Aristel DV-96 User manual

System Installation Manual DV-96
INTRODUCTION
This manual provides detailed procedures to install your new ARISTEL DV-96
Digital Key Telephone System. Please read this entire section before
proceeding with the actual installation.
The National Electrical Code (NEC) requires the local telephone company
(Telecom) to provide the primary protection devices for the telephone lines
terminating at the customer’s site. Make sure that a primary protection device
has indeed been installed by the Telecom. If no such device is present, notify
the Telecom before installing your Aristel system.
1
Arista Systems Corporation

System Installation Manual DV-96
GENERAL DESCRIPTION
Aristel DV-96 Fully Digital Key Phone System is an intelligent Telecom device and
based on state of the art advanced technology. This system uses digital circuitry
employing PCM, TDM, 2B+D, etc. The multi-function digital key phone has very
flexible programming functions. The users can simply operate the DSS keys to
activate the applications, as they require. The new built-in Voice Mail not only
provides standard voice mail functions but also has the Intelligent Recording
function – to record message during conversation. The Windows version
Customer Manager System (CMS) is fully integrated into the system to make
customer management easier and more efficient.
Aristel DV-96 Intelligent Digital Key Telephone System, has the listed capacities:-
trunk card (basic 4 lines per card, maximum 4 cards = 16 ports) and 16~64 extension
ports. It can also be equipped with the following system peripherals: SMDR interface,
Door Phone Interface, Multi-Function Sensor Interface, Multi-Function Relay, Remote
Programming Interface, External Music Interface, External paging interface, Voice
Mail andAuto Attendant Interface, DECT Interface, ADSL/ISDN…etc.
Aristel DV-96 Digital Intelligent Key Telephone System uses modular PCB
construction. External-Line, Internal-Line and peripherals of the main system are
completely independent PCBs. All functions can be programmed to Macro keys,
enabling complex functions to covert into single-keypad operation. This is an excellent
option for the new digital age; Aristel DV-38 is the best partner to lead you into the
diverse broadband world of telecommunications
2
Arista Systems Corporation

System Installation Manual DV-96
Aristel DV-96 Digital Intelligent Key Phone System
Multiple Processors.
Time Division Multiplexing.
Unique ARISTELASIC Chip “A-SERIES”
3
Arista Systems Corporation

System Installation Manual DV-96
SYSTEM CONFIGURATION
System Capacity and Specifications
DV-96 Basic Capacity
Expandable
Capacity Max. Capacity
POTS 4 12 16
ISDN (BRI) 0 0 ~ 8 8
CO Line
ISDN (PRI) 0 30 30
Key phone Digital 16/0 48/0 64/0
Single Line Phone 2 64 66
Auto Attendant 0 4/0 4/0
Voice Mail 0 0/4 0/4
Voice
Service
interface Recording
Extension 0 26 26
Door Phone interface 0 2 2
Relay Switches 0 2 2
Sensor 0 2 2
Fax Monitor 1 3 4
RS232 For SMDR 0 1 1
Remote Programming 0 1 1
UPS interface 1 0 1
Speed Dial 1000 sets 0 1000 sets
Caller ID card 0 16 16
Power Failure Transfer Phone 1 3 4
External Music 1 0 1
External Paging 0 1 1
4
Arista Systems Corporation

System Installation Manual DV-96
KEY TELEPHONE SPECIFICATION
DIGITAL KEY TELEPHONE
Key Phone Model DKP30 DKP31 DKP32 DKP33 DKP50 DKP51 DKP52 DKP53
DSS Function Key 12 Keys 12 Keys 12 Keys 12 Keys 25 Keys 25 Keys 25 Keys 25 Keys
2 * 16 digits LCD
Display …………
Back-Light LCD Display ……………Option …Option
Hands-Free Dialing
Direct intercom
Outgoing Call
Hands-Free …………
Internal/External
Direct Dial
Photo Interrupt
Hook Switch
Digital Volume Control 8 Levels 8 Levels 8 Levels 8 Levels 8 Levels 8 Levels 8 Levels 8 Levels
OHCA Function …………
One Touch Paging
Last Number Redial
Name Speed Dial …………
Calculator ………………
Individual Speed Dial
Difference Ringing
Frequencies
Dual Color Tri Status
LED 8 keys 8 keys 8 keys 8 keys 16 keys 16 keys 16 keys 16 keys
One Digit Auto Answer
Incoming LED
Indication
Remarks: Postfix W= White Color, C= Dark Grey Color, B= Back-Light LCD Display
5
Arista Systems Corporation

