Aristel AV256 User manual

Aristel Networks Issued March 2001 page 1
AVAV256256 System Installation Manual
A
Ar
ri
is
st
te
el
l
N
Ne
et
tw
wo
or
rk
ks
s
AV256
INSTALLATION GUIDE
Version number 1.0 issued March 2001
Aristel Networks Pty Ltd
Unit 1, 25 Howleys Rd.
Notting Hill VIC 3168
Telephone: 03 9542 2300
Facsimile: 03 8544 3299

Aristel Networks Issued March 2001 page 2
AVAV
256256
System Installation Manual
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE..................................2
INTRODUCTION..............................................................................................................2
1. SITE REQUIREMENT...................................................................................................2
2. EQUIPMENT REQUIREMENT.......................................................................................2
3. POWER SUPPLY AND KSU INSTALLATION ................................................................4
4. SYSTEM MODULES.....................................................................................................3
5. TYPES OF KEY TELEPHONE ......................................................................................4
6. SPECIFICATION ..........................................................................................................5
7. ELECTRICAL & OTHER SPECIFICATIONS..................................................................6
8. FEATURES LIST..........................................................................................................7
SYSTEM FEATURES LIST ..................................................................................................7
STATION FEATURES LIST..................................................................................................8
9. PCB AND CABINET LAYOUT.......................................................................................9
9.1 SYSTEM THREE-DIMENSIONAL LAYOUT (ONE CABINET)...................................................9
9.2 SYSTEM ONE CABINET INTER-CIRCUIT LAYOUT............................................................. 14
9.2.1 System two cabinets Inter-Circuit Layout.......................................................... 15
9.2.2 System three cabinets Inter-Circuit Layout....................................................... 17
9.2.3 System four cabinets Inter-Circuit Layout......................................................... 17
9.3 SYSTEM WALL MOUNTING INSTALLATION..................................................................... 18
9.4 A4MBUA (MOTHER BOARD UNIT ............................................................................. 18
9.5 A2PSUA /A2PWUA (SWITCHING POWER SUPPLY)..................................................... 15
9.6 A4MPUA (MAIN PROCESSING UNIT .......................................................................... 16
9.7 A4MIUA (INTERFACE PROCESSING UNIT ................................................................... 17
9.8 A2TKUA (TRUNK UNIT, 4 TRUNK PORTS............................................................. 18
9.9 A4STUA (KEY STATION UNIT, 8 KEY STATION PORTS......................................... 19
9.10 A4SLUA/C (SINGLE LINE STATION UNIT .................................................................. 19
9.11 A4HYUA (HYBRID STATION UNIT ............................................................................ 20
9.12 A4VSUA (VOICE SERVICE UNIT ............................................................................. 21
9.13 A2RSCA (RS232 CARD, FOR SMDR SERIAL PORT DESIGN).................................... 21
9.14 A2RPCA (REMOTE PROGRAMMING CARD)............................................................... 22
9.15 A2MFCA (MULTI FUNCTION CARD)......................................................................... 23

Aristel Networks Issued March 2001 page 3
AVAV
256256
System Installation Manual
9.16 WP5007 WIRING.................................................................................................. 23
10. SYSTEM INSTALLATION ......................................................................................... 24
10.1 SYSTEM BACK-UP BATTERY INSTALLATION................................................................ 24
10.2 FAX MACHINE INSTALLATION................................................................................... 25
10.3 KEY TELEPHONE INSTALLATION................................................................................ 26
10.3.1 General key Station Installation ..................................................................... 26
10.3.2 OHCA Key Station Installation....................................................................... 27
10.3.3 Single Line Telephone Installation.................................................................. 28
10.4 DOOR PHONE INSTALLATION.................................................................................... 28
10.5 EXTERNAL MUSIC SOURCE INSTALLATION.................................................................. 29
10.6 EXTERNAL PAGING EQUIPMENT INSTALLATION............................................................ 30
10.7 MULTIFUNCTION CARD INSTALLATION........................................................................ 30
10.8 RS232 INSTALLATION ............................................................................................ 31
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
Introduction
This manual provides detail procedures for installing the AristelAristel AV-256. Read
this entire section before proceeding with the actual installation.
The National Electrical Code (NEC) requires the Local operation telephone
company (teleco) to provide primary protection devices on telephone lines
terminated at customer’s site. Check the entry point to see that a primary
protectiondeviceisinstalled.Ifnosuchdeviceispresentednotify the telecom
before proceeding with installation.
1. Site Requirement
TheKSUshouldbeinstalledinaclean,dry,secure location that prevent access
by unauthorized personnel. This location must have adequate ventilation and
have a temperature range that does not exceed 32 to 113 degree F (0 to 45
degree C) with a 10Cto 95Cnon-condensing, relative humidity.
The installation site should provide ample room to mount the KSU on the wall
along with the necessary connecting blocks and any ancillary equipment. The
installation site should not be located in areas subject to static electricity (e.g.
dry-copiers), or vibration (e.g. heavy machinery).
Thecustomermust provideadedicatedNEMA5-15R outlet with 115VAC/60Hz

