Volume Control
OUTIN - 24V +
100Volt
100Volt
com
com
TOTAL LOUDSPEAKER POWER : 3 - 20 WATTS MAXIMUM !!!
USE ONLY HIGH IMPEDANCE
100VOLT LOUDSPEAKERS
E-VOL20
•Type : Euro
•Handling power : 20 watt
•Voltage : 100 Volt
•24V priority : Yes (20mA)
•Attenuation steps : 11 + “0”
•Build-in box : E-MODIN
•Build-on box : E-MODON
•Dimensions (H x W x D) : 80 x 80 x 70 mm
•Weight : 0.3 Kg
•Colour : white
Introduction
Please avoid
Tech. Specifications
The APart E-VOL20 is a 100 Volt volume control that can handle up to 20 watt of power.
It is very durable due to the step by step attenuation in 11 steps + zero position.
The volume control is equipped with a 24V priority relais. This way a microphone call will always come through at
maximum volume, no matter what position the volume control is in.
The E-VOL20 is build on a universal chassis that can easily be integrated with
Gira, Jung and Euro. Different cover plates are available for the UK market.
- Please avoid any power overload, measure your speakerlines before connecting.
- In reality, a lot of speakers have much higher load than the value listed in their specication.
Our APART speakers are especially engineered within their specication, so no risk for overload when using them !
- Please never apply clipped or overloaded levels from your amplier to this volume control.
It may cause overheating and damage ! Our APART ampliers are automatically limited to avoid such
distorted signals !
2-WIRE CONNECTION
WWW.APART-AUDIO.COM
Volume Control
OUTIN - 24V +
+ -
24V
100V
Microphone
100Volt
com
com
Amplifier
24Volt Priority output
• MA200
• MA200R
• MA200CDR
• MA125
• PA240P (only 30pcs)
e.g. You can use one of
these APart amplifiers
to connect up to 50pcs
volume controllers.
TOTAL LOUDSPEAKER POWER : 3 - 20 WATTS MAXIMUM !!!
USE ONLY HIGH IMPEDANCE
100VOLT LOUDSPEAKERS
4-WIRE CONNECTION WITH PRIORITY
What does a priority system do ?
When the volume controller is turned to 0 there is no background-music. (e.g. meeting room, office)
At this moment if there is a microphone call the information is lost.
With the priority system connected, the volume controller is set to maximum volume during the microphone call.
In this way there is no information lost.
To be able to use a priority system you need the following components :
- Volume controller with priority relay
- Amplifier with 24Volts priority output contact (24Volts / 1A : you can connect up to 50pcs of volume controllers)
- 4-wire cable connection
- Microphone (MICPAT-D)
E-VOL20
Please note that the volume control can also be used without this priority system or 24 V dc.
The priority system is often used for emergency announcements or to allow the paging come thru at maximum
level for a clear understanding.
As a standard, with jumpers set on 2-3 and 5-6, the relay will bypass the volume control to obtain maximum level
when 24Vdc is applied.
For special safety emergency applications with inverted operation mode,
the jumpers can be moved to 1-2 and 4-5.
In this case, 24Vdc and thus the relay will always be activated for normal operation with the volume control.
The volume control will be bypassed and set to its maximum as soon as the 24Vdc is cut off.
PRIORITY RELAY SYSTEM
100V
0V
0V
24V
N.C
N.O
1
2
3
4
6
5
J1
J2

Other manuals for E-VOL20

1

Other APART Control Unit manuals

APART E-VOL60 User manual

APART

APART E-VOL60 User manual

APART E-VOL40 User manual

APART

APART E-VOL40 User manual

APART E-VOL120 User manual

APART

APART E-VOL120 User manual

APART E-VOL20 User manual

APART

APART E-VOL20 User manual

Popular Control Unit manuals by other brands

Solacom PAC user guide

Solacom

Solacom PAC user guide

Interlogix UltraSync UM-C-H1 Installation sheet

Interlogix

Interlogix UltraSync UM-C-H1 Installation sheet

Dametric BRM-DM1 user manual

Dametric

Dametric BRM-DM1 user manual

GMI D5090S Instruction & safety manual

GMI

GMI D5090S Instruction & safety manual

Pepperl+Fuchs IDENT-M System V MVI-F57-2HB12 manual

Pepperl+Fuchs

Pepperl+Fuchs IDENT-M System V MVI-F57-2HB12 manual

Alcad 912-DMH Quick programming guide

Alcad

Alcad 912-DMH Quick programming guide

Burkert 6213 operating instructions

Burkert

Burkert 6213 operating instructions

Omron C200H-MC221 - Operation manual

Omron

Omron C200H-MC221 - Operation manual

Flo-Tite F150 Installation operation & maintenance

Flo-Tite

Flo-Tite F150 Installation operation & maintenance

Measurement Computing miniLAB 1008 user guide

Measurement Computing

Measurement Computing miniLAB 1008 user guide

Keysight N7562A user guide

Keysight

Keysight N7562A user guide

Becker Centronic UnitControl UC42 Assembly and operating instructions

Becker

Becker Centronic UnitControl UC42 Assembly and operating instructions

Helvest FleX AB400 user manual

Helvest

Helvest FleX AB400 user manual

iseg EHQ Series Technical documentation

iseg

iseg EHQ Series Technical documentation

Truma VB 10 Operating instructions & installation instructions

Truma

Truma VB 10 Operating instructions & installation instructions

Straval PRH-04 FLG operating instructions

Straval

Straval PRH-04 FLG operating instructions

SolarEdge SPV 60MMJ Series installation guide

SolarEdge

SolarEdge SPV 60MMJ Series installation guide

SKUTCH EX-704 manual

SKUTCH

SKUTCH EX-704 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.