Basic Conguration
Programming Date/Time
1. Scroll to Conguration
2. Press down to Instrument Settings
3. Press down
4. Scroll to Current Date
5. Press MOD
a. Use up/down arrows to change month
6. Press Enter
a. Use up/down arrows to change day
7. Press Enter
a. Use up/down arrows to change year
8. Press ENTER to save
9. Scroll to Current Time
10. Press MOD
a. Use up/down arrows to change hour
11. Press Enter
a. Use up/down arrows to change minutes
12. Press Enter
a. Use up/down arrows to change AM or PM
13. Press ENTER to save
14. Press RESET back to main screen
Unit must be in program mode for all settings below
(see picture to the right, jumper must be on the bottom 2 pins)
Changing Instrument/Display Tag
1. Scroll to Conguration
2. Press down to Instrument Settings
3. Press down
4. Scroll to Instrument Tag
5. Press MOD
6. Use up/down arrows to adjust each individual character as needed
7. Press ENTER to save
8. Press RESET back to main screen

2
AV-9900 HTST Recorder Controller
Changing Chart Tag
1. Press CHART key twice to Chart Conguration
2. Press down to Chart Tag
3. Press MOD
4. Use up/down arrows to adjust each individual character as needed
5. Press ENTER to save
6. Press RESET back to main screen
Changing Chart Speed (Rotation Time)
1. Press CHART key twice to Chart Conguration
2. Press down
3. Scroll to Chart Speed
4. Press MOD
5. Select 12 or 24hr (scroll for more options)
a. 12 hour required for PMO
6. Press ENTER to save
7. Press RESET back to main screen
Programming Inputs
1. ****Be Advised STLR is ALWAYS set to inputs 1&2 and CANNOT be changed****
2. Scroll to Function Set Up
3. Press down
4. Select the input you are trying to assign (make sure it is ashing and press enter or press
the soft key under the input)
5. Scroll to INPUT NUMBER
a. Verify the input matches per your model number
b. Press MOD to get a cursor
c. Use up/down arrows to change
d. Press ENTER to save
6. Repeat for each input function your recorder has
7. Press RESET back to the main screen when nished
8. Scroll to Conguration
9. Press Down
10. Scroll to Inputs
11. Press down
12. Select the input you are trying to assign (make sure it is ashing and press enter or press
the soft key under the input)
13. ****Be advised STLR is ALWAYS set to RTD and 0-350F range. DO NOT change this****
14. ****Be advised SFLR is ALWAYS set to mA input type and cannot be changed****
15. CPR and HWC can scroll to Input Type
a. Press MOD
b. Select either RTD or mA
c. Press ENTER to save

3AV-9900 HTST Recorder Controller
Programming Inputs (cont’d)
16. Scroll to Limit Low – Low end of input range (HWC, CPR, SFLR)
a. Press MOD to get cursor
b. Use up/down arrows to change value if needed
c. Press ENTER to save
17. Scroll to Limit High – High end of input range (HWC, CPR, SFLR)
a. Press MOD
b. Use up/down arrows to change value if needed
c. Press ENTER to save
18. Repeat for all Inputs
19. Press REST back to main screen
Programming Recording Pens
(Printed Chart Scales)
1. Scroll to Conguration
2. Press down
3. Scroll to Recording Pens
4. Press down to STLR INPUT/EVENT
5. Press ENTER
6. Scroll to INP Limit Zone Low (inside ring of chart)
a. Press MOD
b. Use up/down arrows to change value if needed
c. Press ENTER to save
7. Scroll to INP Limit Zone High (outside ring of chart)
a. Press MOD
b. Use up/down arrows to change value if needed
c. Press ENTER to save
8. ***For SFLR only Scroll to INP Zone High Division***
a. Must be set to 40
9. Repeat steps for all available inputs
10. Press RESET back to main screen
Programming 4-20mA Outputs
1. Scroll to Function Setup
2. Press Down
3. Select the input you are trying to assign (make sure it is ashing and press enter or press
the soft key under the input)
4. Scroll to INP Transmit to Current Output
5. Press MOD to get cursor
a. a. Use up/down arrows to change
i. i. 1 = output #1
ii. ii. 2 = output #2
b. b. Press ENTER to save

