APART E-VOL20 User manual

WWW.APART-AUDIO.COM
Volume Control
OUTIN - 24V +
100Volt
100Volt
com
com
TOTAL LOUDSPEAKER POWER : 3 - 20 WATTS MAXIMUM !!!
USE ONLY HIGH IMPEDANCE
100VOLT LOUDSPEAKERS
E-VOL20
•Type : Euro
•Handling power : 20 watt
•Voltage : 100 Volt
•24V priority : Yes (20mA)
•Attenuation steps : 11 + “0”
•Build-in box : E-MODIN
•Build-on box : E-MODON
•Dimensions (H x W x D) : 80 x 80 x 70 mm
•Weight : 0.3 Kg
•Colour : white
Introduction
Please avoid
Tech. Specifications
The APart E-VOL20 is a 100 Volt volume control that can handle up to 20 watt of power.
It is very durable due to the step by step attenuation in 11 steps + zero position.
The volume control is equipped with a 24V priority relais. This way a microphone call will always come through at
maximum volume, no matter what position the volume control is in.
The E-VOL20 is build on a universal chassis that can easily be integrated with
Gira, Jung and Euro. Different cover plates are available for the UK market.
- Please avoid any power overload, measure your speakerlines before connecting.
- In reality, a lot of speakers have much higher load than the value listed in their specication.
Our APART speakers are especially engineered within their specication, so no risk for overload when using them !
- Please never apply clipped or overloaded levels from your amplier to this volume control.
It may cause overheating and damage ! Our APART ampliers are automatically limited to avoid such
distorted signals !
2-WIRE CONNECTION

WWW.APART-AUDIO.COM
Volume Control
OUTIN - 24V +
+ -
24V
100V
Microphone
100Volt
com
com
Amplifier
24Volt Priority output
• MA200
• MA200R
• MA200CDR
• MA125
• PA240P (only 30pcs)
e.g. You can use one of
these APart amplifiers
to connect up to 50pcs
volume controllers.
TOTAL LOUDSPEAKER POWER : 3 - 20 WATTS MAXIMUM !!!
USE ONLY HIGH IMPEDANCE
100VOLT LOUDSPEAKERS
4-WIRE CONNECTION WITH PRIORITY
What does a priority system do ?
When the volume controller is turned to 0 there is no background-music. (e.g. meeting room, office)
At this moment if there is a microphone call the information is lost.
With the priority system connected, the volume controller is set to maximum volume during the microphone call.
In this way there is no information lost.
To be able to use a priority system you need the following components :
- Volume controller with priority relay
- Amplifier with 24Volts priority output contact (24Volts / 1A : you can connect up to 50pcs of volume controllers)
- 4-wire cable connection
- Microphone (MICPAT-D)
E-VOL20
Please note that the volume control can also be used without this priority system or 24 V dc.
The priority system is often used for emergency announcements or to allow the paging come thru at maximum
level for a clear understanding.
As a standard, with jumpers set on 2-3 and 5-6, the relay will bypass the volume control to obtain maximum level
when 24Vdc is applied.
For special safety emergency applications with inverted operation mode,
the jumpers can be moved to 1-2 and 4-5.
In this case, 24Vdc and thus the relay will always be activated for normal operation with the volume control.
The volume control will be bypassed and set to its maximum as soon as the 24Vdc is cut off.
PRIORITY RELAY SYSTEM
100V
0V
0V
24V
N.C
N.O
1
2
3
4
6
5
J1
J2

WWW.APART-AUDIO.COM
Volume Control
OUTIN - 24V +
100Volt
100Volt
com
com
TOTAL LOUDSPEAKER POWER : 3 - 40 WATTS MAXIMUM !!!
USE ONLY HIGH IMPEDANCE
100VOLT LOUDSPEAKERS
E-VOL40
•Type : Euro
•Handling power : 40 watt
•Voltage : 100 Volt
•24V priority : Yes (20mA)
•Attenuation steps : 11 + “0”
•Build-in box : E-MODIN
•Build-on box : E-MODON
•Dimensions (H x W x D) : 80 x 80 x 70 mm
•Weight : 0.3 Kg
•Colour : white
Introduction
Please avoid
Tech. Specifications
The APart E-VOL40 is a 100 Volt volume control that can handle up to 40 watt of power.
It is very durable due to the step by step attenuation in 11 steps + zero position.
The volume control is equipped with a 24V priority relais. This way a microphone call will always come through at
maximum volume, no matter what position the volume control is in.
The E-VOL40 is build on a universal chassis that can easily be integrated with
Gira, Jung and Euro. Different cover plates are available for the UK market.
- Please avoid any power overload, measure your speakerlines before connecting.
- In reality, a lot of speakers have much higher load than the value listed in their specication.
Our APART speakers are especially engineered within their specication, so no risk for overload when using them !
- Please never apply clipped or overloaded levels from your amplier to this volume control.
It may cause overheating and damage ! Our APART ampliers are automatically limited to avoid such
distorted signals !
2-WIRE CONNECTION

