Anjon Monsoon Series User manual

Anjon Manufacturing
1000 Liberty Industrial Drive
O’Fallon, MO 63366
1-800-553-5605
www.anjonmfg.com
Monsoon Series
Pond Pump
Owner Manual

Anjon Monsoon Pump
Please read these instructions completely before using one of Anjon Pond
Pumps in the table below.
Model
Rated
Voltage
Rated
Current
Input
Motor
Flow
Max
Total
Head
Max.
Operation
Depth
MS-550 120V, 60Hz 0.45A EM3000 550 G/h 11 ft 6.5 ft
MS-800 120V, 60Hz 0.68A EM4500 800 G/h 13 ft 6.5 ft
MS-1200 120V, 60Hz 1.20a EM8000 1200 G/h 18 ft 6.5 ft
MS-1600 120V, 60Hz 1.30A EM10000 1600 G/h 18 ft 6.5 ft
MS-2000 120V, 60Hz 2.35A EM12000 2000 G/h 20 ft 6.5 ft
MS-3000 120V, 60Hz 2.45A EM12500 3000 G/h 21 ft 6.5 ft
MS-4000 120V, 60Hz 2.55A EM15000 4000 G/h 21 ft 6.5 ft
MS-5200 120V, 60Hz 3.55A EM20000 5200 G/h 24 ft 6.5 ft
MS-6100 120V, 60Hz 3.8A EM25000 6100 G/h 27 ft 6.5 ft
MS-8000 120V, 60Hz 4.5A EM30000 8000 G/h 29 ft 6.5 ft
MS-10000 120V, 60Hz 8A EM40000 10000 G/h 39 ft 6.5 ft
These pumps are used as submersible and non-submersible pumps provided
with overload-protected devices in garden ponds, fountains, terraced
fountains, indoor fountains to circulate and oxygenate clear water. You can use
suction cups or four screws to mount it. If mounted to appropriate base, make
sure that the appliance is securely installed before operation.
These pumps are not for use in swimming pools!
CAUTION:These pumps should be installed according to
your local electrical code. Please contact an electrician. For all
technical data, please refer to the content stated on the rating
label of the pump.
p. 1
Monsoon Pump Models: MS-550, MS-800, MS-1200, MS-1600,
MS-2000, MS-3000, MS-4000, MS-5200, MS-6100, MS-8000, MS-10000
LIMITED WARRANTY
Productsmanufactured byANJON are warranted to the original user onlyto befree of defects inmaterial
and workmanship for a period of 24 months from the date of purchase, but not more than 30 months
from the date of manufacture. ANJON liability under this warranty shall be limited to repairing or
replacing, atANJON’s discretion, without charge, F.O.B.ANJON will not be liablefor anycost of removal,
installation, transportation, or any other charges which may arise in connection with a warranty claim.
Products which are sold but not manufactured by ANJON are subject to the warranty provide by the
manufacturer of said product(s) and not by ANJON’s warranty. ANJON will not be liable for damage or
wear to products caused by abnormal operating conditions, accident, abuse, misuse, unauthorized
alteration or repair, or if the product was not installed in accordance with ANJON’s printed installation
and operating instructions.
To obtain service under this warranty, the defective product must be returned to the distributor or dealer
of ANJON’s products from which it was purchased together with proof of purchase and installation date,
failure date, and supporting installation data. Unless otherwise provided, the distributor or dealer will
contactANJON or an authorized service station for instructions. Any defective product to be returned to
ANJON or a service station must be sent freight prepaid: documentation supporting the warranty clam
and/or a Return MaterialAuthorization (RMA) must be included if so instructed. Inthe absence of suitable
proof of purchase date, the effective date of this warranty will be based upon the date of manufacture.
Any replacement product may be either new or like-new, provided that it has functionality at least equal
to that of the product being replaced. No requests for service under this warranty will be accepted if
received more than 30 days after the term of the warranty. Correction of defects, in the manner and for
the duration of the warranty described in this warranty, shall constitute complete fulfillment of all liabilities
and responsibilities of ANJON to the user with respect to the product, and shall constitute full satisfaction
of all claims, whether based oncontract, negligence, strict liability or otherwise. Except for the obligations
specifically set forth in this warranty, in no event shall ANJON be liable for direct, indirect, special,
incidental, or consequential damages, whether based on contract, tort, or any other legal theory and
whether advised of the possibility of such damages.
ANJON reserves the right to change or improve its products or any portions thereof without being
obligated to provide such a change or improvement for units sold and/or shipped prior to such a change
or improvement.

THERE ARE NO EXPRESS OR IMPLIED WARRANTIES, INCLUDING MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE, WHICH EXTEND BEYOND THOSE WARRANTIES
DESCRIBED OR REFERRED TO ABOVE EXCEPT AS EXPRESSLY HEREIN PROVIDED THE
GOODS ARE SOLD “AS IS”, THE ENTIRE RISKAS TO QUALITYAND FITNESS FORA PARTICULAR
PURPOSE, AND PERFORMANCE OF THE GOODS IS WITH THE BUYER, AND SHOULD THE
GOODS PROVE DEFECTIVE FOLLOWING THER PURCHASE, THE BUYER AND NOT THE
MANUFACTURER, DISTRIBUTOR, OR RETAILER ASSUMES THE ENTIRE RISK OF ALL
NECESSARY SERVICING AND REPAIR.
Some jurisdictions do not allow the exclusions or limitation of incidental or consequential damages and
some jurisdictions do not allow limitations on how long implied warranties may last or require you to pay
certain expenses as set forth above.Therefore, the above limitations or exclusionsmay not applyto you.
This warranty gives you specific legal rights and you may also have other rights which vary from
jurisdictions to jurisdiction.
p.7
Safety Instructions
•Read and observe alltheinstruction supplied with the appliance
and on the appliance
•Make sure that your outlet voltage corresponds to those stated
on the rating label of the pump(s).
•Make sure the appliance is securely installed before operating
it.
•The electrical connection should be located in a water-proof
area and should be at least 6 feet away from the edge of the
pond. (see fig. 1)
•Keep the electrical connections dry! Ensure that the electrical
cord loop below the electrical outlet to form a “Drip Loop”. This
will prevent water from running down the cord into the electrical
outlet
•Always unplug the appliance when not in use, before putting on
or taking off parts, before cleaning the pump and before doing
any work for the fountain or pond.
•The pump must not be used when people are working in water.
Please disconnect the pump first.

