Anolis ArcPower 16x6 User manual

Version 1.1

2
Table of contents
1. Safety instructions ......................................................................................................... 3
2. Operating determinations.............................................................................................. 3
3.Description of the ArcPower 16x6 ................................................................................. 4
4.Installation........................................................................................................................ 4
4.1.Connection to the mains: ........................................................................................... 4
4.2.Mounting the ArcPower 16x6 ..................................................................................... 5
4.3.Conection cables........................................................................................................ 5
5 DMX operation ................................................................................................................ 6
5.1 Single ArcPower 16x6 installation.............................................................................. 6
5.2 Multiple ArcPower 16x6 installation ...........................................................................7
6.ArcPower 16x6 - Control menu map.............................................................................. 8
7.ArcPower 16x6 - DMX protocol, version 1.1 ................................................................. 9
8.Control board................................................................................................................. 15
8.1 Addressing the ArcPower 16x6 ............................................................................... 15
8.2 Program editing........................................................................................................ 15
8.3 Manual mode ........................................................................................................... 16
8.4 Test sequences........................................................................................................ 16
8.5 Stand-alone mode.................................................................................................... 17
8.6 Special functions ...................................................................................................... 17
9.Technical Specications: ............................................................................................. 19
10. Replacing the fuse ..................................................................................................... 20
ArcPower 16x6

3
CAUTION!
Unplug mains lead before opening the housing!
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
BEFORE YOU INITIAL START - UP!
1. Safety instructions
Every person involved with installation and maintenance of this product has to:
- be qualiled
- follow the instructions of this manual
CAUTION!
Be careful with your operations. With a high voltage you can suffer
a dangerous electric shock when touching the wires inside the unit!
This product has left our premises in absolutely perfect condition. In order to maintain this condition and to
ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning
notes written in this manual.
To prevent from danger of accident ,the device has to be xed on at, non-amma-
ble surface in compliance with the installing instruction included in this manual.
Important:
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this
manual or any unauthorized modication to the product.
Always ground the unit.
The electric connection, repairs and servicing must be carried out by a qualied employee.
Do not connect this unit to a dimmer pack.
Use a source of AC power that complies with local building and electrical rules.AC power has to have both
overload and short circuit protection
2. Operating determinations
This product was designed for indoor use only.
If the unit has been exposed to drastic temperature uctuation (e.g. after transportation), do not switch it on
immediately. The arising condensation water might damage your unit. Leave the unit switched off until it has
reached room temperature.
Avoid brute force when installing or operating the unit.
When choosing the installation-spot, please make sure that the unit is not exposed to extreme heat, moisture
or dust.
Only operate the unit after having checked that the housing is rmly closed and all screws are tightly fas-
tened.
The maximum ambient temperature 40° C must never be exceeded.
Operate the unit only after having familiarized with its functions. Do not permit operation by persons not quali-
ed for operating the unit. Most damages are the result of unprofessional operation!
Please use the original packaging if the product is to be transported.
Please consider that unauthorized modications on the unit are forbidden due to safety reasons!

4
3.Description of the ArcPower 16x6
LED output zones (RGB operation)
LED output zones (RGBW operation)
DMX Input,Output LED module Input
RJ45 socket RJ45 socket
Front view of the socket: Front view of the socket:
4.Installation
4.1.Connection to the mains:
The ArcPower 16x6 is equipped with auto-switching power supply that automatically adjusts to any 50/60Hz
AC power source from 100-240 Volts.
Carefully prepare the end of the the supply cord and t a suitable plug.A 3-prong grounding-type plug must be
installed following the manufacturer´s instructions.The earth has to be connected!
1- Control board
2- LED output zones
3- DMX Input
4- DMX Output
5- Fuse holder
6- Power cord
Pin 1: Not connected Pin 5: +5V
Pin 2: Not connected Pin 6: Data +
Pin 3: Not connected Pin 7: Data -
Pin 4: Not connected Pin 8: GND
Pin 1: Red LED + Pin 5: Red LED -
Pin 2: Green LED + Pin 6: Green LED -
Pin 3: Blue LED + Pin 7: Blue LED -
Pin 4: White LED + Pin 8: White LED -

