Armagard PCB User guide

www.Armagard.com
Page | 1
Toll Free (US): 1-866-434-0807
Call (UK): 0121-608-7210
1. The following manual details the information
and safety precautions needed for the safe
installation of the Armagard deluxe controller
board.
2. All power must be switched off until the
enclosure has been fully assembled and is
ready to use.
3. If your enclosure is for outdoor use, don’t
attempt installation in bad weather; use
correct lighting for optimum viewing
conditions.
4. Armagard recommends that the enclosure
should always be secured to the floor before
adjusting the controller board.
READ THIS MANUAL THROUGH BEFORE INSTALLING YOUR UNITS TO ENSURE CORRECT
INSTALLATION AND THAT YOU’RE COVERED UNDER WARRANTY.
5. Because of its watertight seal, to lock an
enclosure you have to push firmly against
the door and then turn the key.
6. All images used in this manual are for
reference and example purposes only.
7. The final controller board you receive will
differ depending on what has been agreed
on the order with your account manager.
8. Software is compatible with Windows XP
and 7.
Setup Manual
YOUR WARRANTY AGREEMENT IS VOID if you perform any modifications to the
controller board, for example, drilling, penetrating or soldering onto the board.
FOR BEST PRACTICE mount the controller board using the recommended procedure.
Controller Board Setup - Deluxe

www.Armagard.com
Page | 2
Toll Free (US): 1-866-434-0807
Call (UK): 0121-608-7210
The printed circuit board (PCB) automatically manages the ‘deluxe’ features listed below in
addition to the standard on-off commands for an enclosures air curtains, fans, heaters, and
power outlets.
V2 Deluxe Features
1. System LED
a. Blinks constantly to show the system is working.
2. Humidity sensor.
3. Accelerometer.
4. Vehicle detection sensors.
5. Screen detection sensors –using ‘Heartbeat’technology.
6. Radio-frequency identification (RFID) for electronic locks.
7. Door sensor ports (x2) –door open/close sensor ports.
8. Ethernet port
9. Media/TV power outlets (x4) (Pg.6)
Note: Not all of the above features will be available on your board as standard. Some will
only be enabled if they have been agreed with your account manager as part of your order.
Setup Kit
To reconfigure the controller board, you’ll need the setup kit which is provided by Armagard
as an optional extra.
1. USB/IDE setup cable.
2. Software drivers available from Armagard’s support website.
ohttp://support.armagard.com/index.php?/Knowledgebase/Article/View/47/25/a
rmagard-controller-board-setup
oFolder Name: Armagard USB Configurator.zip
Controller Board Setup - Deluxe

www.Armagard.com
Page | 3
Toll Free (US): 1-866-434-0807
Call (UK): 0121-608-7210
1. Screen Detection Sensors –Using ‘Heartbeat’ technology. Optional Feature.
Screen detection involves using a small sensor that is attached to the bottom of the screen
and will identity if the display is operational or not.
This feature runs constantly and will communicate with the controller board, sending out a
‘Heartbeat’ signal over the Ethernet cable via Simple Network Management Protocol
(SNMP). These heartbeats are set to timed intervals (pre-determined) and are viewable
through Armagard’s accompanying interface software.
Step 1: Locate your USB setup cable and download the appropriate drivers from Armagard’s
support website (files needed are detailed on the previous page).
Step 2: To configure the controller board you’ll need a computer (ideally a laptop) close
enough for the USB setup cable to reach the controller board.
Step 3: Unzip the Armagard USB Configurator folder, and copy the ‘ArmagardTerminal’
program and driver information file ‘Armagard USB Configurator.inf’ onto your computers
desktop.
Step 4: Next, locate the controller board within your enclosure. Also take note of the system
LED’s (figure 1).
Warning: Make sure the enclosures power is switched off and unplugged before removing or
attaching the steel lid to avoid the risk of an electric shock.
Figure 1
Step 5: Use a crosshead screwdriver to remove the steel lid that covers the PCB board and
place the removed washers and nylocs to one side.
Step 6: Connect the USB cable into your computer, and then the IDE connector (highlighted
red) onto the controller board (figure 2). Also connect your Ethernet cable if needed.
Automatic Deluxe Features
How to Connect to the Board
LED’s

