
Install the Netropy between two LAN segments
connected to Ports 1 and 2 as shown in the diagram.
(Some models include four separate pairs of ports, or
Emulation Engines, each of which acts as an independent
emulation system. Simply connect to each set of ports
and repeat these steps to set up each engine).
On the GUI, click on the arrow labeled “Unnamed Path”
to bring up the Path Configuration window. Change the
name of the path if desired.
On the left-side WAN Access column, configure the
bandwidth, background utilization, queuing, and other
parameters for packets entering the WAN from Port 1, and optionally, for packets inbound to the LAN from the WAN. On the
right-side WAN Access column, configure these parameters for packets entering and exiting the WAN from Port 2.
On the WAN column, set the Delay and Jitter, Loss, and other parameters for the traversal of the packets across the WAN
cloud or line.
When complete, press the Apply Changes button and close the Path Configuration window to return to the main screen. Press
the Emulation On button to start the Emulation Engine.
To emulate multiple paths, each with their own independent emulation parameters, click Add Path to create additional paths,
configure each path as described above, then click Packet Classifier to direct traffic onto individual paths by IP address range,
VLAN, or other packet identifier.
For additional details on installation or configuration, refer to the Netropy User’s Guide or click the Help link at the top of the
GUI.
PORT 1 PORT 2
Using the provided RJ45 to DB9 cable, connect the
serial port of a PC running terminal emulation software
to the CONSOLE port of the Netropy. Set the serial port
parameters to 9600 baud, 8 bits, no parity, 1 stop bit, and
disable flow control. For more details on connecting to the
serial console, see the Hardware Guide for your specific
model.
Press [ENTER] to display a login prompt. At the prompt,
log in as “admin”. Initially, there is no password.
netropy login: admin
Use the following commands to set the IP address,
netmask, and default gateway of the Netropy management
interface:
mgmt set addr <ip-address> netmask <mask>
IP addresses and subnet masks are entered in
dotted-decimal format. For example:
mgmt set addr 192.168.1.1 netmask 255.255.255.0
Once the management interface has been configured, use
an Ethernet cable to connect the MGMT port of the Netropy
to the management network. Open a browser and enter the
IP address of the MGMT interface in the address bar. The
Netropy End User License Agreement will be displayed.
Review the License Agreement. The Netropy GUI will be
displayed once the License Agreement is accepted.
IP Address Configuration via the Serial Console
Operation
For access to firmware upgrades, documentation, and other support materials, register your unit on-line at:
http://www.apposite-tech.com/register.html.
Copyright © 2005-2018 Apposite Technologies LLC. All rights reserved. Apposite and Netropy are registered trademarks of Apposite Technologies LLC.
The Apposite logo is a trademark of Apposite Technologies LLC.
P/N: DOC- QSG-N61-1b
REGISTRATION
MGMT
MGMT