4
AV-9900 HTST Recorder Controller
Programming 4-20mA Outputs (cont’d)
6. Repeat for all available Outputs
7. Press RESET back to main screen
8. Scroll to Conguration
9. Press down
10. Scroll to Current Outputs
11. Press down
12. Select the input you are trying to assign (make sure it is ashing and press enter or press
the soft key under the input)
13. Scroll to Range Low (low end of output range)
14. Press MOD to get cursor
a. Press MOD
b. Use up/down arrows to change value if needed
c. Press ENTER to save
15. Scroll to Range High (high end of output range)
a. Press MOD
b. Use up/down arrows to change value if needed
c. Press ENTER to save
16. Repeat for each available Output
17. Press RESET back to main screen
Programming LEDs
1. Scroll to Conguration
2. Press down to LED 1
3. Scroll to LED 1 Actuator
4. Press MOD
a. Use up/down arrows to change actuator type
b. Select SFLR Alarm 1 for SFLR
c. Press ENTER to save
5. Scroll to LED 2
6. Scroll to LED 2 Actuator
7. Press MOD
a. Use up/down arrows to change actuator type
b. Select SFLR Alarm 2 for SFLR
c. Press ENTER to save
8. Repeat for LED’s 3 and 4 as needed
9. Press RESET back to main screen

5AV-9900 HTST Recorder Controller
Anderson-Negele
156 Auriesville Road
Fultonville, NY 12072
Phone 800-833-0081
Fax 518-922-8997
Tech. Support:
techservice@anderson-negele.com
Phone 800-833-0081
10041 / 1.0 / 2023-12-11 / CD / NA
Programming Relays
1. Scroll to Conguration
2. Press down to Relay 1
3. Scroll to Relay 1 Actuator
4. Press MOD
a. Use up/down arrows to change actuator type
b. Select SFLR Alarm 1 for SFLR
c. Press ENTER to save
5. Scroll to Relay 2
6. Scroll to Relay 2 Actuator
7. Press MOD
a. Use up/down arrows to change actuator type
b. Select SFLR Alarm 2 for SFLR
c. Press ENTER to save
8. Repeat for Relays 3 and 4 as needed
9. Press RESET back to main screen
10. Scroll to Function Setup
11. Press Down
12. Select SFLR
13. Scroll to SFLR ALARM1 Setpoint
14. Press MOD
a. Use up/down arrows to change value as needed
15. Press ENTER
16. Scroll to SFLR ALARM2
17. Press MOD
a. Use up/down arrows to change value as needed
18. Press ENTER
19. Press RESET back to main screen
Programming Setpoints
1. Scroll to Controller Set Up
2. Press Down
3. Select the input you are trying to assign (make sure it is ashing and press enter or press
the soft key under the input)
4. Scroll to NUM Setpoints
5. Press MOD
a. Use up/down arrows to change the number of setpoints
b. 5 setpoints maximum
6. Press ENTER to save
7. Scroll to SP1 Value
8. Press MOD
a. Use up/down arrows to change the setpoint value
b. Press ENTER to save
9. Repeat for Each Setpoint as needed
10. Press RESET back to main screen
Other manuals for AV-9900
1
Table of contents
Other ANDERSON-NEGELE Controllers manuals
Popular Controllers manuals by other brands

Niles
Niles MVC100 installation guide

Channel Vision
Channel Vision 2-Door Telephone Entry Controller P-0921 instructions

Mitsubishi Electric
Mitsubishi Electric Melsec-FX2N-232-BD user guide

HomeMatic
HomeMatic HM-LC-Sw4-DR Installation and operating manual

Bosch
Bosch Rexroth IndraDrive M Project planning manual

TOPP
TOPP ACK4 Installation and use instructions