•Do not operate any appliance with a damaged cord or plug, or
in abnormal state. The supply cord of the appliance cannot be
replaced. If the cord is damaged the appliance should be
scrapped.
•For safety reasons, any repair work should be done only by the
manufacturer of the products orthe authorized service facility or
discard it
•Never hang or transport the pump by meansof pulling thepower
cord!
•Close supervision is necessary when the appliance is used by
or near children.
•If you want to disconnect the pump, you can pull out the plug
and the plug must be placed where you can access it.
•Never use any accessories which are not recommended by the
appliance manufacturer. It may result in fire, electric shock,
personal injury and/or voided warranty.
•The pumps power should be supplied through a Ground Fault
Circuit Interrupter (GFCI) with a rated residual operating current
not exceeding 30mA.
•Min Length of power cord is 30ft.
•To protect against the risk of electrical shock, do not immerse
the plug in water or other liquid.
Used as submersible pumps (see fig. 1)
IMPORTANT: Do not let the pump run dry – this could cause damage to
the motor.
•Submerse the pump completely in your pond so as to make the pump
body fill with water.
•A water level of approx. 6 in. is required for submersible use in order
to prevent the pump from taking in air. (see fig.1)
•The pump is designed to accommodate internal threads as well as
external threads through the socket (fountain jets, nozzles, water
height regulators, standpipes, etc.).
•Running in conjunction with fountain jets, the pump should be
stationed firmly and horizontally (i.e. on a brick)
•The pump can be switched on by simply plugging it in and switched
off by un-plugging it.
•The water temperature should not exceed 95°F (35°C) and do not let
the pump freeze in the wintertime.
•This appliance is not intended for use by persons, (including children)
with reduced physical sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible
for their safety.
•Children should be supervised to ensure that they do not play with the
appliance.
Used as non-submersible pumps (see fig. 2)
•Position the pump lower than the water surface on the side of the pond
so that the water can be drained to the pump because it is not self –
priming.
•Remove the intake cover (see fig.3) and connect suction hose (A) and
pressure hose (B) from the pump. The connection should be
waterproof.
•Fill the suction hose and pump with water before turning it on.
•To prevent the pump from becoming clogged, provide the suction hose
with an adequate suction filter.
•The pump is only suitable for use with GFI (ground fault interrupter)
30 mA outlet. Never let the pump run dry.
Overload Protection
The pump has a built-in thermal overload trip which prevents the pump from
overheating. The pump must be allowed to cool down before restarting. If the
pump will not start again automatically when cooling down please check the
following conditions;
•Is there sufficient water supply? → add water if necessary
•Has dirt entered the pump housing? → follow the cleaning
instructions below
•Have hoses or jets become clogged? → Clean if necessary
•Has the pump sufficiently cooled down after overheating?
•As soon as you have completed this checklist, you can start the
pump again by plugging it back in.
Maintenance and Cleaning (see fig.3)
1. Follow these safety instructions. Make sure that the pump is
unplugged.
2. Press the intake cover (1) together laterally and take it from the pump
housing.
3. Loosen the 4 outer screws (9).
4. Rotate the pump housing (6) ¼ turn Counter Clockwise. Unclip it from
the motor housing (4).
5. Remove the rotor (8) from the motor housing (4).
6. Clean all parts using water and a soft sponge. In hard water conditions
a mixture of CLR and water bath is recommended.
Assembling the pump together
1. Place the rotor (8) in motor housing (4) with caution.
2. Make sure the rotor is assembled correctly and will turn freely and
check the position of the sealing ring (7) on the pump housing (6).
3. Put the pump housing (6) on and turn CW (clockwise) ¼ turn. Tighten
the 4 screws (9) uniformly.
4. Place the intake cover (1) on the pump housing (6) .

WARNING:
•Risk of electric shock – This pump is supplied with a grounding conductor and
grounding type attachment plug. To reduce risk of electric shock, be certain
that it is connected only to a properly grounded, grounding-type receptacle
•Risk of Electric shock. Do not remove cord and strain relief. Do not connect
conduit to pump.
•This pump has been evaluated for use with water only.
•Reduce risk of electric shock during operation of this pump requires the
provision of acceptable grounding
•Risk of electric shock – This pump has not been investigated for use in
swimming pool or marine areas.
•Do not connect to any voltage other that that shown on the pump
•Always disconnect from electrical supply before handling pump.
•Don’t operate without water
•Operate pump completely submerged for proper cooling
DISPOSAL: Do not dispose this product as unsorted municipal waste.
Collection of such waste separately for special treatment is necessary.
Please recycle this product or send it to us for recycling.
This manual suits for next models