anytronics Anyscene 512 Operating instructions

Units 5 & 6 Hillside Industrial Estate
London Road, Horndean,
Hampshire, PO8 0BL
Tel +44 (0)23 9259 9410
Fax +44(0)23 9259 8723
Page 1 of 13 AT1039 Issue 1
Anyscene 512 Operating
Instructions
Installation and Operation Guide for the Anytronics Anyscene 512 Scene Recall Unit
This equipment should only be installed by competent electricians, the responsibility for safe
and correct installation of the system rests with the installer and these notes are intended only
for guidance.
Contents
1. Overview and Operation .............................................................................................. 2
2. Mounting ...................................................................................................................... 2
3. Power Supply & Connection ........................................................................................ 3
4. DMX Requirements ..................................................................................................... 4
4.1. DMX Loading ........................................................................................................................ 4
4.2. DMX Wiring .......................................................................................................................... 4
4.3. Line Bias Network ................................................................................................................ 4
4.4. DMX Backup ......................................................................................................................... 4
5. Multiple Anyscene 512 ................................................................................................ 5
5.1. Commissioning ..................................................................................................................... 5
6. Configuration ............................................................................................................... 6
6.1. Auto Cycle Mode ................................................................................................................. 8
6.2. Master / Speed Settings ....................................................................................................... 8
6.3. Fade Rate ............................................................................................................................. 9
6.4. Clearing All Memories .......................................................................................................... 9
7. Programming ............................................................................................................. 10
7.1. Single Anyscene 512 .......................................................................................................... 10
7.2. Multiple Anyscene 512 ...................................................................................................... 10
8. External Scene Control ............................................................................................. 11
8.1. Pre-July 2018 Models ......................................................................................................... 11
8.2. Post-July 2018 Models ....................................................................................................... 12
9. Specification .............................................................................................................. 13

Units 5 & 6 Hillside Industrial Estate
London Road, Horndean,
Hampshire, PO8 0BL
Tel +44 (0)23 9259 9410
Fax +44(0)23 9259 8723
Page 2 of 13 AT1039 Issue 1
Anyscene 512 Operating
Instructions
1. Overview and Operation
The front panel has ten buttons and ten LED indicators. Switches labelled 1-7 have their
own blue mimic LEDs and are used for storing and recalling the contents of the 23
programmable memories.
The Up and Down buttons are normally used to control the Master level, allowing control
of the overall lighting level. They also provide access to the upper and lower memory
banks, each of eight scenes.
The green power LED shows when the unit is powered up, and the yellow data LED
indicates that the unit is receiving suitable programming data from a DMX source. Switch
0 is the blackout switch and when enabled the corresponding red LED will flash to indicate
the unit is in this mode.
The RJ45 sockets are on the back of the PCB along various option DIL switches and the
connectors for the external scene recall control.
The Anyscene 512 is also available with a reduced number of buttons for applications that
require less than the standard number of scenes. These include a 4-button version
allowing four user defined scenes to be programmed / recalled and a 5-button version that
also has the four user defined scenes, plus the blackout function / button of the standard
unit.
2. Mounting
The Anyscene 512 should be mounted using UK double pattresses with an approximate
depth of 32 mm.

Units 5 & 6 Hillside Industrial Estate
London Road, Horndean,
Hampshire, PO8 0BL
Tel +44 (0)23 9259 9410
Fax +44(0)23 9259 8723
Page 3 of 13 AT1039 Issue 1
Anyscene 512 Operating
Instructions
3. Power Supply & Connection
The Anyscene requires a +5V DC supply capable of suppling up to 50 mA. When using
multiple Anyscene 512 they should be linked together in series with each other and then
linked to the receiving equipment. (Anytronics dimmers or the AS180)
If used with other Anytronics equipment the required supply will be supplied through
the Cat5 cable and the system should be connected as follows,
If used with other equipment an AS180 PSU should be used to supply power to the
Anyscene and then provide connection to the wider DMX network as follows,