5
Cord plug connection:
Cable Pin International
Brown Live L
Light blue Neutral N
Yellow/Green Earth
This device falls under protection class I.Therefore the ArcPower 16x6 has to be
connected to a mains socket outlet with a protective earthing connection.
4.2.Mounting the ArcPower 16x6
The ArcPower 16x6 should be be placed on a non-ammable at surface in any orientation and xed by the
four screws.There are four mounting holes of a diameter 5 mm in housing of the driver. Ensure that instalation
place is enough ventilated.
4.3.Conection cables
1.The adapter cable RJ45/XLR connects the ArcPower 16x6 to the DMX controller.If your DMX controller has
RJ45 socket for DMX output,use RJ45 patch cable for connection with the ArcPower 16x6.
RJ45 plug DMX 512 XLR plug (male)
View facing pins Front view of the plug
Pin 1: Not used Pin 1: GND
Pin 2: Not used Pin 2: Data -
Pin 3: Not used Pin 3: Data +
Pin 4: Not used Pin 4: Not used
Pin 5: +5V Pin 5: Not used
Pin 6: Data +
Pin 7: Data -
Pin 8: GND
Flat surface
Mounting hole
Screws
Screws

6
2.RJ45 patch cables category 5 that connect the ArcPower 16x6 each other are wired 1:1,that is,pins with the
same numbers are connected together.
Pin 1: Not used Pin 1: Not used
Pin 2: Not used Pin 2: Not used
Pin 3: Not used Pin 3: Not used
Pin 4: Not used Pin 4: Not used
Pin 5: +5V Pin 5: +5V
Pin 6: Data + Pin 6: Data +
Pin 7: Data - Pin 7: Data -
Pin 8: GND Pin 8: GND
5 DMX operation
1.Unplug from the mains before installation.
2.Connect the LED modules to the xture according to the operation (RGB or RGBW).
3.Connect DMX controller to the xture
4.Connect the xture to the mains
5.Set the DMX address on the control board of the xture (see chapter "Control board").
6.Run internal calibration of the xture (menu path: SPEC-->CALi--->COMP.)
Warning!
Accidental connection DMX 512 Input/Output to non-DMX 512 device (e.g.Ethernet
network Hub) can damage the ArcPower 16x6.
Maximum total cable length between Arcpower 16x6 and all connected LED modu-
les is 80 metres.
5.1 Single ArcPower 16x6 installation
1. RGB operation
Max. load per LED output zone: 6x1W LED
Number of zones: 16
2. RGBW operation
The ArcPower 16x6 allows to operate 12 RGBW outputs (zones) and it is not necessary to change its menu
setting. You can choose Mode1 for RGBW (up to DMX 48 channels) or Mode2 including the shutter (DMX=
49) and dimmer (DMX= 50) channel - see DMX protocol for RGBW operation.
Note: Only 12 zones of the ArcPower 16x6 can be used for RGBW operation - see chapter 3 "Description
of the ArcPower 16x6".

7
5.2 Multiple ArcPower 16x6 installation
Connect the DMX output of the rst ArcPower 16x6 with the DMX input of the next ArcPower 16x6. Always
connect one output with the input of the next ArcPower 16x6 until all xtures are connected.In this way,up to
32 xtures can be chained together.
At the last ArcPower 16x6 the data link has to be terminated with a terminator. A termination plug is simply a
RJ45 connector with a 120 Ω resistor between pins Data (–) and Data (+).Plug terminator in the DMX output
of the last ArcPower 16x6.
Max. load per LED output zone: 8x1W LED
Number of zones: 12