Aristel Networks Issued March 2001 page 4
AVAV
256256
System Installation Manual
(230VAC/50Hz) and a 15 Amp circuit. A separate earth ground is required in
addition to the third wire ground on the AC circuit. If a music source or optional
external paging equipment is installed, it must be connected to separate AC
circuitotherthanthesystem’sdedicatedACline.ONLY THE POWER SUPPLY
SHOULD BE CONNECTED TO THE DEDICATED AC OUTLET.
2. Equipment Requirement
Before installing the equipment, carefully inspect packages for evidence of
external damage or possible damage to the contents. Then compare the
equipment received to a list of equipment order to ensure that all components
are on site.
The following materials are required to install the system:
sExterior grade plywood back board for the KSU.
s20-pairs Amphenol cable (WP5007) with male connector at one for
connection to Amphenol female connector on internal station interface
(A2STUA or A2HYUA or A2SLUA or A4STUA or A4HYUA or A4SLUA).
sTwo-pairs or three-pairs (for OHCA station) twisted station cable.
sGrounding wire (14 AWG).
sConnection blocks (66M1-50 type) with bridging clips.
sModular station jacks (625A4, 625F4, or equivalent with screw terminals).
sAppropriate mounting hardware.
3. Power supply and KSU installation
sAttach the plywood backboard in the designation location with appropriate
fasteners.
sA surge protector should be installed at the dedicated AC receptacle.
sConnect 20-pairs male Amphenol cable to the female Amphenol connector
on internal station interface (A4STUA or A4HYUA or A4SLUA/C). Punch
thetwisted1-pairor2-pairsor3-pairs from the end of male Amphenol cable
to the connecting blocks to the terminals.
sConnect the plugs from RJ11 jack on CO Line Interface to the exchange
CO Line for connecting external CO Line.

Aristel Networks Issued March 2001 page 5
AVAV
256256
System Installation Manual
4. System Modules
Model Description Remark
A2CBPA MAIN CABINET, consisting of (Metal Cabinet) +
(A2PSUA) Standard Shipment
A2PSUA SWITCHING POWER SUPPLY UNIT Spare Part
A4MBUA MOTHER BOARD UNIT (8 I/O Interface Slots) Standard Card
A4MPUA MAIN PROCESSING UNIT Standard Card
A4IPUA INTERFACE PROCESSING UNIT Standard Card
A2TKUA TRUNK UNIT, consisting of 4 CO Line Ports and 2 Ports
per Line Expansion Card
A2DTKA ISDN TRUNK UNIT, consisting of 4 ISDN CO Line Ports
(EURO ISDN S0 interface, 2B+D/port) Expansion Card
A2STUA KEY STATION UNIT, consisting of 8 Key Station Ports
and One Port per Station Expansion Card
A2HYUA HYBRID STATION UNIT, consisting of (2 Key Station
Ports) + (6 Single Line Station Ports) and One Port per
Station Expansion Card
A2SLUA/C SINGLE LINE STATION UNIT, consisting of 8 Single
Line Station Ports and One Port per Station Expansion Card
A2VSUA VOICE SERVICE UNIT, consisting of 4 Voice Channels
(60 seconds per channel) Optional Card
A2MFCA MULTI FUNCTION CARD, consisting of (4 Sensors) +
(4 Relays) Optional Card
A2MDCA METERING DETECTION CARD (for both 12KHz and
16KHz Metering Pulse) Optional Card
A2RSCA RS232 CARD (for SMDR, Serial Port Design) Optional Card
A2RPCA REMOTE PROGRAMMING CARD (standard Modem
design) Optional Card
5. TYPES OF KEY TELEPHONE
Model Description Color
15 Buttons Key Telephone
KP10XW STANDARD PHONE (without LCD and Handsfree) White
KP10XHW STANDARD HANDSFREE PHONE (without LCD, but with
Handsfree)
White

