User Notice
The power supply for all water tanks or hot water generators must be unified.
Prohibit installing the wired controller at wet or sunshine places.
Do not knock, throw or frequently disassemble the wired controller.
Do not operate the wired controller with wet hands.
When two wired controllers control one (or more) water tank or hot water
generator(s), the address of wired controller should be different.

Contents
1 DISPLAY................................................................................1
1.1 LCD of Wired Controller.......................................................................1
1.2 LCD Display Instruction .......................................................................2
2 BUTTONS..............................................................................4
2.1 Button Graphics ...................................................................................4
2.2 Function Instruction of Buttons ............................................................4
3 Installation and Commissioning.............................................5
3.1 Installation of Wired Controller.............................................................7
3.2 Commissioning...................................................................................14
4 Operation Instructions..........................................................22
4.1 Switch between Water Heating & Floor Heating Interfaces...............22
4.2 Water Heating ON/OFF......................................................................23
4.3 Water Heating Mode Setting..............................................................24
4.4 Water Heating Temperature Setting...................................................25
4.5 Function Switchover of Water Heating...............................................26
4.6 Sun-flower Setting..............................................................................27
4.7 Water Temperature Auto Setting Function of Water Heating.............28
4.8 High-temp Sterilization Setting...........................................................28
4.9 Setting of Rapid Water Heating .........................................................34
4.10 Timer Setting of Water Heating........................................................34
4.11 Preset water heating setting.............................................................40
4.12 Floor Heating ON/OFF.....................................................................44
4.13 Water Temperature Setting of Floor Heating ...................................44
4.14 Function Switchover of Floor Heating..............................................45

4.15 Water Temperature Auto Setting Function of Floor Heating ............46
4.16 Setting of Rapid Floor Heating.........................................................46
4.17 Absence Setting of Floor Heating ....................................................47
4.18 Timer Setting of Floor Heating.........................................................47
4.19 Clock Setting....................................................................................52
4.20 Clean Setting....................................................................................54
4.21 Remote Shield Function...................................................................54
4.22 Child Lock Function .........................................................................55
5. ERROR DISPLAY...............................................................56
5.1 Table of Error Codes for Outdoor Unit ...............................................57
5.2 Table of Error Codes for Water Tank or Hot Water Generator...........60
5.3 Table of Debugging Codes.................................................................61
5.4 Table of Status Codes........................................................................62

Wired Controller XK57
1
1 DISPLAY
Fig 1.1 Appearance of the Wired Controller
1.1 LCD of Wired Controller
Fig1.2 LCD graphics of wired controller

Wired Controller XK57
2
1.2 LCD Display Instruction
Table 1.1 LCD display instruction
No.
Displaying name
Instructions
1
WATER interface
arrow
The icon will light up when the current wired controller is at the
interface of hot water function.
2
WATER ON/OFF
Overview of the hot water function: the WATER icon keeps on; the
ON/OFF icon is displayed according to the on or off status of hot
water function.
3
Standard hot water
Standard hot water mode
4
Preset
Preset hot water mode;
5
Available hot water
The proportion of available hot water for the current user is displayed
according to the state in the frame for available hot water; it is
displayed only at the interface for hot water;
6
Night
Night hot water mode;
7
Sun-flower
It is displayed when the SUN-FLOWER function is valid;
8
Temperature Zone
Set water temperature/actual water temperature is displayed.
9
Auto
It’s displayed when the function of water temperature auto setting is
valid. This function can be set separately under water heating or floor
heating and the icon is displayed according to whether the function
under the respective interface is valid or not.
10
Sterilize
The icon will light up when the STERILIZE function is valid and will be
blinking under sterilization.
11
Rapid
It’s displayed when the RAPID function is valid. This function can be
set separately under water heating or floor heating and the icon is
displayed according to whether the function under the respective
interface is valid ornot.
12
Clean
The icon will light up when the CLEAN function is valid and will be
blinking under cleaning status.
13
Absence
It’s displayed when the ABSENCE function is valid.

