WWW.APART-AUDIO.COM
Volume Control
OUTIN - 24V +
100Volt
100Volt
com
com
TOTAL LOUDSPEAKER POWER : 3 - 20 WATTS MAXIMUM !!!
USE ONLY HIGH IMPEDANCE
100VOLT LOUDSPEAKERS
E-VOL20
•Type : Euro
•Handling power : 20 watt
•Voltage : 100 Volt
•24V priority : Yes (20mA)
•Attenuation steps : 11 + “0”
•Build-in box : E-MODIN
•Build-on box : E-MODON
•Dimensions (H x W x D) : 80 x 80 x 70 mm
•Weight : 0.3 Kg
•Colour : white
Introduction
Please avoid
Tech. Specifications
The APart E-VOL20 is a 100 Volt volume control that can handle up to 20 watt of power.
It is very durable due to the step by step attenuation in 11 steps + zero position.
The volume control is equipped with a 24V priority relais. This way a microphone call will always come through at
maximum volume, no matter what position the volume control is in.
The E-VOL20 is build on a universal chassis that can easily be integrated with
Gira, Jung and Euro. Different cover plates are available for the UK market.
- Please avoid any power overload, measure your speakerlines before connecting.
- In reality, a lot of speakers have much higher load than the value listed in their specication.
Our APART speakers are especially engineered within their specication, so no risk for overload when using them !
- Please never apply clipped or overloaded levels from your amplier to this volume control.
It may cause overheating and damage ! Our APART ampliers are automatically limited to avoid such
distorted signals !
2-WIRE CONNECTION
WWW.APART-AUDIO.COM
Volume Control
OUTIN - 24V +
+ -
24V
100V
Microphone
100Volt
com
com
Amplifier
24Volt Priority output
• MA200
• MA200R
• MA200CDR
• MA125
• PA240P (only 30pcs)
e.g. You can use one of
these APart amplifiers
to connect up to 50pcs
volume controllers.
TOTAL LOUDSPEAKER POWER : 3 - 20 WATTS MAXIMUM !!!
USE ONLY HIGH IMPEDANCE
100VOLT LOUDSPEAKERS
4-WIRE CONNECTION WITH PRIORITY
What does a priority system do ?
When the volume controller is turned to 0 there is no background-music. (e.g. meeting room, office)
At this moment if there is a microphone call the information is lost.
With the priority system connected, the volume controller is set to maximum volume during the microphone call.
In this way there is no information lost.
To be able to use a priority system you need the following components :
- Volume controller with priority relay
- Amplifier with 24Volts priority output contact (24Volts / 1A : you can connect up to 50pcs of volume controllers)
- 4-wire cable connection
- Microphone (MICPAT-D)
E-VOL20
Please note that the volume control can also be used without this priority system or 24 V dc.
The priority system is often used for emergency announcements or to allow the paging come thru at maximum
level for a clear understanding.
As a standard, with jumpers set on 2-3 and 5-6, the relay will bypass the volume control to obtain maximum level
when 24Vdc is applied.
For special safety emergency applications with inverted operation mode,
the jumpers can be moved to 1-2 and 4-5.
In this case, 24Vdc and thus the relay will always be activated for normal operation with the volume control.
The volume control will be bypassed and set to its maximum as soon as the 24Vdc is cut off.
PRIORITY RELAY SYSTEM
100V
0V
0V
24V
N.C
N.O
1
2
3
4
6
5
J1
J2

Other manuals for E-VOL20

1

Other APART Control Unit manuals

APART E-VOL60 User manual

APART

APART E-VOL60 User manual

APART E-VOL120 User manual

APART

APART E-VOL120 User manual

APART E-VOL40 User manual

APART

APART E-VOL40 User manual

APART E-VOL20 User manual

APART

APART E-VOL20 User manual

Popular Control Unit manuals by other brands

Fisher NotchFlo DST CL300 instruction manual

Fisher

Fisher NotchFlo DST CL300 instruction manual

Tyba Turn quick start guide

Tyba

Tyba Turn quick start guide

MS Sedco TDM installation instructions

MS Sedco

MS Sedco TDM installation instructions

Lutron Electronics GFS-5E Easy-to-follow Instructions

Lutron Electronics

Lutron Electronics GFS-5E Easy-to-follow Instructions

Sony FCB-EX780S Technical manual

Sony

Sony FCB-EX780S Technical manual

Frequency Central MU System X Lowpass Filter Build documentation

Frequency Central

Frequency Central MU System X Lowpass Filter Build documentation

Vimar by-me 01483 quick start guide

Vimar

Vimar by-me 01483 quick start guide

BHI NEDSP1061-KBD Installation and operating manual

BHI

BHI NEDSP1061-KBD Installation and operating manual

NI PXIe-4304 CALIBRATION PROCEDURE

NI

NI PXIe-4304 CALIBRATION PROCEDURE

roco 10727 manual

roco

roco 10727 manual

Honeywell RV277 installation instructions

Honeywell

Honeywell RV277 installation instructions

Goetze 451r Assembly and maintenance instructions

Goetze

Goetze 451r Assembly and maintenance instructions

Speck UL500P Series operating instructions

Speck

Speck UL500P Series operating instructions

Gascat ARGOS Installation, operation & maintenance manual

Gascat

Gascat ARGOS Installation, operation & maintenance manual

schmersal SRB301ST/PCV.2 operating instructions

schmersal

schmersal SRB301ST/PCV.2 operating instructions

H3C SecPath M9000-AI NSQM5AIASKA1 quick start guide

H3C

H3C SecPath M9000-AI NSQM5AIASKA1 quick start guide

Quonset Microwave QM2010-6000 quick start guide

Quonset Microwave

Quonset Microwave QM2010-6000 quick start guide

LG Innotek TWFM-B006D user manual

LG Innotek

LG Innotek TWFM-B006D user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.