Anigmo AE-2400R User manual

Touchless switch
Touchless switch with 10Arelay output
Model AE-2400 R
CAUTION:
Important notes
Read and understand these instructions before
installing device. Before installing this unit,
disconnect power at circuit breaker or remove fuse
to avoid shock or damage to the unit. This
device is intended for installation with local
regulations. It is recommended that a qualified
electrician perform this operation
Do not install in combination with standard 3-Way
switches or third party remote (slave) unit.
Use only in combination with Anigmo AE-S
remote (slave)unit.
Installation of this switch in proximity of strong EM
interference such as (and not limited to) electrical
welding machines, inadequately shielded power
supplies, radars etc. could cause inadverted
switch activity.
This switch may not be used in any application in
which the inadvertently changing the switch state
could create a situation where personal injury, death
or property damage may occur.
This unit requires a neutral connection
Do not exceed maximal rated current of the unit
1.
2.
3.
4.
5.
6.
Warranty
All products sold or distributed by Anigmo or any of
its subsidiaries are guaranteed to be free from defects
in materials and workmanship for the period of 5 years.
This warranty shall extend to the original end
purchaser only. Anigmo, at its option, shall repair or
replace any Anigmo product within the Terms of
Warranty expressed herein, which fails to meet the
product's specifications.
This warranty does not extend to product failures or
defects caused by, or associated with, but not limited
to; failure to install or maintain correctly, unsuitable
physical or operating environment, accident, force
majeure, hazard, misuse, electrical supply,
unauthorised repair, modification or alteration.
Anigmo will not accept any liability or responsibility
under the terms of warranty expressed herein for,
but not limited to; negligence, loss of profit or data or
damages either material or personal. Mandatory
liability shall be restricted to the sum equal to the
purchase of the product.
This product may be protected by following patents
US 7.531.921, EP 2.038.906, US20090284182,
US 8.339.062, EP 2.292.078
Contact
ANIGMO
Anigmoteh d.o.o.
Tehnoloski park 21
1000 Ljubjana
Slovenia, Europe
www.anigmo.com
email: [email protected]
INSTALLATION
1. WARNING: Turn power OFF at circuit breaker
or remuve the fuse
2. Connect wires as shown. Refer to wiring
diagrams.
3. Before installing the unit into a wallbox, set the
desired sensor range if needed.
NOTE: The unit is supplied with its sensing range
set to maximum ( about 10 cm).
4. Mount the unit into wallbox using claws.
Align before tightening the claw screws
5. Attach decorativeswitchplate. Allign magnets on the
back of the switchplate with magnets on the unit
and push.
L
N
LOAD
wallbox
AE-2400 R
NLS
L
N
LOAD
wallbox
AE-2400 R
NLS
wallbox
AE-S
L
S
wallbox
AE-S
L
S
MULTI LOCATION CONTROL(multiple switches controlling one load)
SINGLE LOCATION CONTROL (one switch controlling one load)
6. Restore power at the circuit breaker
WIRING DIAGRAM
Load rating:
240V AC / 50Hz
10A max
F
F*
*
*Connect only to mains
protected with
fuse rated 10A or less.
LOAD
HOT
NEUTRAL
If mounting with screws, first remove both claws,
complete with nuts and screws. Fix the unit
with provided screws only.
AE-2400R can switch various loads, including Incandescent, Halogen, Low voltage Halogen, LED, CFL and linear flourescent lamps.
When AE-2400R is connected and powered up, the lights can be turned on by moving the hand in front of the switch plate. When the hand enters the switch sensing
range, the lights will turn on. The hand should then move out of the sensor range. When the hand enters the switch sensing range again, the lights will turn off
Each time the hand enters the sensing range, the switch will change its on/off state. If the hand remains inside of the switch sensing range, no switch state change will
occur.
Switch plate can be removed and replaced at anytime, without first switching the power off at the fuse. But when removing the switch plate please note, that the switch will
enter the calibration cycle whenever the switch plate is removed, attached or moved. The cycle will last for about 1-2 minutes during which the switch will be
unresponsive.
NOTE: When the power is supplied to the switch, its state will always be in “off” position, regardless of its state when it was powered down.
Whenever the hand enters the
sensing range in front of the
switchplate light turns on/off
Moving the hand while staying in
sensing range doesn’t have any
effect on the switch operation. To
turn the switch on/off, the hand
must first LEAVE the sensing
range.
SYMPTOM
The light doesn’t turn on
The switch doesn’t react to hand
movement
Switch operation is inconsistent
(it doesn’t react consistently to the
hand movements)
Difficult to switch the lights on
AE-2400R TOUCHLESS SWITCH OPERATIONAL MANUAL
Turn the lights on and off:
Troubleshooting
Note: Touchless switch with attached switchplate is depicted in above examples. The switch mechanism is visible in the images for clarity, but with typical installation it
would be hidden inside the wallbox and only the switchplate would be visible on the wall surface.
POSSIBLE CAUSE
Faulty wiring
Faulty light bulb
Switch entered the calibration mode
Close proximity of moving objects
Unshielded or poorly shielded
transformers or power supplies near
the switch, switch wiring or as a
switch load.
Connected light has a dead time
before switching on
SOLUTION
Check if the switch is connected according to the connection diagram.
Checkif the fuse is turned on after connecting
Check the lightbulb and replace if necessary.
If the switchplate is exchanged, moved, removed or re-attached, the switch
automatically enters the calibration mode, during which it does not react on any
hand movement.
Wait for approx. 1-2 minutes for the dimmer to complete the cycle.
Switch sensor reacts to any moving object in the sensing range that is large
enough. Check if any object close to the sensor can move into or close to the
sensor range (such as: curtains, hanging wires, ropes or wall decoration).
Check if the switch plate is securely fixed. Moving switch plate even slightly can
cause unreliable switch operation.
Poorly shielded transformers, drivers and power supplies can cause excessive
EMI (electromagnetic interference), that can cause unreliable switch operation.
Use only certified and properly shielded power supples.
Reduce sensing range to decrease sensibility
Some light sources, especially flourescent lights have a significant delay between
the moment the power is applied to them and the moment the light turns on. This
delay can be several seconds in length. Due to this delay, no light will be emitted
from the light source at the moment the user turns the switch on.
User unfamiliar with this behaviour could falsely think that the switch didn’t react to
their “on” command and try to activate the switch again. But this second motion
would in fact turn the switch off.
To resolve this, turn the switch on and wait for couple of seconds. Listen to discrete
click sound from inside of the switch, indicating the switch has actually turned on.
Alternatively, use the switch version with sound feedback option.

