Maintenance:
All lighting equipment is delicate and easily damaged
through misuse or inappropriate installation
(mechanical or electrical). Repairs and replacements
may cause delays and will be chargeable. Contact SL
for support if required.
All Stoane Lighting products are covered by a five year
Warranty and a 25 year Duty of Care. Products are
designed to be upgraded, adapted and refreshed
using our comprehensive ReNew service. For more
information on our ReNew service and for full
Warranty terms and conditions visit stoanelighting.com
or contact us at the address shown.
When supplying digital equipment with the potential to
be connected to networks, physically or wirelessly (i.e.
Bluetooth, WiFi, DMX radio etc.), SL does not take
responsibility for the digital security of the equipment
or associated networks. It is the customer’s
responsibility to select a protocol suitably robust for
their requirements and to ensure responsible
utilisation of passwords.
The light source contained in this luminaire shall only
be replaced by the manufacturer or his service agent
or a similar qualified person.
If the external flexible cable or cord of this luminaire is
damaged, it shall be exclusively replaced by the
manufacturer or his service agent or a similar qualified
person in order to avoid a hazard.
Full disassembly notes are available on our website,
and are accessed by entering your product serial
number into the search function of our website. Serial
numbers are typically located in an area that is not
visible when the fitting is installed.
Cleaning:
Fully isolate the fitting and allow to cool.
Clean the fitting with a slightly damp lint free cloth from
a mild solution of soap and water. The fitting must be
completely dry before reconnecting power.
Incompatible or abrasive chemicals can damage the
fitting, contact SL for advice if required.
Electrical Supply
Installation must be carried out by a qualified electrician in
accordance with BS 7671:2008 Wiring Regulations.
230/240V AC 50/60Hz mains supply to a suitable SELV
LED Driver.
Site conditions: LED equipment is more susceptible to
static damage and over voltage than previous technology.
Before handling or connecting to the mains supply ensure
that all Stoane Lighting (SL) products are protected from
static discharge and that the mains supply is to regulation.
(230V +10 -6%)
This fitting is supplied with a Xicato LED module. Refer to
the fitting label for the module version and wattage. More
information on the module can be found on the attached
technical note or at www.xicato.com/support
Mains cables must be double insulated, strain relieved
and separated from E.L.V output cables.
This unit requires a constant current driver. 1050mA Max.
Observe polarity:
Positive (+) is marked as RED.
Incorrect supply or reverse polarity can cause irreparable
damage.
All connections must be made before switching on mains.
If the supply is energised prior to making the connections
to the fitting then the resulting surge will damage the LED.
The entire dimming control circuit source must be of SELV
insulation class.