8
6.ArcPower 16x6 - Control menu map
Default settings=Bold print
A001 (001-464)
ProG
EPG.1
:
EPG.4
St.01
:
St.60
rEd 1 (0-255)
:
dimr. (0-255)
F.tim.(0-255)
S.tim. (0-255)
COPY
P.End. (1-60)
MAn.C.
rEd.1 (0-255)
GrE.1 (0-255)
bLu.1 (0-255)
:
Stro. (0-255)
dimr (0-255)
tESt
St.AL.
Auto
OFF
tESt
:
PrG.5
PLAY.
EPG.1
:
SPEC. PrG.5
VErS
tEmP
CALi
rEd.1 (0-255)
:
bL.16 (0-255)
Stor.
COMP.
bALA. (On,OFF)
C.bAL.
rEd.b. (0-255)
GrE.b.(0-255)
bLu.b. (0-255)
CHAr
EYE
LinE
dM.Pr.
Mod.1
Mod.2
i.bLi (On,Off)
dFSE (no,YES)
uPd (no,YES)

9
7.ArcPower 16x6 - DMX protocol, version 1.1
RGB operation
Mode 1 Mode 2
Value Function Type of con-
trol
Channel Channel
ZONE 1
1 1 0-255
Red LED 1
Red LED saturation control (0-100%) proportional
2 2 0-255
Green LED 1
Green LED saturation control (0-100%) proportional
3 3 0-255
Blue LED 1
Blue LED saturation control (0-100%) proportional
ZONE 2
4 4 0-255
Red LED 2
Red LED saturation control (0-100%) proportional
5 5 0-255
Green LED 2
Green LED saturation control (0-100%) proportional
6 6 0-255
Blue LED 2
Blue LED saturation control (0-100%) proportional
ZONE 3
7 7 0-255
Red LED 3
Red LED saturation control (0-100%) proportional
8 8 0-255
Green LED 3
Green LED saturation control (0-100%) proportional
9 9 0-255
Blue LED 3
Blue LED saturation control (0-100%) proportional
ZONE 4
10 10 0-255
Red LED 4
Red LED saturation control (0-100%) proportional
11 11 0-255
Green LED 4
Green LED saturation control (0-100%) proportional
12 12 0-255
Blue LED 4
Blue LED saturation control (0-100%) proportional
ZONE 5
13 13 0-255
Red LED 5
Red LED saturation control (0-100%) proportional
14 14 0-255
Green LED 5
Green LED saturation control (0-100%) proportional
15 15 0-255
Blue LED 5
Blue LED saturation control (0-100%) proportional
ZONE 6
16 16 0-255
Red LED 6
Red LED saturation control (0-100%) proportional
17 17 0-255
Green LED 6
Green LED saturation control (0-100%) proportional
18 18 0-255
Blue LED 6
Blue LED saturation control (0-100%) proportional
ZONE 7
19 19 0-255
Red LED 7
Red LED saturation control (0-100%) proportional
20 20 0-255
Green LED 7
Green LED saturation control (0-100%) proportional
21 21 0-255
Blue LED 7
Blue LED saturation control (0-100%) proportional
ZONE 8
22 22 0-255
Red LED 8
Red LED saturation control (0-100%) proportional
23 23 0-255
Green LED 8
Green LED saturation control (0-100%) proportional
24 24 0-255
Blue LED 8
Blue LED saturation control (0-100%) proportional