3
No.
Displaying name
Instructions
14
No.
When inquiring or setting project number of water tank or hot water
generator, icon "NO." is displayed;
15
Group
It is displayed when one wired controller controls multiple water tanks
or hot water generators simultaneously;
16
Set
Display icon “SET” under parameter setting interface
17
Sub-controller
It indicates that the current wired controller is a slave wired controller
(address of wired controller is 02);
18
Check
Display icon "CHECK" under parameter view interface
19
FLOOR interface
arrow
The icon will light up when the current wired controller is at the
interface of floor heating function.
20
FLOOR ON/OFF
The icon for floor heating keeps on; the ON/OFF icon is displayed
according to the on or off status of floor heating.
21
E-heater
The icon indicates whether the auxiliary electrical heating is on.
22
Defrost
Outdoor unit defrosting status;
23
Cycle
Running status of the back water pump.
24
Anti-freeze
Anti-freezing status.
25
keep
Running status of the water tank/hot water generator.
26
Heat up
Running status of the water tank/hot water generator.
27
solar
It is displayed when the hot water generator is connected to solar
energy;Flicker when solar power is on work.
28
MODE CONFLICT
When unit is in cool/dry mode, floor heat is not allowed to turn on.
Mode Conflict will be flickering.
29
Shield
Shielding status.
30
Child lock
Child lock status.
31
Timer zone
Display the system clock and timer status.
32
Invalid operation
Display invalid operation.
Note:
When wired controller is connected with different water tanks or hot water generators, some functions
will be different.
Wired Controller XK57

Wired Controller XK57
4
2 BUTTONS
2.1 Button Graphics
Fig. 2.1 Button graphics
2.2 Function Instruction of Buttons
Table 2.1 Function instruction of buttons
No.
Buttons
Instructions
1
Enter/
Cancel
Select and cancel function
3
Decrease
(1)Set water temperature for water heating, floor heating and high
temperature sterilization;
(2) Set timer (water/floor heating), preset water heating time and
sterilization time;
(3) Set and inquire parameter
7
Increase
4
Mode
Under the interface of water heating, 3 modes can be switched: standard

5
water heating, preset water heating and night water heating. (Note: modes
cannot be switched under the interface of floor heating)
5
Function
WATER interface: sun-flower function, water temperature auto function of
water heating, sterilize function, rapid water heating function;
FLOOR interface: water-temperature auto function of floor heating,
absence function, rapid floor heating function
2
Timer
Timer setting
8
ON/OFF
water/floor heating ON/OFF
6
WATER/AC/FLO
OR
Switchover between water heating and floor heating interfaces (only when
water heating and flooring heating functions are both valid).
7
and
3
Child lock
Activate or cancel the child lock by long-pressing the “increase” and
“decrease” buttons for 5 seconds
3 Installation and Commissioning
There’re two kinds of installation plate. As for the installation plate for different
editions of wired controller, the first of installation plate style is selected for example.
The first style: Unit: mm
Wired Controller XK57

Wired Controller XK57
6
The second style: Unit: mm
Fig. 3.1Dimension of wired controller
Fig. 3.2 Parts of wired controller
No.
1
2
3
4
Name
Panel of wired
controller
Screw M4×25
Soleplate of wired
controller
Junction box mounted in
the wall space
Qty
1
2
1
Parts supplied by users

7
3.1 Installation of Wired Controller
3.1.1 Communication Line Selection
Fig. 3.3 Length of communication line
Wire material
type
Total length of
communication line
between water tank or
hot water generator
and wired controller
L(m)
Wire
size
(mm2)
Material
standar
d
Remarks
Light/Ordinary
polyvinyl
chloride
sheathed cord.
(60227 IEC 52
/60227 IEC 53)
L≤250
2×0.75~
2×1.25
IEC
60227-5:2
007
1.Total length of communic
-ation line can’t exceed 250m.
2.The cord shall be Circular
cord (the cores shall be
twisted together).
3. If unit is installed in places
with intense magnetic field or
strong interference, it is
necessary to use shielded wire.
Wired Controller XK57

Wired Controller XK57
8
Note:
①If the air conditioner is installed at the strong electromagnetic interference
place, communication line of the wired controller must use shielding twisted
pair.
②Materials of communication line for wired controller must be selected
according to this ins-truction manual strictly.
3.1.2 Installation requirements
(1)Prohibit installing the wired controller at wet places.
(2)Prohibit installing the wired controller at direct sunshine places.
(3)Prohibit installing the wired controller at the place near high temperature
objects or water-splashing places.
3.1.3 Wiring Requirements
There are four network wiring methods between the wired controller and the water
tank/hot water generator:

9
Fig.3.4 Fig.3.5
Fig.3.4 One wired controller controls one water tank or hot water generator.
Fig.3.5 Two wired controllers control one water tank or hot water generator.
Wired Controller XK57

Wired Controller XK57
10
Fig. 3.6 One wired controller controls multiple water tanks or hot water generators
simultaneously.

