ANTAIRA LMX-C602G-SFP-V2 Series User manual

Antaira Technologies
LMX-C602G-SFP-V2 Series
6-Port Industrial Compact Light Layer 3 Managed Ethernet
Switch, 4*10/100/1000TX and 2*100/1000 SFP Slots
Quick Installation Guide
Version 1.0
(February 2021)
Tel: 1-844-268-2472
Fax: 1-714-671-9944
www.antaira.com
19020000000144
Package Checklist
The package contains the following items:
⚫1 –Quick installation guide
⚫1 –LMX-C602G-SFP(-T)-V2
⚫1 –Wall mounting bracket set with screws
⚫1 –DC cable –18 AWG & DC jack 5.5 x 2.1mm
⚫1 –Dust cover set
⚫1 –Mini-USB B type male to DB9 RS-232 female cable
Front Panel Layout
Product Overview
System Interface/Performance
All RJ45 ports support the auto MDI/MDI-X function
Embedded 4*10/100/1000Tx and 2*100/1000 SFP slots
Store-and-Forward switching architecture
8K MAC address table
Supports 9.6Kbytes jumbo frame
4Mbits memory buffer
Power Input & Connection
DC 12 to 48V redundant power, with a 6-pin removal
terminal block
Max. current: 0.9A
Relay contact: 24VDC, 1A resistive
It is recommended to use a UL listed industrial power supply
Operating Temperature
Standard operating temperature model: -10°C to 65°C
Extended operating temperature model: -40°C to 75°C
Case/Installation
IP40 protection
DIN-Rail and wall mount design
LED Indicators
LED
Color
Description
Power 1
Green
On
Power input 1 is active
Off
Power input 1 is inactive
Power 2
Green
On
Power input 2 is active
Off
Power input 2 is inactive
Status
Red
On
System booting
Green
On
The system is ready. There are no events
occurring.
Flashing
When the user presses the reset button
Red
On
The system is working normally, but the software
set event occurs (ex. Power inactive, Ethernet
port link down, etc.)
Flashing
When the user presses the reset button
Master
Green
On
ERPS Owner Mode (Ring Master) is ready
Off
ERPS Owner Mode is not active
Ring
Green
On
ERPS Ring Network is active
Flashing
ERPS Ring works abnormally or misconfigure
Off
ERPS Ring Network is not active
SFP Port 1~2
Green
On
Connected to network, 1000Mbps
Flashing
Networking is active
Off
Not connected to network
Amber
On
Connected to network, 100Mbps
Flashing
Networking is active
Off
Not connected to network
LAN Port 3~6
(Upper LED)
Green
On
Connected to network, 1000Mbps
Flashing
Networking is active
Off
Not connected to network
LAN Port 3~6
(Lower LED)
Green
On
Connected to network, 10/100Mbps
Flashing
Networking is active
Off
Not connected to network
Grounding Screw
LAN# 3~6 –10/100/1000Tx RJ45
LAN# 3~6 LED for Link/Activity Status
10/100Mbps
Reset Button
LED for Power 1, Power 2, Status,
Master, Ring
Console Port
USB for Configuration Back-up
LAN# 3~6 LED for Link/Activity Status
1000Mbps
SFP# 1~2 LED for Link/Activity Status
SFP# 1~2 –100/1000
6-Pin Removal Terminal Block (Power Input)
Quick Installation
Ethernet Ports
RJ45 Ports (Auto MDI/MDI-X)
All RJ45 ports are auto-sensing for 10Base-T, 100Base-TX or
1000Base-T device connections. Please follow the wiring pin
assignment table below for Ethernet port installation.
RJ45 Ethernet Port Pin Outs
Pins
T568A Color
T568B Color
10Base-T,
100Base-TX
1000
Base-T(X)
Pin 1
white/green stripe
white/orange stripe
Rx+
TP0+
Pin 2
green solid
orange solid
Rx-
TP0-
Pin 3
white/orange stripe
white/green stripe
Tx+
TP1+
Pin 4
blue solid
blue solid
unused
TP2+
Pin 5
white/blue stripe
white/blue stripe
unused
TP2-
Pin 6
orange solid
green solid
Tx-
TP1-
Pin 7
white/brown stripe
white/brown stripe
unused
TP3+
Pin 8
brown solid
brown solid
unused
TP3-
Power Input Wiring
Please follow the steps below to insert the power wire:
1. Insert the positive and negative wires into the PWR1
(V1+, V1-) and PWR2 (V2+, V2-) contacts on the
terminal block connector as shown below in Figure 1.
