Content
General
Using the AlarmBox-GSM
Safety Instructions
Scope of Delivery
Hardware
Software
System Requirements
Technical Features
G eneral
Load Circuit
GSM
CE-Marking
Installation
Hardware
Handling
ON-LED Blink Codes
GSM
Getting Started
Parameters
Blink Codes
Controlling the AlarmBox-GSM via Voice-Call
Controlling the AlarmBox-GSM via SMS
Alarming
Quick Introduction
Controlling the AlarmBox-GSM via Landline or Mobile Phone
Troubleshooting
Terminology
- 2 -
Hasenbrink 4 32052 Herford Germany Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628

antrax Datentechnik GmbH
[email protected] - www.antrax.de
General
The AlarmBox-wireless, Model GSM allows monitoring of the temperature (via temperature
sensor) and the 230V supply voltage. Exceeded or fallen below the pre-set temperature limits or a
power supply failure the alarm can be sent over a voice-call ("normal" phone call from the box) or
via a text message (SMS) from the box.
Also the AlarmBox-wireless, Model GSM allows to remotely switch ON and OFF a 230V electrical
appliance over a voice-call ("normal" phone call call to the box) or via text message (SMS) to the
the box.
Before first use please read this instruction manual carefully. It contains information for the correct
use and contains important tips for the installation of the AlarmBox-wireless, Type GSM
(hereafter called AlarmBox-GSM). The manufacturer does not accept any liability due to improper
use of the unit. In this case all guarantee claims are invalid.
U sing the Alarm Box-GSM
Die AlarmBox-GSM is designed for monitoring of
temperature (-35°C to 75°C)
and
230V power supply
and the switching of
resistive loads i. e. electric bulbs or heating fans
or
inductive loads i. e. electric motors or transformers to a maximum consumption of
2000W (230V / 8 7A)
in dry closed residential rooms and offices. Rules and Regulations governing the connection and
use of electronic devices and their security regulations must be followed.
- 3 -
Hasenbrink 4 32052 Herford Germany Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628

antrax Datentechnik GmbH
[email protected] - www.antrax.de
Safety Instructions
Do not open the AlarmBox-GSM. It contains no parts to be serviced by you.
Only use the AlarmBox-GSM indoors and do not subject the unit to moisture or humidity.
Also use the temperature sensor without the influence of humidity.
Only connect the AlarmBox-GSM to properly installed 230V AC outlets and power strips.
Only clean the exterior of the AlarmBox-GSM with a dry cloth after unplugging it from the
electrical outlet and removal of the interface cable.
Do not overload the AlarmBox-GSM above its load specification level. An overload can
lead to the AlarmBox-GSM being destroyed.
Do not use the AlarmBox-GSM within the reach of children.
Do not use the AlarmBox-GSM if one or several parts (case cable plug temperature
sensor) are damaged or damage may be caused by its location (e.g. falling down).
Repairs to the AlarmBox-GSM can only be performed by authorized personnel.
Only connect electrical appliances that have no limit to their switched-on time (i.e. all
connected electrical appliances must be able to take continuous current without sustaining
damage in the case of a default to the permanently "ON" position.).
Caution:
Safety Instruction for the wireless module:
The AlarmBox-GSM contains a mobile component like the ones used in mobile phones. Thus in
principle all safety instructions and precautions apply as with the use of mobile phones in particular
are the following:
Do not use the AlarmBox-GSM in the vicinity of medical devices such as hearing aids or
cardiac pacemakers. Functioning of these devices could be disturbed.
The AlarmBox-GSM may be operated in the vicinity of for example TV sets radios or PCs
however but could cause disturbances in operation.
If an external mobile antenna is connected the above mentioned information shall apply
accordingly for this antenna.
The AlarmBox-GSM is designed for stationary use not for use in vehicles of all kinds.
- 4 -
Hasenbrink 4 32052 Herford Germany Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628