WWW.APART-AUDIO.COM
Volume Control
OUTIN - 24V +
+ -
24V
100V
Microphone
100Volt
com
com
Amplifier
24Volt Priority output
• MA200
• MA200R
• MA200CDR
• MA125
• PA240P (only 30pcs)
e.g. You can use one of
these APart amplifiers
to connect up to 50pcs
volume controllers.
TOTAL LOUDSPEAKER POWER : 3 - 40 WATTS MAXIMUM !!!
USE ONLY HIGH IMPEDANCE
100VOLT LOUDSPEAKERS
4-WIRE CONNECTION WITH PRIORITY
•Keep the inside of the wallbox clear of all wires, this to prevent
short circuits between the wires in the wallbox and the
printed circuit of the volume controller.
• Don’t use solid copper conductor wires, the screw connectors
on the printed circuit board of the volume controller are designed
for flexible wires.
• Don’t connect more then one wire in each onboard screw
connectors of the volume controller.
• Don’t use force when mounting the volume controller in the
wallbox.
Mounting
What does a priority system do ?
When the volume controller is turned to 0 there is no background-music. (e.g. meeting room, office)
At this moment if there is a microphone call the information is lost.
With the priority system connected, the volume controller is set to maximum volume during the microphone call.
In this way there is no information lost.
To be able to use a priority system you need the following components :
- Volume controller with priority relay
- Amplifier with 24Volts priority output contact (24Volts / 1A : you can connect up to 50pcs of volume controllers)
- 4-wire cable connection
- Microphone (MICPAT-D)
E-VOL40

WWW.APART-AUDIO.COM
Volume Control
OUTIN - 24V +
100Volt
100Volt
com
com
TOTAL LOUDSPEAKER POWER : 3 - 60 WATTS MAXIMUM !!!
USE ONLY HIGH IMPEDANCE
100VOLT LOUDSPEAKERS
E-VOL60
•Type : Euro
•Handling power : 60 watt
•Voltage : 100 Volt
•24V priority : Yes (20mA)
•Attenuation steps : 11 + “0”
•Build-in box : E-MODIN
•Build-on box : E-MODON
•Dimensions (H x W x D) : 80 x 80 x 70 mm
•Weight : 0.3 Kg
•Colour : white
Introduction
Tech. Specifications
The APart E-VOL60 is a 100 Volt volume control that can handle up to 60 watt of power.
It is very durable due to the step by step attenuation in 11 steps + zero position.
The volume control is equipped with a 24V priority relais. This way a microphone call will always come through at
maximum volume, no matter what position the volume control is in.
The E-VOL60 is build on a universal chassis that can easily be integrated with
Gira, Jung and Euro. Different cover plates are available for the UK market.
2-WIRE CONNECTION
Please avoid
- Please avoid any power overload, measure your speakerlines before connecting.
- In reality, a lot of speakers have much higher load than the value listed in their specication.
Our APART speakers are especially engineered within their specication, so no risk for overload when using them !
- Please never apply clipped or overloaded levels from your amplier to this volume control.
It may cause overheating and damage ! Our APART ampliers are automatically limited to avoid such
distorted signals !

WWW.APART-AUDIO.COM
Volume Control
OUTIN - 24V +
+ -
24V
100V
Microphone
100Volt
com
com
Amplifier
24Volt Priority output
• MA200
• MA200R
• MA200CDR
• MA125
• PA240P (only 30pcs)
e.g. You can use one of
these APart amplifiers
to connect up to 50pcs
volume controllers.
TOTAL LOUDSPEAKER POWER : 3 - 60 WATTS MAXIMUM !!!
USE ONLY HIGH IMPEDANCE
100VOLT LOUDSPEAKERS
4-WIRE CONNECTION WITH PRIORITY
•Keep the inside of the wallbox clear of all wires, this to prevent short circuits between the wires in the wallbox
and the printed circuit of the volume controller.
• Don’t use solid copper conductor wires, the screw connectors on the printed circuit board of the volume con-
troller are designed for flexible wires.
• Don’t connect more then one wire in each onboard screw connectors of the volume controller.
• Don’t use force when mounting the volume controller in the wallbox.
Mounting
What does a priority system do ?
When the volume controller is turned to 0 there is no background-music. (e.g. meeting room, office)
At this moment if there is a microphone call the information is lost.
With the priority system connected, the volume controller is set to maximum volume during the microphone call.
In this way there is no information lost.
To be able to use a priority system you need the following components :
- Volume controller with priority relay (E-VOL60,E-VOL120)
- Amplifier with 24Volts priority output contact (24Volts / 1A : you can connect up to 60pcs of volume controllers)
- 4-wire cable connection
- Microphone (MICPAT-D)
E-VOL60