System Installation Manual DV-96
SYSTEM MODEL DESCRIPTION
Model Description Remark
D2-416DK Main Service Unit - Consisting of Metal Cabinet + D2MBUB +
D2PWUA + D1TKUC + D2DLUA Standard Shipment
D2CBMA Main Service Unit - Consisting of Metal Cabinet + D2MBUB +
D2PWUA) Standard Shipment
D2MBUB Mother Board Unit Spare Part
D2PWUA Power Unit Spare Part
D1TKUC
Trunk Unit - Consisting of 4 PSTN ports with Polarity Reverse, one
Fax port Connector、one PFT port connector and Interface for
D1MDCA and D1CIDA Connections.
Expansion Card
D1DTKC ISDN Trunk Card - Consisting of 2 BRI S/T interface Optional Card
D2DLUA Digital Key Station Unit – Consisting of 16 Digital Key Station ports Expansion Card
D1SLCB Single Line Station Card – Consisting of 2 Single Line Station Ports Expansion Card
D2SLUA Single Line Station Unit – Consisting of 16 single line station ports Expansion Card
D2HYUA Hybrid Station Unit – Consisting of 2 digital key station ports plus 12
single line station ports. Expansion Card
D1RSCC RS232 Card – Providing 1 RS232 port and working for SMDR Optional Card
D1VSCA Voice Service Card – Consisting of 2 Voice Channels (60 sec. per
channel) for Auto Attendant applications Optional Card
D1VSCB Voice Service Expansion Card -
A
dditional 2 Voice Channels (60
sec. per channel) for Auto Attendant applications Optional Card
D1MFCA Multi Function Card –
(2 Doors + 2 Relays + 2 Sensors + 1 External Paging) Optional Card
D1MDCA Meter Pulse Detection Card - 12KHz/16KHz Meter Pulse Detection Optional Card
D1CIDC FSK/DTMF CLI Interface - One Channel of POTS Caller Number Expansion Card
D1RPCA Remote Programming Card - Providing 1 standard modem port 2400 Optional Card
D1VMCA Built-in Voice Mail Card - 2 ports of Voice Mail with 6.5 hours Optional Card
D1VMEA Voice Mail Expansion Card - one port of Voice Mail Optional Card
6
Arista Systems Corporation

System Installation Manual DV-96
D1VMFA Expansion Flash Memory - Software control with 4 hours store Optional Card
WP5007 25-Pair Amphenol Cable – (for Station Wiring Connection) Optional Required
ENVIROMENTAL REQUIREMENT
Only authorized personnel should install the Key System Unit (KSU) at a
clean, dry and secure location accessible. The location must have
adequate ventilation and a temperature range between 0 ~ 45o C with a 10
~ 90% non-condensing relative humidity.
The installation site should have sufficient room to mount the KSU along
with the necessary connecting blocks and ancillary equipment on a wall.
The installation site should not be in areas subject to static electricity (e.g.
Dry copiers), or vibration (e.g. Heavy machinery).
A dedicated earthed power outlet for the KSU (either 240VAC/50Hz or
110VAC/60Hz) and a 10 Amp circuit are required. An integral earth is
required in the AC power cord. If a music source or optional external
paging equipment is installed, it must be connected to an AC circuit
separate from the KSU’s dedicated AC line. ONLY THE KSU’S POWER
SUPPLY SHOULD BE CONNECTED TO THE DEDICATED AC OUTLET
7
Arista Systems Corporation

System Installation Manual DV-96
EQUIPMENT REQUIREMENT
Prior to installation, carefully inspect all packages for evidence of damage.
Compare the equipment received against equipment ordered to ensure that
ALL components have been received.
The following materials are required (not provided) for installation:
Exterior grade plywood backs board for the KSU.
1 Male-Tail per extension board for Station wiring.
Two-pair or Three-pair (for OHCAStation) twisted station cable.
Appropriate mounting hardware.
8
Arista Systems Corporation

System Installation Manual DV-96
POWER SUPPLY AND KSU INSTALLATION
Attach the plywood backboard to the selected location with the
appropriate fasteners.
A surge protector should be installed at the dedicated AC outlet.
Connect Male-Tail, and connect the plug to each station board for station
wiring; also connect the wire to the RJ-11 for connector on each trunk card
for the CO lines wiring.
Plug in the power cord of the power supply to an AC Power Outlet and
then turn on the power of the system.
9
Arista Systems Corporation