antrax Datentechnik GmbH
[email protected] - www.antrax.de
Deliver
Hardware
Everything there? The delivery of a AlarmBox-GSM unit contains:
the AlarmBox-GSM incl. temperature sensor (whit approx. 2m connector cable)
this manual
Software
Software is not required for the control of the AlarmBox-GSM
S stem Requirements
General
SIM card (pre-paid or contract)
- 5 -
Hasenbrink 4 32052 Herford Germany Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628

antrax Datentechnik GmbH
[email protected] - www.antrax.de
Technical Features
General
Operating voltage: 230/240V~ 50/60Hz
Protection class: IP20 for dry rooms only
Connector system: SCHUKO
The current switching status is indicated by a green LED (labelled "ON")
The current GSM status is indicated by a red/green LED (labelled "GSM")
Load and control circuits have a safe electrical separation
Ambient temperature: 0 ... +40°C
Storage temperature: 10 ... +70°C
Temperature Sensor
Cable length: approx. 2m
Measuring temperature: -35 … +75°C
Load Circuit
Operating voltage: 230/240V~ 50/60Hz
Single-pole load switch (Relay)
Maximum switching capacity:
-Resistance loads i.e. electric light bulbs or heating fans up to 2000 W (230 V / 8.7A)
(8 7A at 230/240V)
-Inductive loads i.e. electric motors and transformers up to 2000W (8 7A at 230/240V)
GSM
Integrated GSM-Module: Telit GE865-QUAD
Aerial connector: SMA
Use with pre-paid or contract SIM cards of all providers no SIM lock!
CE Marking
In accordance with the Low Current and EMV Guidelines.
- 6 -
Hasenbrink 4 32052 Herford Germany Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628

antrax Datentechnik GmbH
[email protected] - www.antrax.de
Installation
Hardware
Insert the 230V plug of the device to be monitored by the AlarmBox-GSM into the socket
of the AlarmBox-GSM
Insert the AlarmBox-GSM into a 230V outlet socket
CAUTION: after inserting the AlarmBox-GSM socket the connected device is switched ON
or OFF depending on the previous set state
place the temperature sensor where the temperature shall be monitored
the socket of the AlarmBox-GSM can be switched (''toggled'') by pressing the push-button
(at the bottom of the box) for 3 seconds at least
Operation
The AlarmBox-GSM is operated solely via SMS commands a voice call or via the push-button (at
the bottom of the box).
Blinc codes of the ON-LED
The ON-LED signals the current state of the AlarmBox-GSM. It signals whether an existing alarm
has already been reported. In case of alarm and the deposited alarm phone number has not been
reached yet the ON-LED blinks (depending on the alarm type) as described below. If the alarm
situation has been resolved successfully the ON-LED signals the current state of the socket.
ON-LED Meaning
Permanently OFF Socket OFF
Permanent ON Socket ON
1 x red The set temperature limits have fallen below or have
been exceeded
2 x red Socket in reset mode
3 x red The supply voltage has failed
4 x red The temperature sensor is defect
- 7 -
Hasenbrink 4 32052 Herford Germany Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628

antrax Datentechnik GmbH
[email protected] - www.antrax.de
Button
Keeping the button pressed for more than 3 seconds the state of the socket is being ''toggled'. The
socket is either ''ON'' or ''OFF'' when the button is pressed. The ON-LED indicates the current state
of the socket.
- 8 -
Hasenbrink 4 32052 Herford Germany Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628

antrax Datentechnik GmbH
[email protected] - www.antrax.de
GSM
Getting Started
Parameter on the SIM card
The SIM card intended for the us with the AlarmBox-GSM can be prepared with any mobile phone
or PC SIM card reader.
The prepared SIM card should be inserted into the small slot on
the underside of the AlarmBox-GSM. The SIM card must be
inserted using a small tool (screwdriver or similar) and be
carefully pushed right up to the mechanical rear stop where it will
lock in this position. To later extract the SIM card it must be
pressed in again to the rear stop and then released. It will be
ejected by the push-pull card reader mechanism.
ACHTUNG: Before inserting/removing the SIM card ensure the AlarmBox-GSM is not connected
to the power supply (i.e. pull out of the wall outlet) otherwise the complete contents of the SIM
card not only the contents of the phone book could be destroyed. In this instance the SIM card
user will need to exchange the card with the provider which will incur further costs.
Standard-PIN:
As a general rule the use of a SIM card requires user to identify himself / herself with the PIN code.
The "AlarmBox-GSM" tries (if no PIN changes have been made) to log itself on using the standard
PIN code – please therefore use the standard PIN given below when first initialising SIM card.
The PIN is the access code for a SIM card. The AlarmBox-GSM expects the standard
PIN code '1357' to be used initially. This PIN code can be pre-set on the SIM card with
the help of a mobile phone or PC SIM card readers.
(Error code 2 see also Troubleshooting)
- 9 -
Hasenbrink 4 32052 Herford Germany Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628

