manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Arena Luci Design
  6. •
  7. Lighting Equipment
  8. •
  9. Arena Luci Design THOR LED 60x60 Elite Series User manual

Arena Luci Design THOR LED 60x60 Elite Series User manual

THORLED
60x60Elite
User'smanual
Ultraslim60x60LEDpanel
This unit should only be used for purpose for
which it has been intended and should be
installed using the instructions which are
provided. Arena Luci cannot be held liable for
damagestoperson,animalsorobjectsasaresult
ofimproper,unreasonableandwrongusage.
This instruction manual contains important
information about the installation and use of the
luminaire. Please read and follow these
instructionscarefully.
Thesecurityofthisdeviceisguaranteedonlywith
the proper use of the following instructions,
thereforetheymustbekeptcarefully.
Never install the device in locations easily
accessiblebypeoplewhoignoretheexistenceof
thisuser'smanualandsafetyinstructions.
For the wiring please refer to enclosed wiring
diagrams. If in the diagrams indicated there
shouldnotbethatofyourapplication,contactthe
technicaloffice.
Disconnecttheunitfromanypowersupplybefore
attempting any operation in contact or inside the
unit,andwhennotinuse.
Itisessentialthateachdeviceiscorrectlyearthed
and that electrical installation conforms to all
relevant standards. Never supply the unit without
theearthlink.
Prior to connect the unit to the mains supply,
check the output voltage fits the technical
requirementsonthelabel.
Never let the power cord come into contact with
othercables.
Nevertouch theelectrical contacts, either directly
with your fingers, or indirectly by means of sharp
ormetalobjects.
Makesurethatcablescannotcausetriphazard.
Donotattempttodismantleandmodifytheunit.
Due to the high technological level of this unit,
anyservicemaintenance should beperformedby
specialised operators. Please contact yourArena
Lucidealerforanyoperation.
Alwaysensurethatthestructuretowhichyouare
attachingtheunitissecureandisabletosupport
theweightofeachunit.
Do not allow contact with water or any other
fluids,ormetallicobjects(IP54/IP40).
Avoidinstallingtheunitclosetoheatsources.
Neverleanthepowercordonhotunitsurfaces.
Allowed to be mounted directly on inflammable
surfaces.
Installtheunitwhereitcanbeeasilyaerated.
Do not install the luminaire on deformed or
damagedceilings.
Thelightingapparatusmustbeusedonlywithits
protectiveplasticshield.
Contact your Arena Luci dealer if the protective
shieldisvisiblydamagedtothe point at which its
effectiveness is diminished, for example by
becomingcrackedordeeplyscratched.
LEDmoduleisnotreplaceable.
Do not use any solvent based cleaning agents.
Useonlyasoft,dryantistaticcloth.
The installation of LED modules (including power
supplies) should be done according to current
technical rules and regulations. The installation
shouldbeperformedonlybyaqualifiedoperator.
Avoid contact with either corrosive agents or
humidity and moisture on delicate elements:
damages from corrosion are not refunded as
componentdefects.
WARNINGS
Please note that as part of Arena Luci's ongoing commitment to continuous product development,
specifications are subject to change in the course of product improvement without notice.Arena Luci is not
responsiblefordamagesresultingfromimproperordifferentusethanexpected.
PNL2140iWW
PNL2140iNW
2/4
PNL2140i
BEFORESTARTING
Remove the product from the shipping carton,
checking that all the components supplied are
presentin the box.Refer tothe following packing
list to check which components must be present
in the packaging. If any component is missing or
damaged, contact your Arena Luci dealer
immediately.
n°1LEDpanelThor60x60Elite
n°1Electronicdriver
Before starting the installation of your product
make sure that there are no evident damages
caused by transportation. In the event that the
luminaireisdamaged,donotplugitinanddonot
attempt to use it until you contacted your Arena
Lucidealerforassistance.
INSTALLATIONANDPOWERSUPPLY
Thepanelcanbeinstalledinafalseceiling,ona
concrete ceiling or suspended. Depending on the
typeofinstallationitisnecessarytofindasuitable
housing for the power supply or it is possible to
placethepowersupplyinthemiddleoftheupper
faceofthepanel.
Alwaysmakesurethatthestructureyouarefixing
the panel is safe and able to bear the weight of
3.1kgofeachappliance,possibly including power
supply.
Remove the mains voltage from the system
before performing any of the installations listed
below.
Drag the derivations from the 230V power line to
the position where the electronic driver will be
installed. Keep in mind that the output of the
powersupplythatisconnectedtothepanelhasa
cable with a length of about 15cm, so there is a
discrete freedom in choosing the position of the
powersupply.
Connectthepowersupplytothemains,usingthe
voltage and frequency indicated on the label and
observing the indicated polarity LNE (colors
brown=L,blue=N,yellow/green=E).Makesure
that no conductors have uncovered copper
pieces.
Itisadvisablethatthepowersupplyisconnected
to the mains via its own switch, so that it can be