Aristel Networks Issued March 2001 page 6
AVAV
256256
System Installation Manual
Handsfree)
KP10XLW SMALL LCD PHONE (with Small LCD, but without Handsfree) White
KP10XLBW BIG LCD PHONE (with Big LCD, but without Handsfree) White
KP10XDW SMALL LCD DELUXE PHONE (with Small LCD and Handsfree) White
KP10XDBW
BIG LCD DELUXE PHONE (with Big LCD and Handsfree) White
KP10XC STANDARD PHONE (without LCD and Handsfree) Charcoal
KP10XHC STANDARD HANDSFREE PHONE (without LCD, but with
Handsfree) Charcoal
KP10XLC SMALL LCD PHONE (with Small LCD, but without Handsfree) Charcoal
KP10XLBC BIG LCD PHONE (with Big LCD, but without Handsfree) Charcoal
KP10XDC SMALL LCD DELUXE PHONE (with Small LCD and Handsfree) Charcoal
KP10XDBC BIG LCD DELUXE PHONE (with Big LCD and Handsfree) Charcoal
25 Buttons Key Telephone
KP10SW STANDARD PHONE (without LCD and Handsfree) White
KP10SHW STANDARD HANDSFREE PHONE (without LCD, but with
Handsfree) White
KP10LW SMALL LCD PHONE (with Small LCD, but without Handsfree) White
KP10LBW BIG LCD PHONE (with Big LCD, but without Handsfree) White
KP10DW SMALL LCD DELUXE PHONE (with Small LCD and Handsfree) White
KP10DBW BIG LCD DELUXE PHONE (with Big LCD and Handsfree) White
KP10SC STANDARD PHONE (without LCD and Handsfree) Charcoal
KP10SHC STANDARD HANDSFREE PHONE (without LCD, but with
Handsfree) Charcoal
KP10LC SMALL LCD PHONE (with Small LCD, but without Handsfree) Charcoal
KP10LBC BIG LCD PHONE (with Big LCD, but without Handsfree) Charcoal
KP10DC SMALL LCD DELUXE PHONE (with Small LCD and Handsfree) Charcoal
KP10DBC BIG LCD DELUXE PHONE (with Big LCD and Handsfree) Charcoal
64 Buttons Console Phone
DSS64W DSS CONSOLE PHONE (with 64 DSS buttons only) White
DSS64CDSS CONSOLE PHONE (with 64 DSS buttons only) Charcoal

Aristel Networks Issued March 2001 page 7
AVAV
256256
System Installation Manual
6. SPECIFICATION
CO Line 0~40 (20 per cabinet)
Key Telephones 0~255
Single Line Telephones 0~255
Auto Attendant 0~40
Door Phones 0~2 (per cabinet)
Relay Switches 0~16
Sensor Interfaces0~16
Fax Monitor 0~10
System Battery Charger Interface 0~1 (per cabinet)
RS232 for SMDR 0~4
Remote Programming 0~1
Speed Dial 0~1200
External Music 0~1
External Paging 0~1
Intercom Paths (Local) 0~48

Aristel Networks Issued March 2001 page 8
AVAV
256256
System Installation Manual
7. AV-256 ELECTRICAL & OTHER SPECIFICATIONS
Input AC Voltage 115 VAC±10% (50/60 Hz)/0.57Amps
230 VAC ±10% (50/60 Hz)/0.28Amps
System 40 W
Key Telephone 2.0 W max.
SLT 0.85 W
Power
Consumptio
nDoor Phone 0.5 W
System Power Back-Up Battery 1 ~ 2 Hour (24 VDC ×6.5AH)
Key Telephone 40 Ωmax.
Door Phone 40 Ωmax.
SLT 400 Ωmax.
External Paging 600 Ωmax.
Loop
Resistance
CO Line 1.5K Ωmax.
Outgoing Dialing Tone / PulseDialing
Signal Intercom Dialing Tone / Pulse / Digital
CO Line 2 wires
Relay Switch 2 wires
Key Telephone 4 / 6 wires
Sensor 2 wires
SLT 2 wires
External Music 2 wires
Door Phone 2 wires
External Paging 2 wires
Fax Machine 2 wires
Wiring
Installation
SMDR 6 wires
Type SPDT
Power
Consumption 7A, 110VAC / 240 VAC
Relay Switch
Function Door Swit
ching, Paging, Music on Hold, …,
etc.
System Dimension (mm, W ×D ×
H) 555×228 ×400
Key Telephone Dimension (mm) 230L ×180W ×75H
Working Temperature 0 0C ~ 45 0C (32 0F ~ 113 0F)
Working Humidity 10% ~ 90% relative non-condensing
Switch Mode Space Division Matrix (SDM)
Control Mode 8/16 bits CPU, Registered Program

