© 2022 Carrier. All rights reserved. 1 / 2 P/N 00-3280-508-0003-01 • ISS 09DEC22
2X-A Series Quick Operation Guide
Icon
Description
Fire Alarm LED
Fault LED
Sounder Start/Stop button and LED
Panel Silence button and LED
If you hear the buzzer
Determine the cause of the buzzer
WARNING: Depending on your fire alarm system
configuration, the buzzer may be your first indication of a fire
alarm.
If the buzzer is sounding and the LED is flashing or steady,
then it’s a fire alarm.
If the buzzer is sounding and the LED is steady, then it’s a
fault.
For a fire alarm
1. Determine the location of the fire
Check the location of the fire. The LCD message area displays
information from the first and last zones to report an alarm.
Alarm location details are indicated as follows.
LCD
Description Example
d
Number of devices in alarm d:010
P
Control panel ID P01
Z
Zone Z0001
D
Loop and device D3.010
In this example, P01:Z0001:D3.010, an alarm has been
activated by device 10 on loop 3 in zone 1 on control panel 1
(ten devices are in alarm in the corresponding zone).
2. Determine the source of the fire alarm
The following LCD icons indicate the source of the fire alarm.
Detector alarm. If the LED
is flashing and the detector
icon is displayed on the LCD, then the system has
detected a detector alarm.
Manual call point alarm. If the LED is steady, and the
manual call point icon is displayed on the LCD, then the
system has detected a manual call point alarm.
3. Verify the fire alarm
If necessary, investigate the location of the fire alarm to
confirm that the alarm is genuine.
Depending on the configuration of your fire alarm system, you
may have up to ten minutes to investigate the alarm before
sounders and other alarm notification devices are activated.
2 / 2 P/N 00-3280-508-0003-01 • ISS 09DEC22
4. Activate the sounders
If the fire alarm is verified, do either of the following to activate
the sounders and other alarm notification devices immediately:
Break the nearest manual call point.
— or —
Press the button on the control panel.
5. Leave the building
Once the fire alarm has been confirmed and the fire alarm
activated, leave the building and follow your company’s
evacuation drill.
For a fault
1. Silence the buzzer
To silence the buzzer, press the button on the control panel.
The LED turns on and the buzzer stops. New alarm or fault
events will turn the buzzer back on.
Caution: Always confirm the cause of the warning signal
before silencing the buzzer.
Additional information on the fault is available by pressing F1
(Show Events).
2. Contact your maintenance contractor
Contact your maintenance contractor immediately to
investigate and repair the fault.
Other options
Viewing current event information
To view current event information, press F1 (Show events) and
then select the event type to view.
The event types available to this user level are:
• Alarms
• Alerts
• Faults
• Conditions
Conditions include all other system events. Examples: tests
and disablements in the fire system.
Viewing support information
To view support information configured by your installation or
maintenance contractor, press F3 (Support). Your installer or
maintenance contractor may configure different messages to
display in alarm and nonalarm situations.
Note: This information is only available if your installation or
maintenance contractor has added information to the fire
system configuration.
For more information
This document includes basic control panel operation
instructions to be followed in the event of a fire alarm or fault
indication. For detailed operation, refer to the operation
manual.
Maintenance information
Inspect and test the fire alarm system in accordance with all
applicable requirements and regulations.
For service contact:
Name:
Address:
Telephone:
Contact information and product
documentation
For contact information or to download the latest product
documentation, visit firesecurityproducts.com.
Product warnings and disclaimers
THESE PRODUCTS ARE INTENDED FOR SALE TO AND
INSTALLATION BY QUALIFIED PROFESSIONALS.
CARRIER FIRE & SECURITY B.V. CANNOT PROVIDE ANY
ASSURANCE THAT ANY PERSON OR ENTITY BUYING ITS
PRODUCTS, INCLUDING ANY “AUTHORIZED DEALER” OR
“AUTHORIZED RESELLER”, IS PROPERLY TRAINED OR
EXPERIENCED TO CORRECTLY INSTALL FIRE AND
SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers
and product safety information, please check
https://firesecurityproducts.com/policy/product
-
warning/
or scan the QR code:

Other manuals for 2X-A Series

1

Other Aritech Fire Alarm manuals

Aritech 1200C User manual

Aritech

Aritech 1200C User manual

Aritech 1X-F Series User guide

Aritech

Aritech 1X-F Series User guide

Aritech 900 Series User manual

Aritech

Aritech 900 Series User manual

Aritech 2X-F1 User manual

Aritech

Aritech 2X-F1 User manual

Aritech 2X-AF2-FB-PRT-P User manual

Aritech

Aritech 2X-AF2-FB-PRT-P User manual

Aritech 2X Series User manual

Aritech

Aritech 2X Series User manual

Aritech 2X Series User manual

Aritech

Aritech 2X Series User manual

Aritech FP2000 User manual

Aritech

Aritech FP2000 User manual

Aritech 2X-F2-FB2-S-32 User guide

Aritech

Aritech 2X-F2-FB2-S-32 User guide

Aritech 2X Series User manual

Aritech

Aritech 2X Series User manual

Aritech 2X-F1 User guide

Aritech

Aritech 2X-F1 User guide

Aritech DM2010 Assembly instructions

Aritech

Aritech DM2010 Assembly instructions

Popular Fire Alarm manuals by other brands

Ramtech Electronics WES3 troubleshooting guide

Ramtech Electronics

Ramtech Electronics WES3 troubleshooting guide

Teletek electronics SensoIRIS T110 IS Installation instruction

Teletek electronics

Teletek electronics SensoIRIS T110 IS Installation instruction

Harrington Network Plus HS-3030 Programming manual

Harrington

Harrington Network Plus HS-3030 Programming manual

C-TEC FF596 installation instructions

C-TEC

C-TEC FF596 installation instructions

Simplex SafeLINC 4020 troubleshooting guide

Simplex

Simplex SafeLINC 4020 troubleshooting guide

Siemens FDMH294-R Installation

Siemens

Siemens FDMH294-R Installation

usi UNIVERSAL 5304CN instructions

usi

usi UNIVERSAL 5304CN instructions

Sargent 2900 Series FIREGUARD Wiring instructions

Sargent

Sargent 2900 Series FIREGUARD Wiring instructions

Honeywell NFS Supra Installation and operating manual

Honeywell

Honeywell NFS Supra Installation and operating manual

Vigilant FP0539 Operating & installation instructions

Vigilant

Vigilant FP0539 Operating & installation instructions

Aico Residential Fire Detection RFD Product guide

Aico

Aico Residential Fire Detection RFD Product guide

Ramtech WES3 User Guide and Operation Manual

Ramtech

Ramtech WES3 User Guide and Operation Manual

FireAngel W2-CO-10X Installation and user guide

FireAngel

FireAngel W2-CO-10X Installation and user guide

Zeta Alarm Systems 80-210 installation guide

Zeta Alarm Systems

Zeta Alarm Systems 80-210 installation guide

Mircom FA-102T Installation and operation manual

Mircom

Mircom FA-102T Installation and operation manual

Ansul Checkfire MP-N Installation, Recharge, Inspection and Maintenance Manual

Ansul

Ansul Checkfire MP-N Installation, Recharge, Inspection and Maintenance Manual

Cooper Wheelock MTWP-2475W-NW specification

Cooper Wheelock

Cooper Wheelock MTWP-2475W-NW specification

Honeywell Notifier NFS-320SYS manual

Honeywell

Honeywell Notifier NFS-320SYS manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.