ARC MWMR-2300 User manual

1
Issue Date: 22/1/2020
WIRELESS MINI WALL MODULE
MWMR-2300
CONTENTS
1. Overview and features Page 2.
2. Diagrams Page 3.
3. Installation –Wiring Page 4.
4. Pairing / Un-pairing device Page 7.
5. Delay Off timer setup Page 9.
6. Operation Page 11.
7. Specifications Page 12.

2
Issue Date: 22/1/2020
1.Overview and features
Powerful 2300W mini wall switch receiver module with adaptive mains zero
crossing switching.
Main features of Mini Wall Module;
•Compatible to L and M series’.
•Small compact size for installation into wall box or inside light fittings.
•Delay off timer (1M / 10M / 1H / 4H) select by trimmer resistor.
•32 memories, first in first out storage maintain.
•Scene status memory, create your desired atmosphere.
•2-way switch function.
Not compatible to:
ARC Code switch system product range
OVERVIEW AND FEATURES

3
Issue Date: 22/1/2020
2.Diagrams
Notes for the diagrams:
N - Terminal for neutral wire
L- Output terminal for load wire
S - Terminal for power supply to the switch
L - Terminal for live wire
⚫Strip the solid wires (rigid conductor only) at least 7mm then connect the
wires as per diagrams below, ensure terminals are properly tightened and
no bare wire is visible.
⚫Suitable wire size for terminal is 1.6mm2 to 2mm2
DIAGRAMS

4
Issue Date: 22/1/2020
3.Installation - Wiring
Cut off main power before installing and wiring.
Current existing house wiring should be as below.
INSTALLATION - WIRING

5
Issue Date: 22/1/2020
Add mini module with one way operation
1. Connect permanent Live wire into module terminal ‘L’.
2. Connect Neutral wire into module terminal ‘N’.
3. Connect wire from module terminal ‘ L& N’ to Load.
4. Connect switch Live wire from module terminal ‘S’ into switch ‘L1’ terminal.
5. Connect permanent Live wire into switch ‘Com’ terminal.
6. Connect back mains power supply.
INSTALLATION - WIRING

6
Issue Date: 22/1/2020
Add mini module with two way operation
Two Way Operation
1. Switch 1 and 2 must be connected together with wires into ‘L1 & L2’ terminal.
2. Connect permanent Live wire into module terminal ‘L’.
3. Connect Neutral wire into module terminal ‘N’.
4. Connect wire from module terminal ‘ L& N’ to Load.
5. Connect permanent Live wire into switch 1 ‘Com’ terminal.
6. Connect switch Live wire from module terminal ‘S’ into switch 2 ‘Com’
terminal.
7. Connect wire from module terminal ‘L& N’ to Load
8. Connect back mains power supply.
INSTALLATION - WIRING

7
Issue Date: 22/1/2020
4.Pairing / Un-pairing Device
PAIRING
Pairing using LEARNING MODE:
1. Press ‘Learn’ button once (LED on module will flash), this will enter learning
mode.
2. With a remote control press the ‘ON’ button; LED on module will flash to
confirm that the remote control is now paired.
NOTE: If no signal is received from a remote control within 12 seconds then the
module will automatically exit learning mode without pairing the device.
To exit learning mode manually, simply press the ‘Learn’ button again.
PAIRING / UN-PARING DEVICE

8
Issue Date: 22/1/2020
UN-PAIRING
Removing single Device:
1. Press ‘Learn’ button once (LED on module will flash), this will enter learning
mode.
2. With a remote control press the ‘OFF’ button intended to be un-paired; LED
on module will flash to confirm that the remote control is un-paired.
CLEARING ALL MEMORY
Removing all memory stored in the module.
1. On the module hold down the ‘Learn’ button for 6 seconds, LED on module
will flash.
2. Release button then press again, this will remove all memory stored in the
module.
PAIRING / UN-PARING DEVICE

9
Issue Date: 22/1/2020
5.Delay Off Timer Setup
You may choose the mini module to operate normally as an ON/OFF receiver or
have the extra benefit to set up delay off timer.
Factory pre-setting will be at ‘0’ hour position as normal ON/OFF receiver.
Set up delay off timer:
⚫There are 4 timer selections, 1 min –10 mins –1 hour –4 hours
⚫Adjust rotary switch clockwise to the hours that you wish to setup.
⚫LED on module will blink once to confirm the mini wall module is properly
setup in each time slot.
⚫Timer will only remember the first activate timer.
⚫If during timer count down you adjust the time slot, mini wall module will
ignore the new timer until the current timer ends or you manually turn OFF.
So next time you switch on the module the new timer will be activated.
DELAY OFF TIMER SETUP

10
Issue Date: 22/1/2020
Example:
1. Adjust rotary switch clockwise to position 1m. LED on module will blink
once to confirm.
2. Turn ON mini module and timer will start to count down
3. Once timer reaches to 1 minute it will automatically turn OFF.
4. If during the count down the mini module is turned OFF then this will
automatically deactivate the timer count down.
DELAY OFF TIMER SETUP

11
Issue Date: 22/1/2020
6.Operation
Mini module is compatible to “Self Learning” system and M series remote
control. Please refer to the relevant user guide for detailed operation.
Operation via Rocker Switch:
Turn the load ON:
Toggle switch once to turn ON load.
Turn the load OFF:
Toggle switch once again to turn OFF load.
Operation example using in conjunction with a remote control and rocker switch.
If load is switched ON from the rocker switch then switch OFF via the remote
control.
The next time turning ON the load can either be:
(i) on the remote press the ON button
OR
(ii) on rocker switch toggle switch once.
Rocker Switch Two way operation:
Turn the load ON:
Toggle switch once to turn ON load.
Turn the load OFF:
Toggle switch once again to turn OFF load.
Operation example:
Switch 1 is located downstairs & Switch 2 is located upstairs.
While going up the stairs, toggle “Switch 1” once to turn ON the load, once you
reach upstairs toggle “Switch 2” once to turn OFF the load.
OPERATION

12
Issue Date: 22/1/2020
7.Specifications
Input Rating: 230V~50Hz
Output Rating: 2300W (Resistive Load)
Radio Frequency: 433.92MHz
Power consumption: 1W
Environment Temperature: 0-40 ºC
Range: up to 50 m indoors (Depends on building
materials)
In accordance with: Low Voltage Directive 2014/35/EU
RED Directive 2014/53/EU
CE Certification: The CE marked affixed to this product confirms
Its complaisance with the European Directives
Which apply to the product and in particular its
compliance with the harmonizes standards and
specifications.
Dimension (L x W x H) 45 x 40 x 15.2mm
Weight: 20 g
NOTE
⚫Please leave minimum of 1.5 meters in-between 2 or more modules.
⚫When inserting module into back box make sure excess wires do not cover
module’s back side. This may reduce the performance of radio
transmission.
⚫During standby mode, LED on module will not illuminate.
SPECIFICATION