11
Fig. 3.7 Two wired controllers control multiple water tanks or hot water generators
simultaneously.
Wiring instructions:
①When one wired controller controls multiple water tanks or hot water
generators simultaneously, the wired controller can connect to any one water
tank or hot water generator, but the connected ones must be either water
tanks or hot water generators. The total quantity of water tank or hot water
generator controlled by wired controller can't exceed 3 sets, and the
connected water tank or hot water generator must be within the same
network.
Wired Controller XK57

Wired Controller XK57
12
②When two wired controllers control one water tank or hot water generator,
the addresses of those two wired controllers should be different. Please refer
to 3.2.2 Parameter Setting.
③When two wired controllers control multiple water tanks or hot water
generators simultaneously, they can connect to any one water tank or hot
water generator, but the connected ones must be either water tanks or hot
water generators. The addresses of those two wired controllers should be
different. Please refer to 3.2.2 Parameter Setting. The total quantity of water
tank or hot water generator controlled by wired controller can't exceed 3 sets,
and the connected water tank or hot water generator must be within the
same network.
④When one (or two) wired controller(s) control (s) multiple water tanks or hot
water generators at the same time, the controlled water tanks or hot water
generators should have the same setting.
⑤Network connection of wired controller and water tank or hot water
generator must be according to one of the four wiring methods as shown in
fig 3.4-3.7 As for the connection method shown in fig 3.5 and 3.7, there
should be only one master wired controller (address is 01) and one slave
wired controller (address 02). The quantity of wired controller can't exceed
two.

13
3.1.4 Installation
Fig. 3.8 Installation diagram for wired controller
Fig. 3.8 is the simple installation process of wired controller; please pay attention
to the following items:
(1)Before installation, please cut off the power for water tank or hot water
generator.
Wired Controller XK57

Wired Controller XK57
14
(2)Pull out the two-core twisted pair from the installation hole on wall, and then
pull this wire through the connecting hole at the rear side of soleplate of wired
controller.
(3)Stick the soleplate of wired controller on the wall and then use screw M4×25 to
fix the soleplate and installation hole on wall together.
(4)Connect the two-core twisted pair to wiring column H1 and H2 respectively
and then tighten up the screws.
(5)Bundle panel and soleplate of wired controller together and the installation is
completed.
3.1.5 Disassembly
Fig. 3.9 Disassembly diagram of wired controller
3.2 Commissioning
3.2.1 Parameter Enquiry
Unit parameters can be checked in unit on or off status.

15
(1)Long press “FUNCTION” button for 5s to enter the interface of parameter
enquiry. “C00” is displayed in the temperature zone and the icon “CHECK”
lights up;
(2)Press “▲” or “▼” button to select parameter code;
(3)Press “ENTER/CANCEL” button to return to the previous step until system
exits parameter enquiry.
The parameter enquiry list is as following:
Table 3.1 Parameters viewing list
Parameter
code
Parameter
name
Parameter
range
Viewing method
C00
Entrance of
adjustable
parameter
-
In “C00” status, Timer zone shows the current water tank or
hot water generator project number. When one wired
controller is controlling multiple water tank or hot water
generator units, then only the smallest project number will
be displayed.
C01
View the
project
number and
locate the
faulted water
tank or hot
water
generator
1-255:
project
number of
online
water tank
or hot
water
generator
Operation method:
Enter viewing: press “MODE” button in “C01” status to enter
the interface of project number of water tank or hot water
generator. Press “▲” or “▼” button to switch codes between
water tank and hot water generator.
Display method :
Temperature zone: malfunction of the current water tank/hot
water generator (only the malfunction of water tank/hot
water generator is displayed. The temperature zone will
display the breakdown in turn with an interval of 3 seconds if
there are several malfunctions)
Timer zone: (C5 malfunction of project number conflict)
/project number of the current water tank or hot water
Wired Controller XK57

Wired Controller XK57
16
generator
Note:
System will not exit “C01” viewing automatically. User has to
exit this interface manually.
C03
View the
quantity of
Aircon unit,
water tank and
hot water
generators in
the system.
1-80
Timer zone: display the quantity of indoor units within the
system (including Aircon unit, water tank and hot water
generator)
C06
View priority
operation
00: normal
operation
01: priority
operation
Operation method:
Enter viewing: press “MODE” button in “C06” status to enter
the interface of viewing priority operation. Press “▲” or “▼”
button to select water tank or hot water generator.
Display method:
Temperature zone: display project number of current water
tank or hot water generator;
Timer zone: display setting value of priority operation of
current water tank or hot water generator.
C09
View address
of wired
controller
01,02
Timer zone: display the address of wired controller
C11
View the
quantity of
water tank or
hot water
generator in
the case that
one wired
controller
controls
1-3
Timer zone: display the quantity of water tank or hot water
generator controlled by the wired controller
Table of contents
Languages:
Other aquatermic Controllers manuals