10
Mode 1 Mode 2 Value Function Type of con-
trol
Channel Channel
ZONE 9
25 25 0-255
Red LED 9
Red LED saturation control (0-100%) proportional
26 26 0-255
Green LED 9
Green LED saturation control (0-100%) proportional
27 27 0-255
Blue LED 9
Blue LED saturation control (0-100%) proportional
ZONE 10
28 28 0-255
Red LED 10
Red LED saturation control (0-100%) proportional
29 29 0-255
Green LED 10
Green LED saturation control (0-100%) proportional
30 30 0-255
Blue LED 10
Blue LED saturation control (0-100%) proportional
ZONE 11
31 31 0-255
Red LED 11
Red LED saturation control (0-100%) proportional
32 32 0-255
Green LED 11
Green LED saturation control (0-100%) proportional
33 33 0-255
Blue LED 11
Blue LED saturation control (0-100%) proportional
ZONE 12
34 34 0-255
Red LED 12
Red LED saturation control (0-100%) proportional
35 35 0-255
Green LED 12
Green LED saturation control (0-100%) proportional
36 36 0-255
Blue LED 12
Blue LED saturation control (0-100%) proportional
ZONE 13
37 37 0-255
Red LED 13
Red LED saturation control (0-100%) proportional
38 38 0-255
Green LED 13
Green LED saturation control (0-100%) proportional
39 39 0-255
Blue LED 13
Blue LED saturation control (0-100%) proportional
ZONE 14
40 40 0-255
Red LED 14
Red LED saturation control (0-100%) proportional
41 41 0-255
Green LED 14
Green LED saturation control (0-100%) proportional
42 42 0-255
Blue LED 14
Blue LED saturation control (0-100%) proportional
ZONE 15
43 43 0-255
Red LED 15
Red LED saturation control (0-100%) proportional
44 44 0-255
Green LED 15
Green LED saturation control (0-100%) proportional
45 45 0-255
Blue LED 15
Blue LED saturation control (0-100%) proportional
ZONE 16
46 46 0-255
Red LED 16
Red LED saturation control (0-100%) proportional
47 47 0-255
Green LED 16
Green LED saturation control (0-100%) proportional
48 48 0-255
Blue LED 16
Blue LED saturation control (0-100%) proportional

11
Mode 1 Mode 2 Value Function Type of con-
trol
Channel Channel
- 49
0-31
32-63
64-95
96-127
128-143
144-159
160-255
Shutter/Strobe
Shutter closed
Shutter open
Strobe-effect from slow to fast
Shutter open
Opening pulses in sequences slow--> fast
Closing pulses in sequences fast --> slow
Shutter open
step
step
proportional
step
proportional
proportional
step
- 50 0-255
DImmer
Dimmer intensity from 0% to 100% proportional

12
RGBW operation
Mode 1 Mode 2
Value Function Type of con-
trol
Channel Channel
ZONE 2
4 4 0-255
Red LED 2
Red LED saturation control (0-100%) proportional
5 5 0-255
Green LED 2
Green LED saturation control (0-100%) proportional
6 6 0-255
Blue LED 2
Blue LED saturation control (0-100%) proportional
3 3 0-255
White LED 2
Blue LED saturation control (0-100%) proportional
ZONE 3
7 7 0-255
Red LED 3
Red LED saturation control (0-100%) proportional
8 8 0-255
Green LED 3
Green LED saturation control (0-100%) proportional
9 9 0-255
Blue LED 3
Blue LED saturation control (0-100%) proportional
2 2 0-255
White LED 3
Blue LED saturation control (0-100%) proportional
ZONE 4
10 10 0-255
Red LED 4
Red LED saturation control (0-100%) proportional
11 11 0-255
Green LED 4
Green LED saturation control (0-100%) proportional
12 12 0-255
Blue LED 4
Blue LED saturation control (0-100%) proportional
1 1 0-255
White LED 4
Blue LED saturation control (0-100%) proportional
ZONE 6
16 16 0-255
Red LED 6
Red LED saturation control (0-100%) proportional
17 17 0-255
Green LED 6
Green LED saturation control (0-100%) proportional
18 18 0-255
Blue LED 6
Blue LED saturation control (0-100%) proportional
15 15 0-255
White LED 6
Blue LED saturation control (0-100%) proportional
ZONE 7
19 19 0-255
Red LED 7
Red LED saturation control (0-100%) proportional
20 20 0-255
Green LED 7
Green LED saturation control (0-100%) proportional
21 21 0-255
Blue LED 7
Blue LED saturation control (0-100%) proportional
14 14 0-255
White LED 7
Blue LED saturation control (0-100%) proportional
ZONE 8
22 22 0-255
Red LED 8
Red LED saturation control (0-100%) proportional
23 23 0-255
Green LED 8
Green LED saturation control (0-100%) proportional
24 24 0-255
Blue LED 8
Blue LED saturation control (0-100%) proportional
13 13 0-255
White LED 8
Blue LED saturation control (0-100%) proportional

