Arista Q6EWL User manual

Quick Start Guide
Edge Threat Management
Appliance
CCA-ETM-Q6EWL
Arista Networks
www.arista.com
DOC-06005-01

Headquarters
5453 Great America Parkway,
Santa Clara, CA 95054
USA
+1-408 547-5500
Support
+1-408 547-5502
+1-866 476-0000
Sales
+1-408 547-5501
+1-866 497-0000
© Copyright 2023 Arista Networks, Inc. All rights reserved. The information contained herein is subject to change
without notice. The trademarks, logos and service marks ("Marks") displayed in this documentation are the property
of Arista Networks in the United States and other countries. Use of the Marks are subject to Arista Network Term
of Use Policy, available at http://www.arista.com/en/terms-of-use. Use of marks belonging to other parties is for
informational purposes only.

Contents
Contents
Chapter 1: Overview................................................................................1
1.1 Scope......................................................................................................................................1
1.2 Receiving and Inspecting the Equipment...............................................................................1
1.3 Installation Process.................................................................................................................2
1.4 Safety Information...................................................................................................................3
1.5 Obtaining Technical Assistance............................................................................................. 3
1.6 Specifications..........................................................................................................................4
Chapter 2: Preparation............................................................................5
2.1 Site Selection..........................................................................................................................5
2.2 Tools and Parts Required for Installation...............................................................................6
2.3 Electrostatic Discharge Precautions.......................................................................................6
Chapter 3: Mounting the Appliance.......................................................7
3.1 Desktop Installation................................................................................................................ 7
3.2 Rack Mounting the Appliance................................................................................................ 8
3.2.1 Mounting the Power Supply....................................................................................10
3.2.2 Attaching Mounting Brackets to the Chassis..........................................................11
3.2.3 Inserting the Appliance into the Rack.....................................................................12
3.3 Mounting the Appliance on a Wall.......................................................................................12
Chapter 4: Cabling the Appliance....................................................... 13
Chapter 5: Configuring the Appliance................................................ 15
Appendix A: Status Indicators.............................................................17
A.1 Front Indicators.................................................................................................................... 17
Appendix B: Parts List..........................................................................19
Appendix C: Front Panel...................................................................... 21
Appendix D: Rear Panel....................................................................... 23
Appendix E: Regulatory Model Numbers........................................... 25
Appendix F: Taiwan RoHS Information...............................................27
iii

iv

Chapter 1
Overview
This guide is intended for properly trained service personnel and technicians who need to install
selected Arista Appliances.
The following topics are covered in this section:
•Scope
•Receiving and Inspecting the Equipment
•Installation Process
•Safety Information
•Obtaining Technical Assistance
•Specifications
1.1 Scope
This guide is intended for properly trained service personnel and technicians who need to install the
following Arista Appliance:
CCA-ETM-Q6EWL
Important:
Only qualified personnel should install, service, or replace this equipment.
Seul le personnel qualifié doit installer, service, ou remplacer cet équipement.
1.2 Receiving and Inspecting the Equipment
Upon receiving the appliance, inspect the shipping boxes and record any external damage. Retain
packing materials if you suspect that part of the shipment is damaged; the carrier may need to inspect
them.
If the boxes were not damaged in transit, unpack them carefully. Ensure that you do not discard any
accessories that may be packaged in the same box as the main unit.
Inspect the packing list and confirm that you received all listed items. Compare the packing list with
your purchase order. Parts List provides a list of components included with the appliance.
1

1.3 Installation Process
The following tasks are required to install and use the appliance:
1. Select and prepare the installation site (Site Selection).
2. Assemble the installation tools listed (Tools and Parts Required for Installation).
3. Install the appliance (Mounting the Appliance).
4. Connect the appliance to the power source and network appliances (Cabling the Appliance).
5. Configure the appliance (Configuring the Appliance).
Important:
Class 1 Laser Product: This product has provisions to install Class 1 laser transceivers
which provide optical coupling to the communication network. Once a Class 1 laser product
is installed, the equipment is a Class 1 Laser Product. The customer is responsible for
selecting and installing the Class 1 laser transceiver and for insuring that the Class 1
AEL (Allowable Emission Limit) per EN/IEC 60825, CSA E60825-1, and Code of Federal
Regulations 21 CFR 1040 is not exceeded after the laser transceiver have been installed.
Do not install laser products whose class rating is greater than 1. Refer to all safety
instructions that accompanied the transceiver prior to installation. Only Class 1 laser
Appliances, certified for use in the country of installation by the cognizant agency are to be
utilized in this product.
Produit Laser de classe 1: Ce produit a des dispositions pour installer des émetteurs-
récepteurs de laser de classe 1 qui offre de couplage au réseau de communication
optique.Une fois un produit laser de classe 1 est installé, l'équipement est un produit Laser
de classe 1 (Appareil à Laser de Classe 1).Le client est responsable pour sélectionner et
installer l'émetteur/récepteur de laser de classe 1 et pour assurer que la classe 1 AEL (limite
d'émission admissible) par EN/IEC 6-825, CSA E60825-1, et Code des règlements fédéraux
21 CFR 1040 ne soit pas dépassée après avoir installé l'émetteur/récepteur de laser. Ne
pas installer des appareils à laser dont la cote de classe est supérieure à 1.Voir toutes
les consignes de sécurité qui ont accompagné l'émetteur-récepteur avant l'installation.
Seuls appareils laser de classe 1 certifiés pour une utilisation dans le pays d’installation par
l’organisme compétent doivent être utilisées dans ce produit.
Important:
Ultimate disposal of this product should be handled in accordance with all national laws and
regulations.
Aucune pièce réparable par l'utilisateur à l'intérieur. Confiez toute réparation à un technicien
qualifié.
2