switchedonandoffindividually.
Theterminalblockcanacceptconductorsofcross
section between 0.5 and 1.5 mm2; for fixing
remove approximately 56 mm of insulation from
thewires.
It is essential that the electrical installation
complieswithallcurrentgoodtechnicalandsafety
standards.
Falseceilinginstallation
Thor panel has been specially designed to be
housed on a normal frame for squared ceilings.
After having housed the power supply inside the
false ceiling, take the cable with the plug
connectorofthepowersupplyunitoutofthefalse
ceiling and connect it firmly to the corresponding
socket on the panel power cable (Fig. 01).
Positionthepanelonthesupportframe.
Ifthefalseceilingisoftheplasterboardtype,itis
necessary to use the accessory for fixing to a
falseceiling(APL1200).
Make a square hole of the appropriate size for
housing the accessory, as indicated in the
instructions attached to the product, and attach it
totheplasterboard.Laythedriverinsidethefalse
3/4
USER'SMANUAL
ceiling and pull the cable with the plug connector
outfromtheholeinthefalseceilingandconnectit
firmly to the corresponding socket on the panel
power cable (Fig. 01). Insert the panel inside the
casingandfixit.
Ceilinginstallation
Anaccessory (codeAPL1100) isavailable forthe
installation of the panel on a concrete ceiling, in
cases where there is no false ceiling. This is a
framethatmustbefixeddirectlytotheceilingand
inwhichthepanelissubsequentlyinserted.
Beforefixingtheframe,makesurethatthepower
supplylinecanexitinsidetheframeitself.
Drill four holes on the ceiling, arranged at the
corners of a rectangle to fix the frame, get the
interaxis between the holes measuring the frame
and mark them with a pencil on the ceiling. Pass
the power cable through the back of the frame
and then screw the back to the ceiling using
expansion plugs of the type suitable for the type
ofceilingandtheloadtosupporttheweightofthe
frameandpanel.
Once the back of the frame is firmly fixed to the
ceiling, connect the plug connector of the power
supply unit to the corresponding socket on the
panelpowercable(Fig.01).
FinalizetheinstallationbyinsertingtheLEDpanel
on the two guides of the frame pushing it all the
way down, put the power supply in the middle of
the upper face of the panel and finally close the
framebyscrewingtheclosingcover.
Suspendedinstallation
If you wish to install the panel in suspension, an
accessory is available that contains everything
necessary for the purpose (APNL1236S). Follow
theinstructionsattachedtotheproducttoidentify
thefixingpointsonboththepanelandtheceiling
andhowtoadjustthesuspensionheight.
Thecableforconnectiontothemainssupplymust
come out of the ceiling. Firmly connect the plug
connector of the power supply unit to the
corresponding socket on the panel power cable
(Fig.01).
Fig.01ConnectingtheLEDpanel
4/4
PNL2140i
ArenaLucisrlviaSvizzera12/1446042CastelGoffredo(MN),Italy
Tel.+390376782411Fax+390376780973
www.arenaluci.com[email protected]
WARRANTYCONDITIONS
The unit is guaranteed for 24 months from the
date of purchase against defects in workmanship
ormaterialsthatcomposeit.
This warranty does faults due to incorrect or
improperuseofthedevice.
The warranty is immediately void if the unit has
been tampered with or opened by unauthorized
personnel.
The warranty provides, at the discretion ofArena
Luci,repairorreplacementoffaultyequipment.
The serial number and model of the device are
required to obtain information or assistance from
the dealer. We invite you to transcribe them in
time: for any request of information or services,
thiswillresultinaquickandeffectiveoperation.
CERULES
The device meets the essential requirements of
the Directives LVD 2014/35/UE, EMC
2014/30/UE, RAEE 2012/19/UE, RoHS
2011/65/UE, Ecodesign 2009/125/CE  reg. (UE)
1194/2012, Energy label 2010/30/UE  reg. (UE)
874/2012  reg. (UE) 518/2014, GPSD
2001/95/CE.
Warnings
DisposalofOldElectrical & Electronic Equipment
(applicable in the European Union and other
European countries with separate collection
systems).
The product shall not be treated as
householdwastebutmustbehandedoverto
the applicable collection point for the
recycling of electrical and electronic
equipment. By ensuring this product is correctly
disposed, you will help prevent potential negative
consequences for the environment and human
health, which could otherwise be caused by
inappropriate waste handling. The recycling of
materialswillhelptoconservenaturalresources.For
more detailed information about recycling of this
product, please contact your city office, your
householdwastedisposalserviceoryoursupplier.
Powersupply
Powerconsumption
Sorce
ColorTemperature
Luminousflux
Beamaperture
Socket
Drillinghole
Material
Color
Weight
Dimensions
Insulationclass
Protection
Ambienttemperature
Suitabletobefittedonnormallyinflammablesurfaces
Appliedstandards
220240VAC,50/60Hz
40W
smdLED
3000K(WW)4000K(NW)
3878lm(WW)3955lm(NW)
120°
Terminalblock
600x600mm(APL1200)
Aluminium+PC
Whiteframe
Body:3.1kgDriver:105g
Body:595x595x11mmDriver:147x44x30mm
I
IP54(front)IP40(rear)
25°C...+45°C
TECHNICALSPECIFICATIONS
PNL2140iENR0|10/2018