13
Mode 1 Mode 2 Value Function Type of con-
trol
Channel Channel
ZONE 10
28 28 0-255
Red LED 10
Red LED saturation control (0-100%) proportional
29 29 0-255
Green LED 10
Green LED saturation control (0-100%) proportional
30 30 0-255
Blue LED 10
Blue LED saturation control (0-100%) proportional
27 27 0-255
White LED 10
Blue LED saturation control (0-100%) proportional
ZONE 11
31 31 0-255
Red LED 11
Red LED saturation control (0-100%) proportional
32 32 0-255
Green LED 11
Green LED saturation control (0-100%) proportional
33 33 0-255
Blue LED 11
Blue LED saturation control (0-100%) proportional
26 26 0-255
White LED 11
Blue LED saturation control (0-100%) proportional
ZONE 12
34 34 0-255
Red LED 12
Red LED saturation control (0-100%) proportional
35 35 0-255
Green LED 12
Green LED saturation control (0-100%) proportional
36 36 0-255
Blue LED 12
Blue LED saturation control (0-100%) proportional
12 12 0-255
White LED 12
Blue LED saturation control (0-100%) proportional
ZONE 14
40 40 0-255
Red LED 14
Red LED saturation control (0-100%) proportional
41 41 0-255
Green LED 14
Green LED saturation control (0-100%) proportional
42 42 0-255
Blue LED 14
Blue LED saturation control (0-100%) proportional
39 39 0-255
White LED 14
Blue LED saturation control (0-100%) proportional
ZONE 15
43 43 0-255
Red LED 15
Red LED saturation control (0-100%) proportional
44 44 0-255
Green LED 15
Green LED saturation control (0-100%) proportional
45 45 0-255
Blue LED 15
Blue LED saturation control (0-100%) proportional
38 38 0-255
White LED 15
Blue LED saturation control (0-100%) proportional
ZONE 16
46 46 0-255
Red LED 16
Red LED saturation control (0-100%) proportional
47 47 0-255
Green LED 16
Green LED saturation control (0-100%) proportional
48 48 0-255
Blue LED 16
Blue LED saturation control (0-100%) proportional
37 37 0-255
White LED 16
Blue LED saturation control (0-100%) proportional

14
Mode 1 Mode 2 Value Function Type of con-
trol
Channel Channel
- 49
0-31
32-63
64-95
96-127
128-143
144-159
160-255
Shutter/Strobe
Shutter closed
Shutter open
Strobe-effect from slow to fast
Shutter open
Opening pulses in sequences slow--> fast
Closing pulses in sequences fast --> slow
Shutter open
step
step
proportional
step
proportional
proportional
step
- 50 0-255
DImmer
Dimmer intensity from 0% to 100% proportional