Overview
1.4 Safety Information
Refer to the Arista Networks document Safety Information and Translated Safety Warnings available
at: https://www.arista.com/en/support/product-documentation.
1.5 Obtaining Technical Assistance
Any customer, partner, reseller, or distributor holding a valid Arista Service Contract can obtain
technical support in any of the following ways:
•Email: http://[email protected]. This is the easiest way to create a new service request.
•Web: https://www.arista.com/en/support.
A support case may be created through the support portal on our website. You may also download
the most current software and documentation, as well as view FAQs, Knowledge Base articles,
Security Advisories, and Field Notices.
•Phone: +1 866-476-0000 or +1 408-547-5502.
Important:
No user serviceable parts inside. Refer all servicing to qualified service personnel.
Aucune pièce réparable par l'utilisateur à l'intérieur. Confiez toute réparation à un technicien
qualifié.
3

1.6 Specifications
Table 1: Appliance Specifications (Dimensions and Weights)
Appliance Size (W x D x H) Weight
CCA-ETM-Q6EWL 232mm x 174mm x 42mm 1.4 kg
Table 2: Appliance Specifications (Operational and Storage)
Appliance Operating Temperature
and Relative Humidity Storage Temperature and
Relative Humidity Operating Altitude
CCA-ETM-
Q6EWL 0°C to 40°C
10 to 90% RH
-20°C to 70°C
5 to 95% RH
Sea level to 5000 meters.
Table 3: Appliance Specifications (Power Input)
Power Source Ratings
AC INPUT - 40W Power
Adapter 100~240V, 1.2A, 50-60Hz
4

Chapter 2
Preparation
The following topics are covered in this section:
•Site Selection
•Tools and Parts Required for Installation
•Electrostatic Discharge Precautions
2.1 Site Selection
The following criteria should be considered when selecting a site to install the appliance.
•Temperature and Ventilation: For proper ventilation, install the appliance where there is ample
airflow to the front and back of the appliance. The ambient temperature should not go below 0° or
exceed 40°C.
Important: To prevent the appliance from overheating, do not operate it in an area where
the ambient temperature exceeds 40°C (104°F).
Pour empêcher l’interrupteur de surchauffe, ne pas utiliser il dans une zone où la
température ambiante est supérieure à 40°C (104°F).
•Rack Space: Install the appliance in a 19" rack or cabinet. The appliance height is 1 RU. The rack
mounting kit provides mounting brackets for two-post racks.
When mounting the appliance in a partially filled rack, load the rack from bottom to top, with the
heaviest equipment at the bottom. Load the appliance at the bottom if it is the only item in the rack.
•Other Requirements: Select a site where liquids or objects cannot fall onto the equipment and
foreign objects are not drawn into the ventilation holes. Verify these guidelines are met:
• Clearance areas to the front and rear panels allow for unrestricted cabling.
• All front and rear panel indicators can be easily read.
• Power cords can reach from the power outlet to the connector on the rear panel.
Important: All power connections must be removed to de-energize the unit.
Toutes les connexions d’alimentation doivent être enlevées pour hors tension l’appareil.
5

2.2 Tools and Parts Required for Installation
The following tool(s) are required for installation:
• Philips #2 screwdriver
2.3 Electrostatic Discharge Precautions
Observe these guidelines to avoid ESD damage when installing or servicing the appliance
• Assemble or disassemble equipment only in a static-free work area.
• Use a conductive work surface (such as an anti-static mat) to dissipate static charge.
• Wear a conductive wrist strap to dissipate static charge accumulation.
• Minimize handling of assemblies and components.
• Keep replacement parts in their original static-free packaging.
• Remove all plastic, foam, vinyl, paper, and other static-generating materials from the work area.
• Use tools that do not create ESD.
6

