
Ferrite Installation (Required)
The MET-ECOM comes with a Cat5 Suppression Ferrite that must be clipped around
the Ethernet cable, inside the back box (no tools required).
1. Release the latch to open the plastic enclosure.
2. Insert the Cat5 cable and close the enclosure.
Note: When positioning the Ferrite clip inside the back box, place the bottom of the
clip flat against the back inside surface of the back box, to allow sufficient room for
the MET-ECOM unit. See the Operation/Reference Guide for details.
Mounting Specifications
FIG. 5 shows the recommended cutout for the Metreau Entry Communicators Wall
Box. Use these dimensions for wall surface installations using expansion clips..
Note: Refer to the Metreau Entry Communicators Operation/Reference Guide for
additional installation details and drawings.
Positioning the Camera
The Metreau Entry Communicators feature a Camera Viewing Angle Adjustment
slider on the rear panel of the unit that allows you to adjust the viewing angle
horizontally from -15° to 15° (see FIG. 2).
The Camera Viewing Angle Adjustment slider is intended to be used at the time of
installation. It is not intended to be used for regular periodic adjustments. Once a
final installation location has been established, use the Camera Viewing Angle
Adjustment slider to set the desired camera angle, then finalize the installation.
Additional Documentation
Refer to the Metreau Entry Communicators Operation/Reference Guide (available at
www.amx.com) for additional installation/setup details, information on using the
Configuration Manager, the NetLinx module and Programming information.
Ethernet Pinouts and Signals
Pin Signals Connections Pairing Color
1 TX + 1 --------- 1 1 --------- 2 White-Orange
2 TX - 2 --------- 2 Orange
3 RX + 3 --------- 3 3 --------- 6 White-Green
4 no connection 4 --------- 4 Blue
5 no connection 5 --------- 5 White-Blue
6 RX - 6 --------- 6 Green
7 no connection 7 --------- 7 White-Brown
8 no connection 8 --------- 8 Brown
I/O Port Wiring Specifications
Pin Signal Function
15VDC PWR
2 I/O 2 Input/Output
3 I/O 1 Input/Output
4 GND Signal GND
FIG. 3 I/O and Relay connectors
2
+5V GND
1
BABA
21
Relays
I/Os
1234 1234
FIG. 4 Installing the CAT5 Suppression Ferrite
FIG. 5 Recommended Cutout for Wall Box
123
(complete)