2. Tighten the wire-clamp screws to prevent the wires from
loosening, as shown below in Figure 2.
Figure 1 Figure 2
Industrial Switch Mounting
DIN-Rail Mounting
The DIN-Rail bracket is pre-installed on the industrial Ethernet
switch from the factory. Please refer to Figure 3 for a DIN-Rail
bracket installation reference.
Follow the steps below for installing the industrial switch on the
DIN-Rail track:
1. Insert the top of the DIN-Rail on to the track as shown below
in Figure 4.
2. Lightly pull down the bracket on to
the rail as shown below in Figure 5.
3. Check if the bracket is mounted
tightly on the rail.
4. To remove the industrial
Ethernet
switch
from the rail, do the opposite from
the steps above.
Wall Mounting
Follow the steps below to mount the industrial Ethernet switch
using the wall mounting bracket as shown below in Figure 6.
1. Remove the DIN-Rail bracket from the industrial Ethernet
switch by loosening the screws.
2. Place the wall mounting brackets on the top and bottom of
the industrial Ethernet switch.
3. Use the screws to screw the wall
mounting bracket on the industrial
Ethernet switch.
4. Use the hook holes at the corners
of the wall mounting bracket to
hang the industrial Ethernet switch
on the wall.
5. To remove the wall mount bracket,
do the opposite from the steps
above.
Field Maintenance and Service
⚫If the device requires servicing of any kind, the user is
required to disconnect and remove it from its mounting. The
initial installation should be done in a way that makes this as
convenient as possible.
⚫Voltage/power lines should be properly insulated as well as
other cables. Be careful when handling them so as to not trip
over.
⚫Do not under any circumstance insert foreign objects of any
kind into the heat dissipation holes located in the different
faces of the device. This may not only harm the internal
layout, but might cause harm to user as well.
⚫Do not under any circumstance open the device for any
reason. Please contact your dealer for any repair needed or
follow the instructions within the manual.
Warranty Policy
Warranty Conditions
Products supplied by Antaira Technologies are covered in this
warranty for sub-standard performance or defective
workmanship. The warranty is not, however, extended to goods
damaged in the following circumstances:
(a) Excessive forces or impacts
(b) War or an Act of God: wind storm, fire, flood, electric shock,
earthquake
(c) Use of unqualified power supply, connectors, or
unauthorized parts/kits
(d) Replacement with unauthorized parts
RMA and Shipping Costs Reimbursement
Customers shall always obtain an authorized "RMA" number
from Antaira before shipping the goods for repair or
replacement.
•Within the warranty period (based on the invoice date), all
parts and labor are free of charge to the customers.
•Customers are responsible for the cost of parts and labor, if
the products are out of warranty.
•For RMA service, customers are responsible for the shipping
expense for shipping the RMA unit(s) to Antaira. Antaira is
responsible for the shipping expense via a ground service
for the return repair/replace unit(s) back to customers.
Limited Liability
Antaira would not be held responsible for any consequential
losses from using Antaira’s product.
Warranty Period
5-Year Warranty
Antaira’s Customer Service and Support
•Antaira’s Technical Service & Support Centers:
+ 844-268-2472 (Antaira US Headquarter)
+ 48-22-862-88-81 (Antaira Europe Office)
+ 886-2-2218-9733 (Antaira Asia Office)
•Antaira’s Web Sites & Repair/Support Emails:
www.antaira.com / [email protected]
www.antaira.eu / [email protected]
www.antaira.com.tw / [email protected]
*Any changes will be announced on the Antaira website.
Figure 3
Figure 6
Figure 5
Figure 4