Units 5 & 6 Hillside Industrial Estate
London Road, Horndean,
Hampshire, PO8 0BL
Tel +44 (0)23 9259 9410
Fax +44(0)23 9259 8723
Page 4 of 13 AT1039 Issue 1
Anyscene 512 Operating
Instructions
4. DMX Requirements
4.1. DMX Loading
The maximum number of DMX receivers allowed along a single line is 32 devices without
the need for a buffer. If a DMX buffer is required within the system and multiple Anyscene
512s are being used the Anyscene’s must all be linked together in a daisy chain
configuration and then joined to the buffer for correct operation to the wider DMX line.
4.2. DMX Wiring
The DMX specification is based on the use of a single DMX source at one end of a twisted
pair with receiving equipment connected along the twisted pair, the final receiver must then
have the standard 120Ω termination resistor fitted. The use of multiple DMX sources in
one system (as with a multiple Anyscene 512 installation) is not directly covered by the
specification.
When connecting Anyscene 512 units into a DMX system the same topology should be
emulated by using a daisy chain connection from one end of the system to the other. The
DMX line should be linear from start to finish ideally with no branches or junctions.
Anyscene 512 units and receiving equipment may be placed in any order along the DMX
line, but the equipment at either end of this DMX line (whether receiving equipment or an
Anyscene 512) should have a termination resistor fitted for best results.
4.3. Line Bias Network
To ensure correct operation whether there are several or just one Anyscene 512 units in
the system, only one Anyscene 512 should have its line bias network set to ON.
4.4. DMX Backup
With the power applied, the Anyscene 512 will power up and, if no input DMX data is
detected within 2 seconds, it will start to output DMX data from the last used scene. If
another source of DMX data is detected in the system, the Anyscene 512 will instead
remain dormant in standby/receive mode capturing the current DMX data with start code
zero from channels 1-512.
Whilst in this mode, the yellow Data LED will remain illuminated if valid data is being
received at any of the decoded addresses. If the memory write protection (MWP) switch
is in the OFF position, this captured DMX data can be stored as scenes as per the
programming section of this document.
If the DMX source is then disconnected or fails, the yellow Data LED on the Anyscene 512
will be extinguished. After two seconds the Anyscene 512 will start to retransmit the last
received DMX data, providing a standby or DMX backup feature. None of the mimic LEDs
will be illuminated in this mode as the output data corresponds to the last data received
rather than to the contents of any of the scene memories.

Units 5 & 6 Hillside Industrial Estate
London Road, Horndean,
Hampshire, PO8 0BL
Tel +44 (0)23 9259 9410
Fax +44(0)23 9259 8723
Page 5 of 13 AT1039 Issue 1
Anyscene 512 Operating
Instructions
5. Multiple Anyscene 512
Up to four Anyscene 512 units can be used within the same DMX installation allowing
smooth transfer of control from one unit to another and providing control of DMX
installations from multiple locations.
Both this pushbutton unit and IR controlled Anyscene 512s may be mixed within the same
system and they may have the same scenes or different scenes stored in each unit.
In normal operation the last activated unit will take over control of the system and provide
the DMX data. After power up, the unit which was last in control of the system will restore
the last selected scene (or auto cycle). If any normal DMX source is connected to the
system, it will take over control of the system and force all the Anyscene 512 units into a
standby/receive state.
To ensure that the scene memory contents remain intact in such multiple unit installations,
it is vital that once scene programming has been completed, the MWP switches on all units
are moved to the ON position. If this is not done, then the units may reprogram each other
when attempting to recall scenes.
5.1. Commissioning
After programming the Anyscene 512s, first test the system by connecting each Anyscene
512 one at a time to check operation over the installed cabling. This is also the procedure
to be followed in case of encountering any problems with the installation to isolate the
problem area.
Once the wiring has been checked, build up the system by adding additional Anyscene
512 units in turn and checking that control of the DMX network is passed smoothly from
one Anyscene 512 to the other when the scene recall buttons are pressed.
The dormant Anyscene 512 units should have their data LEDs lit showing that they are
receiving DMX data from the active unit. The one active Anyscene 512 unit driving the
DMX system should have its data LED extinguished and a scene LED lit.

