Aneng M118A User manual

Automatic
Scanning
Digital
Multimeter
User’
Manual

—.
Overview
This
series
multimeter
is
a
pocket
3
5/6
bit
true
effective
value
automatic
scanning
digital
meter.
Depending
on
the
input
voltage/current/resistance/equal
signal,
the
instrument
is
capable
of
automatic
identification
measurement.
The
series
of
instruments
have
the
characteristics
of
stable
performance,
high
precision
and
clear
reading.
With
the
extra
convenience
of
flashlight
and
non-contact
voltage
test,
it
is
an
ideal
instrument
for
factory,
teaching
and
electronics
enthusiasts.
—.
Security
matters
Design
of
the
series
of
meters
in
accordance
with
the
1EC1010
provisions
(safety
standards
issued
by
the
International
Electrotechnical
Commission),
please
read
the
safety
precautions
carefully
before
use
the
meter,
the
use
of
strict
compliance
with
safety
regulations,
so
as
not
to
Cause
casualties
or
instrument
damage.
1,
When
measuring
the
voltage,
do
not
input
the
limit
voltage
exceeding
the
effective
value
DC
600
V
or
AC
600V;
2,
The
voltage
below
36
V
is
safe
voltage,
when
measuring
the
voltage
above
36
V,
please
be
sure
to
pay
attention
to
safety.
Because
more
than
36
V
of
voltage
may
cause
damage
to
the
human
body;
3,
When
changing
function
and
range,
the
pen
should
leave
the
test
point;
4,
Select
the
correct
function
and
range,
beware
of
wrong
operation,
although
the
series
of
instruments
with
full
range
protection
function,
but
for
the
sake
of
safety,
please
pay
more
attention
to
safety;
A
sar,
5,
OF
BA
safety
symbol
states
“hazardous
voltage
exists
","
ground
“,”
double
insulation
,“"
operator
must
refer
to
instruction
,""
low
voltage
symbol.
mo

=,
Characteristics
1.
General
characteristics
1-1.
Display
mode:
LCD;
1-2.
Maximum
display
:5999(3
5/6
bit
automatic
display);
1-3.
How
to
measure:
conversion
A/D
double
integral
fraction;
1-4.
Sampling
rate:
about
3
times
per
second;
1-5.
Excess
range
display:
display
"OL";"
1-6.
Low
voltage
display
:""
symbol
appears;
*~
1-7.
Working
environment
:(0~40)‘C,
relative
humidity
<80%;
1-8.
Electricity:
Two
batteries
7(AAA
2*1.5V);
1-9.
Volume
size:118*68*30mm
1-10,
Weight:100g
without
battery
2.
Technical
characteristics
Accuracy
:=
(reading
a%+
minimum
effective
digit),
guaranteed
accuracy
environment:
temperature
(23
+5)
C,
relative
humidity
<75%,
calibration
guarantee
date
one
year.
2-2,
performance
("A"
means
the
table
has
this
function)
ee
ce
DC
Current
a
ae
ac
es
a
AZ
Resistance/Diode,
ey
A
Capacitance
NCV
Zero
line/fire
line
test
Backlight
manual/automatic
shutdown
Ac
Validity
Measurement
Flashlight
lighting

3-1,
DC/AC
voltage
measurement
(DCV/ACV)
+(0.5%+3)
0.01V
Input
impedance
:10
M
©
;
Overload
protection
:600
V
dc
or
600
V
ac
peak.
3-2
Resistance
Measurement
(2)
penis,
+
(2.5%+3)
10k
Q
Input
impedance
:10
M
©
;Overload
protection
:600
V
dc
or
600
V
ac
peak.
3-3
Diode/on-off
test
Display
value
Test
conditions
Forward
DC
current
Diode
forward
about
imA
pressure
drop
open
circuit
voltage
V
about
3
The
buzzer
sounds
long
and
the
two-point
About
0.4
V
open
resistance
is
less
than
circuit
voltage
(S0+202.
Input
impedance
:10
M
&
;
Overioad
protection
:600
V
dc
or
600
V
ac
peak.
3-4
Measurement
of
capacitance
(C)(JS33D
models
only)
Overload
protection
:600
V
DC
or
600
V
AC
peak.

