Anedio D1 DAC User manual

D1 DAC (Digital-to-Analog
Converter) with Volume Control
Operating Manual

Anedio D1 DAC 1
Welcome
Thank you for purchasing the Anedio D1 DAC!
Anedio is founded upon the principle that the enjoyment of highest-
quality music should be available for everyone not just for the
esoteric few. Our quest is to attain the most realistic and faithful
reproduction of music enabling the listener to experience its beauty
pathos joy and delight more fully. At the same time we strive to
make our products affordable by focusing on the essentials and
using the most cost-effective technologies. The result we believe is
a unique combination of sonic excellence and superb value.
At the center of the Anedio D1 is the ES9018 Sabre Reference 32-bit
DAC from ESS Technologies. Its oversampling modulator
optimized for accurate reproduction of music excels at maintaining
superb linearity at all levels tracking fast transients and resolving
lowermost signals. You will be able to hear minute details accurate
rendition of instrumental timbres and spacial cues from
reverberations.
The D1 DAC incorporates multi-stage jitter reduction circuits to
tame jitter as far as possible well below the threshold of audibility.
As the digital signal goes through each stage the jitter level is
progressively reduced until the critical final stage which is driven by
an ultra-low jitter oscillator with 0.5 ps rms jitter. Whether you
listen to music through USB or SPDIF the multi-stage jitter
reduction is highly effective delivering consistently natural
musical and relaxed sound.
The built-in volume control allows power amplifiers to be connected
directly to the D1 DAC eliminating the preamp in the signal path
when playing from a digital source. Bypassing the preamp is one of
the most significant steps toward a higher level of transparency. To
ensure highest signal-to-noise ratios at realistic listening levels our
design uses an optimal combination of 32-bit digital attenuators and
thin-film resistor dividers.
All the performance and quality are made available at an affordable
price by using highly-efficient manufacturing technologies and by
incorporating cost-reduction measures from the very beginning of
the design process.
We hope you will experience many years of joy and pleasure in
listening to music.

2 Anedio D1 DAC
Important Safety In truction
The lightening symbol within an equilateral triangle is intended to
alert the user to the presence of un-insulated dangerous voltage
within the product’s enclosure that may constitute a risk of electric
shock.
The exclamation mark within an equilateral triangle is intended to
alert the user to important operating and maintenance instructions.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with
the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators heat
registers stoves or other apparatus (including amplifiers) that
produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-
type plug. A polarized plug has two blades with one wider than
the other. A grounding type plug has two blades and a third
grounding prong. The wide blade or the third prong are provided
for your safety. If the provided plug does not fit into your outlet
consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched
particularly at plugs convenience receptacles and the point
where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart stand tripod bracket or table specified
by the manufacturer or sold with the apparatus. When a cart is
used use caution when moving the cart/apparatus combination
to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused
for long periods of time.

Anedio D1 DAC 3
14. Refer all servicing to qualified service personnel. Servicing is
required when the apparatus has been damaged in any way such
as power-supply cord or plug is damaged liquid has been spilled
or objects have fallen into the apparatus the apparatus has been
exposed to rain or moisture does not operate normally or has
been dropped.
WARNING: To reduce the risk of fire or electric shock do not
expose this apparatus to rain or moisture. The apparatus shall
not be exposed to dripping or splashing and no objects filled
with liquids such as vases shall be placed on the apparatus.
To completely disconnect this equipment from the ac mains
disconnect the power supply cord plug from the ac receptacle.
The mains plug of the power supply cord shall remain readily
operable.

4 Anedio D1 DAC
Setting Up
Package Contents
•Model D1 DAC
•AC Power Cord
•IR Remote Control
•Extra Fuses
•User Manual
•Measurements of Each Unit
Front Panel
Rear Panel

Anedio D1 DAC 5
Placement of the D1 DAC
If you are using the D1 DAC primarily to listen to music through
loudspeakers (instead of headphones) place the DAC and the
amplifier between the two loudspeakers instead of setting it off to
one side. This keeps the lengths of interconnects and speaker
cables short for optimal sonic performance.
Remember that the ideal cable is no cable. The signal can never be
improved by going through a longer cable. As you shorten the
cable length the signal fidelity approaches that of the ideal cable.
The best practice therefore is to keep the cables as short as possible
by placing the DAC and the amplifier between the loudspeakers.
Bypassing the Preamp
If all your music sources are digital you do not need a preamp. The
built-in volume control allows power amplifiers to be connected
directly to the D1 DAC. Bypassing the preamp is one of the most
significant steps toward a higher level of transparency. To ensure
highest signal-to-noise ratios at realistic listening levels our design
uses an optimal combination of 32-bit digital attenuators and thin-
film resistor dividers.
Connecting Interconnects and Cables
Before connecting turn off the power to all the components in
your system.
Digital Inputs: The D1 DAC accepts four digital inputs all of
which are galvanically isolated for excellent immunity to ground
loop noise.
Channel 1 — USB (16 bits 44.1K 48KHz)
Channel 2 — SPDIF 75-ohm BNC
(24 bits 44.1K 48K 88.2K 96K 176.4K 192KHz)
Channel 3 — SPDIF 75-ohm RCA
(24 bits 44.1K 48K 88.2K 96K 176.4K 192KHz)
Channel 4 — Toslink Optical
(24 bits 44.1K 48K 88.2K 96KHz)
Line Output: Connect the left and right channels to a power
amplifier using a pair of RCA interconnects.

