The iSys Digital remote control is a remote button which provides a secondary method of ‘Start/stop’ for iSys Digital
shower systems. When used with the iSys Digital diverter system, the remote can operate each outlet by pushing and
holding the ‘Start/stop’ button for a few seconds as required. The remote control may be sited inside the showering
area, as long as it is not subjected to continuous spray, or it can be sited outside the showering area – up to 10
metres from the Digital processor.
The iSys Digital remote control is not suitable for use with any other Aqualisa Digital product range.
THIS PRODUCT UST BE INSTALLED BY A CO PETENT PERSON IN ACCORDANCE WITH ALL RELEVANT CURRENT
WATER AND ELECTRICAL SUPPLY REGULATIONS.
ALL SHOWERS REQUIRING AN ELECTRICAL CONNECTION UST BE INSTALLED BY A QUALIFIED PERSON
FOLLOWING THE LATEST REVISION OF BS7671 (WIRING REGULATIONS) AND CERTIFIED TO CURRENT BUILDING
REGULATIONS.
This product is suitable for domestic use only.
This product is supplied complete with a 2 year guarantee.

iSys Digital rem te c ntr l installation instructions Page 5
Installation instructions
iSys Digital rem te c ntr l
In addition to the guide below it is essential that the written
instructions below are read and understood and that you have all
the necessary components (shown overleaf) before commencing
installation. Failure to install the product in accordance with these
instructions may adversely affect the warranty terms and
conditions. Do not undertake any part of this installation unless you
are competent to do so. Prior to starting, ensure that you are
familiar with the necessary plumbing regulations required to install
the product correctly and safely.
THE DIGITAL PROCESSOR UST BE ISOLATED FRO THE AINS
POWER SUPPLY PRIOR TO INSTALLING THE ISYS DIGITAL RE OTE
CONTROL.
!
F r use with single utlet iSys Digital sh wer systems
IF FITTING THIS PRODUCT WITH AN ISYS DIGITAL SINGLE
OUTLET SHOWER SYSTE , PLEASE FOLLOW THE FITTING
INSTRUCTIONS BELOW.
!

iSys Digital rem te c ntr l installation instructions Page 6
Using the back plate as a
template, mark the position of
the fixing screws and a Ø16mm
hole for the data cable entry
point. The cable entry point
should be made in the top right
hand corner of the back plate
recess, to ensure the two holes
are kept separate.
1
Wiring diagram
10m Data
Cable
10m Data
Cable
Prepare suitable wall fixings to accommodate no. 8 non-rusting
countersunk head screws of a suitable length (not included).
2

Pull the data cable through
before securing the back plate to
the wall using suitable no. 8 non
rusting countersunk screws.
4
Push the data cable plug into the
back of the button fully home to
ensure a water tight seal making
sure the seal is no longer visible.
5
iSys Digital rem te c ntr l installation instructions Page 7
Prepare a suitable route and install the 10m low voltage data
cable leaving a working end of at least 70mm including the
connector plug. The end of the data cable closest to the
processor should terminate at a maximum of 500mm from
the processor to allow for connection to the data cable
connection block.
3
DATA CABLES UST BE PROTECTED BY SUITABLE SHEATHING OR
CONDUIT IN THE EVENT OF SERVICING AND AINTENANCE.
!

iSys Digital rem te c ntr l installation instructions Page 8
Secure the button to the back plate
by carefully but firmly pushing the
button assembly onto the locking
clip at the bottom of the back
plate.
7
Locate the slot at the top of the
button assembly, onto the locating
peg at the top of the back plate
assembly, and lower the
button into position.
6
To release the button, insert a
small flat bladed screw driver into
the small slot at the bottom of the
button assembly, to release the
locking clip, taking care to avoid
damaging the plated surface.
Carefully lift the button out and
up off of the back plate top
locating peg.
!
BEFORE ANY ELECTRICAL ADJUST ENT IS ATTE PTED, THE
ELECTRICITY SUPPLY UST BE TURNED OFF AT THE AINS
SWITCH.
ELECTRICAL INSTALLATION AY ONLY BE CARRIED OUT BY
A QUALIFIED PERSON.
!