System Installation Manual DV-96
PCB AND CABINET LAYOUT
SYSTEM INTER-CIRCUIT LAYOUT
D2PWUA
D2DLUA
D2SLUA
D2HYUA
D1TKUC
D1DTKA
D1DTKB
3
4
2
1
D1SLCB
D2MBUB
D1VSCA
D1VMCA
D1RPCA
D1RSCC D1MFCA
5
1. AC Power Inlet.
2. AC Power Switch.
3. Power Indicator(LED Type).
4. DC Power Switch.
5. RS232 (Female DB9) for the connection to the D1RSCC.
10
Arista Systems Corporation

System Installation Manual DV-96
D2MBUB (Mother Board Unit)
Product: DV-96 Mother Board Unit
Item: D2MBUB
Size: 310 mm x 130 mm
Function:
1. The motherboard control entire system functions and audio switching.
2. Motherboard supports External Music Source Input Terminal.
3. System programming Auto-Protection by Li Battery. 181
10
20
3
19
11
2
4
The Installation Site of D2MBUB
7
14 8 17916
6
12
5
15
11
Arista Systems Corporation

System Installation Manual DV-96
1. POWER: 6 pins Wafer Connector to connect with D2PWUAby 6 wires cable [HD-3903-10,
VH Type]
2. VSC 20P*2 Wafer Connector for D1VMCA or D1VSCAconnections.
3. EPROM: Flash Memory EPROM “ MX29F2000” which stored the system software.
4. CPU: Intel 80188 Processor.
5. RPC: 20P*2 Wafer Connector Either D1RPCA or D1RSCB connections.
6. BAT: “3 VDC, 180mA/H” Li-Battery to back-up system programming data during AC power
failure.
7. RSC: 10P*2 Wafer Connector for D1RSCC connection
8. SVR: Variable Resistor to adjust the volume for either Internal Melody Source or external
Melody Source that use for [BMG] and [MOH] application.
9. MFC: 13P*2 Wafer Connector for D1MFCA connection.
10. SLC: 13P*2 Wafer Connector for D1SLCB connection.
11. DTA1~4: 30P*2 Header Connector for D2SLUA, D2HYUAand D2DLUA connection.
12. ASIC: Aristel proprietary ASIC.
13. LCD: Additional LCD connector for engineering system maintenance.
14. JP1: 3Pins Wafer Jumper to turn ON/OFF Li battery power.
15. TKU1~4 25P*2 Header Connector for both D1TKUC and D1DTKA (ISDN BRI) / D1DTKB
(ISDN PRI) connection.
16. JP2: 3 Pins Wafer Jumper for Internal/External music selection.
17. EX-MUSIC: The input terminal for External Music Source connection.
18. PWR5: 4 Pins Wafer Connector to connect with D2PWUA by 4 wires cable.
19. PWR1~4: 4 Pins Wafer Connector to connect with D2SLUA and D2HYUA by 4 wires
cable.
20. CN1~1: 13P*2 Wafer Connector for EH-64 connection.
12
Arista Systems Corporation

System Installation Manual DV-96
D2PWUA (POWER BOARD UNIT)
Product: DV-96 POWER UNIT
Item: D2PWUA
Size: 270 mm x 95 mm
Function:
1. To supply entire system power.
2. The input AC Voltage ranges are AC110V~240V
3. Support 24V Battery Charger for external
Back-up Battery.
The Installation Site of D2PWUA
7
8
5
1
4
6
2
3
1. LED501: Power Indicator.
2. SW101: AC Power Switch.
3. CN101: AC Power Inlet.
4. CN802: 4 PinsConnector. ( for D2MBUB connection)
5. SW401: External backup battery Power Switch.
6. CN105: Protection Earth Terminal for D1SLCB Grounding.
7. CN402: External Battery Connector; Left Side is (+), Right side is (-).
8. CN301 : 6 Pins Connector for D2MBUB connection.
13
Arista Systems Corporation

System Installation Manual DV-96
D1TKUC (TRUNK UNIT, 4 TRUNK PORTS)
Product: DV-96 TRUNK UNIT
Item: D1TKUC
Size: 162 mm x 122 mm
Function:
1.
2.
3.
Support Polarity Reverse detection for each CO lines.
A maximum of 4 D1TKUC boards can be installed onto the DV-96 main frame.
Support either D1CIDC (FSK/DTMF CLI interface) or D1MDCA (Meter Pulse
Detection Card) connections on each CO line.
1
2
3
4
The Installation Site of D1TKUC
1. CN1: 60-Wires rainbow Cable to connect to TKU1~4 positions where upon the
D2MBUB.
2. CN3: The socket for both Power Failure standard Phone and FAX connections.
3. CN2: The RJ socket for POTS CO lines connections.
14
Arista Systems Corporation
4. CH1A~4A and CH1B~CH4B: Connectors for each CO lines to interface either
D1CIDC or D1MDCA.

