Arec CI-218 User manual

CI-218 / CI-303 / CI430
Network Camera
User Manual English
AREC Inc.© All Rights Reserved 2017. l www.arec.com
All information contained in this document is Proprietary

CI-218 / CI-303 / CI-430 Network Camera
2
3
Table of Contents
1. Overview
1.1 Features
1.2 Package Contents
1.3 Dimensions
1.4 Connectors
2. Camera Cabling
2.1 Power Connection
2.2 Ethernet Cable Connection
2.3 Alarm I/O Connection
3. System Requirements
4. Access Camera
5. Setup Video Resolution
6. Conguration Files Export / Import
7. Delete the Existing DC Viewer
7.1 Delete the Existing DC Viewer
7.2 Setup Internet Security
Appendix: Video Resolution
03
03
04
04
05
08
08
08
08
09
10
14
15
16
16
16
18

CI-218 / CI-303 / CI-430 Network Camera
2
3
The CI series Network Camera supports both H.264 and MJPEG standard.
The Network Camera is capable of delivering Multi-streaming Full HD 1080P
real-time video, and offers supreme image quality while keeping efcient and
valuable network bandwidth for storage management.
The camera also supports WDR function, which can provide better image
quality under extreme light contrast scenario or changing lighting environment.
Furthermore, the camera offers strengthened support for pro A/V application
that demands consistent precision zoom control while high resolution and
superior video quality are requisite.
• Progressive CMOS Sensor Support up to 2M / 3M / 4M Resolution
• 3x / 18x/ 30x Optical Zoom with Auto Focus
• Quad Streams support
• H.264 Baseline / Main Prole / High Prole and MJPEG Codec Support
• Multi-language Support
• Smart Event Function-Motion Detection / Network Failure Detection /
Tampering Alarm / Periodical Event / Manual Trigger / Audio Detection
• 3D Noise Reduction / 2D Noise Reduction
• Day/Night (ICR)
• Auto Iris Lens Support
• Text Overlay and Privacy Masks
• microSD Support
• BNC Analog Output
• RS-485 Support
• ONVIF Support
1. Overview
1.1 Features

CI-218 / CI-303 / CI-430 Network Camera
4
5
Please check the package containing the following items listed below.
The dimensions of the camera are shown below.
Network Camera
Power Terminal Block
(vary depending on the camera model)
Power adapter
Quick Guide
1.2 Package Contents
1.3 Dimensions
75.2
58.99
183.48
195.33
52 49
75.2
58.99
165.00
177.00
52 49
CI-218 & CI-430
CI-303
This guide is for quick installing and connecting the CI-218 Network Camera. For more details,
please refer to the User’s Manual.
No. Connector Definition
1
2
3
4
5
6
7
8
9
* Do NOT connect external power supply to the alarm I/O connector of the camera.
Please follow the instructions below for cable connections.
Power Connection
Please use a DC 12V / AC 24V power adaptor and plug it to the power connector of camera
and the power outlet. Alternatively, users can use an Ethernet cable and connect it to the
RJ-45 connector of the camera and a Power Sourcing Equipment (PSE) switch.
Ethernet Cable Connection
Connect one end of the Ethernet cable to the RJ-45 connector of the camera, and plug the
other end of the cable to the network switch or PC.
A client program will be automatically installed to the PC when connecting to the camera.
Before logging in to the camera, please ensure downloading the ActiveX control is allowed by
either changing the ActiveX controls and plug-ins or setting Internet’s security level to
default. For further details, please refer to the User’s Manual.
NOTE : To purchase power adaptor, please contact the camera manufacturer for further
information.
NOTE : If PoE is used, make sure PSE is in use in the network.
NOTE : In some cases, Ethernet crossover cable might be needed when connecting the
camera directly to the PC.
NOTE : It is not recommended to record with the microSD card for 24/7 continuously, as it
may not be able to support long term continuous data read/write. Please contact
the manufacturer of the microSD card for information regarding the reliability and
the life expectancy.
Audio I/O
Power LED
Default Button
RJ-45
Network LEDs
Alarm I/O *
BNC Connector
microSD Card Slot
Power
(DC 12V / AC 24V)
Two-way audio transmission
For power connection indication (green light)
Press the button with a proper tool for at least 20 seconds
to restore the system.
For network and PoE connections
For network connection and activity indication
Alarm Out +
Alarm Out –
Alarm In +
GND
D –
D +
Alarm In –
–
1
2
3
5
6
7
4
For analogue video output
Insert the microSD card into the card slot to store videos
and snapshots. Do not remove the microSD card when the
camera is powered on.
+DC 12V
DC 12V Reserved
DC 12V GND
AC 24V 1
AC 24V GND
AC 24V 2
CI-218 Network Camera Quick Guide
1
4
6
3
2
5
7
8
9
Camera’s Connectors
Camera Cabling
Before Login to the Camera
NOTE : Check the status of the link indicator and the activity indicator LEDs. If the LEDs
are unlit, please check the LAN connection.
Green Link Light indicates good network connection.
Orange Activity Light flashes for network activity indication.
NOTE : The ITE is to be connected only to PoE networks without routing to the outside
plant or equivalent description.
Step 1 : Start the Internet Explorer (IE).
Step 2 : Select <Tools> from the main menu
of the browser. Then click on
<Internet Options>.
Step 3 : Click on the <Security> tab and
select<Internet>, and click on
<Custom level> to change ActiveX
settings.
Step 4 : Set “ActiveX controls and plug-ins”
items to<Prompt> or <Enable>.
ActiveX Controls and Plug-ins Settings
Step 1 : Start the Internet Explorer (IE).
Step 2 : Select <Tools> from the main menu
of the browser.Then click on
<Internet Options>.
Step 3 : Click on the <Security> tab and
select<Internet>.
Step 4 : Down the page, click <Default Level>
and click on <OK> to confirm the
setting. Close the browser window,
and open a new one later for
accessing the camera.
Internet Security Level