3-5,
AC/pc
current
(DC/AC
A)
Maximum
measured
pressure
drop
:600
mV;
Overload
protection
:10
A
+
(2%430)
PU,
Operation
Key
Description
N
1.
Flashlight
trigger
button;
2.
NCV
measurement
key,
long
press
NCV
key
can
measure
electric
field
induction
signal;
3.
H/BL
for
reading
hold
key,
long
press
2
seconds
to
light
LCD
screen
backlight,
about
15
seconds
after
the
backlight
automatically
turned
off;
4.
Power
button,
long
press
2
seconds
to
turn
on/off
the
power
supply,
boot
state
this
key
for
the
function
selection
button,
each
light
press
switch
once
measurement
function;
HSL
GY
Fi.
Operational
guidance
5-1,
DC/AC
voltage
automatic
scan
test
(DCV/ACV)
1.Press
the
power
key
for
more
than
2
seconds
to
turn
on
the
meter.
The
boot
is
shown
as
automatic
scan
AUTO".
2.
insert
black
watch
pen
into
"COM"
jack,
red
watch
pen
insert"
V/
2"
jack,
test
watch
pen
reliable
contact
test
point.
3.
when
the
voltage
between
the
input
port
"COM"
and"
V/
Q
"
is
greater
than
0.5
V,
the
meter
will
compare
according
to
the
size
of
the
DC
component
and
AC
component,
take
its
larger
component
signal,
and
then
automatically
switch
the
range
according
to
the
size
of
the
measured
value,
and
then
display
the
measured
value
on
the
LCD.
4.
If
it
can
not
be
measured
in
the
environment
of
greater
interference,
trigger
the
power
key
to
manually
select
DC
or
AC
voltage
measurement
mode
for
measurement.
Note:
1,
The
input
voltage
must
not
exceed
the
DC
600
V
or
AC
600
V,
if
there
is
a
risk
of
damage
to
the
instrument
circuit;
when
measuring
more
than
36
V
voltage
should
pay
special
attention
to
safety
to
avoid
the
danger
caused
by
electric
shock;
2.
After
completing
all
measurement
operations,
disconnect
the
meter
pen
from
the
circuit
under
test.
5-2,
Resistance
measurement
1.
Press
the
power
key
for
more
than
2
seconds
to
turn
on
the
meter.
boot
auto
scan
status
“AUTO"..

2.
Insert
black
watch
pen
into
"COM"
jack,
red
watch
pen
insert"
V/
0"
jack,
test
watch
Pen
reliable
contact
test
point,
3.
If
the
measuring
resistance
at
both
ends
of
the
meter
pen
is
less
than
50
,
the
burzer
will
make
a
continuous
noise
and
requires
a
fast
buzzer
measurement,
press
the
power
key
to
manually
select
the
buzzer
fast
measurement
function.
4.
If
the
resistance
of
the
closed
loop
is
measured,
the
two
ends
of
the
measured
resistance
must
be
treated
for
discharge,
otherwise
if
the
voltage
in
the
loop
is
greater
than
0.6
V,
the
instrument
will
be
mistaken
for
the
voltage
measurement
and
enter
the
voltage
measurement
mode.
5.
the
resistance
between
the
red
and
black
meter
pen
is
greater
than
50
2,
the
meter
will
automatically
switch
the
range
according
to
the
actual
resistance
measurement
value,
and
then
the
measured
value
will
be
displayed
in
the
LCD.
Note:
1,
When
measuring
low
resistance,
in
order
to
obtain
accurate
reading,
you
can
first
record
the
meter
pen
short
circuit
value,
subtract
the
meter
in
the
measurement
reading
The
value
of
the
pen
in
short
circuit;
2,
When
measuring
the
on-line
resistance,
all
the
power
supply
of
the
circuit
must
be
turned
off
and
all
the
capacitors
are
discharged
to
ensure
the
accuracy
of
the
measured
value.
5-3,
diode
measurements
1.
Press
the
power
key
for
more
than
2
seconds
to
turn
on
the
meter.
boot
display
as
automatic
scan
state
"AUTO",
press
power
key
to
manually
select
diode
measurement
function.
2.
Insert
black
watch
pen
into
"COM"
jack,
red
watch
pen
insert"
V/
©"
jack,
test
watch
pen
reliable
contact
test
point.
3.
meter
will
show
the
positive
pressure
drop
of
the
measured
diode
on
the
LCD.
If
the
polarity
of
the
two
ends
of
the
diode
in
contact
with
the
pen
is
reversed
or
the
diode
is
open,
the
LCD
of
the
meter
will
show
“OL"."
5-4,
capacitance
measurements
1.
Press
the
power
key
for
more
than
2
seconds
to
turn
on
the
meter.
,
boot
display
as
automatic
scan
state
"AUTO",
press
power
key
manually
switch
to
capacitance
measurement
function.
2.
Insert
black
watch
pen
into
"COM"
jack,
red
watch
pen
insert”
V/
©"
jack,
test
watch
pen
reliable
contact
test
point.
3.
Meter
will
automatically
switch
the
range
according
to
the
capacitance
value
between
the
red
and
black
meters,
and
the
specific
value
of
the
measured
capacitance
will
be
displayed
on
the
LCD.
The
measuring
range
of
the
capacitance
is
10
nF/100nF/1uF/10uF/100uF/1mF/10mF/60mF..
Note:
1.
Please
treat
the
measured
capacitance
to
discharge
fully
before
measuring
the
Capacitance,
otherwise
it
will
enter
the
voltage
measurement
mode.
2.
When
measuring
capacitance
with
10
nF
gear,
the
LCD
display
value
may
have