Aristel Networks Issued March 2001 page 9
AVAV
256256
System Installation Manual
8. FEATURES LIST
System Features List
Alarm
Attendant Console Assignment
Auto-Attendant
Automatic S.O.S Security System
Automatic Line Access
Automatic Number Redial
Background Music
Be Paged
Call Duration Time Restriction
Call Forwarding (Follow Me)
Call Pick Up
Call Forwarding (All / No Answer / Busy)
Calling Proof
Camp On
Date/Time Setting
Day/Night Service
Day Time Schedule
Dialing Signal (Pulse/DTMF)
Direct Transfer
Direct Intercom Calling
Direct Inward Station Access (DISA)
Door Switch (Open/Close)
Door Phone Connection
Dual-Direction Amplifier
Easy Installation And Operation
Exclusive Hold Recall
Fax Monitor
Flash Time Setting
Flexible Ringing
Flexible Expansion
Flexible Function Key Setting
Forced Account Code
Help List

Aristel Networks Issued March 2001 page 10
AVAV
256256
System Installation Manual
Hold Recall
Host PABX Access
Hot Line
I/O Terminal
Illegal Dialing Prevention
Incoming Paging
Message Waiting
Metering Detector
Monitoring Level
Music On Hold
Night Transfer
On Call Programming
One Touch Dialing
Overriding Level
Paging/Meet Me Paging
Password Protection
Pause
Polarity Reverse Detection
Programmable DSS Key
Relay Control
Remote Programming
Remote Maintenance
Reset Security Code
Sensor Detection
SLT Programming Digit
SLT Message Waiting Type
SLT Connection
SLT Hold Operation
SLT Busy Remind Tone Flag
Speed Dial For Both System And Private
Station Message Detail Record (SMDR)
Switching Link Maintenance
System Battery Back Up For Data
System Data Initial
System Data Print Out
Text Message
Time-Reminding Service
Toll Restriction

Aristel Networks Issued March 2001 page 11
AVAV
256256
System Installation Manual
Trunk Administration
Trunk Queuing
Varying Range For Time Setting
Station Features List
8 Segments Volume Control
9 Segments Ringing Frequency
Absent Message
Access To System Programming
Account Code
Answer Call Waiting
Auto-Answer
Automatic Line Access
Automatic Call Back (Camp On)
Back Ground Music
Bottom Back Cabling
Calculator Function At Anytime
Call Pick-Up
Call Forward (Follow Me)
Call Waiting
Call Door Phone
Camp On
Check In
Check Out
Day/Night Service Indication
Direct Call Transfer
Direct Call Attendant
Direct Intercom Calling
Do Not Disturb (DND)
Door Switch Sensor Control
Door Phone Call Signaling
Dual Color LED
Flash (Open Loop Time Flash)
Forced Account Code
Door Phone
External Music Source
External Paging Equipment
Forced Account Code

Aristel Networks Issued March 2001 page 12
AVAV
256256
System Installation Manual
Handsfree
Intercom Calling
Last Number Redial
LED Indication For Door Switch Sensor
Macro Key Assignment
Monitor
Movable LCD Display
Multi-Conference
Music On Hold
One Touch Dialing
Outward Dialing
Override (Barge In)
Paging/Meet Me Paging
Photo Interrupted For Hook Switch
Privacy Release
Pulse/Tone Conversion
Save Number Redial
Speed Dialing
Speed Dial Number Storage
Station Lock/Unlock
Station Morning Call Service
Toll Restriction
Tri-Status LED Indication
Trunk Queuing
Volume Digital Control
Zone Paging

Aristel Networks Issued March 2001 page 13
AVAV
256256
System Installation Manual
9. PCB and CABINET LAYOUT
9.1 System Three-Dimensional Layout (One cabinet)
Figure 1.1 AV-256 System Three-Dimensional Layout
1. System dimension555mm W × 228mm D × 400mm H
2. System AC Power115/230VAC ±10%, 60/50 Hz
Wiring outlet
Screw hole
Screw hole
AC power switch
ACpowerconnector
Radiator hole