Units 5 & 6 Hillside Industrial Estate
London Road, Horndean,
Hampshire, PO8 0BL
Tel +44 (0)23 9259 9410
Fax +44(0)23 9259 8723
Page 6 of 13 AT1039 Issue 1
Anyscene 512 Operating
Instructions
6. Configuration
DIP Switch Settings
The age of the unit will determine the rear layout and the availability of the individual
external scene recall headers.
Pre-July 2018 Version
Eight Way DIL Switch (Bottom Side)
DIL No.
Name
Function
1
RFP
No Function
2 MWP ON = Internal memory protected, Normal Operation
OFF = Internal memory not protected, Programming Mode
3
+256
No Function
4
Master /Speed
See Section 6.2
5
Fade x2
See Section 6.3
6
Fade x4
See Section 6.3
7 EXT ON = Shorting the 2-way screw terminal advances to the next scene.
OFF = Shorting the 2-way screw terminal has no affect
8
LED ON = Front panel LED are bright
OFF = Front panel LED are dimmed
Two Way DIL Switch (Top Left)
DIL No.
Name
Function
1 Line Bias ON = Line Bias is used
OFF = Line Bias is removed from DMX line
2 Terminator ON = 120R Terminator across the DMX line
OFF = Terminator is not used

Units 5 & 6 Hillside Industrial Estate
London Road, Horndean,
Hampshire, PO8 0BL
Tel +44 (0)23 9259 9410
Fax +44(0)23 9259 8723
Page 7 of 13 AT1039 Issue 1
Anyscene 512 Operating
Instructions
Post-July 2018 Version
Eight Way DIL Switch (Bottom Side)
DIL No.
Name
Function
1 MEM ON = Internal memory protected, Normal Operation
OFF = Internal memory not protected, Programming Mode
2
Master /Speed
See Section 6.2
3
Fade x2
See Section 6.3
4
Fade x4
See Section 6.3
5
No Function
6 LED ON = Front panel LED are bright
OFF = Front panel LED are dimmed
7 Line Bias ON = Line Bias is used
OFF = Line Bias is removed from DMX line
8
Terminator ON = 120R Terminator across the DMX line
OFF = Terminator is not used

Units 5 & 6 Hillside Industrial Estate
London Road, Horndean,
Hampshire, PO8 0BL
Tel +44 (0)23 9259 9410
Fax +44(0)23 9259 8723
Page 8 of 13 AT1039 Issue 1
Anyscene 512 Operating
Instructions
6.1. Auto Cycle Mode
To enter the auto cycle mode both the Up and Down buttons should be held for at least
two seconds. On entering this mode, the yellow Data LED will be illuminated until the
buttons are released and the Anyscene 512 will start to cycle round scene memories 1-7
in ascending sequence. Whilst in auto cycle mode the levels and speed can be adjusted
as per section 4.2.
If the Anyscene 512 is powered down whilst in auto cycle mode, when powered up it will
recommence the auto cycle, starting from the scene memory in which it originally started
scene cycling.
Pressing any of the scene select buttons will terminate the auto cycle mode, and the
Anyscene 512 will fade to the selected scene. The unit will also exit auto cycle mode if an
external DMX source becomes active.
6.2. Master / Speed Settings
The Master / Speed DIL switch is used in conjunction with the auto cycle feature of the
Anyscene 512 and can be used to alter the duration and speed of the cycling. As supplied,
with DIL switch 4 set to OFF the default time spent in each scene is approximately 10
seconds
Master / Speed DIL OFF
The Up and Down buttons can be used to adjust the Master level in auto cycle
mode and the setting is reset to maximum when leaving auto cycle mode.
Master / Speed DIL ON
The Up and Down buttons can be used to adjust the cycle Speed in auto cycle
mode. The Up button will speed up the auto cycle and reduce the cycle period to
under 3 seconds. The Down button will reduce the auto cycle speed and increase
the scene cycle period to one minute. This altered setting will normally be
maintained whilst the unit is powered.
To save the adjusted master level and speed settings the following procedure should be
followed,
a) Set the Master Level as required
b) Set the Speed as required
c) Turn the MWP DIL off
d) Turn the Master / Speed DIL off
e) Turn the MWP DIL on
The current Master and cycle time settings are now saved as the power up default, and
Master / Speed DIL can be set to ON or OFF to allow push button control either of Master
level or auto cycle period as required. Note that any time Master / Speed DIL is moved
from ON to OFF with MWP DIL in the OFF position, the current Master level and cycle
speed will be saved as the new power up default.