www.Armagard.com
Page | 4
Toll Free (US): 1-866-434-0807
Call (UK): 0121-608-7210
Figure 2
Warning: Do not touch the controller board if the steel lid has been removed and the power
is turned on.
Step 7: Power the enclosure back on.
Step 8: Once the board is connected to the computer through the setup cable, Windows will
automatically start looking for the drivers. To complete the setup, you’ll need to locate the
driver called ‘Armagard USB Configurator.INF’, which you placed on your computer desktop
earlier. Then simply follow the setup instructions until finished.
Step 9: Once the driver has finished installing, locate the two setup ports which will appear
within Device Manager and take note of which COM numbers that’re displaying. In the
example window below, its showing ports 12 and 13 (figure 3).
Note: Device Manager in Windows 7 can be found in Control Panel > System and Security > System > Device
Manager. For Windows XP, click Start > Control Panel > Performance and Maintenance > System > Hardware
Tab > Device Manager.
Figure 3
Ethernet port
IDE Connector
Media/TV power outlets

www.Armagard.com
Page | 5
Toll Free (US): 1-866-434-0807
Call (UK): 0121-608-7210
Step 10: Open two windows of the terminal program and select each com port from either
window (from step 9), and then press connect on each terminal window (figure 4). Whereby
one window will start to output a stream of information while the other screen will display a
setup menu.
Figure 4
Step 11: On the setup menu, press Enter and the enclosures system will be switched off and
the current settings will be displayed for all the components in the menu shown in figure 5
below.
Figure 5
Step 12: The settings for each component can then be changed by selecting the appropriate
option from the menu in figure 6.

www.Armagard.com
Page | 6
Toll Free (US): 1-866-434-0807
Call (UK): 0121-608-7210
Figure 6
For Example: To change the temperature at which the heater comes on enter ‘4’ followed by
the return key. Then enter the new value followed by the letter ‘C’ (for Centigrade) or ‘F’ (for
(Fahrenheit) followed by the return key, such as 40C.
Note: The menu will time out after 30 seconds if no commands are received and the system
will switch back on.
Step 13: Once your settings have been completed, click disconnect on both the terminal
window and close the terminal program (figure 7). Then turn off the enclosures power and
remove the 3-pin connector. Then secure the steel lid back onto the PCB and turn the power
back on.
Warning: Make sure the enclosures power is switched off and unplugged before removing or
attaching the steel lid to avoid the risk of an electric shock.
Figure 7

www.Armagard.com
Page | 7
Toll Free (US): 1-866-434-0807
Call (UK): 0121-608-7210
For the board to control the media/equipment housed in the enclosure they must be
connected to the controller board. The controller board can supply power by wiring cables
into one of the four power outlets. To do this follow the steps below:
Warning: Make sure the enclosures power is switched off and unplugged before removing
the steel lid to avoid the risk of an electric shock.
Figure 1a
Step 1: Use a crosshead screwdriver to remove the steel lid that covers the PCB board and
place to one side (figure 1a).
Figure 2a
Step 2: Secure the relevant wires specific to your region into the ‘Neutral (N), Live (L) and
Earthed (E)’ outlets (figure 2a).
Step 3: When wiring is complete, secure the steel lid back onto the PCB board and turn the
power back on.
Media/TV Outlets x4

www.Armagard.com
Page | 8
Toll Free (US): 1-866-434-0807
Call (UK): 0121-608-7210
Unresponsiveness
Sometimes a terminal program window can seem unresponsiveness because its other
window is still selected. Make sure to select the window you’re working with properly.
If the terminal program still seems unresponsive, press disconnect at the top of the window
and then press reconnect to establish a new link..
Trouble Shooting
Table of contents
Popular Controllers manuals by other brands

Distech Controls
Distech Controls DA-016N024PX installation instructions

HYDRO-RAIN
HYDRO-RAIN HRM-4 Installation and operation guide

WAREMA
WAREMA 4M230.12 2Down REG manual

Fulham
Fulham Hotspot FHSCP-UNV Series Installation and operation instructions

Robe
Robe ANOLIS Subdrive 4 user manual

Sundrax
Sundrax Splitter PRO user manual

SMC Networks
SMC Networks ITV1000 series manual

KB Electronics
KB Electronics KBDA-24D Installation and operation manual

CD Automation
CD Automation REVO C 3PH 690V user manual

National Instruments
National Instruments NI cRIO-9065 user manual

Mesto
Mesto jamesbury Valv-Powr VPVL Installation maintenance and operating instructions

SKAARHOJ
SKAARHOJ PTZ Pro v2B user guide