15
8.Control board
The control panel situated on the top cover of the ArcPower 16x6 allows DMX addressing and set
the xture´s behaviour.
Control elements:
[ENTER] button- enters menu,conrms adjusted values and leaves menu.
, [UP] button and[DOWN] button- moves between menu items on the the same level, sets values.
[ESCAPE] button- leaves the menu without saving value.
After switching on the ArcPower 16x6 ,the display shows the initial DMX address:
Use [UP],[DOWN] to browse through the menu. To select a function or submenu,press [ENTER].
8.1 Addressing the ArcPower 16x6
Setting the DMX start channel:
1. Connect the ArcPower 16x6 to the mains.
2. Browse through the menu by pressing the [UP] and [DOWN] buttons until the display shows current addres
"A001".Conrm by pressing [ENTER] button and "A001" will start to ash frequently.
3. Use the [UP] and [Down] buttons to select the desired address.
4. Conrm by pressing [ENTER].
After having addressed ArcPower 16x6,you may now start operating ArcPower 16x6 via your DMX control-
ler.
8.2 Program editing
By entering this menu a complete overview of all editable programs is offered,from which the program to be
edit can be selected by pressing [ENTER].The xture includes 4 free editable programs (EPG.1-EPG.4),each
up to 60 steps.
Each program step has a Fade time-the time during which effects go to the current step and
a Standing time-the time,during which effects last in the current step.
Programming procedure:
1. Enter "ProG." menu
2. Press [UP] or [DOWN] to select the desired program which you wish to edit and press [ENTER].
3. Press [UP] or [DOWN] to select the desired program step and press [ENTER].
4. Press [UP] or [DOWN] to select the desired item and press [ENTER]-button.Now you can edit by using [UP]
or [DOWN] buttons the DMX value of the selected item:

16
"P.End" - a total number of the program steps (value 1-60).This value should be set
before start programming (e.g. if you want to create program with 10 steps,set End=10).
"rED1" - a red LED 1 saturation,value 0-255
"GrE1"- a green LED 1 saturation,value 0-255
"bLu1"- a blue LED1 saturation,value 0-255
: :
"rE16" - a red LED 16 saturation,value 0-255
"Gr16" - a green LED 16 saturation,value 0-255
"bL16"- a blue LED16 saturation,value 0-255
"Str." - a strobe,value 0-255
"dim." - a dimmer,value 0-255
"FA.t." - fade time,value 0-255 *
"S.tI." - standing time,value 0-255 *
"COPY" - copying the current prog. step to the next prog. step.
Press [ENTER]-button to conrm adjusted value .
5.Repeat steps 3 and 4 for next prog.step.If you want to copy current prog. step to the next prog.step, select
option "COPY"and conrm it by pressing [ENTER].
*Both Fade time and Standing time use the same conversion table in order to convert DMX value to the time
value:
DMX Time
[sec.]
DMX Time
[min.]
DMX Time
[min.]
DMX Time
[min.]
DMX Time
[min.]
10.1 50 4.2 105 18.4 160 42.7 215 77
20.4 55 5110 20.2 165 45.4 220 80.7
52.5 60 6115 22 170 48.2 225 84.4
10 10 65 7120 24 175 51 230 88.2
15 22.5 70 8.2 125 26 180 54 235 92
20 40 75 9.4 130 28.2 185 57 240 96
25 62.5 80 10.7 135 30.4 190 60.2 245 100
30 90 85 12 140 32.7 195 63.4 250 104
35 122.5 90 13.5 145 35 200 66.7 255 108
40 160 95 15 150 37.5 205 70
45 202.5 100 16.7 155 40 210 73.5
Exact expression of the time value follows the formula: time[sec.]=(DMX value)2/10.
8.3 Manual mode
This menu gives access to the control of the xture channels by means of the control board buttons.
Use [UP] and [DOWN] buttons until the display shows "MAn.C." menu.Press [ENTER] button and by using [UP]
and [DOWN] buttons select desired effect,press [ENTER] and and by using [UP] and [DOWN] buttons adjust
desired DMX value for selected effect.Conrm by [ENTER].
"rEd1" a red LED1 saturation
"GrE1." a green LED1 saturation
"bLu1." a blue LED1 saturation
:
"rE.16" a red LED16 saturation
"Gr.16" a green LED16 saturation
"bL.16" a blue LED16 saturation
"Str." a strobe,value 0-255
"dimr. a dimmer,value 0-255
8.4 Test sequences
Use the item to run a demo-test sequences without an external controller,which will show you some possibili-
ties of using the xture.

