Anigmo AE-2400RM User manual

Touchless switch
Touchless switch with 10Arelay output
Models: AE-2400 R, AE-2400RM, AE-S
CAUTION:
Important notes
1.
2.
3.
4.
5.
6.
Warranty
All products sold or distributed by Anigmo or any of
its subsidiaries are guaranteed to be free from defects
in materials and workmanship for the period of 5 years.
This warranty shall extend to the original end
purchaser only. Anigmo, at its option, shall repair or
replace any Anigmo product within the Terms of
Warranty expressed herein, which fails to meet the
product's specifications.
This warranty does not extend to product failures or
defects caused by, or associated with, but not limited
to; failure to install or maintain correctly, unsuitable
physical or operating environment, accident, force
majeure, hazard, misuse, electrical supply,
unauthorised repair, modification or alteration.
Anigmo will not accept any liability or responsibility
under the terms of warranty expressed herein for,
but not limited to; negligence, loss of profit or data or
damages either material or personal. Mandatory
liability shall be restricted to the sum equal to the
purchase of the product.
This product may be protected by following patents
US 7.531.921, EP 2.038.906, US20090284182,
US 8.339.062, EP 2.292.078
Contact
ANIGMO
Anigmoteh d.o.o.
Tehnoloski park 21
1000 Ljubjana
Slovenia, Europe
www.anigmo.com
email: [email protected]
INSTALLATION
1. WARNING: Turn power OFF at circuit breaker
or remove the fuse
2. Connect wires as shown. Refer to wiring
diagrams.
3. Before installing the unit into a wall box, set the
desired sensor range if needed.
NOTE: The unit is supplied with its sensing range
set to maximum ( about 10 cm).
4. Mount the unit into wall box using claws.
Align before tightening the claw screws
5. Attach decorative switchplate. Align magnets on the
back of the switchplate with magnets on the unit
and push.
L
N
LOAD
wallbox
AE-2400 R
NLS
L
N
LOAD
wallbox
AE-2400 R
NLS
wallbox
AE-S
L
S
wallbox
AE-S
L
S
MULTI LOCATION CONTROL(multiple switches controlling one load)
SINGLE LOCATION CONTROL (one switch controlling one load)
6. Restore power at the circuit breaker
WIRING DIAGRAM
Load rating:
240V AC / 50Hz
10A max
F
F*
*
*Connect only to mains
protected with
fuse rated 10A or less.
LOAD
HOT
NEUTRAL
If mounting with screws, first remove both claws,
complete with nuts and screws. Fix the unit
with provided screws only.
Read and understand these instructions before
installing the device. Before installing this unit,
disconnect power at the circuit breaker or remove
fuse to avoid shock or damage to the unit. This
device is intended for installation with local
regulations. It is recommended that a qualified
electrician perform this operation
Do not install in combination with standard 3-Way
switches or third-party remote (slave) unit.
Use only in combination with Anigmo AE-S
remote (slave)unit.
Installation of this switch in the proximity of strong
EM interference such as (and not limited to)
electrical welding machines, inadequately shielded
power supplies, radars, etc. could cause inadvertent
switch activity.
This switch may not be used in any application in
which the inadvertently changing the switch state
could create a situation where personal injury, death
or property damage may occur.
This unit requires a neutral connection
Do not exceed the maximal rated current of the unit
AE-2400R can switch various loads, including Incandescent, Halogen, Low voltage Halogen, LED, CFL, and linear fluorescent lamps. When AE-2400R is connected
and powered up, the lights can be turned on by moving the hand in front of the switch plate. When the hand enters the switch sensing range, the lights will turn on.
The hand should then move out of the sensor range. When the hand enters the switch sensing range again, the lights will turn off. Each time the hand enters
the sensing range, the switch will change it's on/off state. If the hand remains inside of the switch sensing range, no switch state change will occur.
The switch plate can be removed and replaced at any time, without first switching the power off at the fuse. But when removing the switch plate please note, that the switch
will enter the calibration cycle whenever the switch plate is removed, attached, or moved. The cycle will last for about 1-2 minutes during which
the switch will be unresponsive.
NOTE: When the power is supplied to the switch, its state will always be in the “off” position, regardless of its state when it was powered down.
Whenever the hand enters the
sensing range in front of the
switchplate light turns on/off
Moving the hand while staying in
sensing range doesn’t have any
effect on the switch operation. To
turn the switch on/off, the hand
must first LEAVE the sensing
range.
SYMPTOM
The light doesn’t turn on
The switch doesn’t react to hand
movement
Switch operation is inconsistent
(it doesn’t react consistently to the
hand movements)
Difficult to switch the lights on
AE-2400R TOUCHLESS SWITCH OPERATIONAL MANUAL
Turn the lights on and off:
Troubleshooting
Note: A touchless switch with an attached switchplate is depicted in the above examples. The switch mechanism is visible in the images for clarity but with typical
installation it would be hidden inside the wall box and only the switchplate would be visible on the wall surface.
POSSIBLE CAUSE
Faulty wiring
Faulty light bulb
Switch entered the calibration mode
Close proximity of moving objects
Unshielded or poorly shielded
transformers or power supplies near
the switch, switch wiring or as a
switch load.
Connected light has a dead time
before switching on
SOLUTION
Check if the switch is connected according to the connection diagram.
Check if the fuse is turned on after connecting
Check the lightbulb and replace it if necessary.
If the switchplate is exchanged, moved, removed, or re-attached, the switch
automatically enters the calibration mode, during which it does not react to any hand
movement. Wait for approx. 1-2 minutes for the dimmer to complete the cycle.
Switch sensor reacts to any moving object in the sensing range that is large enough.
Check if any object close to the sensor can move into or close to the sensor range
(such as curtains, hanging wires, ropes, or wall decoration).
Check if the switch plate is securely fixed. Moving the switch plate even slightly can
cause unreliable switch operation.
Poorly shielded transformers, drivers, and power supplies can cause excessive
EMI (electromagnetic interference), that can cause unreliable switch operation. Use
only certified and properly shielded power supplies.
Reduce sensing range to decrease sensibility
Some light sources, especially fluorescent lights have a significant delay between
the moment the power is applied to them and the moment the light turns on. This
delay can be several seconds in length. Due to this delay, no light will be emitted
from the light source at the moment the user turns the switch on. A user unfamiliar
with this behaviour could falsely think that the switch didn’t react to their “on”
command and try to activate the switch again. But this second motion would in fact
turn the switch off. To resolve this, turn the switch on and wait for a couple of
seconds. Listen to discrete click sound from inside of the switch, indicating the
switch has actually turned on.
Alternatively, use the switch version with the sound feedback option.