6 Anedio D1 DAC
Extravagant interconnects with exotic materials are unnecessary.
Two characteristics however are important: (a) low shield (outer
conductor) resistance; (b) robust mechanical design for reliable
electrical contact. The shorter the cable the more transparent your
system will be.
Plug-and-Play SB Interface
The D1 DAC is a plug-and-play USB device. There is no need to
install a USB driver. Simply plug the USB input of the DAC into the
USB port of a computer and you can enjoy listening to music
immediately.
Connecting Power Cord
For the lowest ground noise and hum it is highly recommended that
the power cords of all components be connected to a single point —
usually a single surge protector with multiple outlets. This keeps all
components referenced to a single point as far as it is practically
possible thus minimizing the differences in ground potentials
among the components.
Never use a 3-prong-to-2-prong adapter to fix a ground loop
problem. This will disable the safety earth ground and may
cause electric shocks.
Isolating Cable TV Ground
If you have a cable TV connected to your audio system ensure that
the cable ground is galvanically isolated from the audio ground. The
cable TV ground tied to the earth outside your home is at a
significantly different potential and can cause audible hum if it is
not isolated properly. If you suspect this is the case insert a cable
TV ground isolator inside your home just before your cable set-top
box or TV RF input.
Surge Protectors
A surge protector is strongly recommended so that the components
are protected from large power lines spikes which can occur for
instance from lightning strikes.
Power Switch
The power switch is located in the back panel. Toggle the switch to

Anedio D1 DAC 7
the “1” position to turn power on. To turn power off toggle the
switch to the “0” position.
When turning on and off your music system with a power
amplifier the power amplifier should be the last component to
be turned on and the first component to be turned off. This
prevents power on/off transients from being transmitted to
loudspeakers.
Lock/ nlock Indicator LEDs
The green LED light just above the volume display indicates that
the DAC is properly locked to the incoming data. The red LED
indicates that the DAC is unlocked due to the absence of valid data.

8 Anedio D1 DAC
U ing the D1 DAC
Remote Control
The D1 DAC works with the Sony RM-EZ4 Universal Remote which
was chosen for its ergonomic design. Its large buttons easily visible
and intelligently placed make it particularly suitable for controlling
the volume level.
Only those remote keys described in the manual are functional.
For use with the D1 DAC select the “CBL/SAT” mode.
Channel Selection
The channel can be set either by pressing the channel button on the
front panel or by pressing the channel +/- button on the remote
control.
When selected the channel number is displayed momentarily (e.g.
“C2” for Channel 2).
Volume Control
The volume level can be set either by turning the volume knob or by
pressing the volume +/- button on the remote control.
Holding down the volume +/- button will continually increase or
decrease the volume level.

Anedio D1 DAC 9
The numeric keys on the remote control can also be used to set the
volume level. Simply key in the volume level followed by the “ENT”
key.
The volume level changes in steps of 0.5 dB. The maximum level 0
dB is displayed as “99”. For example “59” on the display means
that the volume level is -20 dB from the maximum.
Safe Volume Level
At power on the volume level is limited to a safe level (“81” on the
display) in order to prevent accidental damages to loudspeakers or
headphones.
To prevent entering high volume levels accidentally the level above
“81” cannot be entered directly from the numeric keys but only by
turning the volume knob or by pressing the volume + key.
As you change the volume from “81” to “82” you will hear a relay
click. The D1 DAC uses an optimal combination of 32-bit digital
attenuators and relay-controlled thin-film resistor dividers in order
to ensure highest signal-to-noise ratios at realistic listening levels
Mute (Remote Control Only)
The sound can be muted by pressing the “MUTING” button on the
remote control. Pressing the “MUTING” button again restores the
previous volume level.
sing Another niversal Remote Control
As with most people we do not like to pile up remote controls in our
living rooms. In case you want to use another universal remote to
control the D1 DAC we’ve made it easy to do so by using a common
IR protocol that is readily recognized by most universal remote
controls. Simply follow the learning instruction for the universal
remote of your choice and you will be ready to control the D1 DAC
within minutes.