Units 5 & 6 Hillside Industrial Estate
London Road, Horndean,
Hampshire, PO8 0BL
Tel +44 (0)23 9259 9410
Fax +44(0)23 9259 8723
Page 9 of 13 AT1039 Issue 1
Anyscene 512 Operating
Instructions
6.3. Fade Rate
The full-scale fade period from one scene to another can be adjusted using the two DIL
switches marked Fade x 2 and Fade x 4. The adjustment is as follows,
Fade x 2 Fade x 4 Fade Time (Seconds)
OFF OFF 2.5
OFF ON 5
ON OFF 10
ON ON 20
6.4. Clearing All Memories
To clear all saved scenes within the Anylight 512 the following procedure should be
followed,
a) With the power removed
b) Hold both the Up and Down level buttons
c) Power the unit whilst continuing to hold both buttons
d) If this operation has been successful, the Data LED on the Anyscene 512 will light
after approximately 4 seconds. It will cycle briefly on then off for 4 seconds until
the Up and Down level buttons are released.

Units 5 & 6 Hillside Industrial Estate
London Road, Horndean,
Hampshire, PO8 0BL
Tel +44 (0)23 9259 9410
Fax +44(0)23 9259 8723
Page 10 of 13 AT1039 Issue 1
Anyscene 512 Operating
Instructions
7. Programming
7.1. Single Anyscene 512
As supplied, the Anyscene 512 scene memories have a range of saved presets allowing
electrical contractors to confirm correct operation before final commissioning of the
system. They can be easily programmed from any source of DMX data including another
Anytronics scene memory, DMX lighting desk or a computerised lighting system. The
Anyscene 512 should be programmed whilst connected into the final installation and the
programming source should be connected into the system.
a) Turn the MWP DIL switch to ‘OFF’
b) Connect the DMX programming source (DMX Desk etc.) into the system
c) Power the DMX programming source
d) Power the Anyscene 512, the power and yellow data LED should be lit
e) Use the DMX programming source to adjust the required channels
f) Press and hold the button on the Anyscene 512 where the current scene should
be saved
g) The Anyscene 512 data LED will flash twice to show the data has been saved.
h) Repeat e) to g) for all required scenes
i) Once all scenes have bee saved turn the MWP DILL ‘ON’ to protect the recently
programmed scenes
Note: To access scenes 8 to 15 the down button should be held before the scene number
is pressed. To access scenes 16 to 22 the up button should be held before the scene
number is pressed.
Note: that unless the data LED is illuminated, and unless the internal MWP DIL switch is
in the OFF position, no programming of the scenes will be possible.
7.2. Multiple Anyscene 512
When programming a multi Anyscene 512 installation each unit should be connected into
the system individually and then programmed using the sequence of 7.1.
If all Anyscene 512 are to be programmed the same the following procedure should be
followed,
a) Program the first unit as per section 7.1
b) Keep the first unit powered and then insert the second unit into the system
c) Ensure the MWP of the second unit is off
d) Recall the required scene on the first unit
e) Press and hold the required scene location on the second unit
f) The data LED on the second unit should flash twice
g) Repeat d) to f) for all scenes
h) Remove the second unit from the system and turn MWP DIL switch for that unit
to ‘ON’
i) Repeat b) to h) for all subsequent Anyscene 512