Aristel Networks Issued March 2001 page 14
AVAV
256256
System Installation Manual
9.2 AV256 System one cabinet Inter-Circuit Layout
Figure 1.2 AV-256 (one cabinet) Installation Layout
1. AV-256 (one cabinet Max. Capacity): 64 Ports / 8 Slots
2. CO Line (one cabinet Max. Capacity): 20
3. Intercom Line (one cabinet Max. Capacity): 64
AC Power Indication LED
AC Power Switch
A4MBUA
AC Power FUSE
DC Power FUSE
DC Power Switch
DC Connector
A2PSUA
A4MPUA
A4IPUA
8 I/O Interface Slots for
A2TKUA or A4STUA
A4SLUA or A4HYUA
A4VSUA or A2RSCA
A2RPCA or A2MFCA
System Expansion
Connectors

Aristel Networks Issued March 2001 page 15
AVAV
256256
System Installation Manual
9.2.1 AV-256 System two cabinets Inter-Circuit Layout
Figure 1.3 AV256 (two cabinets) Installation Layout
1. AV-256 (two cabinets Max. Capacity): 128 Ports / 16 Slots
2. CO Line (two cabinets Max. Capacity): 40
3. Intercom Line (two cabinet Max. Capacity): 128
Connective Cable
between two Cabinets
Dip Switch for the setting of the
cabinet’s position number. In the
1st cabinet, the 1st mini switch
must be ON and other mini
switches must be OFF. In the 2nd
cabinet, the 2nd mini switch must
be ON and other mini switches
must be OFF.

Aristel Networks Issued March 2001 page 16
AVAV
256256
System Installation Manual

Aristel Networks Issued March 2001 page 17
AVAV
256256
System Installation Manual
9.2.2 AV256 System three cabinets Inter-Circuit Layout
Figure 1.4 AV256 (three cabinets) Installation Layout
1. AV-256 (three cabinets Max. Capacity): 192 Ports / 24 Slots
2. CO Line (three cabinets Max. Capacity): 40
3. Intercom Line (three cabinets Max. Capacity): 192
9.2.3 AV256 System four cabinets Inter-Circuit Layout
Connective Cable
Dip Switch for the setting of the
cabinet’s position number.
In the 1st cabinet, the 1st mini
switch must be ON and other
mini switches must be OFF.
In the 2nd cabinet, the 2nd mini
switch must be ON and other
Dip Switch for the setting of the
cabinet’s position number.
In the 1st cabinet, the 1st mini
switch must be ON and other
mini switches must be OFF.
In the 2nd cabinet, the 2nd mini
switch must be ON and other
Connective Cable
Connective Cable
between the two

Aristel Networks Issued March 2001 page 18
AVAV
256256
System Installation Manual
Figure 1.5 AV-256 (four cabinets) Installation Layout
1. AV-256 (four cabinets Max. Capacity): 256 Ports / 32 Slots
2. CO Line (four cabinets Max. Capacity): 40
3. Intercom Line (four cabinets Max. Capacity): 256
9.3 AV-256 System Wall Mounting Installation
Figure 1.6 AV-256 System Wall Mount Layout
9.4 A4MBUA (Mother Board Unit)
Wall Mounting Position Hole
Front Cover
Wall Mounting Hole
A4MBUA
Mini switches must be OFF.
In the 3rd cabinet, the 3rd
only switch 3 must be on

Aristel Networks Issued March 2001 page 19
AVAV
256256
System Installation Manual
Figure 1.7 A4MBUA
9.5 A2PSUA /A2PWUA (Switching Power Supply)
Power Output Connecter
Power Fuse
AC Power Input
Output Power Trimming

Aristel Networks Issued March 2001 page 20
AVAV
256256
System Installation Manual
Figure 1.8 A2PWUA Module Layout
brown
green
blue
red
white
black
red
white
black
brown
green
blue
Table of contents
Other Aristel Telephone Accessories manuals
Popular Telephone Accessories manuals by other brands

TFA
TFA SMARTHY quick start guide

ATON
ATON CL111 user manual

MOB
MOB MO6595 user manual

Lucent Technologies
Lucent Technologies LULCST Installation and use manual

Avaya
Avaya PARTNER Advanced Communications System Installation and programming instructions

Grandstream Networks
Grandstream Networks HandyTone-496 user manual

Nortel
Nortel Meridian 1 PC Console Interface Unit Quick reference guide

Heyday
Heyday QIC43 user manual

SSS Siedle
SSS Siedle CL A 0 B Series Product information

Panasonic
Panasonic DBS Caller ID Installation and operation guide

Hama
Hama 00201518 operating instructions

AT&T