Other Anigmo Switch manuals

Anigmo AE-2400RM User manual

Anigmo

Anigmo AE-2400RM User manual

Anigmo AE-2400-RC User manual

Anigmo

Anigmo AE-2400-RC User manual

Anigmo AE-2400-LED User manual

Anigmo

Anigmo AE-2400-LED User manual

Popular Switch manuals by other brands

hager TS 204B User instructions

hager

hager TS 204B User instructions

Eaton Crouse-hinds series operating instructions

Eaton

Eaton Crouse-hinds series operating instructions

D-Link DU-H4 user manual

D-Link

D-Link DU-H4 user manual

LevelOne IES-0840 user manual

LevelOne

LevelOne IES-0840 user manual

Razer Base Station Chroma Master guide

Razer

Razer Base Station Chroma Master guide

Kramer VS-21DTP quick start guide

Kramer

Kramer VS-21DTP quick start guide

Aqara T1 quick start guide

Aqara

Aqara T1 quick start guide

odot ODOT-MS105T user manual

odot

odot ODOT-MS105T user manual

Duxbury Networking DUX106G installation guide

Duxbury Networking

Duxbury Networking DUX106G installation guide

NETGEAR FSM726v3 - ProSafe Fast Ethernet L2 Managed... install guide

NETGEAR

NETGEAR FSM726v3 - ProSafe Fast Ethernet L2 Managed... install guide

TRENDnet TK-1603R Quick installation guide

TRENDnet

TRENDnet TK-1603R Quick installation guide

SMC Networks EX600-WD Series Operation manual

SMC Networks

SMC Networks EX600-WD Series Operation manual

Lantronix SM24TBT2DPA Web user guide

Lantronix

Lantronix SM24TBT2DPA Web user guide

Kemo M122 manual

Kemo

Kemo M122 manual

Kathrein EXE 1512 manual

Kathrein

Kathrein EXE 1512 manual

König Electronic CMP-EHUB43 manual

König Electronic

König Electronic CMP-EHUB43 manual

UTICOR Touch PRLS Getting started

UTICOR

UTICOR Touch PRLS Getting started

Seller MA-3116 user manual

Seller

Seller MA-3116 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.