Other manuals for LMX-C602G-SFP-V2 Series

1

This manual suits for next models

2

Other ANTAIRA Switch manuals

ANTAIRA LNP-0800G Series User manual

ANTAIRA

ANTAIRA LNP-0800G Series User manual

ANTAIRA LNX-500A-T User manual

ANTAIRA

ANTAIRA LNX-500A-T User manual

ANTAIRA LNX-800AG User manual

ANTAIRA

ANTAIRA LNX-800AG User manual

ANTAIRA LMX-2004G-SFP Series User manual

ANTAIRA

ANTAIRA LMX-2004G-SFP Series User manual

ANTAIRA LMX-0800-T User manual

ANTAIRA

ANTAIRA LMX-0800-T User manual

ANTAIRA LMP-0702G-SFP-V2 Series User manual

ANTAIRA

ANTAIRA LMP-0702G-SFP-V2 Series User manual

ANTAIRA USB-HUB4K User manual

ANTAIRA

ANTAIRA USB-HUB4K User manual

ANTAIRA LMX-2012G-SFP Series User manual

ANTAIRA

ANTAIRA LMX-2012G-SFP Series User manual

ANTAIRA LMX-1002G-SFP Series User manual

ANTAIRA

ANTAIRA LMX-1002G-SFP Series User manual

ANTAIRA LNP-0500-24 Series User manual

ANTAIRA

ANTAIRA LNP-0500-24 Series User manual

ANTAIRA LNX-1002G-SFP Series User manual

ANTAIRA

ANTAIRA LNX-1002G-SFP Series User manual

ANTAIRA LMP-0600-24 User manual

ANTAIRA

ANTAIRA LMP-0600-24 User manual

ANTAIRA LMX-0501G-SFP Series User manual

ANTAIRA

ANTAIRA LMX-0501G-SFP Series User manual

ANTAIRA LMP-1002C-SFP-24 Series User manual

ANTAIRA

ANTAIRA LMP-1002C-SFP-24 Series User manual

ANTAIRA LNP-0702G-SFP Series User manual

ANTAIRA

ANTAIRA LNP-0702G-SFP Series User manual

ANTAIRA LNX-2012GN-SFP User manual

ANTAIRA

ANTAIRA LNX-2012GN-SFP User manual

ANTAIRA LNX-1604G-SFP Series User manual

ANTAIRA

ANTAIRA LNX-1604G-SFP Series User manual

ANTAIRA LNP-C501G-SFP-bt Series User manual

ANTAIRA

ANTAIRA LNP-C501G-SFP-bt Series User manual

ANTAIRA LMX-0602-V2 Series User manual

ANTAIRA

ANTAIRA LMX-0602-V2 Series User manual

ANTAIRA LMP-0702G-SFP-bt-V2 Series User manual

ANTAIRA

ANTAIRA LMP-0702G-SFP-bt-V2 Series User manual

ANTAIRA USB-HUB4K User manual

ANTAIRA

ANTAIRA USB-HUB4K User manual

ANTAIRA LNP-C501G-SFP-bt-24 Series User manual

ANTAIRA

ANTAIRA LNP-C501G-SFP-bt-24 Series User manual

ANTAIRA LNP-0802C-SFP Series User manual

ANTAIRA

ANTAIRA LNP-0802C-SFP Series User manual

ANTAIRA LNP-0602 Series User manual

ANTAIRA

ANTAIRA LNP-0602 Series User manual

Popular Switch manuals by other brands

rotork SS Safety manual

rotork

rotork SS Safety manual

Broadcast Devices CDS-302 Technical reference manual

Broadcast Devices

Broadcast Devices CDS-302 Technical reference manual

steute ZS 73 HES Extreme Mounting and wiring instructions

steute

steute ZS 73 HES Extreme Mounting and wiring instructions

Avid Technology MEDIAswitch manual

Avid Technology

Avid Technology MEDIAswitch manual

RJG L-LS Installation

RJG

RJG L-LS Installation

Spectracom SAS17E user manual

Spectracom

Spectracom SAS17E user manual

Cisco Catalyst 9300X Hardware installation guide

Cisco

Cisco Catalyst 9300X Hardware installation guide

Freedom9 freeStor 4P Specifications

Freedom9

Freedom9 freeStor 4P Specifications

HPE FlexNetwork 10500 SERIES Security configuration guide

HPE

HPE FlexNetwork 10500 SERIES Security configuration guide

Dahua MJHJ4P quick start guide

Dahua

Dahua MJHJ4P quick start guide

Extreme Networks BlackDiamond 8800 Series Hardware installation guide

Extreme Networks

Extreme Networks BlackDiamond 8800 Series Hardware installation guide

TechniSat GigaSwitch 11/20K Installation Manual and User Instructions

TechniSat

TechniSat GigaSwitch 11/20K Installation Manual and User Instructions

Enterasys I3H252-12TX datasheet

Enterasys

Enterasys I3H252-12TX datasheet

Xantech XT-SW21-4K18G user manual

Xantech

Xantech XT-SW21-4K18G user manual

Anker 68ANHUB-B10A Welcome guide

Anker

Anker 68ANHUB-B10A Welcome guide

Brocade Communications Systems AM866A - StorageWorks 8/8 Base SAN Switch Administrator's guide

Brocade Communications Systems

Brocade Communications Systems AM866A - StorageWorks 8/8 Base SAN Switch Administrator's guide

Digitus DA-70220 user manual

Digitus

Digitus DA-70220 user manual

CHERUBINI wiDom Smart Dry Contact Switch 7 operating instructions

CHERUBINI

CHERUBINI wiDom Smart Dry Contact Switch 7 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.