antrax Datentechnik GmbH
[email protected] - www.antrax.de
GSM
Blinc codes of the GSM-LED:
The AlarmBox-GSM uses different flashing codes of the "GSM" LED to indicate the current
condition of the "GSM" module. If the "GSM" LED emits one of the flashing codes for an extended
period of time there may be an error as described below.
Basically the flashing codes are generated at each Power ON and during each GSM network login.
Normally however the individual error states are so short that the single Flashing Codes are not
perceivable. (e.g. the Flashing Code 2 during PIN setting lasts only approx. 0.3 second)..
GSM-
LED
Description If permanentl displa ed
1 x red Test of the GSM module Serious Basic Error. The GSM module is
probably defective
2 x red Initial Settings SIM card is not inserted or is defective the PIN
code is wrong or entry of the PUK is necessary
(see also Troubleshooting)
(CAUTION: Please check the PIN code on the
SIM card. If it is wrong further login attempts
can lead to the SIM card being blocked. (only 3
attempts are possible!)
3 x red Waiting to login to the GSM
network
No GSM network available (see also
Troubleshooting)
4 x red Enter GSM-Module
parameters
The entry "Own Phone Number" on the SIM
card is missing or the GSM module is damaged
6 x red No credit on the SIM Card (pre-paid SIM Card)
static
green
AlarmBox-GSM is registered (logged in) and ready to use
flashing
yellow
AlarmBox-GSM is receiving a voice call marks the ringing time and the whole
time of the connection(= during the complete call)
- 10 -
Hasenbrink 4 32052 Herford Germany Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628

antrax Datentechnik GmbH
[email protected] - www.antrax.de
Voice-Call →AlarmBox-GSM
Controlling the AlarmBox-GSM via Voice-Call
The AlarmBox-GSM can be controlled by authorized callers with the help of a voice call. A caller is
authorized if
He can identify himself with a correct access code
(i.e. after the AlarmBox-GSM answers incoming call the caller must enter the correct 4-
figure access code (figures only!) via the phone keyboard
Operation
The AlarmBox-GSM can be controlled from any telephone / mobile phone that is able to transmit
DTMF (Dual Tone Multi Frequency) tones. The AlarmBox-GSM answers the call after the 3rd ring.
A friendly female voice then asks the caller to enter the password. If this does not occur within two
minutes or an incorrect password is entered the connection is terminated. If the correct password
is entered the AlarmBox-GSM responds with an announcement that it is ready to receive
commands.
Every command input from the telephone keypad (in future referred to as "DTMF") always starts
with the character "*" (start of a command input) and ends with the character "#" (end of a
command input) comparable with "Return" or <CR> on a computer. The only exception to this is
the password login which is made without the characters "*" and "#"..
DTMF-Befehle :
Ke strokes Description
1357 Access Code Input (in this example "1357")
*0# Socket permanently OFF
*1# Socket permanently ON
*2# PC-Reset Command
i.e. switch outlet OFF waits 10 seconds switch ON again
*9# Ask for the SIM card credit (only for pre-paid SIM cards) otherwise an
Error Code will be transmitted
*20# Sends the status of the AlarmBox-GSM as an SMS to the subscribers
telephone number
- 11 -
Hasenbrink 4 32052 Herford Germany Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628