17
8.5 Stand-alone mode
Use this menu to run a program or to set a running program in the stand-alone operation - operation without
connected DMX controller
Auto --- Presetting playback.This function allows you to select the program which will be played continuously
in a loop after switching the xture on.The xture has four freely-programmable programs (EPG1-EPG4) and
ve built-in programs (PrG1-PrG5).
OFF --- The option disables "Auto" function.
tSt --- The option starts test program
EPG.1 --- The option starts editable program No.1
:
EPG.4 --- The option starts editable program No.4
PrG. 1 --- The option starts built-in program No.1
:
PrG. 5 --- The option starts built-in program No.5
PLAY --- Playing program.Select this menu to run a desired program immediately.
EPG.1 --- The option starts editable program No.1
:
EPG.4 --- The option starts editable program No.4
PrG. 1 --- The option starts built-in program No.1
:
PrG. 5 --- The option starts built-in program No.5
Select the program you wish and press [ENTER].The selected program starts running.By Pressing [ENTER]
again is possible to pause the program running.
8.6 Special functions
Use this menu for special services.
VErS. --- Software Version.Select this function to read the number of the xture software version.
tEmP. --- Fixture temperature.This item indicates temperature inside of the ArcPower 16x6.
bALA. --- Balance.Select this function to enable (On) or disable (OFF) the white balance which is set in "White
colour balance" menu below.If this function is set OFF,ArcPower 16x6 will use maximum value (255) of satura-
tion for red, green and blue channels.
CALi. --- LED intensity calibration.The menu allows you to adjust the max. light intensity of individual LEDs
(colour channels),e.g. the light intensity of all red LEDs connected to the channel 4.This action is suitable in case
that adjacent LEDs (e.g. in LED array) have a different light intensity (but these LEDs have to be connected to
the different zones of the ArcPower 16x6).
Use [UP] and [DOWN] buttons to select desired LED,press [ENTER] and adjust suitable light intensity (0-255)
using [UP] and [Down] buttons,conrm by pressing [ENTER].This adjusted light intensity is its maximum intensity
which can be reached if dimmer=255 DMX. After calibration all LEDs, select Stor. to save adjusted values.
COMP.- Internal calibration.The function eliminates random light ashes during slow dimming.The
calibration action lasts cca one minute.
The COMP function should be performed:
- once after connecting all LEDs to the xture (after complete installation)
- if the load has been changed (e.g 6-LEDs modules have been replaced by 3-LEDs)
- after software upgrade or changing dimmer characteristic (SPEC--->CHAr)
C.bAL. --- White colour balance.
Using this menu you can set white balance:
1. Set all red,green and blue channels on maximum saturation(255)
2. Browse through the menu by pressing the [UP] and [DOWN] buttons until the display shows "C.bAL."
menu.Press [ENTER] button and "rEd.b." will appear on the display.
3.Press [ENTER] button again and use [UP] and [DOWN] buttons to adjust the new maximum value required
for the red channel.Conrm your choice by pressing [ENTER].Use the [UP] and [Down] buttons to select next
colour.