This manual suits for next models

2

Popular Lighting Equipment manuals by other brands

NuTone Haven HVLFABR Assembly & wiring instructions

NuTone

NuTone Haven HVLFABR Assembly & wiring instructions

Foxfury Lighting Solutions NOMAD NOW product manual

Foxfury Lighting Solutions

Foxfury Lighting Solutions NOMAD NOW product manual

Ikan iLED6 quick start guide

Ikan

Ikan iLED6 quick start guide

Strand R21 installation guide

Strand

Strand R21 installation guide

GE LED 50 C9 LIGHTS quick start guide

GE

GE LED 50 C9 LIGHTS quick start guide

Griven RB250 instruction manual

Griven

Griven RB250 instruction manual

GE Tetra PowerStrip DS installation guide

GE

GE Tetra PowerStrip DS installation guide

Zumtobel SensControl operating manual

Zumtobel

Zumtobel SensControl operating manual

John Lewis BALDWIN user guide

John Lewis

John Lewis BALDWIN user guide

Secom COMBOX DC CARRIL user guide

Secom

Secom COMBOX DC CARRIL user guide

Allmand MAXI-LITE V-SERIES Operator's manual

Allmand

Allmand MAXI-LITE V-SERIES Operator's manual

Rush MH 1 Profile Plus user manual

Rush

Rush MH 1 Profile Plus user manual

Blizzard COLORISE RGBALC user manual

Blizzard

Blizzard COLORISE RGBALC user manual

Clas Ohlson LUM-ROC145X158W1-01D instructions

Clas Ohlson

Clas Ohlson LUM-ROC145X158W1-01D instructions

Electrovision Eagle G009MH instruction manual

Electrovision

Electrovision Eagle G009MH instruction manual

Philips 69087/**/16 user manual

Philips

Philips 69087/**/16 user manual

Williams 96 LED Series installation instructions

Williams

Williams 96 LED Series installation instructions

EasyPro Stratus SRC Series instructions

EasyPro

EasyPro Stratus SRC Series instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.