antrax Datentechnik GmbH
[email protected] - www.antrax.de
Voice-Call →AlarmBox-GSM
Responses from the AlarmBox-GSM when using Voice-Call
The AlarmBox-GSM contains an integrated audio response unit. After the acceptance of an
incoming call the AlarmBox-GSM transmits a greeting message and requests the input of the
password. If the correct password is recognised the AlarmBox-GSM responds with "Password
OK". If the password is incorrect it requests renewed input of the password.
Please do not press the telephone keys until the AlarmBox-GSM has finished its initial
announcement - only then the keystrokes will be registered.
Whilst entering the password the AlarmBox-GSM audibly responds with the recognised
keystrokes.
Normal response (correct password entered command mode active):
In stand-by mode (i. e. No key input) the current temperature is announced every
12 seconds.
After the recognition of an activation command (depressing the "*" key) the
announcement is muted until the "end" command (depressing the "#" key) is
recognised. With a valid command an appropriate message is transmitted and the
desired action is executed. An invalid command is acknowledged with ''command
was not recognised''. If after 5 seconds after pressing any key no further key or the
command end (= key #) is not recognised again it will acknowledged with
''command was not recognised''.
- 12 -
Hasenbrink 4 32052 Herford Germany Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628

antrax Datentechnik GmbH
[email protected] - www.antrax.de
Voice-Call →AlarmBox-GSM
Access code vs. PIN
The pre-set access code for the AlarmBox-GSM via Voice-Call is "1357". This means that as long
as this access code is not changed (using the telephone book entry "PWD" on the SIM card) the
pre-set access code will remain valid.
A new access code is stored in the phone book on the SIM card; this means that the access code is
resident on the SIM card - not in the AlarmBox-GSM!
The Access Code should not be confused with the PIN. The Access Code and the PIN are completely
independent of each other and can accept different values if the operator wishes. Apart from the
Default Value these two Codes have nothing in common:
PIN Login for use of the SIM card:
This login is required so that the AlarmBox-GSM can identify the SIM
card as a valid user (corresponds to the input of the PIN after turning
on a mobile by the user).
Default value:1357.
Zugangscode Access code for controllingt the AlarmBox-GSM-assembly from
outside:
Access code for the control of the AlarmBox-GSM:
The purpose of the access code is required in order to prevent
unauthorised callers from changing the configuration of the AlarmBox-
GSM.
May be changed using the phone book (MENU) entry "PWD" on the SIM
card.
A new access code is stored on the SIM card and in the configuration
memory of the AlarmBox-GSM
Default Value: 1357
Pre-paid – SIM cards
When using pre-paid SIM cards the AlarmBox-GSM regularly determines the credit remaining on
the SIM card. With a remaining credit of less than EUR 1 00 an alarm tone is switched on for the
first 5 seconds after the start of the voice call and the input of the valid access code by the
operator.
In this case the SIM card should be recharged. It is recommended that the SIM Card be recharged
remotely through the Service Provider so that the SIM card itself does not have to be removed or
physically taken out of the unit.
- 13 -
Hasenbrink 4 32052 Herford Germany Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628

antrax Datentechnik GmbH
[email protected] - www.antrax.de
SMS →AlarmBox-GSM
Controlling the AlarmBox-GSM via SMS
CAUTION: When controlling the AlarmBox-GSM via SMS please note that it can take up to 24
hours until an SMS reaches the AlarmBox-GSM. The delivery times vary greatly from provider to
provider. Inter-Network SMS often require much longer delivery times than network-internal SMS’.
(e.g. from T-Mobile to Vodafone).
Control of the AlarmBox-GSM by SMS is therefore only recommended for switching processes in
which the time of operation is not of over-riding importance.
The AlarmBox-GSM can only be operated with "a valid SMS". An SMS is valid when the sms text
begins with the correct access code "1357".
Operation
The following SMS types are differentiated:
Command-SMS – A command SMS is used to change parameters of the
AlarmBox-GSM. With the command SMS you can for example set the lower and
upper alarm temperatures or the alarming number. The SMS text should contain the
character ''='' after the command and then the requested value for example:
1357
voiceno=05 11 3456
Confirmation SMS
An confirmation-SMS can be sent by the AlarmBox-GSM as confirmation after the
execution of a command. The confirmation SMS is requested by the character "*"
within the SMS text e.g.:
1357
voiceno=05221123456 *
General rules for writing / mailing an SMS:
-Blanks are ignored.
-Case sensitivity is ignored.
-With mutually excluding commands within an SMS only the latest command is executed.
-When SMS are received "en-block" only the last command will be executed.
-After command execution all SMS stored in the device are deleted.
-See also Troubleshooting
- 14 -
Hasenbrink 4 32052 Herford Germany Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628

