APP Solar controller APP and PC monitoring User manual

1
Solar controller APP and PC
monitoring instruction manual
Ethernet monitoring mode
File No:
Version: V1.0
Description: This app is currently only available for device clients such
as Android phones.

2
Content
1. Description.....................................................................................................................................3
2. Software installation and hardware connection...................................................................... 3
2.1 Software installation.......................................................................................................... 3
2.2 Hardware connection........................................................................................................ 3
2.3 Device and Ethernet module connection.......................................................................3
3. APP account login........................................................................................................................ 4
4. GPRS mode connected device..................................................................................................4
5.Viewing device............................................................................................................................... 5
5.1 Viewing the running status of the device....................................................................... 5
5.2 Viewing Device Alarm Information.................................................................................. 6
5.3 View battery parameters...................................................................................................6
5.4 Viewing Load Parameters................................................................................................ 6
5.5Parameter setting................................................................................................................7
6. Chinese and English switching.................................................................................................. 7
7. PC monitoring device.................................................................................................................. 8
7.1 Photovoltaic background management system login.................................................. 8
7.2 Equipment parameter viewing......................................................................................... 8
7.3 Parameter settings...........................................................................................................10
7.4 Restore factory setting.................................................................................................... 10
Appendix 1:...................................................................................................................................... 10

3
1. Description
This instruction manual guides users how to use APP operation and PC monitoring
operation in WIFI mode, and view or set device parameters.
2. Software installation and hardware connection
2.1 Software installation
First put the CD-ROM attached to the controller into the CD-ROM drive of the
computer, then open the CD-ROM and copy the APP software installation package to the
Android system phone for installation (or the installation package provided by the relevant
personnel of our company)
Figure 2-1 APP installation interface
Note: At present, the APP is only installed and used on electronic devices such as
mobile phones of the Android operating system;
2.2 Hardware connection
Controller interface: using RJ45 interface (RS485 communication protocol):
Figure 2-2 RJ45 interface of the controller (RS485 communication protocol)
The controller device is connected to the WIFI module through a dedicated network
cable accessory to achieve WIFI mode communication;
2.3 Device and Ethernet module connection
Figure 2-3 Device and WIFI module connection

4
Note: After the Ethernet module and the dedicated wiring are connected, the two outer two
ends are respectively connected to the dedicated terminal of the controller and the dedicated
network cable of the Ethernet router.
Note:Router dedicated net wiring Crystal head blue sheath terminates the Ethernet router
equipment, black sheath terminates the dedicated wiring network port of the Ethernet
module
Note: Refer to Appendix 1 for Network Cable Fabrication;
3. APP account login
After the device wiring is completed, connect the battery terminal of the device to
the power supply. The green light of the power indicator of the Ethernet module lights up.
After opening the mobile phone APP, in the main interface of the device, click "My" in the
lower right corner to enter the account login interface. The account number and password
are both provided by the company.
Figure 3-1 Account login interface
4. GPRS mode connected device
After login, click the setting icon in the upper right corner of the main interface of the
app to enter the "System Settings" interface. Click "Communication Mode" to enter the
"Communication Settings" interface (Figure 4-1). "Management mode" means GPRS
mode. The default communication of APP is GPRS mode.
Figure 4-1 GPRS communication setting interface
After the communication method is set, exit to the APP main interface, select the type
of device to view, and enter the device list. At this time, the device list will display the
status of the added device and display the device online status in real time. When there

5
are a large number of managed devices, choose to look only at the online devices or
directly enter the device number to search (refer to Figure 4-3). For detailed viewing and
setting methods, please refer to below"Viewing Devices" .
Figure 4-2 Solar controller in GPRS mode as an example
5.Viewing device
When the device status in the device list is online, click to view the device details after
entering.
Figure 5 Device List
5.1 Viewing the running status of the device
Select any online device in the device list to enter the device details interface. The
device details interface displays the “Run Status” tab by default, including “Charging
Parameters”, “Load Parameters”, and “Device Parameters”. Viewing more" To view the
above three parameters and other information, you can also control the "Charge
Switching Machine" and "Load Switching Machine" through the above switches, and
refresh the data by the pull-down operation in the parameter area below.
Figure 5-1 Device Details - Running Status