10 Anedio D1 DAC
Specification
D/A Converter IC: ESS Technology ES9018 Sabre Reference
32-bit DAC
Sample Rates: 44.1K-192KHz
Total Harmonic
Distortion + Noise:
0.0003% @ 1KHz 0dBFS
0.0003% @ 20KHz 0dBFS
Intermodulation
Distortion:
0.00015% @ 19KHz + 20KHz 0 dBFS
2nd order IMD
Signal-to-Noise Ratio: 124 dB 20Hz-20KHz BW 2 Vrms
126 dB A-weighted 2 Vrms
DAC Master Clock Jitter: 0.5 ps rms
Total Jitter at DAC
Output: Refer to “Measuring Jitter” on Anedio web site
Frequency Response: 20 Hz - 20 KHz (-0.15dB)
Phase: Non-inverting
Channel Separation: 130 dB @ 1KHz
120 dB @ 20KHz
Digital Inputs: USB SPDIF 75-ohm BNC SPDIF 75-ohm
RCA Toslink optical
Digital Input Resolution
and Sample Rate:
USB: 16 bits 44.1K 48KHz
SPDIF 75-ohm BNC: 24 bits
44.1K 48K 88.2K 96K 176.4K 192KHz
SPDIF 75-ohm RCA: 24 bits
44.1K 48K 88.2K 96K 176.4K 192KHz
Tosllink Optical: 24 bits
44.1K 48K 88.2K 96KHz
USB Operating System
Requirement: Windows 7 Vista XP. Apple Mac OS X
Digital Volume Control
Steps: 0.5 dB
Volume Matching
between Channels: Better than 0.1 dB
Line Output: Single-ended RCA jacks with gold-plated
contacts and teflon dielectric
Line Output Level: 2.0 Vrms (unbalanced)
Line Output Impedance: 75 ohms
Line Output Offset: 5 mV max

Anedio D1 DAC 11
Headphone Amp Current
Output: 250 mA peak
Headphone Amp Output
Impedance: 0.25 ohm 20-20KHz
Headphone Amp THD+N: 0.0004% 2Vrms into 60 ohms
Headphone Jack: 1/4” TRS
Power Consumption: 8 W
Dimensions (W x H x D): 9.0 x 3.4 x 13.0 inches (229 x 86 x 330 mm)
Weight: 8 lbs (3.6 Kg)
FCC Compliance
This equipment has been tested by MET Laboratories Inc. and
found to comply with the requirements of Title 47 of the Code of
Federal Regulations (CFR) Part 15 Subpart B for a Class B Digital
Device.

12 Anedio D1 DAC
Trouble Shooting
Symptoms Remedy
No power •Ensure the power cord is plugged in fully.
•Check the fuse. If blown ensure that the
outputs are not shorted. Replace it only with
0.2A/250V 5x20mm Time-lag (slow-blo).
Using an incorrect fuse will void the warranty.
Power on but no
sound
•Ensure that the correct channel is selected.
•Ensure that the source component is turned
on.
•Ensure that the D1 DAC is not muted
indicated by “0” on the volume display.
•Ensure that the power amplifier is turned on.
•Ensure that the interconnects and cables are
plugged in fully and seated properly.
•If the above steps do not solve the problem
recycle power by turning off the D1 DAC
waiting 10 seconds and turning it back on.
No sound through
USB (Ch 1)
•In your media player ensure that “USB Audio
DAC” is selected as the device for playback.
Hum •Ensure that all components are connected to a
single power strip.
•If there is a cable TV or antenna connection
ensure that the cable/antenna grounds are
galvanically isolated from the audio ground.
This may require inserting a ground isolator.
Diffused stereo
imaging
•Ensure that the loudspeaker phase is not
inverted.
If the problem persists please contact Anedio via the Contact page
at www.anedio.com.
WARNING: Repairs are to be performed by qualified service
personnel only. To reduce the risk of electric shock do not perform
any servicing other than that contained in the operating
instructions.

Anedio D1 DAC 13
Warranty & Repair
One-Year Limited Warranty
Anedio warrants this product to be free from defects in materials
and workmanship subject to the terms set forth below for periods
up to one year from the date of original purchase. The warranty
includes parts and labor.
Anedio will remedy the problem by repair or replacement as we
deem necessary to restore the product to full performance. Anedio
will pay the shipping cost one way (the return portion).
This warranty does not cover cosmetic damage or damage due to
accident misuse abuse negligence while in the possession of the
customer.
Tampering by persons other than factory-authorized service
personnel or failure to fully comply with the operating instructions
specified in the manual will void the warranty. Any unauthorized
disassembly component replacement or modifications performed
to the product will void the warranty.
The warranty is transferable from the original owner to a
subsequent owner as long as a copy of the bill-of-sale from Anedio
accompanies the re-sale.
Repair
In the event of a defect or malfunction contact Anedio for return
authorization (via the Contact page at www.anedio.com).
Unauthorized returns will not be accepted.
Products must be returned using original packaging material only.
Anedio is not responsible for damages incurred during transit if the
original factory packaging is not used. The packaging material may
be purchased from Anedio if necessary.
This manual suits for next models
1
Table of contents
Other Anedio Media Converter manuals
Popular Media Converter manuals by other brands

Sure Power
Sure Power 71030i installation instructions

Littfinski Daten Technik
Littfinski Daten Technik LS-DEC-BR-F operating instructions

Siemens
Siemens simovert masterdrives operating instructions

Intellisystem
Intellisystem IT-PMC-1100 P2 manual

ADF Web
ADF Web HD67865-IP-A1-2A user manual

Avtron
Avtron SMARTSafe XR67 instructions