Features
• NTSC and PAL video compatible
• Provides PreView range information on monitor as well as sensor status
• Provides audible indicator using existing camera microphone and monitor
speaker (if equipped)
• Optional audible indicator with an external buzzer
• Interfaces with CAN bus version of PreView sensors (High Resolution and
Xtreme)
• Interfaces with serial communication based PreView sensors
Compatibility
The PreView® VideoLink is compatible with all NTSC and PAL camera/monitor
systems. Preco currently offers a variety of adapter cables for camera/monitor
systems. Please contact Preco for available manufacturer options.
The PreView® VideoLink is compatible with the High Resolution PreView®
Sensor (HRPV4xxx), the Xtreme PreView® Sensor (XPV4xxx), the WorkZone
PreView® Sensor (WZPV5xxx), the WorkSight® PreView® (WS6xxx) and the
Waste industry version of the Standard PreView® (SPV2020-2xx).
Installation Instructions
Before Your Start
Prior to installing the PreView VideoLink, take time to familiarize yourself with
the installation instructions, theory of operation, and system components. At a
minimum, the following components are required for a system installation:
PreView VideoLink (1)
Camera Adapter Cable (not included with VideoLink)
Sensor Adapter Cable (not included with VideoLink)
Mounting Hardware
1-1/2” x 1/4” – 20 Bolts (2), 1/4” - 20 Nuts (2), 1/4” Washers (2),
1-1/2” x 1/4” – 20 Lag Bolts (2)
Mounting Location
The PreView VideoLink is required to be installed between the camera and the
camera/monitor cable. Depending on the application and cables purchased, the
VideoLink will need to be mounted either close to the reversing camera, or in the
cab near the monitor. See installation guide for more information.
VideoLink Mounting
1. Select the appropriate mounting location.
2. It is best to mount the box with the cable exits pointed down.
3. Use the box’s mounting holes as a template, scribe position marks through
the holes. Drill 5/16” (8mm) holes centered at the marks.
4. Secure the box to the vehicle with the two supplied 1/4-20 UNC bolts,
washers and nuts or equivalent. Alternately, the supplied lag bolts can be
used if the mounting conditions dictate. Apply a maximum torque of 50 inch
pounds when securing the box.