6
5.2 Viewing Device Alarm Information
Click the “Alarm Information” tab to view the real-time alarm information of the device.
When the green circle after the alarm message turns red, it indicates an alarm. In the
parameter area below, the data is refreshed by the pull-down operation.
Figure 5-2 Device Details - Alarm Information
5.3 View battery parameters
Click the “Battery Parameters” tab to view the battery parameter setting information of
the device. Click the “Restore Factory Settings” button at the bottom of the interface to
restore the battery parameter settings of the controller to the factory state, and pull down
the operation in the parameter area below. To refresh the data.
.
Figure 5-3 Device Details - Battery Parameters
5.4 Viewing Load Parameters
Click the “Load Parameters” tab to view the load parameter setting information of the
device. Click the “Restore Factory Settings” button at the bottom of the interface to restore
the controller's load parameter settings to the factory state, and pull down the operation in
the parameter area below. To refresh the data

7
.
Figure 5-4 Device Details - Load Parameters
5.5 Parameter setting
The "battery parameter" and "load parameter" settings can be made in the device
details interface;
“Quick Settings”: The default power-on of the device is the number of lead-acid
batteries and the corresponding number of strings. To use other types of batteries, you
need to reset the battery type and the corresponding number of strings.
“Advanced Settings”: Here is an example of setting “overvoltage voltage”. First enter
the “Battery Parameters” interface, click on the “Overvoltage Voltage” line in the interface,
open the “Parameter Settings” interface, and the “Overvoltage Voltage” parameter value.
Enter the set value, such as "15", click the "Save Settings" button, automatically return to
the "battery parameter" interface, the "overvoltage" parameter has been set to save to 15V,
if the set value is not displayed, please refresh the view, if After the refresh, the
parameters have not changed. Please re-set the parameters again. The other parameters
are similar.
Figure 5-5 Parameter setting - overvoltage voltage setting
6. Chinese and English switching
Click the setting icon in the upper right corner of the APP homepage to enter the
“System Settings” interface. Click “Language” in this interface to enter the language
switching interface, select English or Simplified Chinese, and switch the interface to
English or Chinese.

8
Figure 6-1 Chinese and English display switching
7. PC monitoring device
7.1 Photovoltaic background management system login
Open the browser, enter the URL: http: 47.96.6.131: 8089 to enter the photovoltaic
background management system, enter the account number and password (the account
number and password are provided by the manufacturer), and click login to enter the
monitoring interface;
Figure 7-1 PC side login interface
7.2 Equipment parameter viewing
On the computer monitoring interface, click the device management on the right to
pop up the device list, and display all the device information of the device on the right:
including the device number, device address code, device type, belonging merchant,
belonging project, device status, etc. You can monitor the operating status of the device.

9
Figure 7-2 Device list interface
Click "device monitoring" on the right side of the information bar to enter the
"real-time parameters" interface. In this interface, we can view the operating parameters
and customer settings parameters. Only online devices can refer to their real-time
parameters. Click the refresh button in the lower right corner. Update the latest parameter
information of the device and click the back button to exit the real-time parameter
interface.
Figure 7-3 Operating parameters

10
Figure 7-4 Customer setting parameters
7.3 Parameter settings
Click the setting parameter on the right side of the device list information bar. In
the pop-up setting parameter interface, set the specific parameters by parameter type
and setting parameters. After setting, click the setting in the lower right corner to save it.
After finishing, click Back to exit the setting parameter interface ;
Figure 7-5 Parameter settings
7.4 Restore factory setting
On the right side of the device list information bar, click Restore leaving factory
settings to restore the parameter settings at the factory.
Appendix 1:
WIFI communication method wire production:
Table of contents
Popular Controllers manuals by other brands

Vimar
Vimar by-me 01417 quick start guide

Servomech
Servomech ATL 02 Installation, operation and maintenance manual

Baier
Baier PROMETHEUS Series instruction manual

Automationdirect.com
Automationdirect.com D4-454 PLC user manual

Tusa
Tusa PLATINA R-100 Technical manual

Festo
Festo VPPM-6TA-L-1-F-0L10H Assembly instructions