antrax Datentechnik GmbH
[email protected] - www.antrax.de
Command-SMS → AlarmBox-GSM
Text in the SMS Value Meaning
VoNo= or
VoiceNo=
-------------------
SMSNon=
(Command is for
n = 1-5)
Phone number Set voice-call or SMS number to be called in
case of an alarm.
Maximum one number for a voice call and
five numbers for a SMS notificaton can be
set.
VoNo= or
VoiceNo=
-------------------
SMSNon=
(Command is for
n = 1-5)
OFF Set voice-call or SMS number is deleted
VoNo= or
VoiceNo=
-------------------
SMSNon=
(Command is for
n = 1-5)
self Set phone number as voice-call or SMS
number from which the alarm is sent.
For this pupose call number
transmission shall not be suppressed.!
ltemp= (+/-)
temperature
Lower temperature limit. If this temperature
falls below an alarm is triggered.
htemp= (+/-)
temperature
Higher alarm temperature limit. If this
temperature shall exceed an alarm is
triggered.
ltemp= OFF Turn OFF lower temperature limit
htemp= OFF Turn OFF higher temperature limit
On! Switch ON socket permanently
Off! Switch OFF socket permanently
Reset! Trigger PC reset this means:
Turn OFF socket wait 10 seconds switch ON
socket (OFF wait 10 sec. ON)→ →
Status? or * AlarmBox-GSM – send status to the caller.
- 15 -
Hasenbrink 4 32052 Herford Germany Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628

antrax Datentechnik GmbH
[email protected] - www.antrax.de
AlarmBox-GSM – SMS Alarm Number→
Text in the SMS Meaning
AlarmBox-Wireless: Sender logo
20140327 Firmware version
Output: Current switching state of the socket
230V: State of the supply voltage
current temp.: Current determined temperature
Should the temperature sensor be defect and thus no
temperature can be detected the following text is sent:
''Temp.-Sensor: defect''
temp sensor: defect This text is only sent in case the temperature sensor is
defect instead of ''Akt. Temp.:''
lower/higher
temperature limit:
The minimum and maximum set alarm temperature limit
of the AlarmBox-GSM
Voice-No.: The set phone number that will be contacted in case of
an alarm
SMS-Non:
(gilt für n = 1-5)
Set SMS numbers in the AlarmBox-GSM that will be
contacted in case of an alarm.
Credit: Current credit on the SIM card. If the inserted card is
not a pre-paid card or if otherwise the credit can not be
requested the value "NA" is displayed.
This information may not be supported by all
(international) providers.
GSM: Signal strength
- 16 -
Hasenbrink 4 32052 Herford Germany Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628

antrax Datentechnik GmbH
[email protected] - www.antrax.de
Example of a AlarmBox-GSM - Status - SMS:
AlarmBox-GSM
20140327
Output: ON
230V: OK
Current temp.: 25 Grad
Lower temperature limit: -10 degrees
Higher temperature limit: 30 degrees
Voice-No.: 0522123456
SMS-No1: 0171123456
SMS-No2: 0172123456
SMS-No3: 0173123456
SMS-No4: 0174123456
SMS-No5: 0175123456
Credit: 13 59 EUR
GSM: -62dBm
The SMS is sent by the AlarmBox-GSM if it was requested
•via SMS with "status?"
•or within an command with ”*”
•or via DTMF with *20#
- 17 -
Hasenbrink 4 32052 Herford Germany Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628