residual
reading,
the
distributed
capacitance
of
this
digital
meter
pen,
the
bit
accurate
reading
can
subtract
this
value
after
measurement.
3.
A
LCD
will
show
some
values
and
instability
when
measuring
serious
leakage
or
breakdown
capacitance
at
large
capacitance
files;
when
measuring
large
capacitance,
the
reading
takes
a
few
seconds
to
stabilize,
which
is
normal
when
measuring
large
capacitance.
4.
Unit
1
F=1000
mF
lmFF=1000
uF
uF=1000nF
nF=1000
pF
5-5,
Current
Test
Function
(DC/AC
A)
1.Press
the
power
key
for
more
than
2
seconds
to
turn
on
the
meter.
The
boot
is
shown
as
automatic
scan
AUTO".
2.
Insert
black
watch
pen
into
"COM"
jack,
red
watch
pen
insert
"10
A"
jack,
test
watch
pen
reliable
contact
test
point.
3.
Input
current
greater
than
20
mA
between
the
input
port
"COM"
and
"10
A",
the
meter
will
display
the
current
value
with
large
de-component
on the
LCD
according
to
the
magnitude
of
the
AC
/
DC
component.
Note:
1,
Before
the
instrument
is
connected
in
series
to
the
circuit
to
be
tested,
the
power
in
the
circuit
should
be
turned
off
first;
2,
Maximum
input
current
is
10
A(
depending
on
the
red
meter
pen
insertion
position),
too
much
current
will
burn
out
the
internal
fuse,
be
careful,
each
measurement
time
must
not
be
more
than
10
seconds,
too
much
current
or
too
long
measurement
time
will
make
the
instrument
circuit
heating,
or
even
damage
the
instrument;
3.
Do
not
connect
the
meter
pen
test
pin
parallel
to
any
circuit
when
the
red
meter
pen
is
inserted
in
the
"10
A"
port,
this
will
damage
the
fuse
and
meter.
4.
After
all
the
measurement
operations
are
completed,
the
power
supply
should
be
turned
off
first
and
then
the
connection
between
the
meter
pen
and
the
measured
circuit
should
be
disconnected.
5.
No
more
than
36V
DC
or
25V
AC
voltage
is
entered
between
port
10
and
port
COM".
5-6,
NCV
measurements
1.
Press
the
power
key
for
more
than
2
seconds
to
turn
on
the
meter.
Press
‘NCV’
key
to
enter
EF
measurement,Keep
pressing
the
key
.
2.
Instrument
has
the
NCV
test
induction
end,
the
induction
end
is
close
to
the
AC
voltage
side,
according
to
the
signal
intensity,
the
buzzer
will
make
a
continuous
sound
of
different
frequencies,
at
the
same
time,
the
LCD
will
still
display
different
segments
according
to
the
signal
strength,
VI.
Automatic
Switching
Machine
The
instrument
has
the
function
of
automatic
shutdown,
when
the
instrument
stops
using
for
15
minutes,
the
instrument
will
automatically
power
off
into
the
dormant
state;
to
restart
the
power
supply,
hold
down
the
power
key
more
than
2
seconds,
wake
up
the
instrument
into
the
automatic
scanning
measurement
state,
the
LCD
shows
“AUTO"."
If
you
want
to
cancel
the

automatic
shutdown
function,
press
"HOLD"
key
and
power
key
simultaneously
to
wake
up
the
instrument
in
the
instrument
dormant
state,
at
this
time
the
automatic
shutdown
function
of
the
instrument
will
be
cancelled.
,