CI-218 / CI-303 / CI-430 Network Camera
4
5
The diagram below shows the camera’s reset button and various connectors.
Denition for each connector will be given as follows.
1.4 Connectors
No. Connector Denition
1 Audio I/O Two-way audio transmission
2 Power LED For power connection indication (green light)
3 Default Button Press the button with a proper tool for at least 20
seconds to restore the system.
4 RJ-45 For network and PoE connections
5 Network LEDs For network connection and activity indication
6 Alarm I/O *
1 Alarm Out + 5 GND
2 Alarm Out – 6 D –
3 Alarm In + 7 D +
4 Alarm In –
7 BNC Connector For analogue video output
8 microSD Card Slot
Insert the microSD card into the card slot to store
videos and snapshots. Do not remove the microSD
card when the camera is powered on.
9Power
(DC 12V / AC 24V)
+ DC 12V AC 24V 1
DC 12V Reserved AC 24V GND
– DC 12V GND AC 24V 2
1
4
6
3
2
5
7
8
9
*Do NOT connect external power supply to the alarm I/O connector of the camera.
CI-218

CI-218 / CI-303 / CI-430 Network Camera
6
7
No. Connector Denition
1 BNC For analogue video output
2 Network LEDs For network connection and activity indication
3 Audio I/O Two-way audio transmission
4 microSD Card Slot
Insert the microSD card into the card slot to store
videos and snapshots. Do not remove the microSD
card when the camera is powered on.
5 PoE Network (RJ-45) For network and PoE connections
6 Default Button Press the button with a proper tool for at least 20
seconds to restore the system.
7 Power LED For power connection indication (green light)
8 Power (DC 12V)
For power connection. If users are to use with AC
24V power adaptor, please rst connect the supplied
power switch to the power connector.
9 Alarm I/O *
1 Alarm In 2 + 5 Alarm Out +
2 Alarm In – 6 D +
3 Alarm In 1 + 7 D −
4 Alarm Out –
*Do NOT connect external power supply to the alarm I/O connector of the camera.
6
8
5
73
9
1
4
2
CI-303