This manual suits for next models

2

Other Anigmo Switch manuals

Anigmo AE-2400-LED User manual

Anigmo

Anigmo AE-2400-LED User manual

Anigmo AE-2400R User manual

Anigmo

Anigmo AE-2400R User manual

Anigmo AE-2400-RC User manual

Anigmo

Anigmo AE-2400-RC User manual

Popular Switch manuals by other brands

Icron Icron WiRanger user guide

Icron

Icron Icron WiRanger user guide

Matrix Switch Corporation MSC-TXD44L product manual

Matrix Switch Corporation

Matrix Switch Corporation MSC-TXD44L product manual

H3C S9820-8C-SAN installation guide

H3C

H3C S9820-8C-SAN installation guide

Simon 7500316-039 manual

Simon

Simon 7500316-039 manual

Belkin OMNIVIEW P74696 user manual

Belkin

Belkin OMNIVIEW P74696 user manual

Niveo NGSME24G4S user manual

Niveo

Niveo NGSME24G4S user manual

Intellitronix N3210 Installation guides

Intellitronix

Intellitronix N3210 Installation guides

Lucent Technologies LambdaUnite installation guide

Lucent Technologies

Lucent Technologies LambdaUnite installation guide

TRENDnet TK-1602R Specifications

TRENDnet

TRENDnet TK-1602R Specifications

ATEN KVMP CS1822 user manual

ATEN

ATEN KVMP CS1822 user manual

IFM AL3100 operating instructions

IFM

IFM AL3100 operating instructions

Cisco MGX 8950 Product overview

Cisco

Cisco MGX 8950 Product overview

SimPal SimPal-T40 user manual

SimPal

SimPal SimPal-T40 user manual

RGBlink VSP 1314 user manual

RGBlink

RGBlink VSP 1314 user manual

StarTech.com 5G7AINDRM-USB-A-HUB quick start guide

StarTech.com

StarTech.com 5G7AINDRM-USB-A-HUB quick start guide

Matrix Switch Corporation MSC-2HD1632L product manual

Matrix Switch Corporation

Matrix Switch Corporation MSC-2HD1632L product manual

Ubiquiti ES-48-500W quick start guide

Ubiquiti

Ubiquiti ES-48-500W quick start guide

Digium R800 Administrator's manual

Digium

Digium R800 Administrator's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.