antrax Datentechnik GmbH
[email protected] - www.antrax.de
Alarming
CAUTION: The alarming function is only active if a valid alarm phone number was stored to the
AlarmBox-GSM. Otherwise no alarming will occur! (see also: Operating the AlarmBox-GSM
via SMS)
An alarm is triggered in case of
•falling down or exceeding the set lower or higher alarm temperature limit
•outage of the 230V supply voltage
•a defect temperature sensor
Procedure in case of an alarm:
Two different alarm modes are involved.
•Alarming via Voice Call
◦In case of alarm a voice call is initiated to the stored voice number. This call must be
confirmed by entering *5# on the telephone keypad during the call to ensure that the
alarm call has not been taken by an answering machine or mailbox. If no answer or
acknowledgement is received the AlarmBox-GSM will repeat the process up to 10
times.
If no voice call number is stored no alarming via voice call is processed.
A maximum of one phone number can be stored.
•Alarming via SMS
◦the AlarmBox-GSM sends one Alarm-SMS in case of alarm to all stored SMS alarm
numbers.
A maximum of five SMS alarm numbers can be stored.
In general:
◦An alarm via voice call only occurs when the voice call has been set via the SMS
command. Only one alarm number for voice calls can be stored.
◦An alarm via SMS only occurs when the SMS number(s) has been set via the SMS
command. A maximum of five alarm numbers can be stored for SMS notification.
◦The alarm number for voice call and SMS can be identical this means in case of an
alarm both alarms are triggered via SMS and via voice call.
In this event the SMS alarm notification always comes first and then the voice call alarm
is started.
◦Upon acceptance of the voice call in case of an alarm triggered by the AlarmBox-GSM
the respective alarm reason is announced via voice message. This would be in the event
of a supply voltage failure „AlarmBox-GSM power supply outage!“. The alarm message
is repeated permanently.
- 18 -
Hasenbrink 4 32052 Herford Germany Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628

antrax Datentechnik GmbH
[email protected] - www.antrax.de
In order to avoid a permanent alarm ”loop” no other alarming because of the same alarm event is
triggered. Only after reset to ”normal state” the alarming function is again active. For example
after an outage of the power supply and the corresponding alarming any additional alarming is
stopped until the power supply is available again.
The same applies for the minimum and maximum temperature limit. If the limit has fallen below or
has been exceeded once and an alarm was triggered the temperature has to clearly be back within
''normal value'' before a new alarming can be triggered.
However alarming for other reasons is still possible.
If the socket is back to normal state this event is also reported to the alarm phone number.
Example for an AlarmBox-GSM - Alarm-SMS:
AlarmBox-Wireless
Power supply outage!
- 19 -
Hasenbrink 4 32052 Herford Germany Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628

antrax Datentechnik GmbH
[email protected] - www.antrax.de
Quick introduction
We recommend the following actions for a quick introduction to service:
1.) Controlling the Swit hBox-GSM via a landline or mobile phone:
The SIM card intended for use in the AlarmBox-GSM can be prepared in every mobile
phone or PC SIM card reader.
The PIN on the SIM card has to be "1357"
Carefully insert the SIM card (use a small tool i.e. screwdriver
or similar if necessary) up to the physical rear stop.
Insert in the AlarmBox-GSM into wall electrical socket outlet
The AlarmBox-GSM searches for a GSM network and tries to login ( →Blinkcodes)
If OK GSM-LED illuminates green→
After that the AlarmBox-GSM can be reached via landline or mobile phone.
The AlarmBox-GSM "answers" after 2 rings and informs about the current
temperature via voice message.
Now the AlarmBox-GSM can be operated as described under "Operating the AlarmBox -
GSM via SMS".
- 20 -
Hasenbrink 4 32052 Herford Germany Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628
This manual suits for next models
1
Table of contents
Popular Security System manuals by other brands

Clas Ohlson
Clas Ohlson 18-2447 quick start guide

TPAS
TPAS PX-100 manual

Assistive Technology Services
Assistive Technology Services SERVICE ANIMAL ALERT manual

Barnett Engineering
Barnett Engineering PRO TALK CV2 instruction manual

Integra
Integra BCR-S Mini G2 installation manual

Sentient
Sentient A17RQ user manual