Aquapure MOP0.3-AD User manual

Medical Ozone Generator MOP0.3-AD
1
User’s Manual
MOP0.3-AD

Medical Ozone Generator MOP0.3-AD
2
Table of Content
Ozone Introduction ……………………………………1
Features and Specification ……………………………1
Structure and Accessories …………………………… 2
Installation and Usage ……………………………… 3
Application ……………………………………………4
Safety and Cautions ………………………………… 5
FAQ ……………………………………………………6
Maintenance Service …………………………………6
Warranty card …………………………………………7

Medical Ozone Generator MOP0.3-AD
1
I、Ozone Introduction
Ozone, O3, is a molecule that consists of three negatively charged oxygen atoms and is a normal constituent
of the earth’s atmosphere. Ozone itself is a distinctly blue coloured gas (bp – 111.9ºC) and is about one and a
half times heavier than air (density 2.144g/l).Ozone can be produced deliberately for a variety of industrial
purposes and medical therapy purposes. Ozone cannot be stored or transported in vessels because it falls back
into its original form (oxygen) after a while.
Medical ozone has highly pronounced bactericidal, fungicidal and virostatic properties, and is thus widely used
in disinfecting infected wounds, as well as in bacterially and virally produced diseases.
II、Features and Specification
1.
Feature
This Medical Ozone Generator is specially designed for medical treatments. It uses DOUBLE PURE
QUARTZ ELECTRODE technology, a new patent design that offers Ultra-pure Ozone and constant stable
ozone concentration output.
The DOUBLE PURE QUARTZ ELECTRODE technology makes sure that NO ANY metal, plastic, ceramic,
rubber, glues, etc., at the ozone generating area. The Only material for the ozone generating area is Pure
Quartz. The stain point of this pure quartz is 1110℃, and its soften point is 1670℃. This pure quartz is
100% ozone resistant, an ideal material for high frequency high voltage electrode. It makes Ultra-pure ozone
without any contaminants.
This Medical Ozone Generator delivers wide range for ozone concentrations from 2 up to 91 ug/mL (2~91
gamma) for many different uses. What’s more, it has been built in ozone destroyer inside for ozone off gas
treatment.
2.
Specification
Product Name
Medical Ozone Generator (with Ozone Destructor)
Model No.
MOP0.3-AD
Ozone Concentration:
2 ~ 91 ug/mL, Adjustable.(1 ug/mL = 1 gamma = 1 mg/L )
Connection of O2 Inlet & O3 Outlet
& Ozone Destructor Inlet
Standard Luer Lock Connector
Cooling System
4000 RPM , turbo brushless cooling fan
Ozone Module
DOUBLE PURE QUARTZ ELECTRODE technology
3 levels of ozone concentrations for each oxygen flow rate
Life
> 10,000 hours
Input Voltage
12V DC (100-240V AC to 12V DC adaptor)
Rated Power
<12W
Operating Temperature
-10℃ ~ 40℃
Storage Temperature
-20℃ ~ 70℃
Product Size(L x W x H)
228*176*80 mm
Package Box Size(L x W x H)
330 *230*150 mm
Weight
1.5 kg (if with oxygen tank regulator: 1.9 kg)
Accessories
1pc Adapter (100-240V AC input, 12V DC output); 1pc 3 way
connector; 3pcs male luer connectors; 1pc silicon tubing

Medical Ozone Generator MOP0.3-AD
2
3.
Ozone Concentration Table
Notice: The ozone concentration chart numbers might be slightly different. Just fefer to the chart on product itself.
III、Structure & Accessories
Accessories:
1pc * Power Adaptor / 1pc * 3 way connector / 3pcs * male luer connector / 1.5 meter * silicon tubing

Medical Ozone Generator MOP0.3-AD
3
IV、Installation and Usage
1. Take out the appliance and accessories from the package, put it on a flat ground in which space you are going to run
the appliance
2. Connect the oxygen source to the Oxygen Input connector (O2 IN)
3. Connect the 3 way connector to the Ozone Outlet (O3 OUT)
4. Cut a short piece of silicon tubing, add two male luer lock connectors to each end, then connect the side outlet of 3
way connector to the Ozone Destructor (O3 Destructor)
5. Adjust the 3 way connector, make sure the gas flow is from the Ozone Outlet (O3 OUT) to the Ozone Destructor
inlet (O3 Destructor) before switch on the applicance.
6. Connect the direct outlet of 3 way connector to the syringe or ozone bags, etc.
7. Plug in the 12V DC power adaptor to the Mains and the appliance. The background light for “OXYGEN FLOW”
column will turn ON when the power is connected successfully.
8. Slightly touch “POWER” on the button, the background light for the whole OZONE CONCENTRATION
CHART will turn ON. Then slightly touch I, II, or III on the button to choose the right ozone concentration and
the appliance starts working. A blue color light will be ON for indicating the ozone column that you choose.
9. Open the oxygen source, and adjust the oxygen flow rate to get the ozone concentration according to the Ozone
Concentration Table.
10. Adjust the 3 way connector, make the gas flow to the syringe or ozone bags, etc.
11. After collecting the ozone, adjust the 3 way connector, make the gas flow back to the Ozone Destructor (O3
Destructor) again.
12. Slightly touch “POWER” on the button to turn off the appliance.
13. Close the oxygen source
14. Unplug the appliance.
NOTE: for making ozone drinking water, it does not need the 3 way connector. Just connect the O3 OUTPUT to the
ozone glass cup inlet directly, and connect the ozone glass cup outlet to the O3 destructor.
112V DC power inlet
2Power distributor board
3Oxygen source inlet
4Ozone outlet
5Ozone Generating Module
6Ozone destructor inlet
7Ozone destructor
8Turbo cooling Fan
9Ozone Concentration Chart
10 Finger touch button