18
4.Repeat step 3 for green channel "GrE.b." and for blue channel "bLu.b".
CHAr. --- Dimmer characteristic.
The option allows selection from the 2 dimming curves:
EYE - The dimming curve takes into account a gamma curve
LinE - Linear running of the dimming curve.
Use [UP] and [DOWN] buttons to select desired dimmer characteristic and press [ENTER] to conrm.
dM.Pr. --- DMX presetting.The function allows to select desired DMX mode.Use [UP] and [DOWN] buttons
to select desired channel mode (“Mod.1,Mod.2”) and press [ENTER] to conrm.For detail description of all
channels see DMX protocol.
i.bLi. --- Initial blink.If this function is on,ArcPower 16x6 makes auto-calibration (All LEDs lit on 100% for short
time) after switching the ArcPower 16x6 on.If this function is set off,you have to set manually every colour
channel on max.brightness after switching the driver on before starting regular operating.This action should
last min. one second for each colour.During this action the ArcPower 16x6 nds out the load connected to its
LED outputs and makes auto-calibration.
dF.SE. --- Default Settings .Select this option to reset all xture personalities to the default values.
uPd. --- Software update
- Using this function you can update software in the xture via PC and serial link.
The following are required in order to update software:
- PC running Windows 95/98/2000/XP or Linux
- DMX Software Uploader
- Flash cable RS232/DMX (No.13050624)
Note1:Software update should execute a qualied person.If you lack qualication, do not attempt the update
yourself and ask for help your ANOLIS distributor.
Note 2:DMX address,programs and all settings will be set to their default values.
To update software in the xture:
1.Installation of DMX Software Uploader:
1.DMX Software Uploader program is available from the ANOLIS web site at WWW.anolis.cz.
2.Make a new directory ( e.g. ANOLIS_Uploader) on your hard disk and download the software to it.
3.Unpack the program from the archives. Program le has name:DSU_name of corresponding
xture_SoftwareID.SoftwareID describes the versions of xture software included in DMX Software
Uploader. Higher number means later software versions.
2.Fixture software updating:
1.Determine which of your COM port is available on your PC and connect it with to the DMX input
of the xture using the Flash cable. Do not extend this cable! Disconnect the xture from the
other xtures in DMX chain! Turn on the computer and the xture.
2.Switch the xture to the update mode by selecting the option Software update in menu Special
Functions on the xture control panel:SPEC-->UPd-->yES.(From this option you cannot return
back to the main menu. If you do not want to continue in software update, you have to switch off
and on the xture to leave this option!)
3.It is recommended that you exit all programs before running the Software Uploader.
4.Start the Software Uploader program. Select desired COM and then click Connect button.
If the conection is OK, click Start Uploading button to start uploading. It will take several minutes to
perform software update.All processors will be updated (including processors with the same
software version).
If you wish to update only later versions of processors, enable the Incremental Update check box.
Avoid interrupting the process. Update status is being displayed in the list window.
When the update is nished, the line with the text “The xture is successfuly updated‘ will appear
in this window and the xture will reset with the new software.
Note: In the case of interruption of the upload process (e.g. power cut), the xture remains in the update mode
and you have to repeat the software update again.
For example: The xture was switched off before nishing software upload. After switching the xture on again,
the xture is still in the update mode and the display is dark. Restart the Software Uploader program and repeat
software update from your PC.

19
9.Technical Specications:
Power supply:
Input Voltage: 100-240 V AC, 50/60 Hz
Fuse:T 2 A H
Max.Pover Consumption:170VA
Input:
Control:DMX 512
DMX connection:RJ45
Output:
Max.Output Voltage:12V DC
Max.Output current per zone:350mA per colour
RGB operation
LED zones: 16
Max.load per zone: 6 x 1W LED
Total max.load: 16x6 LEDs
RGBW operation
LED zones: 12
Max.load per zone: 8 x 1W LED
Total max.load: 12x8 LEDs
Maximum total cable length between one zone of the Arcpower 16x6 and connected LED modules:
80 metres at max.load.
DMX channels:
Mode 1: 48
Mode 2: 50
Control and programming:
Protocol: USITT DMX-512
Operating modes:DMX,Stand-alone
Display:4 digit LED
White colour balance adjusting
Manual control of all DMX channels via control panel
Programs:5 Built-in programs
4 Freely programmable programs
Operating temperature:
-10°C/+40°C
Dimensions(mm):

20
Weight:
2 kg
Optional accessories:
Adaptor RJ45/DMX 3 pin.......No.13050730
Adaptor RJ45/DMX 5 pin.......No.13050731
10. Replacing the fuse
1.Before replacing the fuse, unplug mains lead!
2.Unscrew the fuse holder on the rear side of the ArcPower 16x6 with a tting screwdriver from the housing
(anti-clockwise).
3.Remove the old fuse from the fuse holder.
4.Install the new fuse in the fuse holder.
5.Replace the fuse holder in the housing and x it.
Specications are subject to change without notice.
April 1, 2009
Table of contents