System Installation Manual DV-96
D1DTKA (ISDN BRI Trunk Unit)
Product: DV-96 ISDN TRUNK UNIT
Item: D1DTKA (ISDN BRI CARD)
Size: 162 mm x 122 mm
Function
1. Supports 2 lines of 2B+D interface which support 4 voice channels.
2. The system provides 4 slots of ISDN Trunk Unit connector. (Maximum expansion
capability: 8 lines for 2B+D or 16 lines for Voice channel.)
3
1
2
4
7
8
9
5 6
The Installation Site of D1DTKA
1. Test Connector for engineer testing
2. Test Connector for engineer testing
3. Flat cable connect to D1MBUB
4. RJ-45 connector to connect to ISDN BRI Line.
5. JP1 jumper for first line-line termination enable/disable.
6. JP2 jumper for second line-line termination enable/disable.
7. JP3 jumper for DTKA card of TKU slot number.
8. Red LED for Power indication and CPU activity.
15
Arista Systems Corporation

System Installation Manual DV-96
9. Line status indication, red” on” mean line fault.
Green “ on” mean off hook.
JP1: Short: line termination enable (default).
N/C: line termination disable.
JP2: Short: line termination enable (default).
N/C: line termination disable.
JP3: please see below table for reference.
0 1 Slot number of TKU
Short Short 1
N/C Short 2
Short N/C 3
N/C N/C 4
16
Arista Systems Corporation

System Installation Manual DV-96
D1DTKB (ISDN PRI Trunk Unit)
Product: DV-96 ISDN TRUNK UNIT
Item: D1DTKB (ISDN PRI CARD)
Size: 162 mm x 122 mm
Function
1. Supports 1 lines of 30B+D interface, which support 30 voice channels.
2. Maximum one card install per system, when install D1DTKB; system cannot
support D1DTKA as same time.
17
Arista Systems Corporation

System Installation Manual DV-96
D2DLUA (Digital Key Station Unit, 16 Key Station ports)
Product: DV-96 DIGITAL KEY STATION UNIT
Item: D2DLUA
Size: 162 mm x 155 mm
Function:
1. Support 16 ports of digital key phone interface.
2. Totally 4 pieces of D1DLUA could be installed onto the DV-96 main frame (64
Extensions Maximum)
3. D2DLUAis fully compatible with DV-Series Key Telephones. Ex: DKP-30, DKP-31,
DKP-32 DKP-33, DKP-50, DKP-51, DKP-52, DKP-53.
3
4
2
1
The Installation Site of D2DLUA
1. Flat cable connector to D2MBUB STA1~4 slots.
2. Centronic connector for WP5007 cable wiring.
3. Reset Button to Reset the D2DLUA on-board micro-controller.
4. LED (Red) for Power indication and on-board micro-controller activity.
18
Arista Systems Corporation

System Installation Manual DV-96
D2SLUA (Single Line Station Unit, 16 SLT Station Ports)
Product: DV-96 SINGLE LINE STATION CARD
Item: D2SLUA
Size: 195 mm x 69 mm
Function:
1. D2SLUA provides 16 SLT Station Ports.
2. Totally 4 pieces of D2SLUAcould be installed onto the DV-96 main frame. (64 SLT
Maximum).
3
4
2
1
The Installation Site of D2SLUA
1. Flat cable connector to D2MBUB STA1~4 slots.
2. Centronic connector for WP5007 cable wiring.
3. Reset button to reset the D2SLUA on-board micro-controller.
4. LED ( Red) for Power indication and on-board micro-controller.
19
Arista Systems Corporation

System Installation Manual DV-96
D2HYUA (Hybrid Station Unit)
Product: DV-96 HYBRID STATION CARD
Item: D2HYUA
Size: 195 mm x 69 mm
Function:
1. D2HYUA provides 4 Digital Key Station ports plus 12 SLT Stations Ports.
2. Totally 4 pieces of D2HYUA could be installed onto the DV-96 main frame
3. Digital Key Station ports fully compatible with DV-Series Key Telephones. Ex:
DKP-30, DKP-31, DKP-32 DKP-33, DKP-50, DKP-51, DKP-52, DKP-53.
4. Single line station can be connected to SLT ports. EX, SLT, Modem, Wireless
Phone.
3
4
2
1
The Installation Site of D2HYUA
20
Arista Systems Corporation
Table of contents
Other Aristel Telephone Accessories manuals