Chapter 3
Mounting the Appliance
The following topics are covered in this chapter:
•Desktop Installation
•Rack Mounting the Appliance
•Mounting the Appliance on a Wall
3.1 Desktop Installation
To install the CCA-EMT-Q6EWL on a desktop, complete the following steps.
1. Remove the four screws on the wall mount bracket on the bottom of the appliance.
2. Remove the wall mount bracket from the bottom of the appliance.
3. Attach the rubber feet to the bottom corners of the appliance.
4. Attach the cables according to Cabling the Appliance.
7

3.2 Rack Mounting the Appliance
To mount the appliance onto a two-post rack, mount the power supply unit, assemble the mounting
brackets to the chassis, and then attach the brackets to the rack posts.
The following topics are covered in this section:
•Mounting the Power Supply
•Attaching Mounting Brackets to the Chassis
•Inserting the Appliance into the Rack
8

Mounting the Appliance
Figure 1: CCA-ETM-Q6EWL Mounting Parts Kit
1 Rack mounting bracket 5 Power supply bracket
2 Rack mounting bracket 6 Fastening plate
3 Mounting screws 7 Power supply
4 Mounting screws
9

3.2.1 Mounting the Power Supply
The following describes the process for mounting the power supply unit.
1. Line up the power supply bracket (1) with the holes on the side of the appliance.
2. Insert screws (2, 7) through the power supply bracket into the appliance.
3. Place 40W PSU (3) inside the bracket.
4. Secure PSU with fastening plate (5) and screws (6).
10

Mounting the Appliance
3.2.2 Attaching Mounting Brackets to the Chassis
This procedure attaches mounting brackets to the appliance chassis.
1. Remove the four screws on the wall mount bracket on the bottom of the appliance.
2. Remove the wall mount bracket from the bottom of the appliance.
3. Place the mounting bracket (1) flush against one side and to the front of the chassis so that the
holes in the bracket and the chassis are in line for the attachment screws.
4. Use three screws (2) to attach the bracket to the chassis.
5. Attach the second bracket (4) to the other side of the chassis with three screws (3).
Note: The bracket will extend away from the chassis and provide three larger holes to
attach to the rack as shown above.
11

3.2.3 Inserting the Appliance into the Rack
This procedure attaches the appliance to the rack.
1. Lift the chassis into the rack. Position the brackets against the rack posts at the same level.
2. Select mounting screws that fit your equipment rack.
Note: Screws required to attach the chassis to the posts are not included. Use the
appropriate screws for the rack posts being used.
3. Attach the brackets to the rack posts.
3.3 Mounting the Appliance on a Wall
You can mount the appliance on a wall or place the appliance on a flat surface, such as a desk or a
shelf.
1. Drill two holes apart in the wall in a vertical or horizontal orientation
Note: Make sure you leave enough clearance around the appliance.
2. Insert nylon plugs into the holes, then insert two 32mm x 6.35mm flat undercut screws into the
plugs.
3. Attach the four provided rubber feet to aid ventilation.
4. Align the mounting holes on the appliance with the screws, then place the appliance on the screws.
After the appliance is mounted on the wall and you have connected the cables, do not pull on the
cables.
12

Chapter 4
Cabling the Appliance
For all installations:
1. Plug in the power adapter to a power source and connect it to the DC 12V power input on the rear
panel.
2. Connect an Ethernet cable from your Internet modem or router to WAN Port 1.
3. Connect an Ethernet cable from your local network to LAN Port 1.
4. Connect a WiFi antenna to the WiFi antenna port on the rear panel.
5. Connect an LTE antenna to the LTE antenna port on the rear panel.
6. Connect a WiFi antenna to the WiFi antenna port on the front panel.
7. Connect an LTE antenna to the LTE antenna port on the front panel.
8. Power on the system by pressing the power button located on the rear panel next to the power
input.
9. Allow approximately two minutes for the system to initialize before continuing with the next steps
13

14

Chapter 5
Configuring the Appliance
You can manage your appliance using the Edge Threat Management Dashboard or from the local
network.
From Edge Threat Management Dashboard
1. Navigate your web browser to https://edge.arista.com/cmd.
2. Log in with your Edge Threat Management Dashboard account, or click Create Account to set up
an account.
3. Navigate to the Appliances screen and click Add.
4. Enter the serial number located on the bottom of your appliance.
5. Click Add to confirm the new appliance.
6. Complete the initial setup to begin managing your appliance.
From the local network
1. Connect an Ethernet cable from your management computer or LAN appliance to the LAN port.
2. From your management computer, check the network status of your system and confirm that you
receive an IPv4 address in the subnet of 192.168.1.0/24 (e.g. 192.168.1.100).
3. In a browser, navigate to http://192.168.1.1.
4. Follow the steps in your browser to complete the setup.