Aranet Aranet2 HOME User manual

Aranet2 monitor is an innovative wireless device for eortless monitoring of indoor air temperature and
relative humidity. The device can be used at home, in school, oce, or any other indoor environment.
Download the Aranet Home app and connect via Bluetooth. The app allows you to configure the Aranet2
device and access the data monitored by the device. Read a detailed description of all the possibilities
that the app oers in the chapter How to pair Aranet2 to my smart device using the Aranet Home app on
page 3.
Additionally, up to 100 Aranet2 PRO devices can be connected to the Aranet PRO base station. Refer to
the chapter Using Aranet2 device with the Aranet PRO base station on page 4.
There are two Aranet2 models – Aranet2 HOME and Aranet2 PRO. You can find out more about how they
dier in this informative leaflet.
Measurement and data transmission*intervals are 1,2,5, or 10 minutes. The default measurement
interval is set to 5 minutes.
The amount of the stored historic measurement data depends on the measurement interval of the device:
The data that is older than the possible storage period will be automatically overwritten in the device
memory with the newly measured data.
* For Aranet2 PRO paired to Aranet PRO base station.
About the Aranet2 monitor
1
Temperature of the air in Celsius or Fahrenheit.
To change the temperature units, refer to the
chapter Switch positions explained on page 2.
Unique device ID
Indicator of PRO device version.
The Aranet2 sensor screen explained
1
2
3
4
5
3
4
5
Battery level.
2
Relative humidity (%)
1
Measurement interval, minutes Historic data availability, days
1
2
8
16
5
10
40
80

2
Temperature below zero
can damage the sensor.
The recommended
operating temperature of
the sensor is 0 °C to 50 °C
(32 °F to 122 °F).
Six-digit pin code
displayed for wirelessly
connecting the device
with your smartphone to
the Aranet Home app via
Bluetooth.
Aranet2 screen indications
Do not remove
batteries
during a firmware
upgrade.
The batteries are
empty. Replace
them.
The Aranet2 monitor has four small configuration
switches that allow the user to adjust the settings.
To access the configuration switches, open the
cover of the battery compartment on the back of
the device. With the batteries remaining inside,
adjust the switch position (up or down) using the pin
tool supplied with the Aranet2 device.
You can adjust the switches with the batteries
removed as well, but note that, if you remove the
batteries, it will erase the measurement history
from Aranet2 memory. To avoid this, update the
data in the Aranet Home app before removing the
batteries. The new settings will start working once
the batteries are back in.
Switch positions explained
Switch tool (PIN) can be
found in Aranet2 Quick Start
Guide English version.
Bluetooth – turn on or o the
Bluetooth (connection to
Aranet Home app).
Temperature measurement
units – change to Celsius or
Farenheit degrees.
Enable/disable the connection to
Aranet PRO base station
(available only for Aranet2 PRO
device). Refer to the chapter Using
Aranet2 device with the Aranet
PRO base station on page 4.
°C
°F O
(OFF)
O
(OFF)
Not used

3
Download the Aranet Home app and connect
your smartphone to the Aranet2 device via
Bluetooth* to:
How to pair Aranet2 to my smart device
using the Aranet Home app
* Access to the device’s location should be allowed because
of the general requirement for Bluetooth apps to work
correctly on Android OS.
Launch the Aranet Home app.
Add Aranet2 to the app by pressing
“+ PAIR NEW DEVICE” button.
Select the necessary Aranet2 from the
devices list and press “+ PAIR”.
Accept the pairing procedure.
Enter the 6-digit pin code that is shown on
the display of your Aranet2 device.
To connect your Aranet2 to your smart device,
make sure Bluetooth connectivity is enabled on
your mobile device and your Aranet2 monitor,
and follow these steps:
We advise you to check the app for Aranet2 newest firmware
versions regularly and use the oered upgrades.
1
2
3
4
5
Aranet Home App is currently available on iOS
and Android devices. Requires Android 8.1 or
newer or iOS 13.0 or newer.
Access real-time measurement data.
Store up to 90-day measurement history
and export it as a CSV file.
Change sensor measurement interval and
thresholds.
Access all nearby Aranet devices.
Activate firmware updates for the
Aranet2 devices.
Background data synchronization.
Lounge

– Aranet2 protection class: IP 20.
– Aranet2 is not impact-resistant.
– Do not leave Aranet2 in direct sunlight.
In case of a return or a warranty claim, please fill out the RMA form on the Aranet web page
rma.aranet.com. For Terms and Conditions refer to aranet.com/terms-and-conditions.
If you have purchased your device on Amazon, please follow Amazon’s Returns Policy.
The Aranet PRO base station collects and stores data from all types of Aranet sensors, including Aranet2
PRO. Up to 100 sensors can be connected to one base station. The Aranet PRO base station has an
internal memory to store the measurement data for up to 10 years.
Find out more about the Aranet PRO base station at aranet.com and follow the Aranet PRO
User Manual on how to pair Aranet sensors to the Aranet PRO base station.
If you can’t find the answer that you are looking for in this manual, please take a look at the Aranet Forum
at forum.aranet.com/all-about-aranet2. Otherwise, send us a message to support@aranet.com.
More information about Aranet2 HOME
and Aranet2 PRO can be found at
aranet.com/products/aranet2
Discuss. Get support. Exchange your experience.
4
Using Aranet2 PRO monitor with the
Aranet PRO base station
Returns and warranty
Frequently asked questions (FAQ)
Additional links
For more information about Aranet products, please visit aranet.com,
contact your Aranet representative or write to info@aranet.com.
Product specifications are subject to change without prior notice.
© 2023 SAF Tehnika, JSC. All rights reserved.

This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used following the instructions, may interfere with radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment interferes with radio or
television reception, which can be determined by turning the equipment o and on, the user is encouraged to
avoid the interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
“This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.”
The information presented in this guide is the property of SAF Tehnika, JSC. No part of this document
may be reproduced or transmitted without proper permission from SAF Tehnika, JSC.
The specifications or information in this document are subject to change without notice due
to continuing introduction of design improvements. If there is any conflict between this document and
compliance statements, the latter will supersede this document.
SAF Tehnika, JSC has no liability for typing errors in this document or damages of any kind that result
from the use of this document.
To get up-to-date information about accessories and their availability, please contact a sales
representative.
Industry Canada Regulatory Statement
This device complies with Industry Canada’s license-exempt RSSs. Operation is subject to the following
two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired
operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d'en compromettre le fonctionnement.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
FCC compliance statement
5
This manual suits for next models
1
Table of contents
Other Aranet Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Senso
Senso AK53 user manual

ITALON
ITALON GS.01.00.00.000 IM Installation, Adjustment and Connection Manual

International Light Technologies
International Light Technologies ILT1000 Application notes

Pentax
Pentax 425-VDN quick start guide

VDO
VDO VIEWLINE AMMETER Product information

Sotera
Sotera 825P Installation and operation manual