iSys Digital rem te c ntr l installation instructions Page 9
The Digital processor features a
secondary data cable socket next
to the main data cable connection
for use with the Digital remote
control secondary ‘Start/stop’
button. Carefully snap and remove
the entry pillar and connect the
cable to the socket as shown.
8
If using a Digital Divert system, the cable plugs into the diverter using
the splitter box provided.
If using with a Divert product, refer to the Digital Divert instructions
opposite.
!
Prior to commissioning the iSys Digital remote control following the
procedure overleaf, please refer to the installation instructions
provided with the main iSys Digital product to complete the
installation of the Digital processor.
9
IF FITTING THIS PRODUCT WITH AN ISYS DIGITAL DIVERT
SHOWER SYSTE , PLEASE FOLLOW THE FITTING INSTRUCTIONS
BELOW.
!
F r use with iSys Digital Divert systems

iSys Digital rem te c ntr l installation instructions Page 10
10m Data Cable
10m Data
Cable
Splitter box
2m Data Cable
Wiring diagram

iSys Digital rem te c ntr l installation instructions Page 11
Using the back plate as a template,
mark the position of the fixing
screws and a Ø16mm hole for the
data cable entry point. The cable
entry point should be made in the
top right hand corner of the back
plate recess, to ensure the two holes
are kept separate.
1
Prepare suitable wall fixings to accommodate no. 8 non-rusting
countersunk head screws of a suitable length (not included).
2
Prepare a suitable route and install the 10m low voltage data cable
leaving a working end of at least 70mm including the connector
plug. The end of the data cable closest to the splitter junction box
should terminate at a maximum of 500mm from the splitter
junction box to allow for connection to the data cable
connection block.
3
DATA CABLES UST BE PROTECTED BY SUITABLE SHEATHING OR
CONDUIT IN THE EVENT OF SERVICING AND AINTENANCE.
!
Pull the data cable through
before securing the back plate to
the wall using suitable no. 8 non
rusting countersunk screws.
4

iSys Digital rem te c ntr l installation instructions Page 12
Push the data cable plug into the
back of the button fully home to
ensure a water tight seal making
sure the seal is no longer visible.
5
Locate the slot at the top of
the button assembly, onto the
locating peg at the top of the
back plate assembly, and
lower the button into position.
6
Secure the button to the back
plate by carefully but firmly
pushing the button assembly
onto the locking clip at the
bottom of the back plate.
7

iSys Digital rem te c ntr l installation instructions Page 13
To release the button, insert a small
flat bladed screw driver into the
small slot at the bottom of the
button assembly, to release the
locking clip, taking care to avoid
damaging the plated surface.
Carefully lift the button out and
up off of the back plate top
locating peg.
!
BEFORE ANY ELECTRICAL ADJUST ENT IS ATTE PTED, THE
ELECTRICITY SUPPLY UST BE TURNED OFF AT THE AINS
SWITCH.
ELECTRICAL INSTALLATION AY ONLY BE CARRIED OUT BY
A QUALIFIED PERSON.
!
Plug one end of the 2m data
cable (supplied with the Digital
Diverter) into the open entry port
of the main processor box.
8
Plug the other end of the 2m
data cable (supplied with the
Digital Diverter) into p rt 2
on the Digital Diverter.
9

iSys Digital rem te c ntr l installation instructions Page 14
Plug the end of the attached data
cable feeding from the splitter box
into p rt 1 of the Digital Diverter.
10
Plug the end of the 10m low
voltage data cable feeding from
the main controller, as well as the
end of the 10m low voltage data
cable feeding from the remote
button, into the two side by side
entry ports on the splitter junction
box as shown.
11
PLEASE NOTE, THE 10 LOW VOLTAGE DATA CABLES CAN BE
PLUGGED INTO EITHER OF THE SIDE BY SIDE ENTRY PORTS OF
THE SPLITTER JUNCTION BOX, THIS WILL NOT AFFECT THE
OPERATION OF THIS PRODUCT.
!
Prior to commissioning the iSys Digital remote control following
the procedure overleaf, please refer to the installation instructions
provided with the main iSys Digital product to complete the
installation of the Digital processor.
12
iSys controllers are supplied with a temporary, clear protective film
on the controls, please remove film once the product has been
installed.
!

Aqualisa Products Limited
The Flyer’s Way
Westerham Kent TN16 1DE
Customer helpline: 01959 560010
Brochure Hotline: 0800 652 3669
Website: www.aqualisa.co.uk
Email: [email protected]
Republic of Ireland
Sales enquiries: 01-864-3363
Service enquiries: 01-844-3212
Part No:700982 Issue 01 Jan 14
Please note that calls may be recorded for training and quality purposes
The company reserves the right to alter, change or modify the product specifications without prior warning
® Registered Trademark Aqualisa Products Limited
Table of contents
Other Aqualisa Remote Control manuals