Units 5 & 6 Hillside Industrial Estate
London Road, Horndean,
Hampshire, PO8 0BL
Tel +44 (0)23 9259 9410
Fax +44(0)23 9259 8723
Page 11 of 13 AT1039 Issue 1
Anyscene 512 Operating
Instructions
8. External Scene Control
8.1. Pre-July 2018 Models
The Anyscene 512 also has the ability to use external isolated closing contacts to cycle
round memories 1-7 in ascending sequence. The contacts should be connected to the
two screw terminals on the back of the Anyscene 512 PCB, and the EXT DIL switch should
be set to ON.
When the Anyscene 512 is in DMX output mode (and not when in auto cycle mode), the
next scene from the 1-7 scene cycle will be selected on each contact closure. To facilitate
‘debouncing’ of contact closure, contact closing inputs which occur less than two seconds
after the previous contact closure will be ignored.
As with the auto cycle mode, if the power is disconnected during this step cycling, when
the power is restored the cycle will be restarted from whichever scene was first in the cycle.
Whilst in step cycle mode, whichever scene is active, it can be overridden by pressing one
of the scene recall buttons. The next contact closure will cause the Anyscene 512 to step
on to the next scene after this manually recalled scene. The remote contacts can be
disabled by switching the EXT DIL switch to OFF.
When in auto cycle or standby/receive modes, all contact closures are ignored.

Units 5 & 6 Hillside Industrial Estate
London Road, Horndean,
Hampshire, PO8 0BL
Tel +44 (0)23 9259 9410
Fax +44(0)23 9259 8723
Page 12 of 13 AT1039 Issue 1
Anyscene 512 Operating
Instructions
8.2. Post-July 2018 Models
The post 2018 models have the ability to recall individual scenes using external zero-
voltage contacts and the bank of screw terminals provided on the rear of the unit, as
detailed in the following diagram,
Note: If the contact is held closed the Anyscene 512 will lock to the selected scene until
the contact is reopened.

Units 5 & 6 Hillside Industrial Estate
London Road, Horndean,
Hampshire, PO8 0BL
Tel +44 (0)23 9259 9410
Fax +44(0)23 9259 8723
Page 13 of 13 AT1039 Issue 1
Anyscene 512 Operating
Instructions
9. Specification
Supply:
o +5 V DC via Category 5 DMX cable from Anytronics Dimmer or AS180 PSU
Connections:
o DMX input/output via RJ45 connector
o Data received from DMX addresses 1-512
o Data output to DMX addresses 1-512
o Low voltage closing contact input for external scene recall
Controls:
o 8 scene selection buttons
o Master level up and down buttons
o External scene recall via low voltage contacts
Scenes:
o 23 stored scenes, each of 512 channels of DMX data
o 1 ’blackout’ scene with all outputs zero
Temperature Range: Ambient 0°C to 40°C
Dimensions: 148 x 86 x 15 mm, to be used with 25 mm UK double pattress
Weight: Net 0.14 kg
Country of Manufacture: UK
Compliance:
o Low Voltage Directive (2014/35/EU)
o WEEE (2012/19/EU)
o RoSH (2011/65/EU)
o CE
Warranty: 3 Year (Return to Base)
Table of contents
Other anytronics Controllers manuals
Popular Controllers manuals by other brands

Extech Instruments
Extech Instruments 48VFL instruction manual

Bosch
Bosch Rexroth CKL Series Commissioning

Samsung
Samsung MCM-A202DN installation manual

DINUY
DINUY PE K5X 002 instruction manual

ADLINK Technology
ADLINK Technology ROScube-X RQX-58 Series user manual

oventrop
oventrop REGTRONIC PC Instructions for installers