Medical Ozone Generator MOP0.3-AD
4
V、Applications
Ozone Joint Injection
Ozone Blood Treatment
Ozone for Rectal Insufflation
Gynecological ozone therapy
Ozone Dental
Ozone Drinking Water
Ozone Ear Insufflation
Ozone for Wound Healing

Medical Ozone Generator MOP0.3-AD
5
Ozone for making Ozone Oil
Ozone Sauna
Ozone for Lyme disease treatment
Ozone for Cancer treatment
VI、Safety and Cautions
1. Make sure that all accessories are attached in the box and the appliance is in good condition when it is
received. Always keep the appliance vertical on the flat ground.
2. Do not store the appliance in a humid place.
3. Do not clean this appliance using a damp cloth when it is working
4. Operate the appliance in a precondition within 0℃~ 40℃& 0 ~ 70% RH
5. Do dis-connect the adapter before opening the product or any maintenance.
6. It is not recommended to switch on & off frequently on this appliance. To avoid any defective, please
re-switch on the appliance at least 1mins after switching off.
7. Do not block the ventilated fan and outlet of the appliance all the time.
8. Turn off this appliance and unplug the adapter immediately when there is ozone leakage inside the
housing. A space with ventilation is preferable to stay when this happens.
9. It is not preferable to operate the appliance in flammable or explosive places.Do be more careful if it is
necessary.
10. Do not allow water go into the appliance.
11. Pack the appliance into a box if it is not going to use for a long while

Medical Ozone Generator MOP0.3-AD
6
VII、FAQ
Queries
Answers
Power indication light doesn’t
turn ON after plugging the adapter
to the mains power socket (only
first column “OXYGEN FLOW”
should be ON
a. if the adapter is well connected to the appliance or not
b. if the indication light of the adapter on or off
c. if the adapter is in good condition or not
d. unplug the adapter and open the appliance, check if the wire of
power connector is in good condition or not
e. ask for help from whom is responsible for
No ozone comes out when the
appliance is on, and the power
and ozone indication light is on
as well
a. if the air source has been connected and be offered to make ozone
b. the fan is working or not
c. unplug the adapter and open the appliance, check if the connection
inside is in good condition or not
d. if the quartz tube of the ozone generator module is broken or
not
e. change the ozone generator module or ask for help from whom is
The ozone smell is very strong
around the appliance
a. If the ozone outlet connectors are connected well
b. If the ozone destructor be connected properly
c. If the ozone destructor need replacements
Who is allowed to operate
the appliance
People who are trained or with relative knowledge of ozone appliance is
allowed to operate or repair it
VIII、Maintenance Service
1. This Medical Ozone Generator is warranted to be free from all defects in material in normal ozone therapy use for
a period of (1) year from date of purchase.
2. The warranty is guaranteed only to the original purchaser and members of his or her immediate household. The
warranty is subject to the following provisions. Any damages or malfunctions caused by negligence, abuse, or
not operate in accordance with the User’s Manual are not covered by this warranty. Also, any defects or
damages caused by unauthorized service or the use of other than Genuine parts are not covered.
3. YOUMO AQUAPURE will, at its option, repair or replace a defective ozone generator or part(s) for the unit that
is covered by this warranty. As a matter of warranty policy, YOUMO AQUAPURE will not refund the
customer’s purchasing price. Please recorder the following Warranty Card when you purchase the unit from our
company or the distributor.
4. To obtain warranty service you must return the defective ozone generator or its parts along with proof of
purchasing to our company or any Authorized Warranty Station. All transportation charges on parts, or units,
submitted under this Warranty shall be borne by purchaser.
IX、Warrenty card
Customer Name
Model No.
Purchase Date
Serial No.
Customer Address
Customer Phone
Table of contents
Other Aquapure Air Cleaner manuals