CI-218 / CI-303 / CI-430 Network Camera
6
7
No. Connector Denition
1 Audio I/O Two-way audio transmission
2 Power LED For power connection indication (green light)
3 Default Button Press the button with a proper tool for at least 20
seconds to restore the system.
4 RJ-45 For network and PoE connections
5 Network LEDs For network connection and activity indication
6 Alarm I/O *
1 Alarm Out + 5 GND
2 Alarm Out – 6 D –
3 Alarm In + 7 D +
4 Alarm In –
7 BNC Connector For analogue video output
8 microSD Card Slot
Insert the microSD card into the card slot to store
videos and snapshots. Do not remove the microSD
card when the camera is powered on.
9Power
(DC 12V / AC 24V)
+ DC 12V + AC 24V 1
DC 12V GND AC 24V GND
– DC 12V – AC 24V 2
1
4
6
3
2
5
7
8
9
* Do NOT connect external power supply to the alarm I/O connector of the camera.
NOTE : It is not recommended to record with the microSD card for 24/7 continuously, as it may not be
able to support long term continuous data read/write. Please contact the manufacturer of the
microSD card for information regarding the reliability and the life expectancy.
CI-430

CI-218 / CI-303 / CI-430 Network Camera
8
9
Please follow the instructions below to complete the camera connection.
2. Camera Cabling
Please refer to section Connectors. Alternatively, users can power up the
camera by PoE if a Power Sourcing Equipment (PSE) switch is available. Refer
to the section below for Ethernet cable connection.
To have best transmission quality, cable length shall not exceed 100 meters.
Connect one end of the Ethernet cable to the RJ-45 connector of the camera,
and the other end of the cable to the network switch or PC. The RJ-45 port
networks without routing to the outside plant.
The camera equips one alarm input and one relay output for alarm application.
Refer to alarm pin denition below to connect alarm devices to the camera if
needed.
CI-218 & CI-430 CI-303
Check the status of the link indicator and the activity indicator LEDs. If the
LEDs are unlit, please check the LAN connection.
NOTE: If PoE is used, make sure PSE is in use in the network.
NOTE: In some cases Ethernet crossover cable might be needed when
connecting the camera directly to the PC.
Green Link Light indicates good network connection. Orange
Activity Light flashes for network activity indication.
1. Alarm Out +
2. Alarm Out -
3. Alarm In +
4. Alarm In -
1. Alarm In 2 +
2. Alarm In −
3. Alarm In 1 +
4. Alarm Out -
5. Alarm Out +
2.1 Power Connection
2.2 Ethernet Cable Connection
2.3 Alarm I/O Connection

CI-218 / CI-303 / CI-430 Network Camera
8
9
To perform the Network Camera via web browser, please ensure the PC is in
good network connection, and meet system requirements as described below.
3. System Requirements
NOTE: The ITE is to be connected only to PoE networks without routing to the
outside plant or equivalent description.
Items System Requirement
Personal Computer
Minimum :
1. Intel® CoreTM i5-2430M @ 2.4 GHz
2. 4 GB RAM
Recommended :
1. Intel® CoreTM i7-870 @ 2.93 GHz
2. 8 GB RAM
Operating System Windows VISTA / Windows XP / Windows 7
Web Browser
Microsoft Internet Explorer 7.0 or later (recommended)
Firefox (32-bit)
Safari
Network Card 10Base-T (10 Mbps), 100Base-TX (100 Mbps) or
1000Base-T operation
Viewer ActiveX control plug-in for Microsoft IE
Apple QuickTime 7.7.7 or before for Firefox

CI-218 / CI-303 / CI-430 Network Camera
10
11
The default network setting of the camera is DHCP, which means IP is assigned
by a router or any DHCP server. To log in to the administration web, please
connect the camera and your PC / Notebook or a DHCP server. Follow below
steps to access the camera for the rst time.
4. Access Camera
• Run the “Device Search Tool” utility, and click button.
• The tool should nd the network camera and show detailed information.
Double click on the founded camera.
• An access window will pop-up and ask for user name and password.
If no IP is assigned due to a DHCP server failure, or simply because the camera
is not connected to a DHCP server, the Network Camera provides an alternate
IP address: 192.168.11.202
Therefore, to access the camera for the rst time, please set the IP address of
the PC as: 192.168.11.XXX; for example:
In the case where the DHCP server is unavailable
This manual suits for next models
2
Table of contents
Other Arec Security Camera manuals