WWW.APART-AUDIO.COM
Volume Control
OUTIN - 24V +
100Volt
100Volt
com
com
TOTAL LOUDSPEAKER POWER : 3 - 120 WATTS MAXIMUM !!!
USE ONLY HIGH IMPEDANCE
100VOLT LOUDSPEAKERS
E-VOL120
•Type : Euro
•Handling power : 120 watt
•Voltage : 100 Volt
•24V priority : Yes (20mA)
•Attenuation steps : 11 + “0”
•Build-on box : E-MODON
•Dimensions (H x W x D) : 80 x 80 x 70 mm
•Weight : 0.3 Kg
•Colour : white
Introduction
Tech. Specifications
The APart E-VOL120 is a 100 Volt volume control that can handle up to 120 watt of power.
It is very durable due to the step by step attenuation in 11 steps + zero position.
The volume control is equipped with a 24V priority relais. This way a microphone call will always come through at
maximum volume, no matter what position the volume control is in.
The E-VOL120 is build on a universal chassis that can easily be integrated with
Gira, Jung and Euro. Different cover plates are available for the UK market.
2-WIRE CONNECTION
Please avoid
- Please avoid any power overload, measure your speakerlines before connecting.
- In reality, a lot of speakers have much higher load than the value listed in their specication.
Our APART speakers are especially engineered within their specication, so no risk for overload when using them !
- Please never apply clipped or overloaded levels from your amplier to this volume control.
It may cause overheating and damage ! Our APART ampliers are automatically limited to avoid such
distorted signals !

WWW.APART-AUDIO.COM
Volume Control
OUTIN - 24V +
+ -
24V
100V
Microphone
100Volt
com
com
Amplifier
24Volt Priority output
• MA200
• MA200R
• MA200CDR
• MA125
• PA240P (only 30pcs)
e.g. You can use one of
these APart amplifiers
to connect up to 50pcs
volume controllers.
TOTAL LOUDSPEAKER POWER : 3 - 120 WATTS MAXIMUM !!!
USE ONLY HIGH IMPEDANCE
100VOLT LOUDSPEAKERS
4-WIRE CONNECTION WITH PRIORITY
•Keep the inside of the wallbox clear of all wires, this to prevent short circuits between the wires
in the wallbox and the printed circuit of the volume controller.
• Don’t use solid copper conductor wires, the screw connectors on the printed circuit board of the volume
controller are designed for flexible wires.
• Don’t connect more then one wire in each onboard screw connectors of the volume controller.
• Don’t use force when mounting the volume controller in a wallbox.
Mounting
What does a priority system do ?
When the volume controller is turned to 0 there is no background-music. (e.g. meeting room, office)
At this moment if there is a microphone call the information is lost.
With the priority system connected, the volume controller is set to maximum volume during the microphone call.
In this way there is no information lost.
To be able to use a priority system you need the following components :
- Volume controller with priority relay
- Amplifier with 24Volts priority output contact (24Volts / 1A : you can connect up to 50pcs of volume controllers)
- 4-wire cable connection
- Microphone (MICPAT-D)
E-VOL120

WWW.APART-AUDIO.COM
Volume Control
E-VOLST
•Type : Euro
•Handling power : 2 x 40 watt
•Impedance : Minimum 2 x 4 Ohm
•24V priority : No
•Attenuation steps : 10
•Build-on box : E-2MODON
•Build-in box : NA
•Dimensions (H x W x D) : 80 x 80 x 76 mm
•Weight : 0.32 Kg
•Colour : white
Introduction
Tech. Specifications
The APart E-VOLST is a stereo volume control that can handle up to 2 x 40 watt in 4 ohm.
It can be used with a standard HiFi amplier to adjust the loudspeaker volume. It is very durable due to the step by
step attenuation in 10 steps.
The E-VOLST is build on a universal chassis that can easily be integrated with Gira, Jung and Euro.
Different cover plates are available for the UK market.
• Keep the inside of the wallbox clear of all wires, this to prevent short circuits between the wires in the wallbox and the
printed circuit of the volume controller.
• Don’t use solid copper conductor wires, the screw connectors on the printed circuit board of the volume
controller are designed for flexible wires.
• Don’t connect more then one wire in each onboard screw connectors of the volume controller.
• Don’t use force when mounting the volume controller in the wallbox.
Mounting

WWW.APART-AUDIO.COM
Volume Control
•MAX MUSIC POWER 40 WATT
•IMPEDANCE : 4-20 OHM
Do not connect a loudspeaker with an impedance lower than 4 ohm, this can permanently damage the unit
E-VOLST
Other manuals for E-VOL20
1
Table of contents
Other APART Control Unit manuals
Popular Control Unit manuals by other brands

Plymovent
Plymovent ICE-LC Product user manual

Hydra-Stop
Hydra-Stop Insta-Valve 250 Patriot installation instructions

Viessmann
Viessmann 5559 Supplementary manual

Swegon
Swegon CONDUCTOR user manual

Emerson
Emerson Keystone K-LOK H Series Installation, operation and maintenance instructions

Anybus
Anybus CompactCom 40 Common Ethernet Design guide